BLUE POWER World quality leader in independent electric power

Similar documents
BLUE POWER. World quality leader in independent electric power

Remote on/off switch Connector for remote on/off switch available on all models. DIP switch for 50/60Hz selection (48/350 model only)

EnErgy. anytime. anywhere. MARINE

ENERGY. ANYTIME. ANYWHERE. AUTOMOTIVE

ENERGY. ANYTIME. ANYWHERE. AUTOMOTIVE

Marine. Energy. Anytime. Anywhere.

OFF-GRID BACK-UP & ISLAND SYSTEMS ENERGY. ANYTIME. ANYWHERE.

AUTOMOTIVE ErE. h yw n E. a ytim n y. a Erg En

MARINE ErE. h yw n E. a ytim n y. a Erg En

Photovoltaic Standalone Plants ECO-FRIENDLY-POWERFUL-SAFE

BMS 12/200 for 12,8 Volt lithium iron phosphate batteries Especially designed for vehicles and boats

Automotive. Energy. Anytime. Anywhere.

Phoenix Multi Inverter/Chargers

Phoenix Inverter

Automotive. Energy. Anytime. Anywhere.

Marine. Energy. Anytime. Anywhere.

QUATTRO. (+34) Skype

OFF-GRID BACK-UP & ISLAND SYSTEMS

Mobility. Energy. Anytime. Anywhere.

OFF-GRID BACK-UP & ISLAND SYSTEMS

Inverter/Chargers. Off-Grid Inverters. Solar charge controllers

Manual. EN Appendix. VE.Bus BMS

:34 1/15 Hub-4 / grid parallel - manual

INVERTER. MECHANICAL DATA Steel with powder paint Dimension (mm) 527 x 228 x 190 Net Weight (kgs) 18 STANDAR. Cont output power at 20ºC. Cos φ 0.

Manual. Handleiding. Manuel. Anleitung. Manual. VE.Bus BMS. ES Appendix

INVERTER/CHARGERS Off-Grid Power Solutions

Power you can rely on

SimpliPhi Power PHI Battery

10A 15A 25A 40A 60A 20A 30A

Hub-4 / grid parallel - manual

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE

More current on board

Using the Phoenix MultiPlus to reduce operating cost of a generator

Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER

Power you can rely on

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

Today. Smart Lithium batteries. MultiPlus-II. 3 phase systems. Firmware updating. Off Grid systems. Marine applications and new products

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Battery Chargers - Phase Three Series

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

All In one uninterruptible power supply solutions

Off-grid, back-up & island systems. Energy. Anytime. Anywhere.

SBC / 2140 / Stage Battery Charger User Manual

Item Number Max Output Current Amps Output Volts Banks Price. Mini & Low Power

Pure Sine Wave Inverter Charger

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Technical Data Sheets

Types batteries. AGM Gel OpZs OpZv Lead Carbon LiFePO4 NCA Saltwater Zinc Bromine Etc,etc, etc, etc, etc, etc,

SSL-1500 (12V/24V/48V) / SSL-3000 (12V/24V/48V)

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Self-consumption & energy storage. Energy. Anytime. Anywhere.

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

CX-SERIES ADVANCED BATTERY CHARGER

Mass Combi Ultra 24/ (230 V)

Sail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers

BlueSolar charge controller MPPT 100/30

ATevo SERIES BATTERY CHARGER

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller

Technical Data Sheets

Technical data sheets

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

1. General Description

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

Technical Data Sheets

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual Solar Charge Controller 3KW

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Technical Data Sheets

User Manual. Solar Charge Controller 3KW

Liebert PowerSure PSI UPS

EMERGENCY VEHICLE BATTERY MANAGER PS2024

Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester. Charge & Testing. Integrated Electronic Solutions

Technical Specification SENTINEL PRO

Technical Data Sheets

Off-grid, backup & island systems. Energy. Anytime. Anywhere.

Eclipse Solar Suitcase

twin engine two battery bank split charge system

IMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array.

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

Self-consumption & energy storage. Energy. Anytime. Anywhere.

EnErgy. anytime. anywhere. MARINE

Product catalog. Professional power systems equipment for renewable energy, back-up power and vehicle applications

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

AT30 SERIES BATTERY CHARGER

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

AT EVO SERIES BATTERY CHARGER

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Engineered power. Inverter-chargers. Inverters. MPPT solar charge controllers. Battery chargers. Battery monitoring.

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Victron Energy USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG PALLAS-TG 12/50 SKYLLA-TG 24/30 SKYLLA-TG 24/50 SKYLLA-TG 24/30 110V TITAN 48/25

SMART 1000 / 2000 SERIES

Transcription:

BLUE POWER World quality leader in independent electric power

About Victron Energy With over 30 years experience, Victron Energy enjoys an unrivalled reputation for technical innovation, reliability and quality, and is a world leader in the supply of self-supporting electric power. Our products have been designed to meet the most demanding situations faced by a diversity of craft, recreational and commercial alike, whilst we also cater for many other industrial and commercial applications. Our product range includes sine wave inverters and inverter/ chargers, battery chargers, DC/DC converters, transfer switches, Gel and AGM batteries, alternators, battery monitors, complete network solutions and many other innovative solutions. [ Products range ] Sinewave Inverters Combined Inverter/chargers Automatic Battery Chargers DC DC Converters Transfer Switches Deep Cycle Gel and AGM batteries High Power Alternators Battery Monitors DC Distribution Units Control and Distribution Panels Battery Isolators Shore Power Connection Kits System Monitoring and Control Solar Panels [ Applications ] Solar and wind power systems Yachts and commercial vessels Special vehicles such as live broadcasting vehicles, ambulances, service vans, trains, caravans etc Industrial Telecom Emergency power supply Remote areas where there is no continuous supply

phoenix inverter 230VAC/50HZ [ 12V: 180-5000 VA ] [ 24V: 180-5000 VA ] [ 48V: 180-5000 VA ] characteristics 230VAC/50HZ SinusMax - Superior engineering True sine wave inverter with optimised efficiency but without compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact dimensions, light in weight and capable of supplying power, problem-free, to any load. Extra start-up power A unique feature of the SinusMax technology is very high start-up power. Phoenix inverters, however, are well suited to power up difficult loads such as refrigeration compressors, electric motors and similar appliances. Virtually unlimited power thanks to parallel and 3-phase operation capability Up to 10 units Phoenix 24/5000 can operate in parallel to achieve 50KVA power output. Operation in 3-phase configuration is also possible. To transfer the load to another AC source: the automatic transfer switch If an automatic transfer switch is required on models rated at 1200 VA or more, we recommend using the Phoenix Multiplus instead. The switch is included in these products and the charger function of the Multi can be disabled. For our lower power models we recommend the use of our Filax Automatic Transfer Switch. Computers and other electronic equipment will continue to operate without disruption because both the Filax and the Phoenix Multi feature a very short switchover times (less than 20 milliseconds). Computer interface All models rated at 1200 VA or more have a RS-485 computer interface. Together with the VEConfigure software, all parameters of the inverters can be customised. The inverters can also be connected to VEnet, the power control network of Victron Energy. ACCESSORIES BMV-600-S Battery Monitor Phoenix Inverter Control (PIV) Computer controlled operation and monitoring (Victron Interface Mk2) Battery Alarm An excessively high or low battery voltage is indicated by an audible and visual alarm, and a relay for remote signalling. Phoenix 12 Volt inverter 14 Volt 48 Volt 12/180 24/180 Input voltage range (VCD) 10.5-15.5 21.0-31.0 42.0-62.0 12/350 24/350 48/350 10.5-15.5 21.0-31.0 42.0-62.0 12/750 24/750 48/750 10.5-15.5 21.0-31.0 42.0-62.0 C12/1200 C24/1200 9.5-16 19.5-32.2 C12/1600 C24/1600 9.5-16 19.5-33 C12/2000 C24/2000 9.5-16 19.5-33 12/3000 24/3000 48/3000 9.5-16 19.5-33 38-66 24/5000 48/5000 9.5-16 19.5-33 38-66 Cont. output power at 25 C (VA) 180 350 750 1200 (3) 1600 (3) 2000 (3) 3000 (3) 5000 (3) Cont. power at 25 C / 40 C (W) 175 / 150 300 / 250 700 / 650 1000 / 900 (4) 1300 / 1200 (4) 1600 / 1450 (4) 2500 / 2000 (4) 4500 / 4000 (4) Peak power (W) 200 500 1400 2400 2300 4000 6000 10000 (W) 3000 Max. Efficiency 12/24/48 V (%) 91 / 92 / 92 90 / 91 / 92 91 / 93 / 94 93 / 94 93 / 94 93 / 94 93 / 94 / 95 94 / 95 Zero-load power 12/24/48V (w) 2.2 / 3.0 / 4.0 3.0 / 3.5 / 4.0 12 / 12 / 12 8 / 11 8 / 11 10 / 10 15 / 15 / 16 25 Zero-load power in AES mode n.a. n.a. 3/4/5 5/8 5/8 8/10 10/10/12 20/20 Muti purpose relay relay relay relay relay x2 relay x2 driver or relay (2) Protection (4) a,b,d,h a,b,d,h a,b,d,h a,b,d,c,d,f,g,h a,b,d,c,d,f,g,h a,b,d,c,d,f,g,h a-h a-h Common Characteristics Output: 230 V ± 2% /50/60 Hz ± 0,2% (switch selectable) Operating temperature range: -20 to +50 C Humidity: max 95% ENCLOSURE Material & Colour Aluminium (blue RAL 5012) Battery-connection 1) 1) Screw conn. 1) 1) M8 bolts M8 bolts 4 M8 bolts 230 V AC-connection IEC-320 (IEC-320 plug included) or Schuko G-ST18i G-ST18i Spring-clamp Screw-clamp Protection category IP20 IP20 IP20 IP21 IP21 IP21 IP21 IP21 Weight (kg) 2.7 3.5 2.7 10 10 12 18 30 Dimensions (hxwxd in mm) 72x132x200 72x155x237 72x180x295 375x214x110 375x214x110 520x255x125 362x258x218 444x328x240 ACCESSORIES Remote panel (RS485) (PIV) (PIV) (PIV) (PIV) (PIV) Remote on-off switch Automatic transfer switch FILAX FILAX FILAX Phoenix Multi Quattro STANDARDS Safety EN 60950 EN 60335-1 Emission / Immunity EN 55014-1 / EN55014-2 Automotive Directive 95/54/EC and 2004/104/EC 1) Battery cables of 1.5 meter 2) Multipurpose relay which can be set for general alarm, DC under voltage or genset starts signal function 3) Suitable for parallel and 3-phase 4) Protection a. Output short circuit b. Overload c. Battery voltage too high d. Battery voltage too low e. Battery reverse polarity detection f. 230 V AC on inverter output g. Input voltage ripple too high h. Temperature too high

