Model WEP Electro-pneumatic positioner. WEP positioner A valve control without compromise

Similar documents
ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

RSD100 (Contrac) Electrical Linear Actuator

EAS822 (Contrac) Power Electronic Unit

RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator

Moving Coil Indicators with direct temperature sensor input

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

FICHA TÉCNICA DE PRODUTO

Shut-off valves and accessories for pressure measuring instruments

Control Valve 23 / 24 Single-seat straight-way valve with exchangeable seat ring

Model 266HSH Gauge pressure transmitter low power consumption (1 to 5 V DC and HART)

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. Electronic unit and accessories Retrofitting on Contrac

ABB measurement & analytics data sheet. Model M26 Manifold line for 266 pressure transmitters

Valve Blocks. For direct flanging to pressure and differential pressure transmitters. Drop-forging housing. Replaceable valve seat

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

TZIM. Electropneumatic Analog Positioner 10/ EN

ABB MEASUREMENT & ANALYTICS DATA SHEET. AV1 and AV2 Characterizable pneumatic and electro-pneumatic positioners

Field IT Actuators & Positioners. Intelligent Electric Modulating Actuator. Contrac RHD Intelligent Electric Modulating Actuator

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

SPANS AND RANGES. Lower Range Limits 150 in. H 2 O ( 38 kpa) 800 in. H 2 O ( 200 kpa)

Series AV1 / 2 / 3 / 4 Characterizable pneumatic positioners

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Series AV1 / 2 / 4 Characterizable pneumatic positioners

Electrical Linear Actuator RSD10 / RSD20 (Contrac)

POSITIONERS and Controls for Complete Valve Automation

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

2600T Series Pressure Transmitter

ABB i-bus KNX DG/S x DALI-Gateway Basic

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

Control Valves Positioner

Control Valves Positioner

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar

The perfect solution for wellhead flow measurement with CoriolisMaster, ProcessMaster and VortexMaster

Field instrumentation. Electropneumatic units. as I/P converters and positioners

Contrac RSD 200. Electrical Linear Actuator for Continuous Control Rated Force 200 kn 10/ EN. Application. Positioning:

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS

HART NEW. Digital Positioner PFLEX - Hart Protocol. Characteristics

Fig Single-Acting Rotary Smart Positioner

ABB Automation. Characterizable Pneumatic Positioners Series AV1/2/3/4. Series AV1/2/3/4 Pneumatic Positioners

Endura AZ10 Oxygen probe Sensor sub-assembly tested spares kit

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5500 Wire rope load cell

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

Surge arrester POLIM-H..SD

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5190 Trough hole (annular) heavy capacity load cell

Type 3660 and 3661 Positioners

Series 3730 Electropneumatic Positioner Type

ABB Automation. Variable Area Dial Flow Indicator Series 10A2227. Series 10A2227 Variable Area Dial Flow Indicator

Surge arrester POLIM-H.. ND

Surge arrester POLIM-C.. HD

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Electro-Pneumatic Positioner YT-1000 / 1050 SERIES

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

ZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement

Service Fieldbus Engineering and Consulting

Field IT Actuators & Positioners Rotary Actuators - Rated Torque 100 Nm (80 ft-lbs) PME 120-AI/AN. Rotary Actuators Rated Torque 100 NM (80 ft-lbs)

ABB Instrumentation. Noflote designed for control of conductive liquids. Reliable on/off liquid level control for alarms or pump control

ABB cable glands SCG series Stainless Steel 316L, general purpose cable glands

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

OM Field-Type I/P Converter Model : KUX113 User's Manual

RSD10, RSD20 (Contrac) Electric Linear Actuators. For continuous positioning, rated force 10 / 20 kn (2250 / 4500 lbf)

Valve Positioners Series 760P/E Valve Positioners

Safety interlock switch MKey

Corrosion Resistant Pneumatic Positioners Model 4700P and 4700E

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Electro-Pneumatic Linear Positioner Installation and Operation Instructions B GB

Series 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability

fact sheet Masoneilan * 8012/8013 Series Electro-pneumatic Valve Positioners GE Oil & Gas Excellent Dynamic Response and Positioning Accuracy

3582 Series Pneumatic and Type 3582i Electro-Pneumatic Valve Positioners

Differential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT and DPGT43.160

Angle Seat Control Valve 7020

SS3 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

MEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter

Direct Coupled Damper Actuator Model MY9050A1001

ABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Compact differential pressure switch Models DC, DCC

