Linear fittings Fluorescent fitting EVN - Zones 2 & 22

Similar documents
Linear fittings EVN Fluorescent fitting - zones 2 & 22

Linear fittings EVT Weatherproof fluorescent fitting - Industrial applications

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Linear fittings EVT Weatherproof fluorescent fitting - Industrial applications

Linear fittings EVD Fluorescent fitting - zones 21 & 22

Floodlight fittings HPS, MH or Halogen Floodlight fitting XSF, XQF, XEF - Zones 1, 2

Linear fittings EVNL LED fitting - zones 2, & 22

Linear fittings EVDL LED fitting - zones 21, & 22

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Emergency Luminaire with LED Series EXLUX 6409/1

Easy and safe installation

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

LED Linear Luminaire Series EXLUX 6402

EXEL-L. Detail of the internal side. Transparent polycarbonate

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Linear Luminaire with LED Series EXLUX 6402/2

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

PROTECTA III. Construction Tough glass reinforced polyester body

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

7 Lighting Technology

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

FL Series Light Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2 and 22

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

7 Lighting Technology

Linear Luminaire with LED Series EXLUX 6002

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Linear luminaire with LED Series EXLUX 6002

Floodlight LED Series 6525

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Sheet Steel Emergency Light Fitting Series 6018

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Floodlight LED Series 6525

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Floodlight LED Series 6125

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Compact Sheet-Steel Light Fittings Series 6114/1

7 Lighting Technology

Start Waterproof LED G3 fixed output START WATERPROOF LED G3 1500MM T 4K

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

Compact Sheet-Steel Light Fittings Series 6114

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Sheet-Steel Light Fittings Series 6014 / 6414

Industrial luminaires

TUNNEL54. Safety and fire resistance VENTILATION LIGHTING

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

7 Lighting Technology

EX-REPAIR AND MAINTENANCE RECEPTACLES

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Waterproof TCW060 just light

Linear fluorescent luminaire LED V-CG-S

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

ATM Lighting sp. z o.o

Zone 1 Linear Range - Installation Guide

Industrial luminaires

Protecta Ex na Fluorescent Luminaire

FHL. Ex d. Body in aluminium

ATM Lighting sp. z o.o

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

Protected

7 Lighting Technology

HAZ AREA LIGHTING. Product Brochure. Design to Manufacture FOR HAZARDOUS AREAS. Engineering Solutions. An A-Belco Group Company

CATALOGUE.

IP65 FLUO 2X18W 2X36W

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

EX-RECESSED CEILING LIGHT FITTINGS

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Protecta III GRP ATEX

Floodlight Series 6121

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

Transcription:

Fluorescent fitting Features Double central locking for ingress protection All components mounted on hinged and removable gear tray which gives easy access for maintenance Including accessories (cable gland, plugs & fixing brackets) Option: Automatic switch off on opening for safe maintenance Specifications Main body constructed of glass reinforced polyester for high impact strength UV protected polycarbonate diffuser to resist harsh environments Rated voltage - 26Vac/Vdc 5-6Hz Wiring configuration: 5 wires xentries M2 2x Emergency versions (Type: EM version h battery duration or EMA with h with automatic test and blackstart capabilities) Certifications Standards Approved to: EN679-, 679-5, 679- EC Type examination Directive 94/9/EC certificate to: Ex II G Ex nr IIC T4 Gc for -4 C to + 6 C Ex nr IIC T5 Gc for -4 C to + 5 C Ex II D Ex tc IIIC T5 C Dc IP66 for -4 C to + 6 C Ex tc IIIC T C Dc IP66 for -4 C to + 5 C Glow wire test: 96ºC EN6598-2-22 Ambient -2 C to +55ºC EVN, temperature range: - C to +5ºC EVN EM & EVN EMA IP test: IP66 IEC 6529 (2) Impact protection index: IK9 according to IEC 62262 ABB DTS - Light fittings, boxes & custom built control panels for hazardous areas LIT-4 UK /5 /5