phoenix inverter 120VAC/60HZ [ 12V: 180-5000 VA ] [ 24V: 180-5000 VA ] characteristics 120VAC/60HZ SinusMax - Superior engineering True sine wave inverter with optimised efficiency but without compromise in performance. Employing hybrid HF technology, the result is a top quality product with compact dimensions, light in weight and capable of supplying power, problem-free, to any load. Extra start-up power A unique feature of the SinusMax technology is very high start-up power. Phoenix inverters, however, are well suited to power up difficult loads such as refrigeration compressors, electric motors and similar appliances. Virtually unlimited power thanks to parallel and 3-phase operation capability Up to 6 units Phoenix 24/3000 can operate in parallel to achieve 18KVA power output. Operation in 3-phase configuration is also possible. To transfer the load to another AC source: the automatic transfer switch If an automatic transfer switch is required on models rated at 1200 VA or more, we recommend using the Phoenix Multiplus instead. The switch is included in these products and the charger function of the Multi can be disabled. For our lower power models we recommend the use of our Filax Automatic Transfer Switch. Computers and other electronic equipment will continue to operate without disruption because both the Filax and the Phoenix Multi feature a very short switchover times (less than 20 milliseconds). ACCESSORIES BMV-600 S Battery Monitor Phoenix Inverter Control (PIV) Computer controlled operation and monitoring (Victron Interface Mk2) Phoenix 12 Volt inverter 24 Volt 12/180 24/180 12/350 24/350 12/750 24/750 Input voltage range (VCD) 10.5-15.5 / 21.0-31.0 Cont. output power at 25 C (VA) 180 350 750 Cont. power at 25 C / 40 C (W) 175 / 150 300 / 250 700 / 650 Peak power (W) (W) 350 700 1400 Max. Efficiency 12/24/48 V (%) 87 / 88 89 /89 91 / 93 Zero-load power 12/24/48V (w) 2.6 / 3.8 3.1 / 5.0 14 / 14 Zero-load power in AES mode n.a. 3 / 4 / 5 Protection (5) a - g Common Characteristics Output: Output: 120 V ± 2% / 60 Hz ± 0,2% (switch selectable) Operating temperature range: 0-122 F Humidity: max 95% ENCLOSURE Material & Colour Aluminium (blue RAL 5012) Battery-connection 1) 1) Screw conn. 230 V AC-connection NEMA5-15R Protection category IP20 IP20 IP20 Weight (kg) 2.7 / 5.4 3.5 / 7.7 2.7 / 5.4 Dimensions (hxwxd in mm) 72x132x200 72x155x237 72x180x295 ACCESSORIES Remote panel (RS485) Remote on-off switch Automatic transfer switch FILAX FILAX FILAX STANDARDS Safety EN 60950 EN 60950 EN 60950 Emission / Imunnity EN 55014-1 / EN55014-2 Automotive Directive 95/54/EC and 2004/104/EC Battery Alarm An excessively high or low battery voltage is indicated by an audible and visual alarm, and a relay for remote signalling. 1) Battery cables of 1.5 meter 2) Relay driver: open Collector 66V 3) Multipurpose relay which can be set for general alarm, DC under voltage or genset starts signal function 4) Suitable for parallel and 3-phase 5) Protection a. Output short circuit b. Overload c. Battery voltage too high d. Battery voltage too low e. Battery reverse polarity detection f. 230 V AC on inverter output g. Input voltage ripple too high h. Temperature too high

Multiplus 230VAC/50HZ [ 12V: 800-3000 VA ] [ 24V: 800-8000 VA ] [ 48V: 3000-10000 VA ] characteristics 230VAC/50HZ Multi-functional, with intelligent mains and generator power management The multi gets its name from the multiple functions it can perform. It is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Uninterrupted AC power (UPS function) In the event of a grid failure, or mains or generator power being disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. PowerControl - Dealing with limited generator, shore side or grid power With the Phoenix Multi Control Panel a maximum generator or shore current can be set. The Multi will then take account of other AC loads and use whatever is extra for charging, this preventing the generator or mains supply from being overloaded. PowerAssist - Boosting the capacity of grid or generator power, an innovative feature of the MultiPlus This feature takes the principle of PowerControl to a further dimension allowing the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the Phoenix MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. Four stage adaptive charger and dual bank battery charging The main output provides a powerful charge to the battery system by means of advanced adaptive charge software that fine-tunes the three stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. In addition to this, the Multi will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery. ACCESSORIES VEBus digitial panel This is a remote control and monitoring panel for the Phoenix Multiplus Computer controlled operation and monitoring (Victron Interface Mk2) Blue Power panel VE.Net / VE.Bus panel Victron Global Remote Multiplus 12V / 24V / 48V C12/800/16 C24/800/35 C12/1200/50 C24/1200/25 C12/1600/70 C24/1600/40 C12/2000/80 C24/2000/50 12/3000/120 24/3000/70 48/3000/35 24/5000/120 48/5000/70 24/8000 48/8000 48/10000 PowerControl / PowerAssist Yes / Yes Transfer switch (A) 16 30 16 or 50 50 100 100 INVERTER Input voltage range (VCD) 9,5 17 V 19 33 V 38 66 V Output 230 V ± 2% /50 Hz ± 0,1% Frequency: 50 Hz ± 0.1 % Cont. output power at 25 C (VA) (5) 800 1200 1600 2000 3000 5000 8000 10000 Cont. output power at 25/40 C (W) 700 / 650 1000 / 950 1300 / 1200 1600 / 1450 2500 / 2000 4250 / 3350 7000 / 6300 9000 / 8000 Peak power (W) 1600 2400 3000 4000 6000 10.000 16000 20000 Maximum efficiency (%) 92 / 94 93 / 94 93 / 94 / 95 94 / 95 95 / 96 96 Zero-load power (W) 8 / 10 9 / 11 15 / 15 / 16 25 / 25 30 / 35 35 Zero-load power in AES Modus 5 / 8 7 / 9 10 / 10 / 12 20 / 20 25 / 30 30 Zero-load power in Search Modus 2 / 3 3 / 4 4 / 5 / 5 5 / 6 8 / 10 10 charger AC input 187-265 VAC, 45-55 HZ, Power factor:1 Charge voltage absorption (V DC) 14,4 / 28,8 / 57,6 Charge voltage float (V DC) 13,8 / 27,6 / 55,2 Storage mode (V DC) 13,2 / 26,4 / 52,8 Charge current starter battery (A) 4 (Only by the 12V and 24V) Battery temperature sensor Yes General Auxiliary output (A) (5) n.a. Yes (10A) Yes (25A) 50 50 Multi purpose relay driver or relay relay driver (7) relay 3x relay Protection (5) a - g VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration General purpose com. port (7) 1x 1x 3x 3x Common Characteristics Operating temp. range: -20-50 C (fan assisted cooling) Humidity (non condesing) : max 95% enclosure Common Characteristics Material & Colour: aluminum (blau RAL 5012) Protection category: IP 21 Battery-connection Battery cabels 1,5 m M8 Studs 230 V AC-connection G-ST18i Stecker Spring-clamp Screw-clamp Weight (kg) 10 12 18 30 41 45 Dimensions (hxwxd in mm) 375x214x110 520x255x125 362x258x218 444x328x240 470x350x280 470x350x280 STANDARDS Safety EN 60335-1, EN60335-2-29 Emission / Immunity EN55014-1, EN 61000-3-2 / EN 55014-2, EN 61000-3-3 Automotive Directive 95/54/EC and 2004/104/EC 1) Can be adjusted to 60 HZ; 120 V 60 Hz on, request 2) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) input voltage ripple too high 3) Non linear load, crest factor 3:1 4) At 25 C ambient 5) Switches off when no external AC source available, Available on 3kVA models with 50A transfer switch only 6) Programmable relay that can a. o. be set for general alarm, DC undervoltage or genset start /stop function, AC rating: 230V/4A DC rating: 4A up to 35VDC, 1A up to 60VDC 7) Open collector output 66V 40mA

