Amerec T100 Steamer Control For use with AT and 3T steam Generators

Similar documents
Amerec T100 Steamer Control For use with AT and 3T steam Generators

Owners Manual. 20 psi. Pub. No. 600-D

ibutler/ibutler2 isteam3 Control PUR AromaSteam SteamHead PUR SteaLinx Mobile App PUR AutoFlush PUR100200E 10-15

AMEREC STEAMBATH GENERATORS 230V~N and 400V~N3

IntelliTouch Expansion Center Kit

AMEREC STEAMBATH GENERATORS

Installation and User Guide

IntelliTouch Pool and Spa Control System Load Center and Power Center

PowerView PV380-R2 Mechanical Configuration

IMPORTANT SAFETY INSTRUCTIONS. READ, FOLLOW AND SAVE THESE INSTRUCTIONS

Installation Guide. Product Code: AC3K P: F: Page 1 of 20

Battery Management Innovation. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

B O O S T B L A C K E D I T I O N

Installation and User Guide

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE

Wireless Tire Pressure and Temperature Monitoring System Instruction Manual Model #: TM Cap Sensors

B O O S T User Manual

Baxter 6201 and 6301 Tips to Avoid Nuisance Alarms Call x 335 for troubleshooting assistance.

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

USER GUIDE Digital Thermostat GUIDE D UTILISATION Thermostat digital Bedienungsanleitung Termostato digital 50-72

PLEASE READ THESE INSTRUCTIONS BEFORE USE

Super Brain 989 The Pinnacle of Performance with Power to Spare User s Manual Model Rectifier Corporation

ME AGS Auto Gen Start Network System with Inverter and Remote for Coach Generators Operator s Manual

Information displays GENERAL INFORMATION A : 238.7

By Inova Labs QUICK START GUIDE. For Use With Model: XYC100B-P4L

Technical Support

LDT Digital Temperature Gauge. Installation & Operation Instructions

CAUTION WARNING. Heading Sensor Assembly HEADING SENSOR FUNCTIONS THEORY OF OPERATION MOUNTING CONSIDERATIONS

INDUCTION TABLE OF CONTENTS INDUCTION VAPOR TECHNOLOGY

June 25, 2013 # Model 464 Electronic Pump Control Unit User Guide

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

WARNING! Decals. IMPORTANT INFORMATION Xxxx xxx xxxx xx xxxx x xxxx. Xxxx xxx xxxx xx xxxx x xxxx.

Cordless Active Sport Massager WITH 3 INTERCHANGEABLE MASSAGE NODES

Signet Temperature Transmitter

INSTALLER MANUAL USER MANUAL. Contents

2017 TigerStop, LLC. Installation Guide AUTOMATION. February 2017 Mk1

is10 Spa-Side Remote Installation Guide (For IntelliTouch and CP3800 series systems)

ECON-ZIP-DETF; ZIP PACK

TABLE OF CONTENTS. B-RAD Select USER MANUAL

Decals. IMPORTANT INFORMATION Xxxx xxx xxxx xx xxxx x xxxx. WARNING! Xxxx xxx xxxx xx xxxx x xxxx.

Smart meter Instructions

Operating and Maintenance Instruction Manual. Evolution Air Bath System

rtable Electric Scooter USER MANUAL A new era in urban mobility PLEASE CAREFULLY READ THE USER MANUAL AND WARRANTY BOOK BEFORE USING!