Fluorescent fitting 2 x M8 hole 2mm depth B C 7 mm EVN Dimensional drawing A 7 mm Technical specifications Light Current External dimensions mm Type Wiring Configuration Rating W A 2V A B C Weight kg 5 wires: Equipped with cable gland & 2 plugs EVN2-5 wires x 8.9 785 42 4 4.4 EVN4-5 wires x 6.7 7 9 7 7.6 EVN65-5 wires x 58.26 67 9 7 9.2 EVN22-5 wires 2 x 8.7 785 42 4 4.4 EVN24-5 wires 2 x 6. 7 9 7 7.6 EVN265-5 wires 2 x 58.5 67 9 7 9.2 EVN2-D 5 wires & continuity plate x 8.9 785 42 4 4.4 EVN4-D 5 wires & continuity plate x 6.7 7 9 7 7.6 EVN65-D 5 wires & continuity plate x 58.26 67 9 7 9.2 EVN22-D 5 wires & continuity plate 2 x 8.7 785 42 4 4.4 EVN24-D 5 wires & continuity plate 2 x 6. 7 9 7 7.6 EVN265-D 5 wires & continuity plate 2 x 58.5 67 9 7 9.2 5 wires through: Equipped with 2 cable glands & plug EVN2-B 5 wires through x 8.9 785 42 4 4.4 EVN4-B 5 wires through x 6.7 7 9 7 7.6 EVN65-B 5 wires through x 58.26 67 9 7 9.2 EVN22-B 5 wires through 2 x 8.7 785 42 4 4.4 EVN24-B 5 wires through 2 x 6. 7 9 7 7.6 EVN265-B 5 wires through 2 x 58.5 67 9 7 9.2 EVN2-E 5 wires through & 2 continuity plates x 8.9 785 42 4 4.4 EVN4-E 5 wires through & 2 continuity plates x 6.7 7 9 7 7.6 EVN65-E 5 wires through & 2 continuity plates x 58.26 67 9 7 9.2 EVN22-E 5 wires through & 2 continuity plates 2 x 8.7 785 42 4 4.4 EVN24-E 5 wires through & 2 continuity plates 2 x 6. 7 9 7 7.6 EVN265-E 5 wires through & 2 continuity plates 2 x 58.5 67 9 7 9.2 Technical information Lamps Fluorescent Lamp (order separately) T8 bi-pin tube, lampholder G, diameter 26mm - white industry 4 k. Photometric curve See page 6/ Rated voltages Electronic ballast: - 26Vac/Vdc 5-6Hz. Power factor.98. Terminal block (screws) 6mm²(rigid wire), 4mm² (flexible wire) Terminals supplied L, L2, L, N, PE (looping possible with one additional cable gland) Cable entries Three entries M2 For non- armoured cable: included two M2 nylon plugs (EX-M2) and one M2 nylon cable gland, diameter 6-2mm (EXCGM2S) For armoured cable: included continuity plate - two M2 nylon plugs (EX-M2) and one M2 nickel plated brass cable gland, diameter 6-2/ 8.5-6mm (EXN4MMC) Housing Fiberglass reinforced polyester housing for high impact strength, UV protected polycarbonate diffuser to resist harsh environments, Painted steel gear tray & Stainless steel 6L insert Fixing (included) V5-2x Two zinc-plated steel brackets for ceiling mounting /6 ABB DTS - Light fittings, boxes & custom built control panels for hazardous areas LIT-4 UK /5

