PoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t

Similar documents
GE CONSUMER & INDUSTRIAL

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Vacuum Circuit Breaker Type VAD-3

RENEWAL PARTS ORDER GUIDE. FCV-500 AND FCV-750 VACUUM CIRCUIT BREAKERS WITH STORED ENERGY OPERATOR NO V

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

A Summary of Major Improvements to the ABB Recloser and Type R Breaker

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

Horizontal Circuit Switchers

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers

www. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS

S&C Type FVR Substation Circuit Breaker

Horizontal Circuit Switchers

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts

DS/DSII Low Voltage Switchgear. Renewal Parts. Cutler-Hammer. Renewal Parts. Effective: October Page 1

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com

GENERAL fj ELECTRIC INSTRUCTIONS AND RECOMMENDED PARTS FOR MAINTENANCE POWERNAC* VACUUM CIRCUIT BREAKER WITH ML-17 MECHANISM.

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF

RENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Submersible Vacuum Fault Interrupters

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

www. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Type SDV7 distribution circuit breaker family

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK

Air-insulated switchgear UniGear type ZS1

MASTERCLAD. Metalclad Indoor Switchgear 27 kv with Type VR Vacuum Circuit Breakers Class Instruction Bulletin. Retain for future use.

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

ABB ADVAC TM. INSTALLATION/MAINTENANCE INSTRUCTIONS Medium Voltage Vacuum Power Circuit Breakers and Auxiliary Devices

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

SDV7. Outdoor distribution circuit breaker family 15.5 kv to 38.0 kv. usa.siemens.com/sdv7

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

ADVAC TM Model 03 Medium Voltage Vacuum Power Circuit Breakers and Auxiliary

T- VACR Fixed (up to 40kA) T-VAC Draw out (up to 40kA)

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

Type SDV7 distribution circuit breaker family Answers for energy.

Section 18. Medium Voltage Equipment. BuyLog Catalog 18-1

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

PowlVac Type PV STD/CDR Vacuum Circuit Breaker

Powered by Safety 01.4IB.77000B PowlVac-ND Vacuum Circuit Breaker

Description Notes. 1. Parts are identified by Breaker Type in the top row and Part Description in the left column.

AM4.16/7.2/13.8-VR + VR-Series + Replacement Circuit Breaker

SWITCHGEAR DIVISION PRODUCT PROFILES

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

DDBB362 : DRAWER [1/10]

MINIATURE CIRCUIT BREAKER

Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

Illustrated Parts List

www. ElectricalPartManuals. com Type AM ,-6 Magne-Biast Circuit Breakers RENEWAL PARTS GENERAL. ELECTRIC GEF-4438A Supersedes GEF-4438

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

R-MAG Medium Voltage Outdoor Dead Tank Vacuum Magnetic Circuit Breaker

Installation Sheet January, 2016 Supersedes February, 2013

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

FEEDMAX W/ SHUTTLE IJ SERIES. Parts Manual

SECTION 3. PARTS INFORMATION

PATENT PENDING. Phone: (877) Operation and Service Manual

CD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK

ON LOAD GEARS OPERATIONAL AND MAINTENANCE MANUAL VACUUM CIRCUIT BREAKER TYPE VS36

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

MODEL EVA PARTS MANUAL Rev.1.03

Illustrated Parts List

www. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Convertamatic 265LX Hydro-Retriever 265HD

Encore S28/L28/S33/L33/S38/L38. Section II. Parts and Service Manual (79049B)

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism

SURE JET ENVELOPE FINISHING SYSTEM MODEL EFS

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS CR7006-C100, -C101 AND -C102 MAGNETIC STARTERS

CATALOG OF REPLACEMENT PARTS

CR193 B,C,D and E Vacuum Limitamp * Contactors

SERVICE PARTS MANUAL

Dynamic Braking Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 1.5 HP to VAC, 3 HP to VAC without NEMA1 Enclosures

Publication No.: PSG

CARGO AND COMBINED CARGO/PASSENGERS (COMBI) CONFIGURATIONS

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

CR193 Vacuum Limitamp* Contactors

Evolution * Series E9000 Motor Control Center

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Vacuum Switchgear Type VMX Spares Manual

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

Power Break Circuit Breakers

MODEL EVA PARTS MANUAL Rev.1.05

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

Transcription:

) rvac Vacuu m Circuit. Breaker PoweMr' With 8 Mechanism L- '.. /,, ( (' p c :t )