SPACE SAVING FOLDING TREADMILL SF-T7632 USER MANUAL

January 10, 2017 # Rev. B. Model 464 Mk3 Electronic Pump Control Unit User Guide

Volkswagen Information System. Introduction

BBT-205. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

EASY ASSEMBLY FOLDING TREADMILL SF-T7610 USER MANUAL

Operator Manual. Transfer Switch. RSS100 and RSS Cummins Inc. All rights reserved. English

Information displays GENERAL INFORMATION A : 392.4

SF-T7610 TREADMILL USER MANUAL

Tige Troubleshooting (Electronic Throttle Engines)

TC62D Installation Instructions

TE 2-A22. English. Printed: Doc-Nr: PUB / / 000 / 00

Battery Operated Advanced Computerized Irrigation Controller Installation and Operating Instructions

REV F2.0. User's Manual. Hydraulic ABS (HABS) Hydraulic Power Brake (HPB) Page 1 of 28

Card/Stickers/Pocket (Sleeve) 2016 F-150 Pro Trailer Backup Assist QUICK START GUIDE

2012 CIVIC SEDAN EX, EX-L, Si, and GX

WATER CONTROL SYSTEM QUICK START +1 (208)

Wireless Tire Pressure and Temperature Monitoring System Color Display Manual. Wide Screen Color Display Model #: TST-507-D-C

ThermaSol Superduty Installation & Operating Instructions Commercial Steam Room Generators (Three Phase Only)

PRESTIGE 24 S A 1 2 Z Z. Option. F Function Button IGN AM PM INHIBIT. Unlock/Disarm

Sensormedics Vmax with ECG Tango M2 Interface Notes

Signet Pressure Transmitter

Signet Pressure Transmitter

4L PROVIDER MATERIALS

Soothes every aching muscle in its path.

TWO-WAY LCD AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide

Wireless Tire Pressure and Temperature Monitoring System Instruction Manual Model #: TM-507 SCE 507 Commercial Cap Sensors with Monochrome Display

Paraffin Dispenser Catalog # PD-120, PD-220 Operator s Manual Version 1.5b, Jan 2007

M40/50RF System - Installers Guide

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

Owners Manual for TPMS plus GPS

SIGNET Temperature Transmitter

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

B-RAD Select USER MANUAL TABLE OF CONTENTS

DCC-2500 Digital Climate Control for Vintage Air GEN-IV systems

SPARUS PUMP WITH CONSTANT FLOW TECHNOLOGY

Battery Operated Advanced Computerized Irrigation Controller Installation and Operating Instructions

TIMER INTERFACE USER MANUAL

BEGINNER ELECTROSEX KIT

Package leaflet: Information for the user. Medicinal nitrous oxide Praxair Scandinavia100 %, medicinal gas, liquefied. Nitrous oxide (N 2 O)

6" Heavy Duty Bench Buffer

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

Operating Instructions Leland Legacy SKC Inc. 863 Valley View Road Eighty Four, PA 15330

Installation and Operating Instructions. Solar System Controller ISC3030

CA 6550 Owner s Guide

NaviTrackTM Transmitter

UNITED STATES Ford Customer Relationship Center (FORD) (TDD for the hearing impaired: ) owner.ford.

RF-51-eDp. Operation guide. Deluxe 2-way Oem Upgrade & Range extender. July 22, 2014

Owner / Operator s Manual

Product Name. Paraffin Dispenser. Operator s Manual. Histology Innovation for a NEW Generation PD-120; PD-220. A Division of General Data Healthcare

Phoenix Inverter

Owner and Operating Manual for

IMPORTANT SAFETY INSTRUCTIONS. READ, FOLLOW AND SAVE THESE INSTRUCTIONS

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

LT Charging Cart for Laptops

Transcription:

Operating Instructions WARNING The T100 control operates on 12VDC and does not present a shock hazard. Electric Shock Hazard - High voltage exists within the steam equipment. There are no user serviceable parts in this equipment. All installation and service to this equipment should be performed by qualifi ed licensed personnel. Do not exceed 30 minutes in a steam bath. Excessive exposure can be harmful to your health. Excessive exposure can produce a rapid pulse, light-headedness, weakness or fainting. If you become uncomfortable or experience any of the above conditions exit the steam bath immediately. Amerec T100 Steamer Control For use with AT and 3T steam Generators FOR THE SAFETY OF YOU AND YOUR FAMILY PLEASE READ THE WARNINGS TO THE RIGHT AND ALL INSTRUC- TIONS BEFORE USING YOUR STEAMBATH. POST "WARNING" LABEL OUTSIDE STEAM BATH FOR SAFETY WARNINGS. POSTING IS REQUIRED ON OR AD- JACENT TO STEAM ROOM DOOR FOR ALL COMMERCIAL INSTALLATIONS. Steam baths can put stress on the body. Therefore a steam bath should be used only under a doctor's direction if you: Are pregnant Have a heart condition Have high blood pressure Have circulatory problems Are under the infl uence of alcohol Are under the infl uence of drugs Have diabetes Are under the care of a physician Are in generally poor health Children should only use the steam bath under close adult supervision. Scald Hazard: Do Not Touch the steam head or trim during operation as they are HOT. Stay at least 12 inches away from the hot steam escaping from the steam head. Be careful when entering a steam bath. Escaping steam from an overheated steam room may cause injury. REDUCE THE RISK OF OVERHEATING AND SCALDING 1. Exit immediately if uncomfortable, dizzy or sleepy. Staying too long in a heated area is capable of causing overheating. 2. Supervise children at all times. 3. Check with a doctor before use if pregnant, diabetic, in poor health or under medical care. 4. Breathing heated air in conjunction with consumption of alcohol, drugs or medication is capable of causing unconsciousness. Do not contact steam head. Stay at least 12" away from hot steam escaping from the steam outlet. CAUTION! WARNING REDUCE THE RISK OF SLIPPING AND FALL INJURY Use care when entering or exiting the steam room, floor may be slippery. NOTE: For additional safety instructions, see owner's manual. SAVE THIS MANUAL Thank you for purchasing your new Amerec steam generator. If we can be of any assistance do not hesitate to call our Technical Support at 1-800-363-0251.

Operating Instructions Page 2 IMPORTANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. WARNING - To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. 3. WARNING - To reduce the risk of injury: a. The wet surfaces of steam enclosures may be slippery. Use care when entering or leaving. b. The steam head is hot. Do not touch the steam head and avoid the steam near the steam head. c. Prolonged use of the steam system can raise excessively the internal human body temperature and impair the body s ability to regulate its internal temperature (hyperthermia). Limit your use of steam to 10-15 minutes until you are certain of your body s reaction. d. Excessive temperatures have a high potential for causing fetal damage during the early months of pregnancy. Pregnant or possibly pregnant women should consult a physician regarding correct exposure. e. Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a steam bath. f. Persons using medication should consult a physician before using a steam bath since some medication may induce drowsiness while other medications may affect heart rate, blood pressure and circulation. 4. WARNING - Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6 F. The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness and fainting. The effect of hyperthermia include: a. Failure to perceive heat: b. Failure to recognize the need to exit the steam bath: c. Unawareness of impending risk: d. Fetal damage in pregnant women: e. Physical inability to exit the steam bath: and f. Unconsciousness. WARNING - The use of alcohol, drugs or medication can greatly increase the risk of hyperthermia. SAVE THESE INSTRUCTIONS

Operating Instructions Page 3 T100 CONTROL OVERVIEW The T100 control is a low voltage wired control for use with Amerec s AT and 3T series steam generators. The control requires a shielded cable to connect to the steam generator. Failure to use a properly shielded cable may result in poor performance! A temperature sensor (required) mounts inside the steam room and connects to the steam generator. The T100 uses touch screen switches to move through various menu screens to: start and stop the steam bath set or display the bath temperature choose between F and C temperature displays set the bath run time set a delayed start time for the steam bath set and display the time of day choose the displayed language control a low voltage room light Note: The T100 will vibrate gently and a buzzing noise may be heard when a switch is pressed. This helps the user know that the switch was successfully pressed. This may be turned off if desired -- see the menu instructions on page 8. TEMPERATURE SENSOR T100 CONTROL STEAM GENERATOR STEAM ROOM

