Short Manual. PIKO 6.0 BA / 8.0 BA / 10 BA with Energy Management

Similar documents
Short Manual. PIKO 6.0 BA / 8.0 BA / 10 BA with Energy Management

Short Manual. PIKO Inverter

Powerstocc Excellent. Short Manual. PS DC Storage.

Data sheet PIKO 12-20

Data sheet. PLENTICORE plus. plus

Data sheet. PIKO MP plus

Data sheet PIKO IQ

Data sheet PIKO 36 EPC EPC

SolarMax P series The power package for residential solar plants

Pre-announcement. Transformerless Solar Inverters

SolarMax MT series The all-rounder for trade and industry

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Catch Eco Range : Technical Specification Sheet

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

Technical specifications

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

SolarMax MT series. The power pack for maximum yields.

SolarMax S series (Australia) Maximising solar plant yields can be so easy.

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

500 / 630 / 720 / 760 / 800 / 850 / 900

Get ready for rising energy challenges. This is where xstorage Home can help

/ The personal storage solution for 24H sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

Sunny Tripower. Can do everything that we can

Smart connections. Certificates. PIKO-Inverter

ABB string inverters PVI-3.8/4.6-I-OUTD 3.8 to 4.6 kw

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

SolarMax MT A series A reliable solution for commercial PV applications

photovoltaikforum.com

/ Optimised energy management. / Dynamic Peak Manager. / Smart Grid Ready 12.0 A / 12.0 A 18.0 A / 18.0 A

Certificate of Conformity self-generation unit

PV inverter SUNNY MINI CENTRAL 7000HV

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

INVEOR "Smart connections." on five levels

SUNNY TRIPOWER CORE1 60% UP TO. faster installation for commercial PV systems. Subline lorem ipsum dolor sit amet EN DE STANDS ON ITS OWN

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS-Q 1.2 to 5.0 kw

ABB string inverters PVI-3.0/3.6/4.2-TL-OUTD 3 to 4.2 kw

SolarMax 50TS/80TS/100TS/300TS. Ready for the future.

Installation and Operation manual

Sunny Tripower CORE1.

Technical specifications

SIZING OF SOLAR GENERATOR

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS 1.2 to 5.0 kw

SMA COMMERCIAL PRODUCTS SUNNY TRIPOWER CORE1. Stands on its own. Up to 60 % faster installation for commercial PV systems

Residential Energy Storage System SH5K PV ESS

APS-PV-Series 1000 V DC

Operating manual UPS - System

SolarMax S series (United Kingdom) Maximising solar plant yields can be so easy.

CONERGY CIS 1200 Manufactured By Bosch

Residential Energy Storage System SH 5K

TANZANIA BUREAU OF STANDARDS

THREE-PHASE STORAGE SOLUTION EFFICIENT MODULAR REVOLUTIONARY

7 MODES OF OPERATION INVERTER STATUS Standby: The PV string can only provide just enough voltage to minimum requirements of the controller.

ABB central inverters PVS to 1000 kw

Accessories for power generation plants in Italy SMA GRID GATE

Green Inverters from. Solar inverters. for Asia. Solar inverters. for Europe. Solar inverters. for America. Solar inverters.

PV inverter SUNNY BOY 2100TL

* Protected from tools and particles greater than 2.5 millimeters * Protected form low pressure water jets from any direction

FRONIUS ENERGY PACKAGE

Power conversion systems for energy storage. Engineering that stores

Technical Documentation

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

PowerRouter Solar Battery Self-use

PRO-TYP II. Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA

Price list - Inverter

8 Troubleshooting and Maintenance

SolarMax 330TS-SV. The all-round solution for large-scale PV installations.

