TWINFLOW STDR Product Brochure

Similar documents
MULTIFLOW SEL Product Brochure

ISEO IMF Product Brochure

QUBE SQU-HT(S) Product Brochure

BIFLOW SB CON Product Brochure

REVOLUTION SLCX Product Brochure

BOX BLB Centrifugal Box Fan

CLASSIC SAX Window / Wall Mounted Axial Fan. Select models available for next day delivery

ZOO FAN SDF Destratification Ceiling Mounted Fan

SKYFLOW SSR Product Brochure

TURBOFLOW TF Contra Rotating Axial Flow Fan

Elta Select Product Guide 2016

Mixed Flow Roof Fans (RMH)

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Sentinel D-Box Twin Fan

Sentinel D-Box Single Fan

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

Mixed Flow Roof Fans (RMH)

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

Square Mixed Flow Fans (MFQ)

Sabre Plate Mounted Sickle Fans (VSP)

NEW Acoustic In-Line Fans (ACQ)

NEW Slimpak EC Box Fan (SLPT EC)

HIT CENTRIFUGAL IN-LINE FANS ACCESSORIES APPLICATION FEATURES & BENEFITS CONSTRUCTION

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Vent-Axia Sabre Sickle Roof Fans (VSR)

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

IN-LINE CENTRIFUGAL DUCT FANS VT Series

AC Commercial Fans Edition. ErP ready

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered

HIT CENTRIFUGAL IN-LINE FANS ACCESSORIES APPLICATION FEATURES & BENEFITS CONSTRUCTION

Plate mounted axial flow fans HXBR / HXTR Series

MegaBox Product-specific information

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

HIGH TEMPERATURE TWIN SQUIF FANS

GigaBox centrifugal fans Product specific information

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

Acoustic Twin Fans (ATQ)

Performance. Sound Levels. Impellers. Motors. Accessories

ACOUSTIC CABINET FANS CVB / CVT Series

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code

SCC. Duct in-line centrifugal fans FEATURES & BENEFITS APPLICATION ON REQUEST ACCESSORIES CONSTRUCTION. Patent GB

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

Multi-Port Centrifugal Fans for Round Duct

LC/SC. Long & Short Cased Axial Fans

TCDH F400-TCDV F400. Smoke extract - Fire protection SMOKE EXTRACT FANS CENTRIFUGAL BACKWARD ROOF FANS F Application. Range.

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

Highline 260i EC Waterside Fan Coil Unit

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

Galaxy TM In-Line Belt Driven Twin Fans (GDB)

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

ACOUSTIC CABINET FANS CVAB / CVAT Series

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

NCF fans 50 Hz. Protection class IP 55

Multifunctional 400ºC/2h and 300ºC/2h roof fans

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

SCC DUCT IN-LINE CENTRIFUGAL FANS FEATURES & BENEFITS APPLICATION ACCESSORIES CONSTRUCTION. Patent GB

WINDER. Impellers with higher efficiency and less sound level

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Short casing. Long casing (L version) Commercial premises

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

Unobox units with backward curved centrifugal impellers

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

VORTICENT C E RANGE Centrifugal fans

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

CK, LPK, LPKB. Duct fans with circular connection.

ROOFMASTER STEF-HT ROOF FAN

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

ROOF FAN ROOFMASTER STEC

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

QC RANGE ACOUSTICALLY LINED SINGLE BOX FANS PUREAIR KENT LTD ERP 2015 COMPLIANT

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

Bifurcated Case Axial Fans (BIFA)

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

supplied in Form (B) configuration. Airflow over Impeller- Motor.

