DIESEL GENERATOR SET MTU 16V4000 DS2250

Similar documents
DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 12V4000 DS2000

DIESEL GENERATOR SET DP01800D5S

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET DS01650D5S

DIESEL GENERATOR SET MTU 20V4000 DS3100

DIESEL GENERATOR SET MTU 20V4000 DS2650

DIESEL GENERATOR SET DS03200D5S

DIESEL GENERATOR SET DP03000D5S

DIESEL GENERATOR SET MTU 20V4000 DS3250

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 18V2000 DS1400

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 16V2000 DS KVA

DIESEL GENERATOR SET MTU 12V4000 DS1750

DIESEL GENERATOR SET MTU 16V2000 DS1000

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 16V2000 DS1100

DIESEL GENERATOR SET MTU 20V4000 DS3300

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 12V4000 DS2250

DIESEL GENERATOR SET MTU 20V4000 DS4000

DIESEL GENERATOR SET MTU 20V4000 DS3600

KVA KW KVA KW

DIESEL GENERATOR SET MTU 10V1600 DS500

DIESEL GENERATOR SET MTU 4R0113 DS80

DIESEL GENERATOR SET DG00660D5

DIESEL GENERATOR SET MTU 12V1600 DS660

POWER MODULE MTU 16V4000 DS2560

KVA KW KVA KW

KVA KW KVA KW

20' STANDARD CONTAINER MTU 16V2000 DS: kva MTU 18V2000 DS: kva

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

PRODUCT PRESENTATION SERIES kva. MTU Onsite Energy Systems GmbH All rights reserved

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

Standby Rating 220/ / / / / /

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

STANDBY 200 ekw 250 kva

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

PRIME 225 ekw 281 kva

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

Diesel generator set QSK23 series engine

Model NA 2 L

3412C Generator Set Electric Power. Specifications. Benefits and Features

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

Voltage 220 to or 1800 RPM

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Part III : Technical Specification POS C)

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

Diesel generator set QSK23 series engine

Diesel generator set QSX15 series engine

Cat 3412 Diesel Generator Sets

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

Generator Set Specifications 60 ekw (75 kva)

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

Cat C32 Diesel Generator Sets

Cat C32 Diesel Generator Sets

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

Cat C Diesel Generator Sets

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

130 KW / 165 KVA POWERED by

DIESEL GENERATOR DATA SHEET

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Cat 3516B Diesel Generator Sets

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

Specifications. 3406C Generator Set Electric Power

Transcription:

DIESEL GENERATOR SET MTU 16V4000 DS2250 380V 11 kv/50 Hz/Data Center Continuous Power/Fuel Consumption Optimized MTU 16V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits - Low fuel consumtion - Optimized system integration ability - High reliability - High availability of power - Long maintenance intervals // MTU Onsite Energy is a single-source supplier // Support - Global product support offered // Standards - Engine-generator set is designed and manufactured in facilities certifi ed to standards ISO 2008:9001 and ISO 2004:14001 - Generator set complies to ISO 8528 - Generator meets NEMA MG1, BS5000, ISO, DIN EN and IEC standards - NFPA 110 // Power Rating - System ratings: 2050 kva - 2150 kva - Accepts rated load in one step per NFPA 110 - Generator set complies to G3 according to ISO 8528-5 - Generator set exceeds load steps according to ISO 8528-5 // Performance Assurance Certification (PAC) - Engine-generator set tested to ISO 8528-5 for transient response - 100% load factor - Verifi ed product design, quality and performance integrity - All engine systems are prototype and factory tested // Complete range of accessories available - Control panel - Circuit breaker/power distribution - Fuel system - Fuel connections with shut-off valve mounted to base frame - Starting/charging system - Exhaust system - Mechanical and electrical driven radiators - Medium voltage alternators // Emissions - Fuel consumption optimized // Certifications - CE certifi cation option

2 / / / MTU 16V4000 DS2250 / 50 Hz / 380V - 11kV APPLICATION DATA ➀ // Engine Manufacturer MTU Model 16V4000G23 Type 4-cycle Arrangement 16V Displacement: l 76.3 Bore: mm 170 Stroke: mm 210 Compression ratio 16.4 Rated speed: rpm 1500 Engine governor ADEC (ECU 7) Max power: kwm 1798 Air cleaner Dry // Fuel System Maximum fuel lift: m 5 Total fuel flow: l/min 20 l/hr g/kwh At 100% of power rating: 407.3 188 At 75% of power rating: 310.3 191 At 50% of power rating: 217.7 201 // Liquid Capacity (Lubrication) Total oil system capacity: l 300 Engine jacket water capacity: l 175 Intercooler coolant capacity: l 50 // Combustion Air Requirements Combustion air volume: m 3 /s 2.1 Max. air intake restriction: mbar 50 // Cooling/Radiator System Coolant flow rate (HT circuit): m 3 /h 68.5 Coolant flow rate (LT circuit): m 3 /h 30 Heat rejection to coolant: kw 710 Heat radiated to charge air cooling: kw 260 Heat radiated to ambient: kw 90 Fan power for mech. radiator (40 C): kwm 38 // Exhaust System Exhaust gas temp. (after turbocharger): C 480 Exhaust gas volume: m 3 /s 5.4 Maximum allowable back pressure: mbar 85 Minimum allowable back pressure: mbar 30 ➀ All data refers only to the engine and is based on ISO standard conditions (25 C and 100m above sea level). ➁ Values referenced are in accordance with ISO 3046-1. Conversion calculated with fuel density of 0.83 g/ml. All fuel consumption values refer to rated engine power.