Quattro 230VAC/50HZ [ 12V: 3000 VA ] [ 24V: 3000 VA ] [ 12V: 5000 VA ] [ 24V: 5000 VA ] [ 48V: 5000 VA ] [ 24V: 8000 VA ] [ 48V: 8000 VA ] [ 48V: 10000 VA ] characteristics 230VAC/50HZ Two AC inputs with integrated transfer switch Two AC outputs The main output has no-break functionality. The second output is live only when AC is available on one of the inputs of the Quattro. Virtually unlimited power thanks to parallel operation Up to 6 Quattro s can operate in parallel. Three phase capability Three units can be configured for three-phase output. PowerControl - Dealing with limited generator, shore-side or grid power PowerAssist - Boosting shore or generator power Solar energy: AC power available even during a grid failure The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems. A grid connected PV system will shut down when the grid fails! Not anymore with a Quattro and batteries Quattro 12/3000/120 24/3000/70 12/5000/200 24/5000/120 48/5000/70 24/8000 48/8000 48/10000 PowerControl / PowerAssist Yes / Yes Integrated Transfer switch Input voltage range: 187-265 VAC Input frequency: 45-55 Hz Power factor: 1 Maximum feed through current (A) 50/30 30/30 / 50/30 2x100 2x100 inverter Input voltage range (V DC) 9.5-17 / 19-33 9.5-17 / 19-33 / 38 66 19-33 / 38-66 38-66 Output (1) Output voltage: 230 VAC ± 2% Cont. output power at 25 C (VA) (2) 3000 5000 8000 10000 Cont. output power at 25 C (W) 2500 4250 7000 9000 Cont. output power at 40 C (W) 2000 3350 6300 8000 Peak power (W) 6000 7500 / 7800 16000 20000 Maximum efficiency (%) 92 / 94 94 / 95 95 / 96 96 Zero-load power (W) 15 30 30 / 35 35 Load shedding output 0 / 25 10 / Switches off when no external AC source available charger Charge voltage absorption (V DC) 14.4 / 28.8 14.4 / 28.8 / 57.6 28.8 / 57.6 57.6 Charge voltage float (V DC) 13.8 / 27.6 13.8 / 27.6 / 55.2 27.6 / 55.2 55.2 Storage mode (V DC) 13.2 / 26.4 13.2 / 26.4 / 52.8 26.4 / 52.8 52.8 Charge current house battery (A) 120 / 70 200 / 120 / 70 200 / 110 140 Charge current starter battery (A) 4 (12V and 24V models only) Battery temperature sensor Yes general Multi purpose relay (1) 1x 3x / 1x / 1x 3x 3x General purpose com. port (7) 1x 2x / 1x / 1x 2x 2x Common Characteristics (3) Operating temp.: -20 to +50 C (fan assisted cooling) Humidity (non condensing) : max 95% / a-f enclosure Common Characteristics Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21 Battery-connection Four M8 bolts (2 plus and 2 minus connections) 230 V AC-connection Screw clamp 13 mm² (AWG 6) Weight (kg) 19 30 41 45 Dimensions (hxwxd in mm) 362x258x218 444x328x240 470 x 350 x 280 standards Safety EN 60335-1, EN 60335-2-29 Emissions / immunity EN 55014-1, EN 61000-3-2 / EN 55014-2, EN61000-3-3 Automotive Directive 2004/104/EC 1) Multipurpose relay which can be set for general alarm, DC under voltage or genset starts signal function 2) Suitable for parallel and 3-phase 3) Protection a. Output short circuit b. Overload c. Battery voltage too high d. Battery voltage too low e. Battery reverse polarity detection f. 230 V AC on inverter output g. Input voltage ripple too high h. Temperature too high

phoenix Multiplus/quattro 120VAC/60HZ [ 12V: 2000-5000 VA ] [ 24V: 2000-5000 VA ] characteristics 120VAC/60HZ Multi-functional, with intelligent shore and generator power management The multi gets its name from the multiple functions it can perform. It is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Uninterrupted AC power (UPS function) In the event of a grid failure, or mains or generator power being disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. Virtually unlimited power thanks to parallel operation and three phase capability Up to 6 Multi s can operate in parallel to achieve higher power output. Three units of the same model can be configured for three-phase output. PowerControl - Dealing with limited generator or grid power With the Phoenix Multi Control Panel a maximum generator or shore current can be set. The Multi will then take account of other AC loads and use whatever is extra for charging, this preventing the generator or shore supply from being overloaded. PowerAssist - Boosting the capacity of shore or generator power, an innovative feature of the MultiPlus This feature takes the principle of PowerControl to a further dimension allowing the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the Phoenix MultiPlus/Quattro will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. Four stage adaptive charger and dual bank battery charging The main output provides a powerful charge to the battery system by means of advanced adaptive charge software that fine-tunes the three stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. In addition to this, the Multi will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery. 120Vac 120Vac 120Vac 120Vac 230Vac 230Vac L1-1 L2-1 N 1 GND L1-2 L2-2 N 2 GND Input 1 Input 2 Output L1 ( no break) L 2 N GND 120VAC split-phase version Input 1 L1-1 N 1 GND L1-2 N 2 GND Input 2 Output L1 ( no break) N GND 230 VAC single-phase version 120Vac 120Vac 230Vac Multiplus 12V / 24V C 12/2000/80-30 120V 12/3000/120-50 120V 24/3000/70-50 120V Quattro 24/5000/120-2x60 120/240V PowerControl Yes PowerAssist Yes Transfer switch (A) 30 A 50 A 60 A inverter Input voltage range (V DC) 9.5-17V 19-33V Output Output voltage: 120 VAC ± 2% Frequency: 60 Hz ± 0,1% Cont. output power at 25 C (VA) (2) 2000 3000 5000 Cont. output power at 25/40 C (W) 1600/1450 2500/2000 4250/3350 Peak power (w) 4100 6000 7500 Maximum efficiency (%) 93/94 93/94 94 Zero-load power (W) 10/10 15/15 30 charger AC input 120V or 120/240V Input voltage range: 95-140 VAC Input frequency: 45 65 Hz Power factor:1 Charge voltage absorption (V DC) 14.4/28.8 Charge voltage float (V DC) 13.8/27.6 Storage mode (V DC) 13.2/26.4 Charge current house battery (A) 80/50 120/70 120 Charge current starter battery (A) 4 Battery temperature sensor Yes general Multi purpose relay driver or relay (1) Relay Protection (3) a-h Common characteristics Operating temp. range: 0-120 F (fan assisted cooling) Humidity (non condensing): max 95% enclosure Common Characteristics Material & Colour: aluminum (blue RAL 5012) Protection category: IP 21 Battery-connection M8 Studs Four M8 Blots (2+, 2-) 230 V AC-connection Spring-clamp Screw-clamp Protection category IP 21 Weight (kg) 13 18 30 Dimensions (hxwxd in mm) 520x255x120 362x258x218 444x328x240 standards Safety EN 60335-1, EN 60335-2-29 Emission / Immunity EN 55014-1, EN 55014-2/EN61000-3-2, EN 61000-3-3 Automotive Directive 95/54/EC abd 2004/104/EC 1) Multipurpose relay which can be set for general alarm, DC under voltage or genset starts signal function 2) Suitable for parallel and 3-phase 3) Protection a. Output short circuit b. Overload c. Battery voltage too high d. Battery voltage too low e. Battery reverse polarity detection f. 230 V AC on inverter output g. Input voltage ripple too high h. Temperature too high