FRONT VIEW,. 0 3 Fig. Front View of Breaker with Front Cover 3. COUNTER 0. INTERRUPTER ASSEMBLY Fig. 2 Front View of Breaker without Cover RENEWAL MECHANISM ASSEMBLIES CLOSE& CONTINUOUS LATCH QUANTITY BREAKER CURRENT CURRENT CATALOG MODEL PER DESCRIPTION TYPE AMPERES KA NUMBER DESIGNATOR BREAKER Complete VB -4. 6-250 200/2000 58, 78 044020G00-0 (Not Available) ML-8 &350 044020G002 - (Not Available) Mechanism 044020G003 - (Not Available) VB-7.2-500 200/2000 66, 78 (Two Trip Coils) VB -3.8-500 *Interrupter 750 & 000 200/2000 36, 58, 78 044020G004-2 (Not Available) Ass'y not Mechanism 044020G005-2 (Not Available) included cat numbers (Two Trip Coils) *Must spec. are applicable 044020G006-2 (Not Available) Trip, Close to all (Spec. Aux. Sw.) & Motor bur types 044020G007-2 (Not Available) Voltage 044020G008-2 (Not Available) *Standard Note: 044020 G007 replaces G00, (Two Trip Coils) Duty G002, G004. 044020G009-2 (Not Available) 044020 GOOS replaces G003, GOOS. (Spec. Aux. Sw.) 044020 G009 replaces G006. 044020G00-3 044020G00 replaces G007. 044020G0-3 044020 G0 replaces GOOS. (Two Trip Coils) 044020 G02 replaces G009. 044020G02-3 (Spec. Aux. Sw.) 2

RENEWAL MECHANISM ASSEMBLIES CONTINUOUS CLOSE & QUANTITY BREAKER CURRENT LATCH CATALOG MODEL PER DESCRIPTION TYPE AMPERES CURRENT NUMBER DESIGNATOR BREAKER Complete PVDB- S.S-20 600/200 32,40 044DS2G00-0 (Not Available) ML-8 & -2S & 2000 (SN) Mechanism 044DS2G002-0 (Not Available) (3N) interrupter 044DS2G003-0 (Not Available) Ass'y not (2T-Coils & SN) included 044DS2G004 - (Not Available) 0 Must spec. Q44DS2GOOS - (Not Available) Trip, Close Note: 044[ S2G00 replaces (2 T-Coils) - (Not Available) & Motor G00, G002, G004, G006 & GOOS 044DS2G006 - (Not Available) Voltage 044DS2( 0 replaces 044DS2G007 - (Not Available) standard G003, GOOS a. 0009 (Spec. 24V Trip) Duty 044DS20008 - (Not Available) 044DS20009 - (Not Available) (Two Trip Coils) Dash pot VB-4.6-2SO 200/2000 SS, 78 044DS2000-2 Ass'y for &350 Extended 044DS200-2 Capacitor VB-3.8-500 200/2000 66, 78 (Two Trip Coils) Switching Breaker Types to Include Duty VB-3.8-500 200/2000 36,58, 78 Extended Capacitor 750 & 000 Switching Feature AND PVDB-S.S-20 & 2S 600/ 200 & 2000 32,40 0,, 2, for PVDB RECOMMENDED RENEWAL PARTS Primary Disconnect 200-37 0282A272S0002 VB-0,, 2, 3 6 Contact Assembly 200-SS 0282A270 G002 200-78 0282A2700G003 2000-78 0282A2700G004 200/2000-78 0282A2834G002 VB- 0,, 2, 3 3 2 Operating Rod All Ratings - 077C504G00 PVDBO,, 2 3 3 Spring-Charging 48V-DC 077CS050G003 VB-0,, 2, 3 Motor 2SV-DC & 20V-AC 077CSOSOG00 PVDB 0,, 2 250V-DC & 240V-AC 077CS050G002 4 Charging Link A'ssy 02098804 G00 VB-0,, 2, 3 PVDB 0,, 2 s Relay-Anti Pump 48V-DC 0282A2008P00 VB- 0, (Non-Nuclear) 25V-DC 2082A2008P002 &PVDB 0 250V-DC 0282A2008G00 20V-60 Hz 0282A2008P003 240V-60 Hz 0282A2008P004 20V-SOHz 0282A2008P005 240V-50Hz 0282A2008P006 Relay (Anti-Pump) 48V-DC 0282A7350P00 VB2,3 Non-Nuclear 2SV-DC 0282A7350P002 & PVDB, 2 250V-DC 0282A 7350G00 20V-AC 50/00HZ 0282A7350P003 240V-AC 50/00HZ 0282A7350P004 Spec. Form-C Cont. 48V-DC 0282A7350P03 Spec. Form-C Cont. 2SV-DC 0282A7350P04 3

OTHER VIEWS. PRIMARY DISCONNECT 20. TRACK ROLLERS 23. SPRING DISCHARGE INTERLOCK 28. SECONDARY CONTROL CARRIAGE Fig. 3 Rear View 2. OPERATING ROD 2. WIPE SPRING ASS'Y. INTERRUPfER CLAMP 30. EROSION DISK Fig. 4 Operating Rod & Wipe Spring RECOMMENDED RENEWAL PARTS 6 Trip Coil (5 cycle) 48VOC 02098804G00 V8-0,, 2, 3 *Single & Dual 25 VDC 02098804G002 250 voe 02098804G003 Cap Trip (240 VAC) 02098804G004 Trip Coil (3 cycle) 48VOC 02098804G008 V8-0,, 2, 3 *Single & Dual 25 VDC 02098804G007 250 voe 02098804G006 Cap Trip ( 240 VAC) 02098804G009 Trip Coil (5 cycle) 48VOC 02098804G00 PVD8 0,, 2 *Single & Dual 25 voe ( st Coil) 02098804G007 25 VDC (2nd Coil) 02098804G002 250VDC 02098804G003 Cap Trip (240 VAC) 02098804G004 4 Trip Coil (3 cycle) 48VOC 02098804G008 PV08 0,, 2 *Single & Dual 25 voe (st Coil) 02098804G005 25 VDC (2nd Coil) 02098804G007 250VD 02098804G006 Cap Trip (240 VAC) 020988 04G004 st Coil Only Cap Trip (240 VAC) 020988 04G009 PV08 0,, 2 2nd Coil Only

RECOMMENDED RENEWAL PARTS 7 Close Coil 48VDC 02098803G00 V8-0,, 2 25 VDC 02098803G002 & PVD8 0, 250 VDC 02098803G003 20 VAC 02098803G004 V8-0, (Not Available) & PVD8 0 Note: 02098803G006 replaces G004 and G007 replaces G005 240VAC 020988 03G005 (Not Available) 20 VAC 020988 03G006 V8-2 240 VAC 02098803G007 & PVD8 7 Close Coil 48VDC 02098803G00 V8-3 25 VDC 02098803G002 & PVD8 2 250VDC 02098803G003 20 VAC 02098803G004 240VAC 02098803G005 25 VDC 02098803G00 V8-3 250 VDC 02098803G002 & PVD8 2 240VDC 02098803G004 8 Control Sw. Normally Open 0282A7094P00 V8- o, 4 52/SMLS & 52/LCS & 52/CLMS & PVD80 Control Sw. Normally Closed 0282A7094P002 52/CHG. Control Sw. Normally Open 0282A7094P00 V8-2, 3 3 52/SMLS & 52/LCS & PVD8, 2 Control Sw. Normally Closed 0282A7094P002 52/CHG. Control Sw. Normally Open 0282A7354P003 52/CLMS 9 Auxiliary Sw. 4-a's & 4-b's 020988064P00 V80, S8-2 TYPE 5-a's & 5-b's 020988096P00 & PVD8 0 Auxiliary Sw. 4-a's & 4-b's 020984825P00 V82,3 Electro Sw. Type 5-a's & 5-b's 020984826P00 & PVD8, 2 RENEWAL INTERRUPTER ASSEMBLIES CONTINUOUS CLOSE & LATCH QUANTITY REFERENCE BREAKER CURRENT CURRENT CATALOG MODEL PER NUMBER TYPE AMPERES KA NUMBER DESIGNATOR BREAKER 0 4.6-250 200 58 0282A73 OG00 VB-0,, 2, 3 3 200 78 0282A275 G04 2000 58 0282A275 G079 2000 78 0282A275 G080 200/2000* 58 0282A275 G08 200/2000* 78 0282A275 G082 4.6-350 200 78 0282A275 G045 2000 78 0282A275 G046 200/2000* 78 0282A275 G065 7.2-500 200 66 0282A275 G003 200 78 0282A275 G004 2000 66 0282A275 G085 2000 78 0282A275 G086 200/2000* 66 0282A275 G087 200/2000* 78 0282A275G088 3.8-500 200 37 0282A275 GOOS 200 58 0282A275 G006 5

