BRONCHOSCOPE INSTRUMENTATION

Similar documents
ESOPHAGOSCOPES. Esophagoscope PATIENT SIZE LISTING

BRONCHOPART CLEAR DOUBLE-LUMEN BRONCHIAL TUBE MADE OF PVC BRONCHOPART TUBE SET

PriMed Instruments Inc. ORDER FORM

INSULATED INSTRUMENTS FOR ELECTROSURGICAL PROCEDURES

Maryland dissector, curved jaw, 5mm... Thomas straight handle curved dissector, 5mm... axial handle, insulated (shaft only)

ARTHROSCOPY OUR TECHNOLOGY YOUR SKILL

GYNECOLOGY OUR TECHNOLOGY YOUR SKILL

Bookwalter. Self-Retaining Retractor Catalog. Good exposure is the key to good surgery John Bookwalter, M.D.

Reusable Modular Instruments An AEM Monitor must be used in order to operate AEM monopolar laparoscopic instruments.

PEDIATRIC AND NEONATAL TRACHEOSTOMY CANNULA WITHOUT CUFF

Snowden-Pencer. Single-Piece Laparoscopic Devices

Xenon Fiberoptic Lightsource

GEZE WINDOW TECHNOLOGY, NATURAL VENTILATION AND SHEV GEZE OL LINE MANUAL WINDOW CONTROLS FLEXIBLE MODULAR SYSTEMS BEWEGUNG MIT SYSTEM

BML-3Q-1 BML-4Q-1 USA: CAUTION:

Sontec Instruments. For optimal visibility during surgery, add illumination to your instruments, including: Retractors Elevators Speculums L

Jamshidi bone marrow biopsy needles

PRODUCT CATALOGUE CREATING THE LINKS TO A BETTER WORLD PRODUCTSRODUCTS INTERNATIONAL

AN /2017-E. Cold Light Laryngoscopes with new P-GRIP

OptiCare Scope Cases. Endoscopy Cases

Operation and care of the Visual Optics Fiber Scopes

Preface. Scope of Application. General Requirements for Safety THE SAFETY MARKS USED IN THIS INSTRUMENT

clear vision OptoYag

PLUTO SPOTLIGHT - LED. Features include. Applications. Benefits

SMOKE EVACUATION SYSTEM SAFETY PRECAUTIONS

2014 / Verlichting

P3 Medical. Endotracheal Tubes

Stearns Super-Mod Totally-Enclosed Non-Ventilated (TENV) Modules Featuring

Accessories RiEye Mk2. Accessories OPERATING TABLE RiEye Mk2 MICRO SURGERY

Intelli-Park Series Barrier Arms. Intelli-Park 9. Intelli-Park 14. Intelli-Park 18. Intelli-Park 32

GSW-V. Application example. Special Gripper Vacuum Gripper. Weight 0.12 kg 0.39 kg. Clamping diameter 20 mm 32 mm

United States Patent (19) Koeda et al.

Certificate of Conformity ENT Instruments and accessories (replaces issue of )

OLYMPUS STONE MANAGEMENT. Premium Devices for Efficient and Convenient Stone Treatment

STERILE PROCESSING CONTAINERS AND BRUSHES

ASTRO FF-14NW & FF-14NEW Friction Feeder

sunnex DISTRIBUTOR TASK OFFERING CATALOG

Unmatched versatility. Exceptional quality. Remarkable value.

XPERT SL 45 Slit Lamp. Instruction Manual

MK Series - High Performance Butterfly Valves Operation and Maintenance Instructions

Aer Defense Smoke Evacuator

ATD MM TOUCH UP GUN W/CUP INSTRUCTION MANUAL

ATD PIECE HVLP SPRAY GUN SET INSTRUCTION MANUAL

USER MANUAL LUX-LD30W LED MOVING HEAD

Light Sources Optimal Lighting for Industrial Endoscopy

ECHELON CIRCULAR Powered Stapler

SURGICAL GOWNS & DRAPES

ATD MM PRIMER GUN W/CUP INSTRUCTION MANUAL

USER MANUAL 6 Position Front Connect Rack for TD Series Modules with 16 Channel Modular Front Panel TDP

The KARL STORZ E-Series:

Weck Horizon Ligation System The Name You Know the Product You Trust

Power System STERNAL SAW 3B

ECO Spot 2500 User Manual

LED Golight Stryker - Remote Controlled Spotlight w/ Wired Dash Mount Controller - White

ECO Spot 2500 User Manual

OPERATION MANUAL MODEL MODEL MODEL MODEL MODEL NON-CONDUCTIVE ARTICULATING FIBERSCOPE INSTRUMENT TECHNOLOGY, INC.

Hydraulic PTO Flow Device

6 Million Candlepower Spotlight with Handle - 800' Long x 65' Wide Spot Beam - 12 / 24 Volts DC


OFK-300A OPTIMAX Multi-Lite

HAND CENTRIFUGES. All Syringe caps are autoclavable reusable 60CC LUER LOCK SYRINGE B. Jac-cell

Resection Devices. Retrieval Devices. Retrieval Device. EMR for Upper GI. Stiff Snares. Retrieval Grasping Forceps. Specialty Snares.

Laparoscopy CE / ISO 9001

Unmatched versatility. Exceptional quality. Remarkable value.

LED-HL2-CMP LED Headlight System Operation Manual

Operating Procedures for GripTight High Pressure Test Plug

BD20 Brake Attachment for Hydraulic Wheel Dolly Owner's Manual Contents Introduction Safety Precautions Operating Instructions Specifications

96W Colored LED Light Bar - Completely Submersible 'L X 200'W Spot VDC Lumens

OFK-8000A OPTIMAX Multi-Lite

Hydraulic Light Tower with Diesel Engine Generator - 4X1250 Watt Metal Halide Lamps

Scope. Applicability. Caution. I & M CV3000 Series. Storage. Installation & Maintenance Instructions for Marwin CV3000 Series Three Piece Ball Valves

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

Instructions for Use Reprocessed HARMONIC ACE Shears without Adaptive Tissue Technology. Reprocessed Device for Single Use.

PRIMA DNT User Manual

MINIshock. U.S. Patents 6,468,315 & 6,682,569

Aesculap Service Systems

PRECISION MICROSCOPES

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

UltraSlide The Most Powerful & Versatile Top Slide Surgical Table in the Industry

For orders and enquiries call: TB Davies

Experience the Brilliance of the Vantage Plus Dental System DELMARVA Catalog

Fuel Pro Series Filter/Separator/Warmer Installation Instructions

Fuel Pro FH230 Series Filter/Separator/Warmer Installation Instructions

Capsa healthcare. Avalo Series Medical Carts I-Series Medical Carts

INSTALLATION INSTRUCTIONS South Highway 11 Westminster, SC Toll Free (888) (864) FAX (864)

Weld Heads Low Inertia Parallel and Opposed Gap Weld Heads Instruction Pamphlet

OP2 CosmoPolis Series

Headlights. CUDA Surgical "RCS" Headlight. CUDA Surgical Deluxe Headlight. CUDA Surgical Sport Headlight. CUDA Surgical Video Camera

Selecting Weights and Certificates

Horizon Patient Bed Light LED and Fluorescent Solutions

THE WORLD S FASTEST DUCTING

Low Profile, High Intensity LED Light Bars - 27, 3-Watt LEDs VDC Lumen

GLASS TRANSITION TEMPERATURE (Tg) 65 C >2, , C >2, , C >2, , C 1, ,918 1.

PRODUCT CATALOG PLUG-IT PRODUCTS. - A Different Kind of Plug Company -

FL15 FL50 FL100 USER MANUAL USER MANUAL FL15 PRODUCT OVERVIEW HARDWARE AND SET-UP. page 1

Hydraulic Immediate Need Power Pack

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

INSTRUCTIONS EVIS EXERA XENON LIGHT SOURCE OLYMPUS CLV-160

Cut Away Tire Bead Breaker Model 10101

THE ESSENCE OF POWER AND VERSATILITY IN A UNIVERSAL SURGICAL SYSTEM. Advantages. -No tools or lubrication. -Complete O.R standardization capability

Evolution 3E INSTRUCTION MANUAL. Part 1/2 Ref.: 65051/US. MORIA S.A. 15, rue Georges Besse - F Antony France #65051/US-C-02.

Transcription:

BRONCHOSCOPE INSTRUMENTATION 86 505674 502540 505670 505682 505686 505684 505688 Bronchoscope Side Channel Instruments PILLING FLEXIBLE ENDOSCOPIC FORCEPS The Pilling Flexible Forceps were designed for use with Pilling Laser and Standard Bronchoscopes. They easily pass through the instrument/fiber channel for the purpose of biopsy, foreign body retrieval, and removal of char from laser ablation. These forceps are available in 1 and 2 sizes. CATALOG FOR USE NUMBER DESCRIPTION LENGTH THRU SCOPES 505670 1 Alligator Grasping Fcps. 35 cm 3.5 x 20, 4.0 x 25 505674 1 Oval Cup Biopsy Fcps. 35 cm 3.5 x 20, 4.0 x 25 505680 2 Alligator Grasping Fcps., flexible 40 cm 5.0 x 30, 6.0 x 35 505682 2 Fenestrated Grasping Fcps., flexible 40 cm 5.0 x 30, 6.0 x 35 505684 2 Circular Cup Biopsy Fcps., flexible 40 cm 5.0 x 30, 6.0 x 35 505686 2 Alligator Grasping Fcps., flexible 50 cm 7.0 x 40, 8.0 x 40, 9.0 x 40 505688 2 Fenestrated Grasping Fcps. 50 cm 7.0 x 40, 8.0 x 40, 9.0 x 40 505690 2 Circular Cup Biopsy Fcps. 50 cm 7.0 x 40, 8.0 x 40, 9.0 x 40 Bronchial Instrument Accessories FLUVOG VENTILATION ATTACHMENT For use on bronchoscopes with the 15 proximal extension. Provides closed system bronchoscopy with the use of instrumentation. Tapered fit for easy attachment or removal. 502540 FLUVOG TRANSPARENT SLIDES 502541 For 502540

Bronchoscope and Laser Bronchoscope PATIENT SIZE LISTING NEONATE/INFANT 522575 Holinger................................ 79 522576 Holinger................................ 79 522550 Pilling Improved Holinger................. 80 522552 Pilling Improved Holinger................. 80 LASER 523100P Pilling CO 2.............................. 82 CHILD/PEDIATRIC 522554 Pilling Improved Holinger................. 80 522556 Pilling Improved Holinger................. 80 522576 Holinger................................ 79 522577 Holinger................................ 79 522578 Holinger................................ 79 LASER 523110P Pilling CO 2.............................. 82 78 Pilling Bronchoscopes have been designed in conjunction with Dr. Paul Holinger and Dr. C.L. Jackson for ease in examination and performance of surgical procedures in the lung and bronchi. These instruments utilize fiberoptics to give cool, constant illumination and nearly full lumen view. Each type of scope has channels for ventilation of the patient during the procedure. Refer to Scope Measurement Chart for definition of provided Scope Dimensions on pages 416, 417 and 418. ADOLESCENT 522558 Pilling Improved Holinger................. 80 522579 Holinger................................ 79 522580 Holinger................................ 79 522581 Holinger................................ 79 522582 Holinger................................ 79 522583 Holinger................................ 79 LASER 523120P Pilling CO 2.............................. 82 523130P Pilling CO 2.............................. 82 523176 Pilling YAG.............................. 84 ADULT 522584 Holinger................................ 79 522585 Holinger................................ 79 522586 Holinger................................ 79 522587 Holinger................................ 79 LASER 523140P Pilling CO 2.............................. 82 523150P Pilling CO 2.............................. 82 523160P Pilling CO 2.............................. 82 523178P Pilling YAG.............................. 84 523180P Pilling YAG.............................. 84 523182 Pilling YAG.............................. 84