blue power battery charger ip20 [ 12V: 7-15 A ] [ 24V: 5-8 A ] characteristics Universal input: 90-265 VAC or 90-350 VDC The charger will operate on whatever supply is available. Adaptive 4-stage charge characteristics: bulk - absorption - float - storage The Blue Power charger features a microprocessor controlled adaptive battery management. The adaptive feature will automatically optimise the charging process relative to the way the battery is being used. Less maintenance and aging when the battery is not in use: the Storage Mode The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (13,2 V for a 12 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to equalize the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. Protected against overheating and silent fan cooling Output current will reduce as temperature increases up to 60 C but the Blue Power charger will not fail. The load and temperature controlled fan is practically inaudible. Two LED s for status indication Yellow LED: bulk charge (blinking fast), absorption (blinking slow). float (solid) Green LED: power on Blue power charger IP 20 12/7 12/10 12/15 24/5 24/8 Input voltage range 90-265 VAC, 90-350 VDC Frequency 45-65 or DC Charge voltage absorption (V DC) 14.4 28.8 Charge voltage float (V DC) 14 28 Charge voltage storage (V DC) 13.2 26.4 Charge current (A) 7/10/15 5/8 Charge characteristic 4-stage adaptive Minimum battery capacity (Ah) 24/36/55 16/24 Can be used as power supply Yes Protection Battery reverse polarity (fuse in battery cable) Output short circuit, over temperature Operating range -20 tot 60 C Humidity: Max 95% enclosure Material & Colour Aluminium (blue RAL 5012) Battery-connection Black and red cable of 1,5 meter 230 V AC-connection Cable of 1,5 meter with Europe class 1 plug (CE certified) Protection category IP20 Weight (kg) 1.3 Dimensions (hxwxd in mm) 50x85x200 standards Safety EN60335-1, EN60335-2-29 Emission EN55014-1, EN61000-3-2 Immunity EN55014-2, EN61000-3-3

blue power battery charger IP65 [ 12V: 7-17 A ] [ 24V: 3-12 A ] characteristics Completely encapsulated: waterproof, shockproof and ignition protected Water, oil or dirt will not damage the Blue Power charger. The casing is made of cast aluminium and the electronics are molded in resin. Protected against overheating Can be used in a hot environment such as a machine room. Output current will reduce as temperature increases up to 60 C, but the Blue Power charger will not fail. Automatic three stage charging Once the absorption voltage has been reached to a low break point current (see specifications), or after a 20 hour absorption period. The battery is therefore effectively protected against overcharging and can remain permanently connected to the charger. The charger will automatically reset and start a new charge cycle after interruption of the AC supply. Two LED s for status indication Yellow LED: battery being charged Green LED: float charge, the battery is charged Blue Power charger 12/7 12/17 24/3 24/12 Input voltage range (V AC) (1) 200-265 Frequency (Hz) 45-65 Charge voltage absorption (V DC) 14.4 28.8 Charge voltage float (V DC) 13.7 27.2 Charge current (A) 7 17 3 12 Charge characteristic 3 stage with max. 20 hours absorption time Minimum battery capacity (Ah) 15 35 6 24 Breakpoint current (A) 0.7 1.7 0.3 1.2 Can be used as power supply Yes Protection Battery reverse polarity (fuse in battery cable) Output short circuit, over temperature Operating range -20 to 60 C, Humidity Max: 100% enclosure Material & Colour Aluminium (blue RAL 5012) Battery-connection Black and red cable of 1,5 meter 230 V AC-connection Cable of 1,5 meter with Europe class 1 plug (CE-certified) Protection category IP 65 Weight (kg) 1.1 1.4 1.1 1.4 Dimensions (hxwxd in mm) 43x80x155 47x99x193 43x80x155 47x99x193 standards Safety EN60335-1, EN 60335-2-29 Emission EN55014-1, EN61000-3-2 Immunity EN55014-2, EN61000-3-3 1) 120V / 60 Hz available

phoenix battery charger [ 12V: 30-50 A ] [ 24V: 16-25 A ] characteristics Adaptive 4-stage charge characteristic: bulk - absorption - float - storage The Phoenix charger features a microprocessor controlled adaptive battery management system that can be preset to suit different types of batteries. The adaptive feature will automatically optimise the process relative to the way the battery is being used. The right-amount of charge: adaptive charge When only shallow discharges occur (a yacht connected to shore power for example) the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode (see fig1. below) If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Phoenix charger will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached (see the charge curve between 14,4 V and 15,0 V in fig.1 below). Less maintenance and aging when the battery is not in use: the Storage mode (see fig.1 below) The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (13,2 V for 12 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to equalize the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Phoenix charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. Battery voltage sense In order to compensate for voltage loss due to cable resistance, Phoenix chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Computer interface Every Phoenix Charger is ready to communicate with a computer through its RS-485 data port. Together with our VEConfigure software, all parameters of the chargers can be customised. The chargers can also be connected to VENet, or to other computerised monitoring control systems. Fig. 1 ACCESSORIES Battery Monitor Phoenix Charger Control Phoenix charger 12V/24V 12/30 24/16 12/50 24/25 Input voltage range 90-265 VAC, 90-400 VDC Frequency (Hz) 45-65, PF:1 Charge voltage absorption (V DC) 14.4 / 28.8 Charge voltage float (V DC) 13.8 / 27.6 Storage mode (V DC) 13.2 / 26.4 Battery bank 3 Charge current house batt. (A)(2) 30/16 50/25 Charge current starter batt. (A) 4 Charge characteristics 4 stage adaptive Battery capacity (Ah) 100-400 100-200 Temperature sensor Yes Can be used as power supply Yes Forced cooling Yes Protection (1) a,b,c,d 200-800 100-400 Common characteristics Temperature: -20 to 60 C (0-140 F) Max humidity: 95% enclosure Material & Colour Aluminium (blue RAL 5012) Battery-connection M6 Studs 230 V AC-connection Screw-clamp 4mm² Protection category IP21 Weight (kg) 3.8 Dimensions (hxwxd in mm) 350x200x108 standards Safety EN60335-2-29 Emission EN55014, EN61000-3-2, EN61000-3-3 Immunity EN55014-2 Vibration IEC68-2-6: 10-150Hz/1.0G Automotive directive 95/54/EC Computer controlled operation and monitoring (Victron interface Mk2b) Battery Alarm An excessively high or low battery voltage is indicated by an audible and visual alarm. 1) Protection a. Output short circuit b. Battery reverse polarity detection c. Battery voltage too high d. Temperature too high 2) Up to 40 C ambient