MEDIUM VOLTAGE PRODUCT. KECA 80 D85 Current Sensor Instructions for installation, use and maintenance

FasTrak High Capacity Smart Positioner

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications

Electronic Limit Switch Type

Type Type 1001 Transducers. I/P & E/P Transducers

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

EMPAC Metal enclosed capacitor bank for wind applications

Mini contactors B6, BC6 with 3 pole

Product information. ECOSS Electronic compact starter for wound rotor drives

Actuators & Positioners Characterizable Pneumatic Positioners Series AV1/2/3

System 6000 Electropneumatic Converters for DC ranges I/P Converter Type 6102 Type 5288

Transcription:

Data Sheet DS/WEP-EN Rev. C Model WEP Electro-pneumatic positioner WEP positioner A valve control without compromise Standard - ma input Single acting, force-balance operating principle Excellent dynamic response short positioning time and negligible positioning error Field adjustable for valve strokes between mm and mm (/ in and in) Accurate means of split-ranging the signal and/or selecting the valve action Set and forget reliability Complies with relevant international standards for test procedures, environmental protectionagainst harsh plant conditions Single feedback cam with three standardcharacteristics

Model WEP, identifies the valve positioner of the P Series of field mounting instruments; it consists of two functional parts: the input stage accepts a - ma signal and produces a corresponding -5 pneumatic signal used by the positioning section. WEP positioner ensures that the control valve plug position is always directly proportional to the input signal, regardless of diaphragm actuator hysteresis, packing-box friction or offbalance force on the valve plug. The valve responds to infinitely small changes in the controller output signal when process lags require the use of wide proportional band. Problems usually associated with plant instability due either to oversized valves or non-linear trim characteristics are minimized by selecting one of the three feedback cam alternative positions. Turn-down ratio to by a single controller output signal split ranging for sequential operation of two or more control valves is standard. FUNCTIONAL SPECIFICATIONS Input signal to ma dc Split-range Any value up to 5% of specified input range Output to actuator Up to 95% of auxiliary supply pressure; direct or reverse acting selectable on the positioning section Cam characteristics See figure. Linear, quadratic or square root pattern. Special characterization is available on request. PERCENT INSTRUMENT PRESSURE SPAN 8 6 Direct acting positioner 6 8 PERCENT VALVE STEM TRAVEL 6 8 Reverse acting positioner Linear cam Square root cam Quadratic cam Input resistance < 7 Ω Auxiliary air supply pressure (instrument air). to, to, to 6 Auxiliary supply static consumption @,., supply : 5 Nl/h (. scfm) @ 75,.75, supply : 6 Nl/h (.8 scfm) @,, 6 supply : 56 Nl/h (. scfm) Flow capacity (dynamic) @,., supply: - input increasing: up to 9 Nl/h - input decreasing: up to 9 Nl/h @ 75,.75, supply: - input increasing: up to 6 Nl/h - input decreasing: up to 9 Nl/h @,, 6 supply: - input increasing: up to 8 Nl/h - input decreasing: up to 9 Nl/h Ambient temperature: Reference : +5 to +5 C ± C (+59 to +77 F ± F) Operative limits : - and +85 C (- and +85 F) Relative humidity : Reference : 5% to 65% RH rmal, operative, transport/storage limits : to % RH condensing permissible Barometric pressure : Reference : 96, 96 m, 7 mmhg ±% rmal, operative, transport/storage limits : atmospheric pressure Vibration (IEC 65-) : Reference : none rmal, operative limits : severity class steady state - f = to Hz; displ..5 mm - acc..5 g - f = to 6 Hz; displ..5 mm - f = 6 to 5 Hz - acc. g Start point and span adjustments Separate, continuous, internal on the positioning section Stroke length Any value between mm and mm (/ in and in) providing feedback lever rotation is 5