Oil-free piston compressors KK and piston vacuum pumps KV

THREE-PHASE FRONIUS ENERGY PACKAGE. EFFICIENT / High-performance lithium iron phosphate

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

Total number of PV modules: 42 Energy usability factor: 99.9 % Number of PV inverters: 1

PIKO BA System smart, communicative and autonomous

BLU SERIES Battery Load Units

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

Operating instructions

FRONIUS SNAPINVERTERS SMARTER, LIGHTER, MORE FLEXIBLE

Energy Meters for Solar-Log Product Information

Wind Power Inverter WINDY BOY 5000A/6000A

Integrated Plant Control and Q on Demand 24/7 SUNNY TRIPOWER

Operating Instructions for Roll-Up Door Operators / MDF

Retrofit to Single phase / Three phase PV system Micro-grid, UPS, Peak shift, Pure off-grid retrofitting etc multi-working

PowerValue 11/31 T kva

THREE-PHASE. FRONIUS ENERGY PACKAGE / The personal storage solution for 24 hours of sun. EFFICIENT FLEXIBLE REVOLUTIONARY

40 Módulos FV TRINA SOLAR 265Wp Policristalino (Estructura Incluida) 1 Inversor KACO Blueplanet 10,0 TL3

ABB central inverters PVS to 1000 kw

THREE-PHASE FRONIUS ENERGY PACKAGE. EFFICIENT / High-performance lithium iron phosphate

PV Inverter SUNNY BOY 3300/3800

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

A flexible and efficient residential solar solution. Conext RL single-phase grid-tie inverter

Installation Instructions

Delta All-In-One Storage solutions

SolarMax 20C/25C/30C/35C. Proven reliability.

SOLON SOLiberty Energy Storage Solution. Greater Independence Through On-site Consumption.

Operating Instructions (Translation)

+86(571) (571) (V4)

Development of the Single Phase PV Inverter SANUPS P61A

Transcription:

Short Manual PIKO 6.0 BA / 8.0 BA / 10 BA with Energy Management

EU Declaration of conformity The company KOSTAL Solar Electric GmbH Hanferstraße 6 79108 Freiburg i. Br. Germany hereby declares that the inverters described in this document are the essential requirements and other relevant provisions of the below mentioned guidelines in accordance. Directive 2014/30/EU (Electromagnetic compatibility, EMC) Directive 2014/35/EU (Electrical Apparatus Low Voltage Directive) A detailed EU declaration of conformity can be found at: www.kostal-solar-electric.com/download/zertifikate 2 3

Proper use The PIKO BA inverter converts DC current into AC current. The current can be used for the following: nn for consumption nn to store the current in the battery of the system (PIKO BA System) nn for feeds into the public mains grid The unit may only be used in grid-connected photovoltaic systems within the permissible power range and under the permissible environmental conditions. The device is not intended for mobile use. Inappropriate use can be hazardous and lead to injury or even death of the user or third parties. Material damage to the device and other equipment can also occur. The inverter may therefore only be used for its intended purpose. The PIKO BA Inverter is equipped with an energy management system. This system controls based on technical and economic aspects of the use of electricity generated. Exclusion of liability Any use that differs from or goes beyond the stated intended purpose is considered inappropriate. The manufacturer accepts no liability for any damage resulting from this. Modifications to the inverter are prohibited. The inverter may only be used if safe to operate and in technically perfect condition. Any instance of misuse will cause the termination of the warranty, guarantee and general liability of the manufacturer. Only a qualified electrician may open the device. The inverter must be installed by an electrician who is responsible for observing the applicable standards and regulations. Work that could affect the electrical power system of the respective utility company at the site of the solar energy feed-in may only be carried out by qualified electricians expressly authorised (licensed) by the utility company. This includes changes to the factory preset parameters. The installer must always observe the regulations of the utility company. The utility company s specifications must always be observed when setting the parameters. Additional User Information For additional information, please read the complete operation manual on the CD. User Manual 4 5