skylla TG battery charger [ 24V: 30-50-80-100 A ] [ 48V: 25-50 A ] characteristics Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Over voltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Controlled charging Every TG charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristics and charges more rapidly than other processes. Use of TG chargers as a power supply As a result of the perfectly stabilized output voltage, a TG charger can be used as a power supply if batteries or large buffer capacitors not available. Two outputs to charge 2 battery banks The TG chargers feature 2 isolated outputs. The second output, limited to approximately 4 A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. ACCESSORIES Battery Monitor Skylla TG GMDSS Skylla Control GMDSS panel Skylla 24V / 48V 24/30 TG 24/30 GMDSS 24/50 TG 24/50 GMDSS 24/50 TG 3 phase 24/80 TG 24/100 TG 24/100 TG 3 phase 48/25 TG 48/50 TG Input voltage 185-265VAC, 320-450VAC or 180-400VDC (3) Frequency (Hz) 45-65 Charge voltage absorption (VDC) 28.5 57 Charge voltage float (VDC) 26.5 53 Battery capacity (Ah) 150-300 250-500 400-800 500-1000 125-250 250-500 Charge current house batt. (A) (2) 30 50 75 100 25 50 Charge current starter batt. (A) 4 n.a. Charge characteristics IUoUo Temperature sensor Can be used as power supply Potential free contacts Protection (1) a,b,c,d Common characteristics Temperature: -20 to 60 C (0-140 F) Max humidity: 95% enclosure Material & Colour Aluminium (blue RAL 5012) Battery-connection M8 Studs 230 V AC-connection Screw-clamp 2,5 mm² (AWG 6) Protection category IP21 Weight (kg) 5.5/6 5.5/13 10 10/23 5.5 10 Dimensions (hxwxd in mm) 365x250x147 365x250x147 365x250x257 365x250x257 365x250x147 365x250x257 365x250x257 515x260x265 standards Safety EN60335-2-29 Emissions EN55014, EN61000-3-2, EN61000-3-3 Immunity EN55014-2 Automotive divective 95/54/EC 1) Protection a. Output short circuit b. Battery reverse polarity detection c. Battery voltage too high d. Temperature too high 2) Up to 40 C ambient Wide input voltage 90-265 VAC and GL approval model available

CENTAUR BATTERY CHARGER [ 12V: 20-30-40-50-60-80-100-200 A ] [ 24V: 16-30-40-60-80-100 A ] characteristics Quality without compromise Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of adverse environments: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed, by automatic reduction of output current under extreme environmental conditions. Universal 90 to 265 Volt input voltage range All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz. Three outputs that each can supply the full output current Three isolated outputs to simultaneously charge 3 battery banks. Each output is capable to supply the full rated current. Three stage charging, with temperature compensation The Centaur charges at bulk rate until the output has reduced to 70% of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with 2 mv/ C (1mV/ F) per cell. ACCESSORIES Battery Monitor Battery Alarm An excessively high or low battery voltage is indicated by an audible and visual alarm. 1. Fasten the separate mounting plate (A) to the wall where you want to place the battery charger, and simply hook up the Centaur. 2. Secure the bottom of the backside (B) to the wall. Centaur Charger 12/20 12/30 24/16 Common characteristics Charge voltage 14.3 / 28.5 (1) absorption (VDC) Charge voltage 13.5/27 (1) float (VDC) Output banks 3 Recommended battery capacity (Ah) Charge current (A)(2) Total output ammeter Charge characteristics Temperature sensor Forced Cooling Ignition protected Protection 12/40 12/50 12/60 24/30 12/80 24/40 12/100 24/60 24/80 Input voltage: 90-265 VAC or 90-400 VDC Input frequency: 45-65 Hz Power factor: 1 80-200 120-300 45-150 160-400 200-500 240-600 120-300 320-800 160-400 400-1000 240-600 320-800 12/200 24/100 800-2000 400-1000 20 30/16 40 50 60/30 80/40 100/60 80 200/100 Yes IUoUo (Three stage charging) Internal, -2mV / C (-1mV / F) per cell Yes, temperature and current controlled fan Yes Output short circuit, over temperature Operating range Temperature: -20 to 60 C (0-140 F) Humidity max: 95% enclosure Material & Colour Aluminium (blue RAL5012) AC-connection Screw-clamp 4mm² (AWG 6) Batteryconnection IP21 Protection category M6 Studs M8 Studs Weight kg (lbs) 3.8 5 12 16 Dimension 355x215x110 426x239x135 505x255x130 505x255x230 (hxwxd in mm) standards Safety EN 60335-2-29, UL 1236 Emission EN 55014, EN61000-3-2, EN 61000-3-3 Immunity EN 55014-2 1) Standard setting. Optium charge/float voltages for Flooded Lead-acid, Gel-Cell or AGM batteries selectable by dip switch. 2) Up to 40 C (1oo F) ambient. Output will reduce to approximately 80% of nominal at 50 C (120 F) and 60% of nominal at 60 C (140 F)

orion DC/DC converter characteristics Possibly the widest range on the market! An ever-increasing is being used on vehicles and industrial systems. Because most low-voltage equipment is designed for 12 Volts, Victron Energy supplies DC/DC converters which deliver a stable 12 Volt supply from a 24 Volt system. These products are also distinguished by high efficiency, together with absolute safety. An inferior supply can cause irreparable damage to your 12 Volt system, but the use of an Orion voltage converter prevents problems of that type. Next to converters from 24 V to 12 V, a wide range of other models available. Battery charger The Orion 24/12-20 and 24/12-30 can also be used as a 13.8 Volt battery charger for a 12 Volt starter or accessory battery in an otherwise 24 V system. To charge a 24 V battery from a 12 V system the Orion 12/27,6-12 can be used. The output voltage of this model can be adjusted with a potentiometer. A super wide input range buckboost regulator: The Orion 7-35/12-3 is an isolated converter with a very wide input range, suitable for both 12 V and 24 V systems, and a fixed 12,6 V output. Non isolated converters Orion 24/12-5 Orion 24/12-8 Orion 24/12-12 Orion 24/12-20 Orion 24/12-30 Orion 24/12-60 Orion 12/24-7 Orion 12/24-10 Input voltage range (V) 18-35 18-35 20-35 20-35 20-35 20-35 9-18 9-18 Output voltage (V) 13.2 13.2 13.2 13.8 13.8 13.8 24 24 Max. output current (A) 5.5 8 12 20 30 60 7 10 Fan assisted cooling no no no no yes yes no no (temp. Controlled) Galvanic isolation no no no no no no no no Off load current <5mA <5mA <5mA appr. 25mA appr. 25mA appr. 50mA <15mA <15mA Temperature increase after 30 minutes at full load ( C) 30 20 30 25 33 33 30 30 Weight (kg) 0.17 0.25 0.26 0.48 0.6 1.2 0.3 0.4 Dimensions (hxwxd in mm) 49x88x68 49x88x98 49x88x98 49x88x126 49x88x151 88x100x180 49x88x98 49x88x126 Note: two units orion 24/12-60 can be connected in parallel to obtain a 120A converter Isolated converters Orion xx/yy-100w Orion xx/yy-200w Orion xx/yy-360w Power rating (W) 100 (12,5V/8A or 24V/4A) 200 (12,5V/16A or 24V/8A) 360 (12,5V/30A or 24V/15A) Galvanic isolation yes yes yes Temperature increase after 25 30 30 30 minutes at full load (C) Fan assisted cooling (temp. Controlled) no yes yes Weight (kg) 0.5 0.6 1.4 Dimensions (hxwxd in mm) 49 x 88 x 152 49 x 88 x 182 64 x 163 x 160 Input voltage (xx) 12 V (9-18V) or 24 V (20-35 V) or 48 V (30-60 V) or 96 V (60-120 V), 110 V Output voltage (yy) 12,5 V or 24 V Isolated 24V battery charger: Orion 12/27,6-12 Isolated buck-boost regulator: Orion 7-35/12-3 Input 9-18 V, output 27,6 V, current limit 12 A, fan assisted cooling Output voltage adjustable with potentiometer Weight 1,4 kg, dimensions 64 x 163 x 160 mm Input 7-35 V, output 12,6 V current limit 3 A, derate current linearly from 3 A at 18 V to 1,5 A at 7 V Weight 1,4 kg, dimensions 64 x 163 x 160 mm Common characteristics Output voltage stability 2 % (Orion 12/24-7 and Orion 12/24-10: + 0% / -5%) Output voltage tolerance 3% Output noise < 50 mv rms Off load current < 25 ma (isolated converters) Efficiency Non isolated: appr. 92% Isolated: appr. 85% Isolation > 400 Vrms between input, output and case (isolated products only) Operating temperature - 20 to + 30 C. Derate linearly to 0 A at 70 C Humidity Max 95% non condensing Casework Anodised aluminium Connections 6.3 mm push-on flat blade connectors protection Overcurrent Short circuit proof Overheating Reduction of output voltage Reverse polarity conn Fuse and reverse connected diode across input Overvoltage Varistor (also protects against load dump) standards Emission EN 50081-1 Immunity EN 50082-1 Automotive Directive 95/45/EC

