Mooney* Type 24/24S Restrictor

Similar documents
Mooney* Series 20/20S/20H/20HS Pilots

Masoneilan* 7700P/7700E Series Pneumatic & Electro-Pneumatic Positioner for Masoneilan* VariPak* Control Valve

Masoneilan* Model 37/38 Spring-Diaphragm Actuators

Masoneilan* Varilog* MS Control Valve

73000 Series Masoneilan* Sweep Angle Control Valves Models XX-73471

Masoneilan* 87/88 Series

Masoneilan* Series Eccentric Rotary Control Valve with PFA Liner Instruction Manual

Masoneilan* Series Actuators Spring Diaphragm and Differential Pressure for use with 525, 526, 535H and 536H Regulators

Consolidated* Valves 1511 Series Safety Valve

Masoneilan* Series Eccentric Rotary Control Valve with PFA Liner

Masoneilan* Series Double Ported Globe Valve

Masoneilan* Series Eccentric Rotary Control Valve with PFA Liner

GE Oil & Gas. 525 & 526 Models. Masoneilan* Reducing and Back Pressure Regulators. Instruction Manual. GE Data Classification: Public

SERIES 20/20S/20H/ 20HS PILOT

Masoneilan* 51/52/53 Series

Masoneilan* Series Direct-Operated, Pressure Reducing Regulator

87/88 Pneumatic Multi-Spring Diaphragm Actuators

Masoneilan * Series Three-Way Control Valves Combining and Diverting Service

Masoneilan* Series

Technical Specifications 11/2014. GE Oil & Gas. Series Texsteam* Electric Driven Injection Pump. GE Data Classification : Public

Masoneilan* 525 & 526 Models Reducing and Back Pressure Regulators

31/32 Spring Diaphragm Rotary Actuators

Masoneilan * Lo-dB Cartridges and Expansion Plates

Masoneilan * Series

48000 Series Masoneilan* High Temperature High Pressure Globe Cage Valves

Masoneilan* Series SteamForm*

Masoneilan* Series Camflex* II

GE Oil & Gas. Masoneilan * Engineered Products. Valve Solutions and Services for the World s Toughest Applications. Experience Knowledge Technology

Masoneilan* 215X1 Series Control Valve

fact sheet Masoneilan * 8007/8008 Series Electro-pneumatic Transducers GE Energy Nozzle Design Reducing Effects of Vibration Overview

SERIES 20L FLOWGRID TM PILOTS INSTALLATION / OPERATION / MAINTENANCE MANUAL

Models 4700P/4700E & 4800P/4800E

Becker* FEP-1000/1500-CH Series Flexible Element Pilot

Masoneilan* Series Varipak

fact sheet Masoneilan * 8012/8013 Series Electro-pneumatic Valve Positioners GE Oil & Gas Excellent Dynamic Response and Positioning Accuracy

21000 Series. Masoneilan * Valves. High-Performance Control Valves

PVI 60KW, PVI 82KW, PVI 95KW

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

Masoneilan * Series

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

INSTALLATION/OPERATION/MAINTENANCE MANUAL for the FlowMax REGULATOR

41005 Series. Masoneilan * Valves. Heavy Duty, Globe-Style Control Valves

35002 Series Camflex * II Rotary Control Valves

Specification Data CY /10. Putting You In Control Series Actuators. for use with 525, 526, 535H and 536H Regulators

TMCo,, Inc. The Measurement Company

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

BIN & SEN Annular Pitot Tube Flow Meter. Form: 10-PTT-UM (December 2012) Installation & Operation Manual

Submersible Waterfall Pump 1200 Gallons Per Hour

OPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

OPERATING INSTRUCTIONS AND PARTS LIST

type 122a three-way Switching Valve

Pressurized Pond Filter Up to 850 gallons

10000 Series Control Valves

Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual -

21000 Series Control Valves. Putting You In Control Series. High Performance Globe Style Control Valves

HR-20P Pneumatically Controlled Pressure Regulator

CLIF MOCK TM. Model 5030 Orifice Fitting. User Manual. Manual No , Rev. B

Y690A Series Pressure Reducing Regulators

289 Series Relief Valves

12 Meter Add-On Kit for the Hustler 4/5/6-BTV Vertical Antennas

Becker* FEP-175/600-CH Series Flexible Element Pilot

WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

41005 Series Heavy Duty - Severe Service. Putting You In Control Series. Maximum Performance Globe Style Control Valves

GE Oil & Gas Series. Masoneilan* Energy Management Control Valve. Instruction Manual. GE Data Classification: Public