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

60Hz VENTILATION SOLUTIONS

Specifications ROOF MOUNTED SEAT SERIES. ATEX version. 1 - Roof unit kit. 2 - Enclosed pedestal. Roof unit kit includes:

Transcription:

TWINFLOW STDR Brochure Available for next day delivery with ELTA SELECT

Direct Drive Twin Centrifugal Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit eltaselect.com. QUICK FACTS ü 5 standard sizes from 200mm to 500mm. ü Air volume flow rates up to 0.23 m³/s (AC) / 1.65 m³/s (EC). ü Static pressures up to 500 Pa (AC) / 960 Pa (EC). ü Suitable for operating temperatures up to +60 C. ü Extensive range of stock available. ü Available in AC and EC. CASING The unit casing shall be manufactured from 1.2mm thick natural finish Aluzinc. The casing shall be designed so as to minimise vibration and shall incorporate a louvered air discharge guarded against bird ingress. Drain points shall also be provided. Each casing provides an inlet spigot to suit standard circular ducting. EPDM (Ethylene Propylene) rubber U shaped seals (being ozone and UV stable) are used to ensure a good seal back to the duct that is to be attached. Top access panels shall be provided for ease of servicing. IMPELLER High efficiency low tonal noise backward curved centrifugal impeller, dynamically balanced to ISO 14694 Grade G6.3 and directly driven by the motor to provide a smooth airflow through the unit. MOTORS The Twin range of units may have either an EC or AC external rotor motor fitted as standard. The motor contains sealed for life bearings. Thermal Class of motors to THCL 130 or 155 dependent on size. Manufactured by Ziehl-Abegg providing increased reliability. All motors are suitable for use in ambient air conditions up to +60 C. QUALITY MANAGEMENT All units in the Elta range are designed and manufactured to procedures as defined in BS EN ISO 9001:2008. They are also tested in accordance with BS848 Part 2 1985 (sound performance) and ISO 5801:2007 (airside performance). TYPICAL APPLICATIONS Industrial Building Banks Hospitals Offices Hotels and Shopping Malls ACCESSORIES For full accessories & controls information please visit eltaselect.com ACO Panel : 149-ACO Electronic Controller :149-POT Transformer Controller : 149-TC Flexible Connections : 018 FLEX Clamps : 018 CLAMP Silencer : 068 JF Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 2

Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Speed r/min Airflow Airflow m³/s @ Static Pressure Pa. 0 25 50 75 100 150 200 250 300 350 400 500 Overall Efficiency % Motor Electrical Data Peak Amps Input kw dba @ 3m STDR200-1AC 2490 STDR250L-1AC 2506 m³/s 0.125 0.115 0.107 0.099 0.091 0.076 0.061 0.045 0.026 0.004 Inlet 48 20.1 0.28 0.065 W/(L/s) 0.50 0.54 0.59 0.64 0.69 0.82 1.01 1.33 2.15 12.31 Outlet 47 m³/s 0.235 0.225 0.216 0.206 0.197 0.178 0.159 0.137 0.113 0.085 0.056 0.008 Inlet 51 25.2 0.63 0.145 W/(L/s) 0.56 0.59 0.62 0.65 0.69 0.77 0.87 1.01 1.22 1.58 2.27 12.45 Outlet 55 Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: D. Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 3

Performance, SFP & Electrical Data EC SINGLE Phase - 200V to 277V / 50Hz or 60Hz Control Voltage Airflow Airflow m³/s @ Static Pressure Pa. 0 25 50 75 100 150 200 250 300 350 400 500 Overall Efficiency % Motor Electrical Data Peak Amps Input kw dba @ 3m STDR200-1EC STDR250H-1EC STDR250L-1EC STDR315-1EC STDR400-1EC m³/s 0.160 0.152 0.147 0.142 0.137 0.128 0.119 0.110 0.101 0.091 0.079 0.044 Inlet 58 29.4 1.15 0.128 W/(L/s) 0.77 0.81 0.85 0.89 0.92 0.99 1.07 1.16 1.26 1.40 1.59 2.61 Outlet 57 m³/s 0.128 0.122 0.116 0.109 0.103 0.091 0.079 0.068 0.057 0.046 0.034 0.007 Inlet 55 19.6 0.92 0.107 W/(L/s) 0.78 0.81 0.86 0.90 0.96 1.09 1.26 1.48 1.78 2.22 2.96 13.94 Outlet 55 m³/s 0.078 0.066 0.057 0.048 0.040 0.023 0.004 Inlet 45 14.7 0.31 0.038 W/(L/s) 0.40 0.48 0.56 0.67 0.81 1.44 8.59 Outlet 44 m³/s 0.021 Inlet 21 2.2 0.07 0.009 W/(L/s) 0.40 Outlet 22 m³/s 0.310 0.295 0.278 0.262 0.248 0.224 0.203 0.184 0.165 0.146 0.127 0.088 Inlet 54 30.8 2.04 0.242 W/(L/s) 0.59 0.63 0.67 0.71 0.76 0.84 0.93 1.03 1.15 1.31 1.53 2.32 Outlet 55 m³/s 0.224 0.214 0.199 0.183 0.170 0.147 0.123 0.092 0.061 0.041 0.026 Inlet 50 25.1 1.14 0.138 W/(L/s) 0.50 0.52 0.56 0.61 0.66 0.76 0.92 1.26 1.98 3.06 4.94 Outlet 50 m³/s 0.132 0.110 0.090 0.071 0.054 0.024 Inlet 39 17.3 0.37 0.043 W/(L/s) 0.28 0.33 0.41 0.52 0.70 1.64 Outlet 37 m³/s 0.035 Inlet *20 4.1 0.08 0.010 W/(L/s) 0.27 Outlet *20 m³/s 0.280 0.272 0.265 0.258 0.252 0.240 0.228 0.216 0.203 0.189 0.173 0.135 Inlet 57 34.2 1.97 0.244 W/(L/s) 0.76 0.79 0.82 0.85 0.88 0.93 0.99 1.06 1.14 1.24 1.36 1.72 Outlet 60 m³/s 0.229 0.219 0.209 0.198 0.187 0.164 0.142 0.122 0.105 0.088 0.074 0.045 Inlet 54 24.5 1.45 0.180 W/(L/s) 0.64 0.67 0.70 0.74 0.78 0.89 1.03 1.20 1.40 1.67 2.04 3.43 Outlet 55 m³/s 0.129 0.115 0.102 0.088 0.075 0.048 0.026 0.010 Inlet 42 20.3 0.43 0.053 W/(L/s) 0.33 0.38 0.43 0.50 0.59 0.95 1.86 4.96 Outlet 44 m³/s 0.041 0.012 Inlet 29 4.0 0.08 0.011 W/(L/s) 0.24 0.80 Outlet 30 m³/s 0.556 0.542 0.528 0.514 0.500 0.472 0.442 0.412 0.380 0.344 0.303 0.187 Inlet 51 38.0 1.90 0.411 W/(L/s) 0.69 0.71 0.73 0.74 0.76 0.81 0.86 0.92 0.99 1.08 1.20 1.73 Outlet 57 m³/s 0.432 0.418 0.403 0.387 0.370 0.331 0.284 0.223 0.133 Inlet 45 32.5 1.05 0.222 W/(L/s) 0.49 0.51 0.53 0.55 0.58 0.64 0.73 0.88 1.25 Outlet 50 m³/s 0.254 0.216 0.182 0.149 0.105 Inlet 35 23.3 0.33 0.064 W/(L/s) 0.25 0.29 0.33 0.40 0.52 Outlet 38 m³/s 0.064 Inlet *20 2.3 0.10 0.014 W/(L/s) 0.22 Outlet *20 m³/s 0.962 0.945 0.929 0.913 0.898 0.867 0.836 0.805 0.774 0.742 0.709 0.638 Inlet 61 43.6 4.29 0.944 W/(L/s) 0.89 0.91 0.93 0.94 0.96 1.00 1.04 1.08 1.12 1.17 1.23 1.36 Outlet 65 m³/s 0.760 0.744 0.728 0.712 0.695 0.661 0.625 0.586 0.542 0.493 0.432 0.160 Inlet 56 39.9 2.46 0.526 W/(L/s) 0.60 0.62 0.65 0.67 0.69 0.74 0.80 0.85 0.92 1.00 1.11 2.08 Outlet 59 m³/s 0.433 0.409 0.381 0.349 0.311 0.196 Inlet 41 29.7 0.62 0.132 W/(L/s) 0.28 0.30 0.33 0.37 0.42 0.61 Outlet 43 m³/s 0.111 Inlet *20 18.2 0.19 0.005 W/(L/s) 0.04 Outlet 22 Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: C. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. A Variable Speed Drive is intergrated within the fan. *At the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 4