Emergency fluorescent fitting - h EVN EM - Zones 2 & 22 Technical specifications Light Current External dimensions mm Type Wiring Configuration Rating W Battery h A 2V A B C Weight kg wires: Equipped with cable gland & 2 plugs EVN2EM- wires x 8 h.9 785 42 4 5.8 EVN4EM- wires x 6 h.7 7 9 7 9. EVN65EM- wires x 58 h.26 67 9 7.6 EVN22EM- wires 2 x 8 h.7 785 42 4 5.8 EVN24EM- wires 2 x 6 h. 7 9 7 9. EVN265EM- wires 2 x 58 h.5 67 9 7.6 EVN2EM-D wires & continuity plate x 8 h.9 785 42 4 5.8 EVN4EM-D wires & continuity plate x 6 h.7 7 9 7 9. EVN65EM-D wires & continuity plate x 58 h.26 67 9 7.6 EVN22EM-D wires & continuity plate 2 x 8 h.7 785 42 4 5.8 EVN24EM-D wires & continuity plate 2 x 6 h. 7 9 7 9. EVN265EM-D wires & continuity plate 2 x 58 h.5 67 9 7.6 * For dimensional drawing please refer to page /6 Electrical Features Lamps Fluorescent Lamp (order separately) T8 bi-pin tube, lampholder G, diameter 26mm - white industry 4 K Rated voltages Electronic ballast: 22-24 Vac/Vdc 5/6Hz Power factor.98. Battery Battery NiCd 7,2V Lumen output in emergency mode ( lamp lit) 2 hours: 4% for EVN2, EVN22,% for EVN4, EVN24, % for EVN65, EVN265 hours: 24% for EVN2, EVN22, 8% for EVN4, EVN24, 8% for EVN65, EVN265 Monitored by one LED Bs Bs Terminal block Terminal block (screws plug in terminal block) 4mm²(rigid wire), 2,5mm² (flexible wire) Terminals supplied L, L2, L, LS, N, PE (looping possible with one additional cable gland) Cable entries Three entries M2 For non- armoured cable: included two M2 nylon plugs (EX-M2) and one M2 nylon cable gland, diameter 6-2mm (EXCGM2S) For armoured cable: included continuity plate - two M2 nylon plugs (EX-M2) and one M2 nickel plated brass cable gland, diameter 6-2/ 8,5-6mm (EXN4MMC) Housing Fiberglass reinforced polyester housing for high impact strength, UV protected polycarbonate diffuser to resist harsh environments Stainless steel 6L insert Painted steel geartray Fixing V5-2x Two zinc-plated steel brackets for ceiling mounting Emergency function diagrams Wiring provided by DTS - Maintained Mode Switch between LS/L - Non Maintained Mode * s Ls L L E Bs Bs N N Ls Ls L L L2 L E ON Lit Charged OFF Only emergency tube lit Discharged ON OFF Charged OFF Only emergency tube lit Discharged * This table corresponds to the position open. If the switch is on position close, refer to the table on the left ABB DTS - Light fittings, boxes & custom built control panels for hazardous areas LIT-4 UK /5 /7