Model 200 Multi-Jet Flow Meter. 02-PDM-UM (July 2012) Installation & Operation Manual

Type 289P Pilot-Operated Relief Valve

Masoneilan* Series Energy Management Control Valve Instruction Manual (Rev.C)

Type 289P Pilot-Operated Relief Valve

Model Series 66 Amplifying and Reducing Relays

INSTALL GUIDE Dodge/RAM 5.7L HEMI

Container Fountain Kit with LED Light

Submersible Pond Pump with UV 800 Gallons Per Hour

S8JX-N/S8JX-G Series Replacement Brackets

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

Illumifalls Patio Pond

Premium Pond Pump 330 Gallons Per Hour

Low-Water Auto Shutoff Pump 420 Gallons Per Hour

Operating and Installation Instructions

Natural Fiber Planter Fountain

30 Meter Add-On Kit for the DXE-8040VA-1 Vertical Antenna

UXC.COM A PUBLICATION OF. NPO Overview 1501 MACY DRIVE ROSWELL, GA PH FX

DODGE CUMMINS 24V ISB OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

Model 12BL Filter Press, Multi Unit. # Unit # Unit. Instruction Manual. Updated 08/25/2015 Ver. 2.0

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

PCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems

Premium Waterfall Pump 1200 Gallons Per Hour

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

MODEL 73N BUILT-IN VALVE POSITIONER

GE Oil & Gas. Technical Specifications 07/ Series. Masoneilan * High Performance Butterfly Valves (HPBV)

Submersible Waterfall Pump 1250 Gallons Per Hour

Fisher CVX Hydro Plug Fixture

Y690A Series Pressure Reducing Regulators

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

"Buyer" or "you" means the person, firm or corporation to whom the order is addressed.

430B SERIES HORIZONTAL SPLIT CASE PUMP

Transcription:

GE Oil & Gas Mooney* Type 24/24S Restrictor Installation, Operation and Maintenance Manual (Rev. C) GE Data Classification : Public

THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC REFERENCE INFORMATION IN ADDITION TO THE CUSTOMER/OPERATOR S NORMAL OPERATION AND MAINTENANCE PROCEDURES. SINCE OPERATION AND MAINTENANCE PHILOSOPHIES VARY, GE (GENERAL ELECTRIC COMPANY AND ITS SUBSIDIARIES AND AFFILIATES) DOES NOT ATTEMPT TO DICTATE SPECIFIC PROCEDURES, BUT TO PROVIDE BASIC LIMITATIONS AND REQUIREMENTS CREATED BY THE TYPE OF EQUIPMENT PROVIDED. THESE INSTRUCTIONS ASSUME THAT OPERATORS ALREADY HAVE A GENERAL UNDERSTANDING OF THE REQUIREMENTS FOR SAFE OPERATION OF MECHANICAL AND ELECTRICAL EQUIPMENT IN POTENTIALLY HAZARDOUS ENVIRONMENTS. THEREFORE, THESE INSTRUCTIONS SHOULD BE INTERPRETED AND APPLIED IN CONJUNCTION WITH THE SAFETY RULES AND REGULATIONS APPLICABLE AT THE SITE AND THE PARTICULAR REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE. THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE CUSTOMER/OPERATOR S PURPOSES THE MATTER SHOULD BE REFERRED TO GE. THE RIGHTS, OBLIGATIONS AND LIABILITIES OF GE AND THE CUSTOMER/OPERATOR ARE STRICTLY LIMITED TO THOSE EXPRESSLY PROVIDED IN THE CONTRACT RELATING TO THE SUPPLY OF THE EQUIPMENT. NO ADDITIONAL REPRESENTATIONS OR WARRANTIES BY GE REGARDING THE EQUIPMENT OR ITS USE ARE GIVEN OR IMPLIED BY THE ISSUE OF THESE INSTRUCTIONS. THESE INSTRUCTIONS ARE FURNISHED TO THE CUSTOMER/OPERATOR SOLELY TO ASSIST IN THE INSTALLATION, TESTING, OPERATION, AND/OR MAINTENANCE OF THE EQUIPMENT DESCRIBED. THIS DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN APPROVAL OF GE. 2 GE Oil & Gas 2017 General Electric Company. All rights reserved.