Type plate Scope of delivery 1 2 3 8 10 12 13 14 15 16 20 Hanferstraße 6 D-79108 Freiburg +49 (0) 761-47744-100 www.kostal-solar-electric.com XXXXXXX 4 Item no.: XXXXXXXX 5 DCinput: VMPP = XXX...XXX V VDC_MAX = XXX V 6 IDC_MAX = XXX A IPV_SC = XX.X A 7 VBatt_MAX = XXX V IBatt_MAX = XX A 21 ACoutput: XN~, XXXV, XXHz, max. XX.X A 22 XXXXX VA (cosϕ=0.9...1) 9 Protective Class I, IP XX -20 C...60 C, OVC DC:II / AC:III 11 VDE V 0126-1-1 Art.-No.: NNNNNNNN Ser.-No.: XXXXXABCXXXXX HW: YYXXXX PAR: XX.XX FW: XX.XX UI: XX.XX Serviceupdate: XXXXXXXX XXXXABCXXXXX 17 18 19 1 Name and address of manufacturer 2 Device type 3 Item number 4 MPP control range 5 Maximum DC input voltage 6 Maximum DC input current 7 Maximum DC short circuit current 8 Number of feed-in phases, Output voltage (nominal), frequency, Maximum AC output current 9 Maximum AC power 10 Protective class to IEC 62103, Protection type and ambient 11 Temperature range, overvoltage category 12 Requirements conforming to those of the built-in grid monitoring 13 Internal item number 14 Serial number 15 Version of hardware 16 Version of firmware 17 Version of parameter set 18 Version of user interface 19 Date of the last update 20 Removable guarantee label 21 Maximum input voltage battery 6 7 22 Maximum input current battery 4x L1 L2 L3 N PE 1x User Manual Safety Notes

Selecting the installation side NOTE Observe the following instructions, or else warranty claims will be restricted. Protect from rain and water. Select stable installation location. No plasterboard or wooden walls. Protect from direct sunlight. Prevent access by children. Select non-flammable installation location. 200 100 Required cooling space is 200 mm vertical and 100 mm horizontal. Maintain safe distance from flammable materials or areas at risk of explosion. NH3 Protect from dust, contamination and ammonia. 90 Select vertical installation location. Ensure easy access and visible display. C/ F % Ambient temperature must be between -20 C and +60 C. Air humidity must be between 4 % and 100 % (condensing). Ensure that people are not disturbed by operating noise. 8 9

To lift the inverter Installation Cooling space 1. 100 45 200 Mounting spaces Lift here! max.10 20 45 100 Lift here! 74 2. 200 3. 10 PIKO BA-Inverter 11

Connecting AC and DC side LEBENSGEFAHR DURCH STROMSCHLAG! ОПАСНОСТ ЗА ЖИВОТА ПОРАДИ ТОКОВ УДАР. Wechselrichter spannungsfrei schalten. Изключвайте инвертора от напрежението. RISK OF DEATH DUE TO ELECTRICAL SHOCK! LIVSFARA PÅ GRUND AV ELEKTRISK STÖT! De-energise the inverter. Koppla växelriktaren spänningsfri. DANGER DE MORT PAR ÉLECTROCUTION! ZAGROŻENIE ŻYCIA PRZEZ PORAŻENIE PRĄDEM! Mettre l onduleur hors tension. Odłączyć falownik od zasilania. PELIGRO DE MUERTE DEBIDO A ELECTROCUCIÓN! ELEKTRILÖÖGI OHT! Desconectar el inversor de la tensión. Lahutage vaheldi vooluvõrgust. PERIGO DE MORTE DEVIDO A CHOQUE ELÉTRICO! PAVOJUS GYVYBEI DĖL ELEKTROS SROVĖS SMŪGIO! Desligar a tensão de corrente do inversor. Inverteriui nutraukite įtampos tiekimą. PERICOLO DI MORTE PER SCOSSA ELETTRICA! ELEKTRISKĀS STRĀVAS TRIECIENA BRIESMAS! Eliminare la tensione dall inverter. Atslēgt invertoru no strāvas. LIVSFARE PGA. ELEKTRISK STØD! OPASNOST PO ŽIVOT OD STRUJNOG UDARA! Vekselstrømsomformeren skal kobles fra spændingen. Isključiti izmjenjivač. LEVENSGEVAAR DOOR ELEKTRISCHE SCHOK! OPASNOST PO ŽIVOT ZBOG STRUJNOG UDARA! Schakel de omvormer spanningsvrij. Isključiti izmjenjivač. OHROŽENÍ ŽIVOTA ELEKTRICKÝM PROUDEM! OPASNOST PO ŽIVOT USLIJED STRUJNOG UDARA! Odpojte střídač od napětí. Izmjenjivač isključite sa naponskog napajanja. PERICOL DE ELECTROCUTARE! OPASNOST PO ŽIVOT USLED STRUJNOG UDARA! Scoateţi ondulorul de sub tensiune. Izmenjivač isključite sa naponskog napajanja. SMRTNA NEVARNOST ZARADI ELEKTRIČNEGA UDARA! Razsmernik odklopite iz električne napetosti. De-energising inverter: NEBEZPEČENSTVO OHROZENIA ŽIVOTA ZÁSAHOM 1. OFF ON 2. 3. 4. 5. ELEKTRICKÉHO PRÚDU! 5 min Menič prepnite do beznapäťovej prevádzky. OFF ELEKTRIK ÇARPMASI NEDENIYLE HAYATI TEHLIKE! İnvertörü gerilimsiz hale getirin. Switch off DC side Switch off Safeguard Disconnect Wait 5 minutes ΚΊΝΔΥΝΟΣ ΘΑΝΆΤΟΥ ΑΠΌ ΗΛΕΚΤΡΟΠΛΗΞΊΑ! 1. At Inverter - AC side DC side Αποσυνδέστε τον αντιστροφέα από το ρεύμα. 2. At Batterysystem - S0/AL-out 12 (when connected) - Battery (when connected) 13