Operating Instructions Page 4 Key To Symbols: Main Menu 1. On/Off 2. Set Temperature 3. Set Bath Run Time and Delayed Start 4. Go to Menu See Page: 5 5 4 6 7-9 Navigation Keys 9. Lighting - Room Light On/Off 10. OK - Confi rm Selection 11. Navigation Arrows - Move through menu items or change settings. 12. Home - Return to Main Menu Screen 13. Back - Move Back One Menu Item or One Step Status 5. Keypad Locked 6. Delayed Start On 7. Room Light On 8. Steam Bath On See Page: 8 6 5 5

Operating Instructions Page 5 T100 CONTROL: OPERATION To view the T100 display, simply touch the lower half of the glass screen. When you are used to using your control, you ll fi nd that movement near the switches will light the display without touching it in most circumstances. Be careful not to touch the control near the OK switch - this may start or stop a steam bath before you are ready. To navigate through the menus and their options: Use the up and down arrow navigation keys to move through the menu items to highlight the one you want, then press to select it. To back up one step, press the key. To return to the Main Menu from any menu, press the home key. Note: at any time, pressing the switch will turn a low voltage room light on or off. MAIN MENU Select to start or stop the steam bath cycle TEMPERATURE Select to change the steam bath temperature TIME Select to change the bath run time or to set and activate the delayed start time SETTINGS Select to go to the next menu level STATUS DISPLAY Located at the bottom of the menu screen, the Status s shows when certain functions are on or off. When the key is shown, the keyboard is locked When the clock is shown Delayed Start is activated When the light is shown, the room light is switched on When the On/Off symbol is shown, the steam bath is running

Operating Instructions Page 6 TEMPERATURE MENU Temperature Select the Temperature icon to adjust the desired steam bath temperature. The current steam bath temperature set point is displayed. Use and navigation keys to scroll the temperature up or down to the desired setting then press OK. 120 Default is 115 F (46 C) and the temperature is adjustable to 125 F (51 C) TIME MENU Select the Time icon to adjust the desired steam bath run time or to controll a delayed start. Time Max time Start Time Activate 12:00 am Select Max Time to adjust the desired steam bath run time. The current steam bath run time setting is displayed. Use the navigation keys to change each digit to its desired setting, then press OK to go to the next digit. Set max time 01:00 Default is 1 hour and adjustable up to 24 hours. Time Max time Start Time Activate 12:00 am The T100 may be set to automatically start the steam bath at a later time, for example if you should want the steam bath ready to use when you get up in the morning. Select Start Time to adjust the time of day you want the steam bath to start. Use the navigation keys to change each digit to its desired setting, then press OK to go to the next digit. Remember to set am/pm correctly. Start t time 00:00 Once the time is set, the delayed start is automatically activated. Time Max time Start Time Activate 06:30 am When the delayed start option is activated, the clock symbol will appear at the bottom of the menu screens. To turn off the delayed start, go to the Time menu and select Deactivate then press OK. The clock symbol will also disappear from the menus. Choose Activate to turn on the delayed start again with the same start time. Time Max time Start Time Deactivate 06:30 am Note: the selcted Delayed Start time is displayed in the Time menu.

SETTINGS MENU Select the icon to adjust the to your personal preferrences. T100 Steamer Control Operating Instructions Page 7 Select Status to display the current temperature in your steam bath and the time of day. If the steam bath is off, the display will automatically turn off after a delay (set in, below). If the steam bath is on, the Status display will remain lit. 120 06:45 am Select to set the time of day. Use the navigation arrows to change the number up or down then OK to accept. Use the Back arrow to move back to the previous digit. Note: When the clock is set to the 12 hour display mode, the fi rst hours digit cannot be changed to a 1 if the second digit is 3 or higher. Set clock 01:00 am Select to change the language used in the T100 s display. Use the navigation keys to highlight the language preferred then press OK to select. English Svenska Deutsch Francais Select to set how long the T100 s displays will remain lit. To increase the life of the T100 s display, it will automatically turn off after a preset time. To set this time: Press OK to select Sleep (automatically highlighted when enterring the menu) Use the navigation arrows to change the sleep time. The sleep time is set to 15 seconds by default and is adjustable from 3 to 90 seconds. Sleep Sleep 15 s