Scope This manual provides installation, operation and maintenance instructions for the Type 24/24S Mooney Restrictor. Instructions for the Flowgrid* Pilot and Valve will be found in separate manuals. Product Description The Type 24/24S Mooney Restrictor is an integral part of a pilot system for the Flowgrid Regulator. It is usually located in the pilot supply and affects the response rate, stability, and sensitivity of the regulator. The restrictor is available in both steel and stainless steel constructions with a stainless steel rotor. The Type 24/24S Restrictor can be used in many other liquid and gas applications. Installation The following instructions apply to mounting the Type 24/24S Mooney Restrictor on the Flowgrid Pilot and connecting to the pilot system. Refer to the Flowgrid Valve and Pilot I/O/M manuals for start up procedures. WARNING Personal injury, equipment damage, or leakage due to explosion of accumulated gas or bursting of pressure containing parts may result if this RESTRICTOR is overpressured or is installed where service conditions could exceed the limits given in the specification of the nameplate, or where conditions exceed any ratings of the adjacent piping or piping connections. Verify the limitations of valve, pilot, and restrictor to ensure these devices are not overpressured. To avoid such injury or damage, provide pressure relieving or pressure limiting devices (as required by Title 49, Part 192, of the U.S. code of Federal Regulations, by the National Fire Codes of the National Fire Protection Association, or by other applicable codes) to prevent service conditions from exceeding those limits. Additionally, physical damage to the valve/regulator could break the pilot or restrictor off the main valve, causing personal injury and/ or property damage due to explosion of accumulated gas. To avoid such injury and damage, install the regulator in a safe location. Figure 1. Type 24 Mooney Restrictor 1. PERSONNEL: Installation of the Restrictor should be made by qualified personnel familiar with high pressure piping and pilot operated regulators. 2. PRIOR INSPECTION: Inspect the Restrictor for any damage that might have occurred in shipping. If already mounted on a regulator make sure the regulator body, pilot lines, and inlet piping are clear and free of foreign material. 3. ORIENTATION: The Type 24/24S Mooney Restrictor should be installed so that the adjustment indicator markings face the side of the regulator that provides easiest access for pilot adjustment and valve maintenance. 4. RESTRICTOR MOUNTING: Apply pipe dope to the 1/4 NPT threads on the male end of the restrictor and screw directly into the INLET port of the PILOT. NOTE: To avoid galling when stainless steel to stainless steel connections are made use a lubricant (such as NEVER SEEZ by Bostik1). For best results lightly lubricate the female threads. Mixing the lubricant with pipe dope is also acceptable. When tightening do not exceed more than 1/4 turn past the point the threads start to bind. 5. RESTRICTOR INLET: A Filter (such as the Type 30 Mooney filter) upstream of the restrictor is recommended. Run 3/8 inch tubing from the supply tap to the inlet of the restrictor. 2017 General Electric Company. All rights reserved. Mooney Type 24/24S Restrictor Instruction Manual 3