3 / / / MTU 16V4000 DS2250 / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES // System Ratings (kw/kva) Generator model Voltage Fuel consumption optimized 40 C/400m without radiator with mechanical radiator with electr. driven radiator kwel kva* AMPS kwel kva* AMPS kwel kva* AMPS Marathon 744RSL7092 380 V 1680 2100 3191 1640 2050 3115 1640 2050 3115 (Low voltage 400 V 1680 2100 3031 1640 2050 2959 1640 2050 2959 marathon standard) 415 V 1680 2100 2922 1640 2050 2852 1640 2050 2852 Marathon 1020FDL7093 380 V 1680 2100 3191 1640 2050 3115 1640 2050 3115 (Low voltage 400 V 1680 2100 3031 1640 2050 2959 1640 2050 2959 marathon oversized) 415 V 1680 2100 2922 1640 2050 2852 1640 2050 2852 Leroy Somer LSA 51.2 VL90 380 V 1720 2150 3267 1680 2100 3191 1680 2100 3191 (Low voltage 400 V 1720 2150 3103 1680 2100 3031 1680 2100 3031 Leroy Somer) 415 V 1720 2150 2991 1680 2100 2922 1680 2100 2922 Marathon 1020FDH7097 11 kv 1680 2100 110 1640 2050 108 1640 2050 108 (Medium volt. marathon) Leroy Somer LSA 53.1 UL85 11 kv 1720 2150 113 1680 2100 110 1680 2100 110 (Medium volt. Leroy Somer) * cos phi = 0,8 // Engine 4-Cycle Standard single stage air filter Oil drain extension & shut-off valve Closed crankcase ventilation with improved oil seperator Governor-electronic isochronous Common rail fuel injection Fuel consumption optimized engine Centrifugal oil filter // Generator NEMA MG1, BS5000, ISO, DIN EN and IEC standards Self-ventilated Superior voltage waveform Solid state, volts-per-hertz regulator No load to full load regulation ±0,25% voltage regulation no load to full load Brushless alternator with brushless pilot exciter 4 pole, rotating fi eld Sustained short circuit current of up to 250% of the rated current for up to 10 seconds (marathon generator) Sustained short circuit current of up to 300% of the rated current for up to 10 seconds (Leroy Somer generator) Marathon low voltage generator Leroy Somer generator Oversized generator Medium voltage generator Represents standard features Represents optional features

4 / / / MTU 16V4000 DS2250 / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES, CONTINUATION // Cooling System Jacket water pump Thermostat(s) Water charge air cooling Mechanical radiator Electrical driven front-end cooler Jacket water heater // Control Panel Pre-wired control cabinet for easy application of customized controller (V1+) Island operation (V2) Automatic mains failure operation with ATS (V3a) Automatic mains failure operation incl. control of generator and mains breaker (V3b) Island parallel operation of multiple gensets (V4) Automatic mains failure operation with short (< 10s) mains parallel overlap synchronization (V5) Mains parallel operation of a single genset (V6) Mains parallel operation of multiple gensets (V7) Basler controller Deif controller Complete system metering Digital metering Engine parameters Generator Protection Functions Engine protection SAE J1939 engine ECU communications Parametrization software Multilingual capability Multiple programmable contact inputs Multiple contact outputs Event recording IP 54 front panel rating with integrated gasket Different expansion modules Remote annunciator Daytank control Generator winding temperature monitoring Generator bearing temperature monitoring Differential protection with multi-finction protection relay Modbus RTU-TCP gateway // Circuit Breaker/Power Distribution 3-pole circuit breaker 4-pole circuit breaker Manual-actuated circuit breaker Electrical-actuated circuit breaker Stand-alone solution in seperate switch box // Fuel System Flexible fuel connectors mounted to base frame Fuel filter with water separator Switchable fuel filter with water separator Seperate fuel cooler Fuel cooler integrated into cooling equipment Represents standard features Represents optional features

5 / / / MTU 16V4000 DS2250 / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES, CONTINUATION // Starting/Charging System 24V starter Starter batteries Battery rack & cables Battery charger // Mounting System Welded base frame Resilient engine and generator mounting Modular base frame design // Exhaust System Exhaust bellows with connection flange Exhaust silencer with 10 db(a) sound attenuation Exhaust silencer with 30 db(a) sound attenuation Exhaust silencer with 40 db(a) sound attenuation Y-connection-pipe Represents standard features Represents optional features

6 / / / MTU 16V4000 DS2250 / 50 Hz / 380V - 11kV WEIGHTS AND DIMENSIONS Drawing above for illustration purposes only, based an standard open power 400 Volt engine-generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unit specific template drawings. System Dimensions (L x W x H) Weight (dry/less tank) Open Power Unit (OPU) 5090 x 1836 x 2330 mm 12893 kg Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific engine-generator set. SOUND DATA // Consult your local MTU Onsite Energy distributor for sound data. EMISSIONS DATA // Consult your local MTU Onsite Energy distributor for emissions data. RATING DEFINITIONS AND CONDITIONS // Data Center Continuous Power ratings apply to Data Center installations where a reliable utility power is available and comply with Uptime Institute Tier III and IV requirements. At constant or varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO 8528-1, ISO 3046-1, BS 5514 and AS 2789. Average load factor: 100%. // Deration factor: Altitude: Consult your local MTU Onsite Energy Power Generation distributor for altitude derations. Temperature: Consult your local MTU Onsite Energy Power Generation distributor for temperature derations. Rated power is available up to 40 C and 400m above sea level. Subject to change. 3238411 Edition 01/14 ENC 2014-07. Materials and specifications subject to change without notice. MTU Onsite Energy A Rolls-Royce Power Systems Brand www.mtuonsiteenergy.com