Operating Instructions Page 8 SETTINGS MENU (continued) Select to prevent others from using the T100. When is on, The display will light but the T100 will not respond to key presses. To set, fi rst select Time, then adjust the desired delay time, then press OK. The delay is 15 seconds by default, adjustable from15 to 60 seconds. Next select OFF and press OK. is now enabled. After the selected delay time has passed, the keyboard will be locked and the key symbol will be displayed. Repeat to turn off again. Time 15 s To access the T100, press the Home and Back keys at the same time and hold for about 3 seconds. These two keys may also be used to manually lock the keypad without turning on. Select to change the effect when a key is pressed. By default, when a key is pressed on the T100, there is a small vibration felt and a buzzing sound. Select, use the navigation keys to select On or Off, then press OK to turn this effect on or off. On Status tus Vib ibration Servi vice Select to go to the menu. The menu allows setting some personal options and is passcode protected to prevent unauthorized use. Select then use the navigation keys to enter the code 124, then press OK to enter the menu. Enter code 0 0 0 SERVICE MENU Set max temperature Select Max temp to adjust the maximum bath Status tus Max temp temperature setting allowed. By default, the bath C or F maximum temperature is 125 F (51 C). The max. 24 or 12 hour temperature may be adjusted down from there to 125 any value. Factory Set Vib ibration Test Servi vice

Operating Instructions Page 9 SERVICE MENU (continued) Status tus Vib ibration Servi vice Max temp C or F 24 or 12 hour Factory Set Test Select C or F to choose the temperature display units you prefer. Use the navigation keys to select Celcius or Fahrenheit then press OK. Select 24 or 12 hour to choose the way you want the time of day clock to display, either from 1 to 12 am and 1 to 12 pm or from 1 to 24 hours. (ex. 10:00pm = 22:00) Select temp. Celsius C Fahrenheit F Select time format 24 hour 12 hour Max temp C or F 24 or 12 hour In areas with hard water, the steam generator may require decalcifi cation periodically. The T100 may be set to remind you when it is time to do this. Run time Factory Set Test Select Decalcification then select Decalcifi cation time to set the the run time before the T100 notifi es you that decalcifi cation is scheduled. The run time may be set from 0 (off) to 100 hours of operation. When the steam generator has been used for the number of hours set in Decalcifi cation, you will be asked if decalifi cation has been done each time a steam bath is turned on until you respond with yes. 40:00 Run time To determine how many hours the steam generator has run since the last decalcifi cation, go to the Decalcifi cation menu and select Run time. The run time will reset when you respond yes to the decalcifi cation reminder. 00:00 Max temp C or F 24 or 12 hour Factory Set Test Two additional items are available in the menu: Factory Set and Test. Factory Set is used as part of the initial T100 set up and is not available for the user. Test is used during troubleshooting and should not be used without factory assistance. Contact Technical Support at 1-800-363-0251 for more information or assistance.

Operating Instructions Page 10 TROUBLESHOOTING There are no user serviceable parts in the T100. If your T100 is not operating properly: Check the cable between the control and the steam generaor. Make sure it is a shielded cable (plugs on both ends are covered with metal shells.) Make sure it is conected fi rmly at both ends. Make sure there are no staples through the cable or other damage. Check for corrosion on the connectors. Check the steam Generator Is a green light blinking on the steamer s circuit board? If not make sure the generator s power is on and refer to the steamer s Installation Instructions for a troubleshooting guide. Contact Technical Support for assistance. Technical Support PO Box 2258 Woodinville, WA 98072 Phone 1-800-363-0251 FAX 425-951-1130 email: support@amerec.com