Start-up and Operation 1. Adjustment of the restrictor affects the response rate, stability, and sensitivity of the regulator. CLOSING the pilot restrictor (moving adjustment towards MIN setting) will result in higher gain (narrower proportional band), more sensitivity, and slower closing speeds. OPENING the pilot restrictor (moving the adjustment towards MAX setting) will result in less gain (increased proportional band), less sensitivity, and faster closing speeds. WARNING The Rotor Core and Rotor Retainer are designed to move together during adjustment. If debris, rust, ice or other elements are preventing the Rotor Retainer from moving during adjustment, the unit may come unscrewed after multiple adjustments. Care should be taken to ensure tightness of components and proper movement during adjustment. NOTE: The Type 24/24S Mooney Restrictor itself does not require any special start-up procedures. 2. START-UP - ALL REGULATORS: Generally widening the proportional band when initially starting up a regulator (restrictor setting of 4 or higher) is recommended. This will insure maximum stability when starting the regulator. Consult the instruction manual for the valve and pilot being used. Maintenance Restrictor parts are subject to normal wear and must be inspected and replaced as necessary. The frequency of inspection and replacement of parts depends on severity of service conditions or the requirements of local, state, and federal regulations. WARNING Before disassembly, make sure the regulator and restrictor have been isolated from the process by closing block valves on the inlet and outlet sides of the regulator. Safely release pressure and process fluid from body and pilot system. Failure to properly complete these steps may result in personal injury and property damage. Disassembly 1. After depressurizing main valve, pilot system and restrictor remove Rotor assembly by loosening Rotor Retainer. 2. Inspect Rotor and O-Rings for defects and replace if necessary. Assembly 1. Lubricate O-Rings with Parker O-Lube1 (or equivalent petroleum based lubricant) and place one on the Rotor Core and one on the Rotor Retainer. 2. Install Rotor Core back into the Restrictor Body and screw Rotor Retainer with O-Ring into place snugly. NOTE: Overtightening an O-Ring Joint will not improve the seal. Screw in until metal parts make contact and snug slightly. Figure 2 Type 24, 24S Mooney Restrictor Parts Item Description Material Part Number Quantity 1 Body Steel (Zinc Plated) Stainless Steel 240-002-01 240-002-02 2 Rotor Core Stainless Steel 240-007-01 1 3 Rotor Retainer 4 O-Ring Nitrile Viton Table 1 Rotor Core Body O-Ring O-Ring Rotor Retainer Stainless Steel 240-006-01 1 021-001-01 021-011-02 1 1 2 2 4 GE Oil & Gas 2017 General Electric Company. All rights reserved.

Limited Warranty Seller warrants that Products shall be delivered free from defects in material, workmanship and title and that Services shall be performed in a competent, diligent manner in accordance with any mutually agreed specifications. The warranty for Products shall expire one (1) year from first use or eighteen (18) months from delivery, whichever occurs first, except that software is warranted for ninety (90) days from delivery. The warranty for Services shall expire one (1) year after performance of the Service, except that software-related Services are warranted for ninety (90) days. If Products or Services do not meet the above warranties, Buyer shall promptly notify Seller in writing prior to expiration of the warranty period. Seller shall (i) at its option, repair or replace defective Products and (ii) re-perform defective Services. If despite Seller s reasonable efforts, a non-conforming Product cannot be repaired or replaced, or non-conforming Services cannot be re-performed, Seller shall refund or credit monies paid by Buyer for such non-conforming Products and Services. Warranty repair, replacement or re-performance by Seller shall not extend or renew the applicable warranty period. Buyer shall obtain Seller s agreement on the specifications of any tests it plans to conduct to determine whether a non-conformance exists. Buyer shall bear the costs of access for Seller s remedial warranty efforts (including removal and replacement of systems, structures or other parts of Buyer s facility), de-installation, decontamination, re-installation and transportation of defective Products to Seller and back to Buyer. The warranties and remedies are conditioned upon (a) proper storage, installation, use, operation, and maintenance of Products, (b) Buyer keeping accurate and complete records of operation and maintenance during the warranty period and providing Seller access to those records, and (c) modification or repair of Products or Services only as authorized by Seller in writing. Failure to meet any such conditions renders the warranty null and void. Seller is not responsible for normal wear and tear. This Article 5 provides the exclusive remedies for all claims based on failure of or defect in Products or Services, regardless of when the failure or defect arises, and whether a claim, however described, is based on contract, warranty, indemnity, tort/extra-contractual liability (including negligence), strict liability or otherwise. The warranties provided in this Article 5 are exclusive and are in lieu of all other warranties, conditions and guarantees whether written, oral, implied or statutory. NO IMPLIED OR STATUTORY WARRANTY, OR WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE APPLIES. Product Support Local support is available through our manufactures representative and distributor network. Contact the factory: GE Oil & Gas 12970 Normandy Drive Jacksonville, FL 32221 Tel. +1-844-VALVE-GE or refer to our website for your support representative contact information. Factory support is available from 8:00 AM to 4:30 PM MST Monday through Friday. Limited after hours support is also available. Complete product specifications, parts lists, and flow calculation software is available on our website www.geoilandgas.com/valves 2017 General Electric Company. All rights reserved. Mooney Type 24/24S Restrictor Instruction Manual 5

