Product Data. Residential Zone Dampers FEATURES/BENEFITS

Similar documents
Product Data ZONE DAMPERS FEATURES/BENEFITS. Fig. 3 - Slip -In Damper. Fig. 1 - