Power Relays RL Series PRODUCT DESCRIPTION Quick Connect Flange Mount SPECIFICATIONS Number of poles pole 2 poles Contact Configuration X (SPST, double make) 2X (DPST, double make) Contact material Ag Alloy Ag Alloy Operating Time and Release Time 0ms max 0ms max Degree of Protection IP40 IP40 Dielectric strength Vibration Resistance Shock Resistance Electrical Life (rated load). Operation frequency (800 operations per hour) RL Between contact and coil 4,000V AC for minute 4,000V AC for minute Between pole 2,000V AC for minute 2,000V AC for minute Between contact sets - 2,000V AC for minute Operating extremes Damage limits DIN Rail Mount Frequency 0 to 55 Hz, Frequency 0 to 55 Hz, Frequency 0 to 55 Hz, Frequency 0 to 55 Hz, Operating extremes 00 m/s² (0G) 00 m/s² (0G) Damage limits,000 m/s² (00G),000 m/s² (00G) AC resistive load 200,000 operations min 200,000 operations min Inductive load 00,000 operations min 00,000 operations min Mechanical Life (without load),000,000 operations min,000,000 operations min Designed with a - and 2-pole HP/277V AC rating in an economical and compact package, 0A RL power relays are the superior choice for HVAC panels, energy management and applications requiring higher voltage loads and inductive kickback. Choose from panel or DIN rail mounting. Unlike the competition, when DIN rail mounted, RL relays don t require a socket or adaptor. Quick Connect terminals allow faster installation on commercial applications, while screw terminations are ideal for industrial applications. KEY FEATURES HP at 277VAC,.5HP at 20VAC Single pole rated at 0A, double pole at 25A Double Make contacts Flange mount or DIN-rail mount with panel mount tabs #2 quick-connect or screw terminations AC or DC Coil Inputs Designed for Motor, Lighting, and Heater Loads Up to 70 VA maximum switching power RoHS compliant Operating Temperature -25 to +55 C -25 to +55 C Operating Humidity Weight 5 to 85% (without condensation) Between 90 and 5 grams, depending on model 5 to 85% (without condensation) Between 90 and 5 grams, depending on model STANDARDS COMPLIANCE Agency ratings RL Standard current ratings HP ratings FLA and LRA ratings 0 A, 277 Vac, General Use, 00,000 Cycles 25 A, 277 Vac, General Use, 00,000 cycles.5 HP, 20 Vac, 0,000 Cycles.5 HP, 20 Vac, 0,000 Cycles HP, 277 Vac, 0,000 Cycles HP, 277 Vac, 0,000 Cycles 20 FLA, 20 LRA, 20 Vac, / Hz, 0,000 Cycles 7 FLA, 02 LRA, 277 Vac, / Hz, 0,000 Cycles 20 FLA, 20 LRA, 20 Vac, / Hz, 0,000 Cycles 7 FLA, 02 LRA, 277 Vac, / Hz, 0,000 Cycles
COIL RATINGS Rated Coil Code Rated Current (ma) ±0% Coil Resistance (Ω) Pickup Operating Characteristics at 20 C Dropout Maximum Allowable Power Consumption DC 2V D2 75.9W 80% max 5% min 0% 24V D24 79.0 0.9W Rated Coil Code Rated Current (ma) +5% -25% Hz Hz Coil Resistance (Ω) Pickup Operating Characteristics at 20 C Dropout Maximum Allowable Power Consumption AC (-Hz) 24V A24 7.0 69.5 -.7-2.5VA 00V - 20V A00 7.0 6.6-80% max 0% min 0%.7-2.5VA 200V - 240V A200 8.5 8. -.7-2.5VA CONTACT RATINGS RL Allowable Contact Power Resistive load 70VA 62VA Rated Load Resitive load 2VAC 0A, 0VDC 0A 2VAC 25A, 0VDC 25A Allowable Switching Current 0A 25A Allowable Switching 277VAC PART NUMBERS Flange Mount Coil voltage DC AC Pole Flange Mount Pole Flange Mount 2V RLN-T-D2 N-T-D2 RLB-T-D2 B-T-D2 24V RLN-T-D24 N-T-D24 RLB-T-D24 B-T-D24 24V RLN-T-A24 N-T-A24 RLB-T-A24 B-T-A24 00V - 20V RLN-T-A00 N-T-A00 RLB-T-A00 B-T-A00 200V - 240V RLN-T-A200 N-T-A200 RLB-T-A200 B-T-A200 DIN Rail Mount with Panel Mount Tabs Coil voltage Pole DIN Rail DC AC 2 Pole DIN Rail pole DIN Rail 2V RLN-D-D2 N-D-D2 RLB-D-D2 B-D-D2 24V RLN-D-D24 N-D-D24 RLB-D-D24 B-D-D24 24V RLN-D-A24 N-D-A24 RLB-D-A24 B-D-A24 2 Pole DIN Rail 00V - 20V RLN-D-A00 N-D-A00 RLB-D-A00 B-D-A00 200V - 240V RLN-D-A200 N-D-A200 RLB-D-A200 B-D-A200 Part Number Structure Series Name Contact Arrangement : Form X 2 : 2 Form X Terminal Construction B : N : RL B - T-A 00 Input 2 : 2V 24 : 24V 00 : 00-20V 200 : 200-240V D : DC (: 2, 24V) A : AC /Hz (: 24, 00-20, 200-240V) Mounting T : Flange Mount D: DIN Rail Mount with panel mount tabs
DIMENSIONS (All dimensions in mm, except where noted.) RLN-T Pole Flange Mount N-T 2-M4 4-M4 4 4 49 49 Recommended tightening torque: Coil terminals (M.5): 0.7-0.9 N m, Contact terminals (M4):.0 -.4 N m RLB-T Pole Flange Mount 6.4 B-T 4 40 6. 0.8 5 0.2 #2 quick connect 0.25 terminations 0.2 6. #2 quick connect 0.25 terminations 0.8 5
RLN-D Pole DIN Rail Mount N-D 2 Pole DIN Rail Mount 2-M4 4-M4.0 5.4 5.4 Recommended tightening torque: Coil terminals (M.5): 0.7-0.9 N m, Contact terminals (M4):.0 -.4 N m RLB-D Pole DIN Rail Mount B-D 2 Pole DIN Rail Mount 6.4 4 0.2 40 #2 quick connect 0.25 terminations 6. 0.8 0.2 6. 9.5 #2 quick connect 0.25 terminations 0.8 9.5
ACCESSORIES Description Color Part Number Finger-safe terminal cover Clear RL9Z-C Applicable for screw terminal models only TERMINAL ARRANGEMENTS (TOP VIEW) Pole Flange Mount Pole Flange Mount Pole DIN Rail Mount Pole DIN Rail Mount 2 4 2 4 2 Pole DIN Rail Mount 2 Pole DIN Rail Mount MOUNTING HOLE DIMENSIONS Flange Mount DIN Rail Mount with Panel Mount Tabs 2-M4 or ø mounting holes 2-M4 or ø mounting holes ±0. ±0.2 ±0.2 Recommended tightening torque: 0.6-0.9 N m
Recommended ring or fork terminations for screw terminals. Contact Terminals Coil Terminals 9.5 max. ø4.2 min. 9.5 max. 4.2 min. 8.0 max. ø.6 min. 8.0 max..6 min. Electrical Life Curves RL pole 000 2 poles 000 Life( 0,000 operations) 00 0 AC2V DC0V Life( 0,000 operations) 00 0 AC2V DC0V 0 4 8 2 6 20 24 28 2 6 0 4 8 2 6 20 24 28 2 6 Maximum Switching Capacity RL pole 00 AC Resistive Load 2 poles 00 25 0 DC Resistive AC Inductive load (p.f=0.4) 25 0 DC Resistive AC Resistive Load AC Inductive load (p.f=0.4) 0. 0 00 2 277 000 Contact (V) 0. 0 00 2 277 000 Contact (V) IDEC Corporation 75 Elko Drive Sunnyvale, CA 94089 800-262-IDEC (42) Fax: 408-7-5258 www.idec.com/usa 207 IDEC Corporation. All Rights Reserved. RV9Y-DS200-0a 04/7 pdf only