522578 522580 INCREASED LUMEN 2.5 522575 4.9 522582 12 12 Oval Light Carrier 3.4 522576 5.6 522583 12 12 3.4 522577 5.6 522584 12 12 Bronchoscopes 3.7 522578 6.8 522585 12 12 4.9 522579 HOLINGER VENTILATING FIBEROPTIC BRONCHOSCOPE Designed by Dr. Paul Holinger, these fiberoptic bronchoscopes provide a nearly full view of the lumen with constant, cool illumination. Special features include: 15 sidearm for direct attachment of ventilation and anesthesia apparatus Large fiber bundle for increased distal illumination Oval fiberoptic light carrier, which allows more viewing and instrumentation room in main tube 15 diameter proximal end for attachment of accessories (window plug, Sanders Venturi, etc ) Smooth distal tip Shortened proximal flare Each Holinger Bronchoscope is supplied with one light carrier and one window plug (522595). NOMINAL CATALOG APPROX. OVERALL MIN. PROXIMAL MAX. REPLACE. NUMBER SIZE LENGTH I.D. I.D. O.D. CARRIER 522575 3 x 20 203 2.5 12.0 9.4 527500 522576 3.5 x 25 254 3.4 12.0 12.0 527505 522577 3.5 x 30 305 3.4 12.0 12.0 527510 522578 4 x 30 305 3.7 12.0 12.0 527510 522579 5 x 30 305 4.9 12.0 12.5 527510 522580 5 x 35 364 4.8 12.0 12.5 527515 522581 5 x 40 400 4.8 12.0 12.5 527520 522582 5 x 45 451 4.9 12.0 12.0 527525 522583 6 x 35 369 5.6 12.0 12.0 527555 522584 6 x 40 400 5.6 12.0 13.0 527560 522585 7 x 40 400 6.8 12.0 15.3 527560 522586 8 x 40 400 7.6 13.0 15.4 527580 522587 9 x 40 400 8.5 12.0 16.4 527580 Dimensions without window plug. 7.6 522586 12 13 4.8 522580 8.5 522587 12 12 4.8 522581 12 Drawings illustrate Nominal Proximal Internal Dimensions and Minimum Internal Diameter (I.D.), NOT TO SCALE. 1 2 3 4 5 6 7 8 9 10 79 INCHES

The photo below shows a working combination of the following instruments: 524018 Telescope 2.7, 0 524036 Telescope Guide 2.7 522552 Improved Holinger Bronchoscope 3.5 x 20 505670 Flexible 1 Alligator Forceps 80 522554 INCREASED LUMEN 524042 Oval Light Carrier 2.9 522550 12 Pediatric Bronchoscopes PILLING IMPROVED HOLINGER VENTILATING FIBEROPTIC Our most popular bronchoscope, the Holinger, has been modified for pediatric foreign body removal and features the following: Small distal tip. The original Holinger tip has been cut down to correspond with tube size, while still retaining smoothness Built-in instrument channel for introduction of flexible forceps or disposable suction Full lumen view. The oval fiberoptic light carrier has been raised slightly to provide a full lumen and give more room for instrumentation and a larger viewing area 15 sidearm attachment allows direct attachment of ventilation and anesthesia apparatus Each Pilling Improved Holinger Bronchoscope is supplied with one light carrier, one window plug (522595) and instrument guide rubber cap. NOMINAL CATALOG APPROX. OVERALL MIN. PROXIMAL MAX. REPLACE. NUMBER SIZE LENGTH I.D. I.D. O.D. CARRIER 522550 3 x 20 203 2.9 12.0 9.0 527500 522552 3.5 x 20 203 3.5 12.0 12.0 527500 522554 4 x 20 203 3.9 12.0 12.0 527500 522556 4 x 25 254 3.9 12.0 11.0 527505 522558 5 x 30 305 4.9 12.0 13.0 527510 Dimensions without window plug. NOTE: The light carrier can be removed from the Improved Holinger Bronchoscope and forceps introduced through the light carrier channel with the 2.7 telescope in place (telescope may have to be partially withdrawn in 522550 and 522552 scopes). 3.5 522552 12 3.9 522554 12 3.9 522556 INSTRUMENT GUIDE RUBBER CAPS For Improved Holinger bronchoscopes. 524042 5 per pack 12 4.9 522558 12 Drawings illustrate Nominal Proximal Internal Dimensions and Minimum Internal Diameter (I.D.), NOT TO SCALE.