Performance, SFP & Electrical Data EC SINGLE Phase - 200V to 277V / 50Hz or 60Hz Control Voltage Airflow Airflow m³/s @ Static Pressure Pa. 0 25 50 75 100 150 200 250 300 350 400 500 Overall Efficiency % Motor Electrical Data Peak Amps Input kw dba @ 3m STDR500-1EC m³/s 1.302 1.271 1.240 1.208 1.175 1.107 1.035 0.959 0.877 0.788 0.691 0.456 Inlet 52 44.3 3.43 0.776 W/(L/s) 0.56 0.57 0.58 0.60 0.62 0.66 0.71 0.76 0.83 0.91 1.01 1.37 Outlet 59 m³/s 1.020 0.982 0.942 0.902 0.860 0.771 0.672 0.561 0.427 0.240 Inlet 47 40.3 1.89 0.429 W/(L/s) 0.39 0.41 0.43 0.45 0.47 0.52 0.60 0.70 0.85 1.26 Outlet 53 m³/s 0.600 0.518 0.441 0.358 0.256 Inlet 35 31.4 0.58 0.115 W/(L/s) 0.19 0.22 0.25 0.29 0.37 Outlet 39 m³/s 0.133 Inlet *20 13.8 0.18 0.005 W/(L/s) 0.03 Outlet *20 Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: C. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. A Variable Speed Drive is intergrated within the fan. *At the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 5

Performance, SFP & Electrical Data EC THREE Phase - 380V to 480V / 50Hz or 60Hz Control Voltage Airflow Airflow m³/s @ Static Pressure Pa. 0 25 50 75 100 150 200 250 300 350 400 500 Overall Efficiency % Motor Electrical Data Peak Amps Input kw dba @ 3m STDR500-3EC m³/s 1.655 1.620 1.590 1.561 1.534 1.482 1.432 1.381 1.328 1.274 1.217 1.093 Inlet 60 44.9 2.43 1.588 W/(L/s) 0.86 0.89 0.91 0.94 0.96 1.01 1.06 1.10 1.15 1.20 1.26 1.38 Outlet 68 m³/s 1.287 1.251 1.216 1.180 1.144 1.072 0.998 0.922 0.844 0.763 0.676 0.480 Inlet 54 41.6 1.41 0.859 W/(L/s) 0.66 0.68 0.69 0.71 0.72 0.76 0.81 0.86 0.91 0.98 1.07 1.36 Outlet 60 m³/s 0.770 0.698 0.630 0.563 0.497 0.355 0.169 Inlet 41 35.4 0.49 0.209 W/(L/s) 0.28 0.29 0.31 0.34 0.37 0.48 0.83 Outlet 46 m³/s 0.189 Inlet *20 7.0 0.16 0.024 W/(L/s) 0.13 Outlet 22 DCV CONTROLS Demand Control Ventilation (DCV) EC options available, refer to pages 228-229 for DCV information and page 169 for product information; to order add DCV to product code: SSDR200-EC with DCV order SSDRDCV200-EC. Data in accordance with ErP 1253/2014 of the European Parliament. category is NRVU. Measurement category used to determine energy efficiency: C. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. A Variable Speed Drive is intergrated within the fan. *At the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 6

Dimensional Data C 76 E A Ø D B F A B C D E F Weight kg STDR200 550 565 296 200 56 85 30 STDR250L 602 652 387 250 55 85 40 STDR250H 602 652 387 250 55 85 41 STDR315 750 864 478 315 73 85 65 STDR400 846 1019 478 400 48 85 85 STDR500 988 1254 606 500 50 85 118 Dimensions are in mm. Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 7