6 6 PERFORMANCE SPECIFICATIONS (Reference conditions, - ma standard input range, standard linear cam and direct acting positioner. Unless otherwise specified errors, are quoted as % of span) Accuracy ± % (includes combined effects of non-linearity, hysteresis and repeatability). Indication accuracy: ± % f.s.d. Operating influences Ambient temperature per K (8 F) change between the limits of - and +6 C (- and + F) Zero error: ±.% of span Span error: ± % of reading Double the effect between the limits of - and - C (- and - F) or +6 and +85 C (+ and +85 F) Auxiliary supply per 5, 5 m, 5 change Total effect (zero and span) : ± % Humidity and ometric pressure : no effect EMI/RFI Comply with EN 58-/EN 58- requirements and tests; CE marking. Mounting position Total effect with reference to figures below: ±% for a tilt of ±9 from α axis +7% for a tilt of -9 from ß axis -% for a tilt of +9 from ß axis FRONT VIEW α PHYSICAL SPECIFICATIONS Materials Manifold, I/P converter housing and cover, positioner section case Low-copper content aluminium alloy with baked epoxy finish; AISI 6 ss. Positioner section cover P.T.B. - glass fibre reinforced polibutilentereftalathe, impact - resistant self-extinguishing polyester. Colour: red RAL Input bellows: Brass; AISI 6 ss. Other internal parts: AISI series ss Identification tag AISI 6 ss permanently mounted - characters max (legend to be specified) Gauges Brass with stainless steel case or AISI 6 ss, as specified Optional extras Supply and output Gauges Ext. dia mm indication on 6 (66 mm long) scale. - / - / -6 Airset with/without gauge Environmental protection Wet and dust-laden atmospheres The instrument is weatherproof and completely enclosed to IP 55 according to IEC59 (IP 65 for I/P converter). Pneumatic connections Supply and output / in NPT female -9 +9 Electrical connections One / NPT or Mx.5 or PG.5 or / GK threaded conduit entry, direct on converter housing SIDE VIEW (ß) Terminal block Two terminals for signal wiring up to.5 mm on converter unit. Net weight.5 kg approx. (5.5 lb) aluminium case version without optional extras Packing: Cardboard box -9 +9

ORDERING INFORMATION Select one character or set of characters from each category and specify complete catalog number. PRODUCT CODE abc d e f g h i j k lm BASE MODEL ELECTRICAL CERTIFICATION MATERIALS OF CONSTRUCTION INPUT SIGNAL RANGE ELECTRICAL CONNECTION SPRING PRESSURE RANGE OF THE ACTUATOR PRESSURE GAUGES CAM CHARACTERISTIC ACTION PRESETTING abc BASE MODEL - st to rd characters Electro-pneumatic positioner Code WEP d ELECTRICAL CERTIFICATION - th character t certified e MATERIALS OF CONSTRUCTION - 5th character Input bellows and relevant parts Brass AISI 6 ss Case Aluminium Aluminium Positioner case cover Polyester Polyester f INPUT SIGNAL RANGE - 6th character to ma dc to ma dc, Split range to ma dc, Split range 6 g ELECTRICAL CONNECTION - 7th character /" NPT - f /" GK - f M x.5 - f Pg.5 - f 5 h SPRING PRESSURE RANGE OF THE ACTUATOR - 8th character to 5 to. to i PRESSURE GAUGES - 9th character Output Supply te : The material of the case is Stainless Steel Materials (te) - - Brass Brass AISI 6 ss AISI 6 ss 5 j CAM CHARACTERISTIC - th character Standard k ACTION PRESETTING - th character Direct action Reverse action 5 lm th to th characters Use code

"Ex" Safety marking label DIMENSIONS (not for construction unless certified) Supply gauge I/P converter unit Output gauge Electrical connection 5 Min. clearance to remove the cover 9 6 7 Exhaust 6 6 7 7 5 8 - + Serial number tag 5 5 7 6 Pneumatic positioner section Identification tag Exhaust External earth connection PNEUMATIC AND ELECTRIC CONNECTIONS Internal earth connection I/P module Electrical cable entry Input current signal Terminal block 5 Supply pressure 6 6 Output pressure I/P converter section

Contact us ABB Ltd. Howard Road St. Neots Cambridgeshire PE9 8EU UK Tel: + ()8 75 Fax: + ()8 798 ABB Inc. 5 E. County Line Road Warminster PA 897 USA Tel: + 5 67 6 Fax: + 5 67 78 te We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts is forbidden without prior written consent of ABB. Copyright ABB All rights reserved DS/WEP-EN Rev. C. ABB Automation Products GmbH Schillerstr. 7 5 Minden Germany Tel: +9 55 95 5 Fax: +9 55 95 555 ABB S.p.A. Via Statale 6 Lenno (CO) Italy Tel: +9 58 Fax: +9 5678 www.abb.com