522595 522596 522590 Bronchoscope and Esophagoscope Accessories and Adapters WINDOW PLUG Fits 15 proximal extension of Holinger and Jackson Bronchoscopes and Esophagoscopes. Provides a closed system for anesthesia in bronchoscopy or inflation during esophagoscopy. 522595 REPLACEMENT LENS 522596 For 522595 window plug ADAPTER Converts Jackson Bronchoscope 11 oxygen connector to standard 15 anesthesia and positive pressure connector. 522590 1 2 3 4 5 6 7 8 9 10 81 INCHES

The photo below shows a working combination of a Laser Bronchoscope mounted on the CO 2 Coupler-Manipulator. 82 523100P 523210P Laser Bronchoscopes PILLING CO 2 BRONCHOSCOPE SYSTEM Pilling, Holinger-type bronchoscope, with window plug Standard 15 anesthesia ventilating arm Dedicated, distally-delivered YAG or suction channel Dedicated, distally-opened smoke evacuation channel Enlarged, oval fiberoptic, distal light carrier One supplied with each scope Seven sizes of CO 2 bronchoscopes available 3.5 523100P 7 523140P 11.3 13.3 4 523110P 8 523150P 11.9 15.3 INCREASED LUMEN NOMINAL CATALOG APPROX. OVERALL MIN. PROXIMAL MAX. REPLACE. NUMBER SIZE LENGTH I.D. I.D. O.D. CARRIER 523100P 3.5 x 20 220 3.5 11.3 11.3 523101 523110P 4.0 x 25 265 4.0 11.9 11.9 523111 523120P 5.0 x 30 315 5.1 13.0 13.0 527550 523130P 6.0 x 35 365 6.0 13.3 13.3 523131 523140P 7.0 x 40 420 7.0 13.3 13.3 527580 523150P 8.0 x 40 415 8.0 15.3 15.3 527580 523160P 9.0 x 40 415 9.0 16.2 16.2 527580 524042 Replaceable rubber cap for Forceps/Suction Channel 523210P Moisture Barrier 5.1 523120P 9 523160P 13 16.2 Oval Light Carrier 6 523130P 13.3 Drawings illustrate Nominal Proximal Internal Dimensions and Minimum Internal Diameter (I.D.), NOT TO SCALE.

523200P 523242P 523244 523246 523248 523250 523252 523254 523256 Laser Bronchoscopes (continued) CO 2 COUPLER-MANIPULATOR Light weight Easy-off disconnect from the Pilling laser bronchoscope Non-explosive, reusable Mucous Barrier Windows 523210P, one supplied Operator s lens, offers 4 times power Joystick has tighten down collar for beam placement and control Galilean focusing lens permits adjustment of beam spot size Standard articulating arm connection fits: Sharplan, Weck, Endolase, Surgilase, and American Surgical Laser CO 2 machines Other articulating arm adapters available 523200P Adapter Ordering Information 523242P Merrimac CO 2 Adapter 523244 Xanar CO 2 Adapter 523246 Coherent CO 2 Adapter* 523248 Inframed TF25 CO 2 Adapter 523250 Inframed 80 CO 2 Adapter 523252 Cooper 250Z and 500Z CO 2 Adapter 523254 Sharplan Quick Disconnect CO 2 Adapter 523256 Sharplan Model 1040 Adapter *May also use 523244 or 523242P Care and Cleaning of CO 2 Coupler Wipe outside surfaces with a germicidal solution DO NOT allow moisture to enter the inside of the coupler DO NOT soal, gas or steam sterilize Store in a clean, dry, dust-free environment Suggested Pilling CO 2 Laser Bronchoscope Package One CO 2 Coupler Manipulator 523200P with Mucous Barrier Window 523210P Articulating Arm Adapter 523230P (if needed) Four Laser Bronchoscopes (choice of seven sizes) One Fiberoptic Light Cable 521160 1 2 3 4 5 6 7 8 9 10 83 INCHES