BAttery isolator ARGO DIODE BATTERY ISOLATORS Diode battery isolators allow simultaneous charging of two or more batteries from one alternator, without connecting the batteries together. Discharging the accessory battery for example will not result in also discharging the starter battery. The Argo battery isolators feature a low voltage drop thanks to the use of Schottky diodes: at low current the voltage drop is approximately 0,3 V and at the rated output approximately 0,45 V. All models are fitted with a compensation diode that can be used to slightly increase the output voltage of the alternator. This compensated for the voltage drop over the diodes in the isolater. Argo Battery Isolator 702SC 903SC 1202SC 1203SC 1602SC 1603SC Maximum charge (A) 50 70 100 100 130 130 Maximum alternator 70 90 120 120 160 160 current (A) Number of batteries 2 3 2 3 2 3 Connection M6 Studs M8 Studs Connection M4 compensation diode Weight kg (lbs) 0,8 (1.8) 1,2 (2.6) 0,8 (1.8) 1,2 (2.6) 1,2 (2.6) 1,5 (3.3) R B+ B+ victron energy Diode Battery Isolator CE Dimensions H x B x L in mm (H x B x L in mm) 60 x 120 x 80 (2.4 x 4.7 x 3.2) 60 x 120 x 150 (2.4 x 4.7 x 6.0) 60 x 120 x 100 (2.4 x 4.7 x 3.9) 60 x 120 x 150 (2.4 x 4.7 x 6.0) 60 x 120 x 200 (2.4 x 4.7 x 7.9) ARGO FET Battery Isolators: no voltage loss Similarly to diode battery isolators, FET isolators allow simultaneous charging of two or more batteries from one alternator (or a single output battery charger), without connecting the batteries together. Discharging the accessory battery for example will not result in also discharging the starter battery. In contrast with diode battery isolators, FET isolators have virtually no voltage loss. Voltage drop is less than 0,02 Volt at low current and averages 0,1 Volt at higher currents. The new Argofet isolators have a special current limited energize input that will power the B+ when the engine run/stop switch is closed. Argo FET Battery Isolator Argofet 100-2 Argofet 100-3 Argofet 200-2 Argofet 200-3 Maximum charge (A) 100 100 200 200 Maximum alternator current (A) 100 100 200 200 Number of batteries 2 3 2 3 Connection Weight kg (lbs) Maße h x w x d in mm (h x w x d in Zoll) M8 Studs Weight kg (lbs) 65 x 120 x 200 (2.6 x 4.7 x 7.9) CYRIX microprocessor controlled battery combiner No voltage loss The Cyrix battery combiner is a microprocessor controlled heavy duty relay that automatically connects batteries in parallel when one of the has reached a preset voltage (indicating that the battery is being charged), and disconnects when the voltage decreases below float level (indicating that one or more batteries are being discharged). Cyrix battery separators are an excellent replacement for diode isolators. The main feature is that there is virtually no voltage loss so that the output voltage of alternators or battery chargers does not need to be increased. Prioritising the starter battery In a typical setup the alternator is directly connected to the starter battery. The accessory battery, and possibly also a bow thruster and other batteries are each connected to the starter battery by Cyrix battery combiners. When a Cyrix senses that the starter battery has reached its connect voltage it will engage, to allow for parallel charging of the other batteries. Bidirectional voltage sensing The Cyrix senses the voltage of both connected batteries. It will therefore also engage if for example the accessory battery is being charged by a battery charger. Parallel connection in case of emergency The Cyrix can also be engaged with a switch to connect batteries in parallel manually. This is especially useful in case of emergency when the starter battery is discharged of damaged. Cyrix Battery Cyrix-i 12/24-100 combiner Continuous current (A) 100 Connect voltage (V) From 13V to 13,8V and 26 to 27,6V with intelligent trend detection Disconnect voltage (V) Current consumption when <3 ma open Connection for remote on/off Ja Weight kg (lbs) 0,11 (0.24) Dimensions h x w x d in mm (h x w x d in Zoll) From 11V to 12,8V and 22 to 25,7V with intelligent trend detection 46 x 46 x 80 (1.8 x 1.8 x 3.2) Model Cyrix-i 12/24-200 Cyrix-i 24/48-200 Cyrix-i 12/24-400 Cyrix-i 24/48-400 Continuous current 200A 400A Peak current 1000A during 1 Sec. 2000A during 1 Sec. Input voltage 12/24V Model Input voltage 24/48V Model 8-36VDC 16-72VDC 8-36VDC 16-72VDC Connect/disconnect profiles See table See table Over voltage disconnect 16V / 32 / 64V 16V / 32 / 64V Current consumption when open 4 ma 4 ma Emergency start Yes, 30s Yes, 30s Microswitch for remote monitoring Yes Yes Status indication Bicolour-LED Weight kg (lbs) 0,9 (2.0) Dimensions: h x w x d in mm (h x w x d in Zoll) 78 x 102 x 110 (3.1 x 4.0 x 4.4)

Battery monitoring characteristics Battery Monitoring BMV 600 - S BMV 602 - S BMV 602 - HS VE.Net Battery Controller Precision monitoring The essential function of a battery monitor is to calculate ampere-hours consumed and the state of charge of a battery. Ampere-hours consumed is calculated by integrating the current flowing in or out of the battery. In case of a constant current, this integration is equivalent to current multiplied by time. A discharge current of 10A during 2 hours, for example, amounts to 20Ah consumed. All our battery monitors are based on a powerful microprocessor, programmed with the algorithms needed for precision monitoring. Standard information and alarms Battery voltage (V) Battery charge/discharge current (A) Ampere-hours consumed (Ah) State of charge (%) Time to go at the current rate of discharge Visual and audible alarm: over- and under voltage, and/or battery discharged Programmable alarm or generator start relay. BMV 600-S: low cost ultra high resolution monitor Highest resolution: 10mA (0,01A) with 500A shunt. Lowest current consumption: 1mA. Easiest to wire: the BMV 600 comes with stunt, 10 meter RJ 12 UTP cable and 2 meter battery cable with fuse. No other components needed. Easiest to install: separate front bezel for square or round appearance; ring for rear mounting and screws for front mounting. Broadest voltage range: 9-90 VDC without prescaler needed. BMV 602-S: two batteries and communication port In addition to all the features of the BMV600, the BMV602 can measure the voltage of a second battery and has a communication port. (Isolated RS232 interface is needed tot connect to a computer) BMV 602-HS: 35 to 150VDC voltage range No prescaler needed. VE.Net Battery Controller: any number of batteries One VE.Net panel will connect to any number of battery controllers. Comes with 500A/50mV shunt and can be programmed for any other shunt. With use, abuse and data memory. Temperature sensor and connection kit included. Power supply voltage range 9-90 VDC 9-90 VDC 35-150 VDC 9-60 VDC Current draw, back light off 4mA at 12V 4mA at 12V 3mA 3mA at 48VDC 3mA at 24V 3mA at 24V Input voltage range (VDC) 9-90 VDC 9-90 VDC 35-150 VDC 39-60 VDC Battery capacity (Ah) 20-9999 Ah 20-60000Ah Operating temperature range -20-50 C (0-120 F) Measures voltage of second battery No Yes Yes No Communication port No Yes Yes Yes (VE.Net) Potential free contacts 60V/1A (N/O) resolution (with 500 A shunt) Current ± 0.01A ± 0.1A Voltage ± 0.01V Amp hours ± 0.1Ah State of charge (0-100%) ± 0.1% Time to go ± 1 min Temperature (0-50 C or 30-120 F) n.a. ± 1 C (± 1 F) Accuracy of current measurement ± 0.3% Accuracy of voltage measurement ± 0.4% installation and dimensions Installation Flush mount DIN rail Front 63 mm diameter 22 x 75 mm (0.9 x 2.9 inch) Front bezel 69 x 69 mm (2.7 x 2.7 inch) n.a. Body diameter 52 mm (2.0 inch) n.a. Body depth 31 mm (1.2 inch) 105 mm (4.1 inch) accessories Shunt (included) 500 A / 50 mv 500 A / 50 mv Cables (included) 10 meter 6 core UTP with RJ12 connectors Supplied with 1m cables and cable with fuse for + connection Temperature sensor n.a. Supplied with 3m cable Computer interface n.a. Optional Optional n.a.