Accessories ACO Panel Transformer Controller Flexible Connections Clamps Silencer 300mm Silencer 600mm Silencer 900mm Silencer 1200mm Wiring Diagram STDR200-1AC 149-ACO18 149-TC12 018-0200-FLEX 018-200-CLAMP 068-0200-JF1 068-0200-JF2 068-0200-JF3 068-0200-JF4 152-2177 STDR250L-1AC 149-ACO18 149-TC12 018-0250-FLEX 018-250-CLAMP 068-0250-JF1 068-0250-JF2 068-0250-JF3 068-0250-JF4 152-2177 Electronic Controller ACO Panel Flexible Connections Clamps Silencer 300mm Silencer 600mm Silencer 900mm Silencer 1200mm Wiring Diagram STDR200-1EC 149-POT-10 149-ACO14E 018-0200-FLEX 018-200-CLAMP 068-0200-JF1 068-0200-JF2 068-0200-JF3 068-0200-JF4 152-000236 STDR250H-1EC 149-POT-10 149-ACO14E 018-0250-FLEX 018-250-CLAMP 068-0250-JF1 068-0250-JF2 068-0250-JF3 068-0250-JF4 152-000236 STDR250L-1EC 149-POT-10 149-ACO14E 018-0250-FLEX 018-250-CLAMP 068-0250-JF1 068-0250-JF2 068-0250-JF3 068-0250-JF4 152-000236 STDR315-1EC 149-POT-10 149-ACO14E 018-0315-FLEX 018-315-CLAMP 068-0315-JF1 068-0315-JF2 068-0315-JF3 068-0315-JF4 152-000244 STDR400-1EC 149-POT-10 149-ACO1/B 018-0400-FLEX 018-400-CLAMP 068-0400-JF1 068-0400-JF2 068-0400-JF3 068-0400-JF4 152-000244 STDR500-1EC 149-POT-10 149-ACO1/B 018-0500-FLEX 018-500-CLAMP Please enquire. 152-000244 Electronic Controller ACO Panel Flexible Connections Clamps Silencer 300mm Silencer 600mm Silencer 900mm Silencer 1200mm Wiring Diagram STDR500-3EC 149-POT-10 149-ACO3/B 018-0500-FLEX 018-500-CLAMP Please enquire. 152-2MOEA03K3 Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 8

Notes Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 9

DCV Roof Mounted Direct Drive Twin Centrifugal Fan OVERVIEW The Twinflow STDR DCV...EC incorporates the BAT (Best Available Technology) Vpro backward curved impeller, with three dimensional profiled blades powered by the ultra reliable Ziehl-Abegg EC (electronically commutated) external rotor motor. The range of twin roof fans are suitable for external mounting, manufactured in Aluzinc with a natural finish. Refer to Twinflow STDR on pages 161-168 for Performance & Electrical Data. For DCV information refer to pages 228-229. QUICK FACTS ü 5 standard sizes from 200mm to 500mm. ü Air volume flow rates up to 1.65 m³/s (EC). ü Static pressures up to 960 Pa (EC). ü Suitable for operating temperatures up to +60 C. ü Extensive range of stock available. ü Available in EC. Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 10

Applied Technology Tel: +44 (0) 1489 566500 Fax: +44 (0) 1489 566555 Email: at@eltafans.co.uk 17 Barnes Wallis Road, Segensworth East Industrial Estate, Fareham, Hampshire, PO15 5ST United Kingdom Building Services Tel: +44 (0) 1384 275800 Fax: +44 (0) 1384 275810 Email: bs@eltafans.co.uk 46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands, DY6 7US United Kingdom Export Tel: +44 (0) 1489 566500 Fax: +44 (0) 1489 566555 Email: export@eltafans.co.uk 17 Barnes Wallis Road, Segensworth East Industrial Estate, Fareham, Hampshire, PO15 5ST United Kingdom www.eltafans.com BS EN ISO 9001:2008 FM 556465 A member of HEVAC ASSOCIATION