84 523178P INCREASED LUMEN 524044 Oval Light Carrier Laser Bronchoscopes (continued) PILLING ND: YAG LASER BRONCHOSCOPE SYSTEM Pilling, Holinger-Type Bronchoscope with window plug Standard 15 anesthesia ventilating arm Distal ventilating ports, for upper lobe ventilation Dedicated, distally-delivered YAG or suction channel Dedicated, distally-opened smoke evacuation channel Enlarged, oval fiberoptic, distal light carrier, one supplied with each scope Four sizes of YAG Bronchoscopes available NOMINAL CATALOG APPROX. OVERALL MIN. PROXIMAL MAX. REPLACE. NUMBER SIZE LENGTH I.D. I.D. O.D. CARRIER 523176 6.0 x 35 365 6.0 12.0 16.0 523131 523178P 7.0 x 40 415 6.7 12.0 16.3 527580 523180P 8.0 x 40 415 7.0 12.0 16.0 527580 523182 9.0 x 40 420 9.0 12.0 17.0 527580 524042 Replacement rubber cap for YAG Fiber Channel 6.0 523176 12 6.7 523178P 12 TELESCOPES Required for visualization of placement of YAG fibers and probes Pilling Rod Lens Telescopes give superior optics, distal lighting, variety of lengths, sizes and degrees Telescopes guides for telescope placement Telescopes to use with YAG Bronchoscopes YAG TELESCOPES TELESCOPE SIZE 523176 6.0 x 35 524014 4.0, 60, 39 cm 524037 4.0, Telescope Guide 523178P 7.0 x 40 524030 5.5, 60, 49 cm 523180P 8.0 x 40 524000 5.5, 60, 49 cm 523182 9.0 x 40 524010 5.5, 90, 49 cm 524038 5.5, Telescope Guide 524050 4.0, 0, 45 cm TELESCOPE LOCKING DEVICES Designed to hold telescopes at a maximum desired depth against our telescope guide, or to lock telescope into a competitive telescope bridge ystem. The serrated knob is tightened to hold the telescope. 524043 2.7 524044 4.0 524045 5.5 7.0 523180P 12 9.0 523182 12 Drawings illustrate Nominal Proximal Internal Dimensions and Minimum Internal Diameter (I.D.), NOT TO SCALE.

523230P 523232P 523234P 524037 524040 502540 524042 Laser Bronchoscopes (continued) Safety Precautions During Laser Bronchoscopy: 1. As with all laser surgical procedures, protective eyewear must be worn during Laser Bronchoscopy. 2. The CO 2 Coupler-Manipulator should be connected to the articulating arm of the CO 2 machine prior to the onset of the procedure. 3. The alignment arm of the CO 2 machine should be checked prior to the procedure. 4. When attaching the CO 2 Coupler-Manipulator to the bronchoscope, check for a snug fitting of the coupler and the bronchoscope. 5. Do not turn on the CO 2 machine until the surgeon is ready and directs it to be turned on. OTHER LASER PRODUCTS AVAILABLE FROM PILLING 523230P Articulating Arm Alignment Device 523232P Laser Centering Device 523234P Far Field Alignment Indicator TELESCOPE GUIDES Fits the proximal end of bronchoscopes and esophagoscopes to hold telescope in place. Not supplied with bronchoscope or esophagoscope. 524036 For 2.7 telescopes, fits 15 proximal end of bronchoscopes or esophagoscopes 524037 For 4.0 telescopes, fits 15 proximal end of bronchoscopes or Jackson Esophagoscope 524038 For 5.5 telescopes, fits 15 proximal end of bronchoscopes or esophagoscopes REPLACEMENT TELESCOPE GUIDE RUBBER CAPS 524039 For 2.7 telescope, 524036, 5 per pack 524040 For 4.0 telescope, 524037, 5 per pack 524041 For 5.5 telescope, 524038, 5 per pack FLUVOG VENTILATION ATTACHMENT For use on bronchoscopes with the 15 proximal extension. Provides closed system bronchoscopes with the use of instrumentation. Tapered fit for easy attachment or removal. 502540 FLUVOG TRANSPARENT SLIDES 502541 For 502540 INSTRUMENT GUIDE RUBBER CAPS For Improved Holinger Bronchoscopes or Laser Bronchoscopes Instrument Channel. 524042 5 per pack 1 2 3 4 5 6 7 8 9 10 85 INCHES