Connecting AC, DC and battery side Option: Connecting Backup Unit F900 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 L1.k L1.l L2.k L2.l L3.k L3.l Connecting control line Backup Unit Connecting battery Connecting sensor Connecting AC - 1 2 - + + Connecting Backup Unit Sensor Battery DSL / LAN CAN or Backup RS485 bus Unit AC 14 Connecting DC side Connecting Backup Unit (optional equipment) 15

Country-specific installation Option: Connecting DC1 & DC2 in parallel DC1 DC2 Battery L1 L2 L3 N PE Connecting main cable with sealing cap NOTE 3 Nm When using the parallel connection this feature must be activated under the menue Settings >> Service menu >> String 16 Second ground connection connection >> Parallel connection (only with service code). 17

Data transfer Communicationboard II Commissioning the inverter DSL or LAN and CAN or RS485 bus 1. 5 Nm CAN or RS485 module DSL / LAN CAN or RS485 bus 2. ON 3. OFF ON 18 19

Installation Wizard* Language German 1. Select language 2. H Enter Language Select > 3. Enter Date / time 4. H Enter German Enter 5. Select string connection 6. H Enter 7. Select modus of the current sensor 8. H Enter Country setting 9. Select country Do you really want to apply this country? No Yes 10. H Enter 11. Confirm Country settings with YES 12. H Enter 20 * Deviations due to software versions (UI level) is possible. 21

Menu overview* Menu DC and AC DC menu DC menu Settings menu AC menu DC input 1 (U,I,P) DC input 2 (U,I,P) Battery menu Own consumption menu AC menu Phase 1 (U,I,P) Phase 2 (U,I,P) Phase 3 (U,I,P) Total yield Yield (MWh) Operation time (h) Grid parameters Limitation on (%) Grid frequency (Hz) cos φ Daily yield (diagram) Monthly yield (diagram) Annual yield (diagram) Total yield (diagram) 22 * Deviations due to software versions (UI level) is possible. 23

Settings menu 1 Basic settings Language Select language Inverter name Date / time Entering the name Set date / Set time of day Communication Network settings 1 Auto IP Network settings 2 IP address / Subnet mask Router settings External router / Router IP RS485 settings Bus termination / Bus bias voltage / RS485 address Portal configuration Portal code / Data export Event messages Immediately mailing On / Off Device information SW/HW version FW / HW / UI / PAR Serial number Serial number Country setting Country setting Function test Fan test Service menu Service code 2 Factory settings 1 Deviations due to software versions (UI level) is possible. 2 After entering the code, additional menu items appear to configure the inverter. 24 The code can be obtained by electricians from our customer service. 25