Emergency Fluorescent fitting with automatic test & blackstart capabilities - h. EVN EMA - Zones 2 & 22 Technical specifications Light Nominal External dimensions mm Type Wiring Configuration Rating W Battery h Current A A B C Weight kg 5 wires: Equipped with cable gland & 2 plugs EVN2EMA- 5 wires x 8 h.9 785 42 4 5.8 EVN4EMA- 5 wires x 6 h.7 7 9 7 9. EVN22EMA- 5 wires 2 x 8 h.7 785 42 4 5.8 EVN24EMA- 5 wires 2 x 6 h. 7 9 7 9. EVN2EMA-D 5 wires & continuity plate x 8 h.9 785 42 4 5.8 EVN4EMA-D 5 wires & continuity plate x 6 h.7 7 9 7 9. EVN22EMA-D 5 wires & continuity plate 2 x 8 h.7 785 42 4 5.8 EVN24EMA-D 5 wires & continuity plate 2 x 6 h. 7 9 7 9. * For dimensional drawing please refer to page /6 Electrical Features Lamp Fluorescent Lamp (order separately) T8 bi-pin tube, lampholder G, diameter 26mm - white industry 4 K Rated voltages Electronic ballast: 22-24Vac/Vdc 5/6Hz Power factor.98. Battery Battery NiCd 6V 4Ah for EVN2, EVN22 Battery NiCd 6V 7Ah for EVN4, EVN24 EVS EM A terminals wiring diagram Lumen output in emergency mode ( lamp lit) hours: 4% for EVN2, EVN22 hours: % for EVN4, EVN24 Closed loop option Closed loop option Monitored by two LED EVS EM A terminals wiring diagram Terminal block (spring) Bs Bs Bs Bs Jumped bar x2 terminal blocks 4mm²(rigid wire), 2,5mm² (flexible wire) N N Ls Terminals supplied L, L2, L, LS, N, E, BS (looping possible with one additional cable gland) Cable entries Three entries M2 For non- armoured cable: included two M2 nylon plugs (EX-M2) and one M2 nylon cable gland, diameter 6-2mm (EXCGM2S) For armoured cable: included continuity plate - two M2 nylon plugs (EX-M2) and one M2 nickel plated brass cable gland, diameter 6-2/ 8,5-6mm (EXN4MMC) Housing Fiberglass reinforced polyester housing for LNLNL2Ls Ls L L L2 high impact strength, UV protected polycarbonate diffuser to resist harsh environments, 2 x M8 Stainless steel 6L insert Painted steel geartray E E Ls L E L E Fixing (included) V5-2x Two zinc-plated steel brackets for ceiling mounting VS EM A Emergency terminals wiring function diagramdiagrams Wiring provided by DTS - Maintained Mode losed loop option E Bs Bs E Bs Bs N N Ls Ls L L L2 L E Switch between LS/L - Non Maintained Mode Switched option Switched option E Bs Bs E Bs Bs N N Ls Ls LNLNL2LsLLsE L L L2 L E Preventive maintenance mode Battery charge - daily Emergency lamp during min - weekly Battery charge capacity during hr - quaterly Clear system test display Switched option Switched option Battery charge monitored by 2 LED witched option ON Lit Charged OFF Only emergency Discharged tube lit ON OFF Charged OFF Only emergency Discharged tube lit Healthy (test OK) Emergency or Indicator Lamp Fault (must be replaced) Test in Progress (waiting end of test) Fault (replace battery) E Bs Bs E Bs Bs N N Ls Ls L NL NL2LsLLsE L L L2 L E Emergency function diagram - Blackstart mode Switched option The EMA product contains 2 blackstart terminals. The blackstart mode consists in disconnecting the battery and so switching off the fitting. This mode is mainly used during maintenance. As soon as the maintenance is done, the main power ON and the blackstart terminals connected, the emergency fitting is ready to be used as the battery is not discharged. Switch between BS terminals E Bs Bs This table corresponds to the position open. If the switch is on position close, please refer to the above tables. Mains supply Tube Battery ON Lit Disconnected - not charged OFF OFF Disconnected - not charged /8 ABB DTS - Light fittings, boxes & custom built control panels for hazardous areas LIT-4 UK /5

Accessories Lamps Bi-pin T8 fluorescent lamps Specifications: G - ø 26mm Colour temperature: White industry 4 K CRI: > 8 lm/w: 65 to 9 Average operating life: 2, hours Type Power W Lumen output lm Lampholder TL8W 8 25 G TL6W 6 5 G TL58W 58 52 G Fixing Accessories 2 25 ø9 6 2 25 M Brackets V5 2 x pair of zinc plated steel for ceiling mounting (Included with product) V6 2 x stainless steel 6L brackets for ceiling mounting Hook Type V24 Specifications 2x Zinc plated steel ceiling suspension hook 6, 2 Ø 8.5 2 2xø9 7 2 ø9 6 maxi Mounting bracket clip V4 2x Rapid ceiling mounting with stainless steel clip Hinged bracket V2 2x Steel hinged brackets plastic coated 25 M8 α ø9 ~7 4 Fixing bracket and flange V8 2x zinc plated steel pole mounted brackets for ø ¼ & ½ V9 2x zinc plated steel pole mounted brackets for ø2 V2 2x Stainless steel 6L pole mounted brackets for ø ¼ & ½ V22 2x Stainless steel 6L pole mounted brackets ø2 ABB DTS - Light fittings, boxes & custom built control panels for hazardous areas LIT-4 UK /5 /9