RENEWAL INTERRUPTER ASSEMBLIES CONTINUOUS CLOSE & LATCH REFERENCE BREAKER CURRENT CURRENT NUMBER TYPE AMPERES KA CATALOG NUMBER MODEL DESIGNATOR QUANTITY PER BREAKER 0 3.8-500 2000 37 2000 58 200/2000* 37 200/2000* 58 3.8-750 200 58 200 78 2000 58 2000 78 2002000 58 200/2000* 78 3.8-000 200 78 2000 78 5.5-20 200 32 2000 32 5.5-25 200 40 2000 40 OTHER VIEWS 22 25 6 9 3 9 0282A275G054 VB-0,, 2, 3 0282A275G090 0282A275 G068 0282A275 G09 0282A275 G007 0282A275 GOOS 0282A275 G058 0282A275 G059 0282A275 G070 0282A275 G07 0282A275G060 0282A275 G06 0282A6524G004 PVDB 0,, 2 0282A6524G005 0282A6524G006 0282A6524G007 7 4 29 3 3 3. SPRING CHARGING MOTOR& CHARGING ASS'Y 4. CHARGING LINK ASS'Y 6. TRIPCOIL 7. CLOSE COIL 9. AUXIlJARY SWITCH 4. TRIP LATCH (HIDDEN FROM VIEW) 5. CLOSE LATCH 6. CHARGING RATCHET 7. CLOSING SPRING & GUIDE A'SSY 8. OPENING SPRING 9. CASTER WHEEL &BRACKET 2. POSITTVE INTERLOCK 22. NEGATIVE INTERLOCK 25. CLOSE SHAFT 27. OPENING SPRJNGROD 29. GROUND BUS 3. V AC. RUPT. STOP FOR CENTER PHASE 33. CLOSE LATCH PIN 34. PROP LATCH 35. CLOSE SPRING CRANK 6 IS 5 6 27 FIG.5 Bottom View

ADDITIONAL RENEWAL PARTS VB-0,, 2, 3 Interrupter Clamp 0282A506 G003 & PVDB 0,, 2 3 VB-0,, 2, 3 2 Wipe Spring Assembly 020988072G002 & PVDB o,, 2 3 3 Operation Counter 0282A768P00 VB- 0, l, 2, 3 Spring for Counter 0282A738P00 & PVDB 0,, 2 VB- 0,, 2, 3 4 Trip Latch 0282A747P00 & PVDB 0,, 2 5 Close Latch 0282A7244G00 "# VB-0, "#See Reference #33 (Not Available) & PVDB O Close Latch Pin for replacement 020988075P00 VB- 2 (Not Available) & PVDB Note: 020988075P003 020988075P003 VB-3 replaces G00 & P00 & PVDB 2 VB-0,, 2, 3 6 Charging Ratchet 020988034G00 & PVDB 0,, 2 0282A73 G00 VB-0,, 2, 3 7 Closing Spring & Guide Ass'y 0282A73G002 PVDB 0,, 2 VB- 0,, 2, 3 8 Opening Spring 0282A7043P00 & PVDB 0,, 2 2 9 Caster Wheel & Bracket 0282B8085GOO VB-0,, 2, 3 20 Truck Rollers 0282A2464G00 VB- 0,, 2, 3 4 2 Positive Interlock 020988040GOO VB-0,, 2, 3 22 Negative Interlock 077C5007G002 VB-0,, 2, 3 OTHER VIEWS 26 24 5 8 24. TOGGLE LINKAGE ASS'Y 5. RELAY 26. CLOSE CAM 8. CONTROLSWITCH Fig. 6 Bottom View Fig. 7 Bottom View 7