Menu Battery* Menu Own Consumption* Battery status 1 Charging status (%) Voltage (V) Charging (A) (Charge/Discharge) Daily self-consumption Self-consumption (Wh) Self-consumptions rate (%) Self-sufficiency (%) Battery status 2 Temperature (C ) Charge cycles Total self-consumption Self-consumption (Wh) Self-consumptions rate (%) Self-sufficiency (%) Current build. consump Solar generator (W) Battery (W) Grid (W) Phase-sel. consumption Phase 1 (W) Phase 2 (W) Phase 3 (W) 26 * Deviations due to software versions (UI level) is possible. 27

Technical data Inverter PIKO Unit 6.0 BA 8.0 BA 10 BA Input side (DC) Inverter type PIKO Max. PV power kwp 6.6 8.8 11 Recommended PV power kwp MPP range with rated DC power V 260-850 350-850 440-850 Max. input voltage (U dcmax ) V 950 Min. input voltage (U dcmin ) V 180 Rated input current A 11.5 Max. input current (I dcmax ) A 12 Max. input current with parallel connection A 24 Number of DC inputs 2 Number of independent MPP trackers 2 Battery input side (DC) Max. battery input voltage V 420 Min. battery input voltage V 153 Max. charge current A 12 Max. discharge current A 12 Inverter PIKO Unit 6.0 BA 8.0 BA 10 BA Output side (AC) Rated output, cos j = 1 (P ac,r ) kw 6 8 10 Max. output apparent power, cos φ, adj kva 6 8 10 Rated output current A 8.7 11.6 14.5 Max. output current (I acmax ) A 9.7 12.9 17.5 short circuit current (Peak / RMS) A 19 / 12,2 Number of feed-in phases 3 Grid connection 3N~, AC, 400 V Rated frequency (f r ) Hz 50 Ext. current sensor Rated current primary (Peak/RMS) A 50/35 Precision method 1 Dimensions (H x W x D) mm (inch) 90 x 105 x 54 (3.54 x 4.13 x 2.13) Max. cable diameter mm (inch) 13.5 (0.53) Mounting on top hat rail to DIN EN 60715 H Efficiencies Max. efficiency % 96.1 96.3 96.5 Max. European efficiency rate % 94.8 95.0 95.3 28 29

Inverter PIKO Unit 6.0 BA 8.0 BA 10 BA System data Inverter PIKO Unit 6.0 BA 8.0 BA 10 BA System data Topology: without galvanic separation - transformerless H Internal protection according to IEC 60529 IP 55 Protection class according to IEC 62109-1 I Overvoltage category according to IEC 60664-1 Input side (PV-generator) II Overvoltage category according to IEC 60664-1 Output side (grid connection) III Degree of contamination 3 Enviromental category (outdoor installation) Enviromental category (interior installation) UV-resistance Minimum cable cross-section of AC-connect-inline Minimum cable cross-section of DC-connect-inline Max. fusing on output side H H H mm² 2.5 mm² 4 B25, C25 Tightening torque of PE connection, outer Nm 3 Tightening torque of lid screws Nm 5 Operation protection (EN62109-2) RCCB Typ B Electronic disconnection device integrated H Height mm (inch) 450 (17.72) Width mm (inch) 520 (20.47) Depth mm (inch) 230 (9.06) Weight kg (lb) 33 (72.75) Max. air throughput m³/h 188 Max. noise emission dba 46 Ambient temperature C ( F) -20...60 (-4...160) Max. installation altitude m above sea 2000 level Relative humidity (condensing) % 4 100 Connection technology at input side MC 4 H Connection technology at output side spring-loaded terminal strip H 30 31 Various Warranty Years 5 Warranty extension optional Years 10 / 20

Service Hotline Germany +49 761 47 74 42 22 and other countries 1 1 Language: German, English 06 / 2016 edition, subject to technical changes and printing errors.