4 5 6 7 8 9 2 4 5 6 7 8 9 2 2 22 2 24 4 5 6 7 8 9 2 4 5 6 7 8 9 2 SAUF INDICATION CONTRAIRE: FINITION: LES COTES SONT EN MILLIMETRES ETAT DE SURFACE: TOLERANCES: LINEAIRES: ANGULAIRES: NOM AUTEUR VERIF. APPR. FAB. QUAL. SIGNATURE DATE MATERIAU: MASSE: CASSER LES ANGLES VIFS TITRE: No. DE PLAN ECHELLE::5 NE PAS CHANGER L'ECHELLE REVISION FEUILLE SUR A A B C D E F G H J K L M N P Q Linear fittings Spare parts V V4 V8N Spare parts Type Specifications EVD 4-24 (toutes config.) V2W 2W diffuser with gasket for EV. range V4W 4W diffuser with gasket for EV. range V65W 65W diffuser with gasket for EV. range V4X2WE Gear tray X8W with electronic ballast -26V 5-6Hz for EVN2 V4X4WE Gear tray X6W with electronic ballast -26V 5-6Hz for EVN4 V4X65WE Gear tray X58W with electronic ballast -26V 5-6Hz for EVN65 V42X2WE Gear tray 2X8W with electronic ballast -26V 5-6Hz for EVN22 V42X4WE Gear tray 2x6W with electronic ballast 22-24V 5-6Hz for EVN24 V42X65WE Gear tray 2x58W with electronic ballast 22-24V 5-6Hz for EVN265 V4X2WEM Emergency gear tray x8w with electronic ballast 22-24V 5-6Hz for EVN2EM V4X4WEM Emergency gear tray x6w with electronic ballast 22-24V 5-6Hz for EVN4EM V4X65WEM Emergency gear tray x58w with electronic ballast 22-24V 5-6Hz for EVN65EM V42X2WEM Emergency gear tray 2x8W with electronic ballast 22-24V 5-6Hz for EVN22EM V42X4WEM Emergency gear tray 2x6W with electronic ballast 22-24V 5-6Hz for EVN24EM V42X65WEM Emergency gear tray 2x58W with electronic ballast 22-24V 5-6Hz for EVN265EM V4X2WEMA Emergency gear tray + auto test X8W with electronic ballast 22-24V 5-6Hz for EVN2EMA V4X4WEMA Emergency gear tray + auto test X6W with electronic ballast 22-24V 5-6Hz for EVN4EMA V42X2WEMA Emergency gear tray + auto test 2X8W with electronic ballast 22-24V 5-6Hz for EVN22EMA V42X4WEMA Emergency gear tray + auto test 2X6W with electronic ballast 22-24V 5-6Hz for EVN24EMA V8N Bi-pin G lampholder V252x4W Brass continuity plate for EV. 2, EV. 22, EV. 4, EV. 24 V2565W Brass continuity plate for EV. 65, EV. 265 EXCGM2S- Kit M2 Exe IIC nylon cable gland for non armoured cable diameter 6-2, and locknut EXN4MMC- Kit M2 Ex-d IIC Ex-e II Ex-td double compression nickel plated cable gland for armoured cable diameter inner 6-2 outer 8,5-6, locknut, sealing gasket /2 ABB DTS - Light fittings, boxes & custom built control panels for hazardous areas LIT-4 UK /5