ADDITIONAL RENEWAL PARTS REFERENCE CATALOG NUMBER DESCRIPTION NUMBER 23 Spring Discharge Interlock 020988032G00 24 Toggle Linkage Ass'y 02098802G00 Note: 02098802G002 (Not Available) Replaces G00 02098802G002 25 Close Shaft 020988009P00 Note: 0209B P00 (Not Available) Replaces 0209B8009P00 020998P00 - See note bottom page 8 26 Close Cam 044D 229P00 27 Opening Spring Rod 0282A728G00 28 Secondary Disconnect ASM 020983579G00 *Male Pins 0282A208P00 29 Ground Bus Bar 0282A247P00 30 Erosion Disk 0282A796G00 Indicator for Erosion Disk 0282A795P00 3 Stop for Center Phase 0282A743G00 Vacuum Interrupter (Not Available) Note: 077C6640G00 replaces 077C6640G00 0282A743G00 33 Close Latch Pin 0209B3894P00 Note: To replace Close Latch #0282A7244G00 Order - 0209B8075P003 and - 0209B3894P00 34 Prop Latch 0282A 765G00 - See note bottom page 8 (Not Available) Note: 0282A7327G00 0282A7327G00 Replaces 0282A765G00 35 Close Spring Crank 020988000P00 - See note bottom page 8 (Not Available) Note: 0209B8000P002 0209B8000P002 Replaces P00 MODEL DESIGNATOR VB-0,, 2, 3 V8-0, & PVD8 O VB- 2, 3 & PVD8, 2 VB- 0, & PVDB 0 VB- 2, 3 & PVDB, 2 V8-0,, 2, 3 & PVDB 0,, 2 V8-0,, 2, 3 & PVD8 0,, 2 V8-0,, 2, 3 VB-0,, 2, 3 V8-0,, 2, 3 &PVD8 0,, 2 V8- O V8-, 2, 3 & PVD8, 2 VB 2, 3 & PVDB, 2 V8- o, & PVD8 O VB- 2, 3 & PVDB, 2 VB-0, & PVDB o VB- 2, 3 &PVDB,2 QUANTITY PER BREAKER 2 24 3 3 NOTE: REFERENCE PART NUMBERS 25, 34 & 35 MUST BE REPLACED AS SET FOR VB- 0, & PVDB 0 MODELS I./ 8

OTHER VIEWS! 20 22 22. NEGATIVE INTERLOCK Fig. 8 Front and Side View 32 32. STATIONARY AUX SW. Fig. 9 PVDB Mechanism Compartment View RECOMMENDED ITEMS FOR PVDB No Ref. Roof Bushing Ass'y 200 077C6626G00 PVDBO,, 2 6 Number 2000 077C6628G00 32 Stationary Aux. Sw. Mounting 044D56G00 PVDBO (Not Available) Aux. Sw. (SB-2 Type) *3-a's & 3-b's 0226A9287G0 O PVDBO As Required "6-a's & 6-b's 0226A9287G0 *0-a's & 0-b's 0226A9287G02 Stationary Aux. Sw. Mounting *Single (3 or 6-a's & 3 or 6-b's) 044D56G002 PVDB, 2 *Tandem (0-a's & 0-b's) 044056G003 Aux. Sw. (Electro Sw. Type) *3-a's & 3-b's 02098562P00 PVDB,2 As Required "6-a's & 6-b's 02098563P00 "0-a's & 0-b's 02098564G00 Note: 044D56G002 or G003 Replaces G00. With this replacement New Electro Sw. Types must also be ordered. No Ref. Number External Trip Ass'y Parts 2082A6557GOO PVDBO, 2 No Ref. Compartment Heater Mounting Number 2 Heaters 0282A659GOO PVDB 0, 2 4 Heaters 0282A659G002 Strip Heater 300W/240V 0282A4386POO PVDB 0, 2 As required No Ref. Number Door Latch Parts 0282A6557G002 PVDB 0, 2 2 No Ref. Number Bushing Grounding Spring 200A 0282A6496GOO PVDBO, 2 6 2000A 0282A6496G002 9

RECOMMENDED ITEMS FOR MAINTENANCE Figure #0 Lifting Bracket 0209B6588GOO VB-0,, 2. 3 No Ref. VB-0,, 2, 3 Number Travel Recorder Parts 0440235G00 &PVDB0,,2 No Ref. VB-0,, 2, 3 Number Manual Charge Handle 2082A7227P00 & PVDB 0,, 2 No Ref. Closing Spring Gag Plate 020988043G00 VB-0,, 2, 3 Number 020988043G002 PVDB 0,, 2 No Ref. Test Coupler 077C3943G00 VB- 0,, 2, 3 Number Outline & Application Instructions 077C3944 No Ref. Mechanism Removal Bracket 020986539G00 PVDBO Number No Ref. Fastener Assortment ("X" washer) 0282A205G00 VB-0,, 2, 3 Number &PVDB0,,2 No Ref. Spring Assortment 0282A6558GOO VB-0,, 2, 3 Number &PVDB0,,2 No Ref. Lubricating Grease 0282A2048P02 VB-0,, 2, 3 Number & PVDBO,, 2 ) No Ref. Pin Retainer Assortment 0282A5293G00 VB-0,, 2, 3 Number (Snap & "C" Rings) & PVDB 0,, 2 '. j 0