Notes 6 GE Oil & Gas 2017 General Electric Company. All rights reserved.

Notes 2017 General Electric Company. All rights reserved. Mooney Type 24/24S Restrictor Instruction Manual 7

DIRECT SALES OFFICE LOCATIONS AUSTRALIA Brisbane: Phone: +61-7-3001-4319 Fax: +61-7-3001-4399 Perth: Phone: +61-8-6595-7018 Fax: +61 8 6595-7299 Melbourne: Phone: +61-3-8807-6002 Fax : +61-3-8807-6577 BELGIUM Phone: +32-2-344-0970 Fax: +32-2-344-1123 BRAZIL Phone: +55-19-2104-6900 CHINA Phone: +86-10-5689-3600 Fax: +86-10-5689-3800 FRANCE Courbevoie Phone: +33-1-4904-9000 Fax: +33-1-4904-9010 GERMANY Ratingen Phone: +49-2102-108-0 Fax: +49-2102-108-111 INDIA Mumbai Phone: +91-22-8354790 Fax: +91-22-8354791 New Delhi Phone: +91-11-2-6164175 Fax: +91-11-5-1659635 ITALY Phone: +39-081-7892-111 Fax: +39-081-7892-208 JAPAN Tokyo Phone: +81-03-6871-9008 Fax: +81-03-6890-4620 KOREA Phone: +82-2-2274-0748 Fax: +82-2-2274-0794 MALAYSIA Phone: +60-3-2161-0322 Fax: +60-3-2163-6312 MEXICO Phone: +52-55-3640-5060 THE NETHERLANDS Phone: +31-15-3808666 Fax: +31-18-1641438 RUSSIA Veliky Novgorod Phone: +7-8162-55-7898 Fax: +7-8162-55-7921 Moscow Phone: +7 495-585-1276 Fax: +7 495-585-1279 SAUDI ARABIA Phone: +966-3-341-0278 Fax: +966-3-341-7624 SINGAPORE Phone: +65-6861-6100 Fax: +65-6861-7172 SOUTH AFRICA Phone: +27-11-452-1550 Fax: +27-11-452-6542 SOUTH & CENTRAL AMERICA AND THE CARIBBEAN Phone: +55-12-2134-1201 Fax: +55-12-2134-1238 SPAIN Phone: +34-93-652-6430 Fax: +34-93-652-6444 UNITED ARAB EMIRATES Phone: +971-4-8991-777 Fax: +971-4-8991-778 UNITED KINGDOM Bracknell Phone: +44-1344-460-500 Fax: +44-1344-460-537 Skelmersdale Phone: +44-1695-526-00 Fax: +44-1695-526-01 UNITED STATES Jacksonville, Florida Phone: +1-904-570-3409 Corpus Christi, Texas Phone: +1-361-881-8182 Fax: +1-361-881-8246 Deer Park, Texas Phone: +1-281-884-1000 Fax: +1-281-884-1010 Houston, Texas Phone: +1-281-671-1640 Fax: +1-281-671-1735 www.geoilandgas.com/valves *Denotes a trademark of the General Electric Company. Other company names and product names used in this document are the registered trademarks or trademarks of their respective owners. 2017 General Electric Company. All rights reserved. GEA19576C 01/2017