VE NET characteristics VE NET stands for VICTRON ENERGY NETWORK, a low power network that will monitor all essential equipment and alarms, and keep you informed through automatic e-mails, text messages, and even voice calls. Similarly the wireless connection could be used to access all systems on board remotely. For the ultimate in monitoring and control of your power system, VE.Net represents the state of the art. As a truly integrated solution, VE.Net provides the following components: 1. Blue power panel - multi character display and interface panel 2. Battery Controller - full function battery monitoring module (any number can be connected to the network). 3. Generator control - full monitoring and control of your generator including auto start/stop functionality. 4. VRM module - enables full access to system status and control remotely through the internet. It also gives a historical overview with graphs and bars trough our internet website. VE.Net can also be integrated with any number of other devices including an on board PC, power distribution systems and or senders and alarms. Your imagination is the only limit to what is possible. Victron Global Remote The Global Remote is a modem which sends alarms, warnings and system status reports to cellular phones via text messages (SMS). It can also log data from Victron Battery Monitors, Multi s, Quattro s and Inverters to a website through a GPRS connection. The usage of this website is free of charge. The idea is simple: you can use it to get SMS alarms from a Multi, a Battery System, or both. When monitoring the usage of batteries, it can be extremely helpful to receive under and overvoltage alarms; whenever they occur. For this purpose, the Global Remote is perfect. A prepaid SIM-card (for example) in combination with the Global Remote is adequate for remotely monitoring your system. Taking it one step further, an internet browser and -connection is all you need to view all of the data online. You can simply create an account on the website and add your modem(s). Subsequently you can configure the GPRS connection, which will enable you to monitor the historic data of several basic properties such as system voltages, power levels and status information. All of this data is graphed. These graphs are available in daily, weekly and monthly timeframes. Victron Remote Management is the name of the system which consists of the VGR and the monitoring website. To get a preview: please go to http://www.victronenergy.com, and login at Victron Remote Management via the Login menu on the upper right of the page. 1x Y cable (16-way plug to male DB9 + 12-way socket) victron energy B L U E P O W E R DB9 male victron global remote SIM gender changer null modem VGR900100000 MK2 interface (included with VGR ) MK2.2a victron energy B L U E P O W E R RJ45 UTP BMV-602 battery monitor 12/24Vdc SETUP + - SELECT RJ12 UTP Cable AGM 12-200

others Batteries VRLA AGM: design life 7-10 years VRLA GEL: design life 12 years VRLA GEL 2 volt cells: design life 20 years The AGM range has very low internal resistance making them particularly suitable for high current discharge and charging. The GEL model range offer best deep cycle durability and overall longer life. The use of high purity materials and lead calcium grids ensure that for both AGM and GEL products have particularly low self discharge so that they will not go flat during long periods without charge. Both ranges are supplied with M8 drilled, flat copper terminals ensuring best possible connection contact and eliminating the need for battery terminals. Manufactured under ISO 9002 quality standards, they are compliant with both CE and UL specifications in ABS fireproof containers and come with Victron s 2 year world-wide warranty. FILAX Transfer Switch Filax: the ultra fast transfer switch The Filax has been designed to switch sensitive loads, such as computers or modern entertainment equipment from one AC source to another. The priority source typically is the mains, a generator or shore power. The alternate source typically is an inverter. PowerMan Transfer Switches Ideal to build a no-break power supply with several paralleled Multi s. The PowerMan transfer switch enables seamless power transfer from one or more AC sources to several paralleled Multi s. In-built AC current monitoring ensures that the AC power management functionality of the Multi s remains available. BatteryProtect (Models: BP-40i, BP-60i, BP-200i) The BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. ESP system panel The new ESP panel system provides a contemporary designed range of panels that cover the core engineering systems. The main system panel is the heart of the range. This provides AC and DC monitoring, Multi control and backlight control. Additional panels include AC and DC circuit breaker panels, a general control panel, a VE Net panel.

4 8 0 12 16 20 16 12 20 8 24 4 28 0 30 24 30 28 www.victronenergy.com www.victronenergy.com mains on bulk absorption float mains on bulk absorption float inverter on overload low battery temperature inverter on overload low battery temperature multiplus principle INVERTER/CHARGER SYSTEM WITH INTELLIGENT SHORE AND GENERATOR POWER MANAGEMENT PowerControl: Dealing with limited generator or grid power All models in the MultiPlus range feature powerful battery chargers. When the largest model is working hard it can draw almost 10A from a 230V supply. Using the remote panel it is possible to dial-in the maximum current that is available from mains or generator. The MultiPlus will then automatically regulate the charger taking account of other system AC loads and ensuring the charger only uses what is spare. This way it is possible to avoid tripping the mains power or overloading the generator. Power control Battery charger reduces its output, if required, to avoid overload of supply when system consumption is high. Multi remote panel MultiPlus inverter on overload PHOENIX MULTI CONTROL mains on boost AC distribution low battery equalize temperature on off charger only float shore current limiter Water Heater (10A) 16A phoenix multi plus 12/3000/120 RCD Microwave (6A) Fridge (1A) TV / DVD (1A) Computer (1A) Kettle (13A) Public grid Battery 12V/300Ahr Services Reduced charge to battery 13A Hairdryer (8A) Power Tools (2A) PowerAssist: Boosting the power available from mains or generator, an innovative feature of Multiplus. The feature that most distinguishes the MultiPlus from other inverter / chargers is PowerAssist. This feature takes the principle of PowerControl to a further dimension by allowing a MultiPlus to supplement the power available from mains or generator to assist during periods of high demand. Peak power demand is almost always sustained only for short periods, either a few minutes (in the case of items like cooking appliances) or just a few seconds (in the case of the burst of energy needed to start an air-conditioning or refrigeration compressor). With the capacity of the generator or mains power set on the remote panel, the MultiPlus detects when the load is becoming too much for the supply and will instantly provide the extra power required. When the demand has reduced, the unit returns to charging the battery. This feature is equally effective in large and small systems helping to reduce the required generator capacity or to achieve greater things with limited mains power. There is even a special feature to enable the MultiPlus/Quattro to work perfectly with portable generators. Power assist Inverter boosts incoming power, if required, to avoid overload of supply when system consumption exceeds supply. Multi remote panel MultiPlus PHOENIX MULTI CONTROL inverter on mains on overload boost AC distribution low battery equalize temperature on float charger only off shore current limiter Water Heater (10A) 16A phoenix multi plus 12/3000/120 RCD Microwave (6A) Fridge (1A) TV / DVD (1A) Computer (1A) Public grid Battery 12V/300Ahr Services Battery delivers energy to Power Assist incoming 21A power Kettle (13A) Hairdryer (8A) Power Tools (2A)

PHOENIX MULTI CONTROL inverter on mains on overload boost low battery equalize temperature float on charger only off shore current limiter VE.NET cancel enter SETUP BMV-602 battery monitor SELECT system application Comfort system Comfort plus system Appliance System Appliance System Lighting Quattro 12/3000/120 Communication & navigation Water heater Microwave oven BMV602-S battery monitor 2x12V/200AH and 1X80AH batteries Digital control remote panel 2 ring introduction hob Alternator 12/150 Coffee machine/kettle TV/DVD Laptop Smal chargers (mobile phone, electric shaver) Refrigerator and freezer DC Link Box Isolation transformer Cyrix batttery separator Lighting 2 xquattro 24/5000/120 Communication & navigation VE-NET Battery controller Water heater 4x12V/200AH and 1X80AH batteries Electric gallery with 4 ring induction Blue Power panel hob, microwave/combi oven, refrigerator, freezer, washer/dryer. Coffee machine and kettle Alternator 12/150 TV/DVD DC Link box Multimedia PC Isolation transformers Small chargers (mobile, phone, shaver etc) Modest air-conditioning Comfort system - 7 kva (30a) capacity Quattro VEBus digital panel BMV-602 Battery Monitor + - AC distribution Water Heater (10A) QUATTRO Microwave (6A) 12 120 Fridge (1A) Shore Power (16A) 32A/30mA RCD/RCBO TV / DVD (1A) Only active with shore/genset Induction Hob Coffee Maker (8A) Hairdryer (8A) Power Tools (2A) DC distribution DC Link Box Cabin Light Genset 230V/50Hz 4kVA Accessory 12V/400Ah (2 x 12V 200Ahr) Water Pump Navigation Equip. Bilge Pumps Shower Pump Comfort plus system - 25 kva capacity MARINE 7 2 x Quattro 24/5000/120 Blue Power panel AC distribution Water Heater (10A) QUATTRO 24 5000 120 QUATTRO 24 5000 120 Microwave (6A) Fridge (1A) TV / DVD (1A) Shore Power (32A) Only active with shore/genset 32A/30mA RCD/RCBO Computer (1A) Coffee Maker (8A) Hairdryer (8A) Washer/dryer (13A) Air - Con (Partial) Induction Hob DC distribution Genset 230V/50Hz 15kVA DC Link Box Accessory 24V/1000Ah (12 x 2V 1000Ahr) VE.NET Battery Controller Cabin Light Water Pump Navigation Equip. Bilge Pumps Shower Pump

BLUESOLAR POLYCRYSTALLINE PANELS Low voltage-temperature coefficient enhances high-temperature operation. Exceptional low-light performance and high sensitivity to light across the entire solar spectrum. 25-year limited warranty on power output and performance. 2-year Limited warranty on materials and workmanship. Sealed, waterproof, multi-functional junction box gives high level of safety. High performance bypass diodes minimize the power drop caused by shade. Advanced EVA (Ethylene Vinyl Acetate) encapsulation system with triple-layer back sheet meets the most stringent safety requirements for high-voltage operation. A sturdy, anodized aluminum frame allows modules to be easily roof-mounted with a variety of standard mounting systems. BlueSolar Panel 130W Highest quality, high-transmission tempered glass provides enhanced stiffness and impact resistance. Pre wired quick-connect system with PV-ST01 connectors. Electrical data under STC (1) Type Module Size Glass size Weight Nominal Power Max-Power Voltage Max-Power Current Open-Circuit Voltage Short-circuit Current PMPP VMPP IMPP Voc Isc Module MM MM KG W V A V A BSP30-12 532x418x23 527x413 3 30 18 1.66 21.6 1.83 BSP50-12 810x534x35 804x528 6.5 50 18 2.78 21.6 3.05 BSP80-12 1196x534x35 1189x528 8 80 18 4.44 21.6 4.88 BSP130-12 1456x666x35 1450x660 13 130 18 7.23 21.6 7.94 BSP180-12 1580x808x35 1574x802 15 180 36 4.95 43.2 5.45 BSP280-12 1930x980x50 1924x974 19 280 36 7.78 43.2 8.55 inverter Module BSP30-12 BSP50-12 BSP80-12 BSP130-12 BSP130-12 BSP280-24 Nominal Power (±3% tolerance) 30W 50W 80W 130W 180W 280W Cell type Monocrystalline Polycrystalline Monocrystalline Polycrystalline Monocrystalline Monocrystalline Number of cells in series 36 72 Maximum system voltage (V) 1000V Temperature coefficient of Isc (%) +0.06/ C +0.06/ C +0.06/ C +0.06/ C +0.06/ C +0.06/ C Temperature coefficient of Voc (%) -0.35/ C -0.35/ C -0.35/ C -0.35/ C -0.35/ C -0.35/ C Temperature coefficient of -0.47/ C -0.47/ C -0.47/ C -0.47/ C -0.47/ C -0.47/ C Temperature coefficient of IMPP +0.06/ C +0.06/ C +0.06/ C +0.06/ C +0.06/ C +0.06/ C Temperature coefficient of VMPP -0.34/ C -0.34/ C -0.34/ C -0.34/ C -0.34/ C -0.34/ C Temperature Range -40 C to +80 C -40 C to +80 C Surface Maximum Load Capacity 200kg/m² Allowable Hail Load Steel ball Steel ball (weight 227g, diameter 25mm) fall down from 1m height Junction Box Type PV-RH0301 PV-RH0301 Connector Type PV-ST01/M PV-ST01/F Length of Cables 900mm 900mm Output tolerance +/-3% +/-3% Frame Aluminium Product warranty 2 years Warranty on electrical performance 10 years 90% + 15 years 80% of power output Smallest packaging unit 2 panels Quantity per pallet 88 panels 44 panels 44 panels 40 panels 52 panels 36 panels 1) STC (Standard Test Conditions): 1000W/m2, 25ºC, AM (Air Mass) 1.5 PV-ST01 connectors

VE.NET cancel POWER CHG.MODE Bat. Select LOAD BATTERY PV - + - + - + enter mains charger failure SETUP BMV-602 battery monitor SELECT PHOENIX MULTICOMPACT MARINE 5 PHOENIX MULTI COMPACT WIND EN SOLAR + - Inverter 24/8000 AC distribution WIND CONVERTER AC Solar system Blue Power panel 2 x Quattro 48/10000/140 PV system QUATTRO 48 10000 140 QUATTRO 48 10000 140 Grid inverter AC distribution VE Solar Switch Water Heater (10A) Microwave (6A) Fridge (1A) Public grid TV / DVD (1A) 32A/30mA RCD/RCBO Computer (1A) Coffee Maker (8A) Hairdryer (8A) Genset 230V/50Hz VE.NET Battery Controller DC Link Box Washer/dryer (13A) Air - Con (Partial) Induction Hob

WIND EN SOLAR SOLUTIONS When the public grid is available, the Victron SolarSwitch will connect the solar inverter directly to the grid. If the grid fails, the power from the solar inverter will be redirected to the output of the MultiPlus. The MultiPlus replaces the grid and will balance the power mismatch between the load and the solar inverter. A power shortage will be supplemented by the MultiPlus, discharging the battery, and excess power will be used to recharge the battery. Once the batteries are fully charged, the excess power can be redirected to a water heater (relay not shown), or a dump load (not shown), or the grid inverter can be stopped by slightly changing the output frequency of the MultiPlus (this is a standard feature of the MultiPlus). In order to prevent the batteries from discharging completely in case of insufficient solar power, some or all loads can be can be shut down with programmable relays available on the SolarSwitch (not shown). Specifications of the SolarSwitch SolarSwitch AC inputs (Mains, MultiPlus/Quattro and Solar) Input voltage range: 187-265 VAC Input frequency: 45 65 Hz Maximum switch through current (A) Maximum power consumption (W) 25A < 4W GENERAL Auxiliary programmable Relay (3X) (1) Status LED Max load: 8A 250VAC 1 Blue / 1 Yellow / 1 Red Common Characteristics Operating temp.: -20 to +50 C Humidity (non condensing) : max 95% ENCLOSURE Common Characteristics Material & Colour: Housing polyamide 6.6 / green Cover unbreakable polycarbonate / Transparent Protection: IP 20 230 V AC-connection Screw terminals 5.2mm² (10 AWG) Auxiliary relay connection Screw terminals 2.5mm² (19 AWG) Weight (grams) 750 Dimensions (hxwxd in mm) 88 x 215 x 110 STANDARDS Safety EN 60335-1, EN 60335-2-29 Emission / Immunity EN55014-1, EN 55014-2, EN 61000-3-3 1) Three programmable relays Can be programmed with VEConfigure Application examples: Alarm, generator start or load shedding function AC rating: 230V/4A DC rating: 4A up to 35VDC, 1A up to 60VDC No-break back-up for grid connected solar system Grid inverter Solar panel 1.Alarm 2.Genset start 3.Load shedding 1. 2. 3. solar programmable relays mains multi SolarSwitch VE.BUS Protected loads Public grid Unprotected loads water heater

BlueSolar charge controllers BlueSolar 12/24-10 10A at 12V or 24V BlueSolar 12/24-10 BlueSolar DUO 12/24-20 - Low cost PWM controller. - Internal temperature sensor. - Three stage battery charging (bulk, absorption, float). - Protected against over current. - Protected against short circuit. - Protected against reverse polarity connection of the solar panels and/or battery. - With low voltage load disconnect output. BlueSolar Power DUO control 12/24-20 20A at 12V or 24V - PWM controller. Battery charger reduces its output, if required, to avoid overload of supply when system consumption is high. - Charges two separate batteries. For example the starter battery and the service battery of a boat or mobile home. - Programmable charge current ratio (standard setting: equal current to both batteries). - Charge voltage settings for three battery types (Gel, AGM and Flooded). - Internal temperature sensor and optional remote temperature sensor. - Protected against over current. - Protected against short circuit. - Protected against reverse polarity connection of the solar panels and/or battery. BlueSolar MPPT 12/24-40 40A at 12V or 24V - Maximum Power Point Tracking (MPPT) controller. Increases charge current by up to 30% compared to a PWM controller. - Charge voltage settings for eight battery types, plus two equalize settings. - Remote temperature sensor. - Protected against over current. - Protected against short circuit. - Protected against reverse polarity connection of the solar panels and/or battery. - With low voltage load disconnect output. BlueSolar MPPT 12/24-40 Blue Solar Charge controllers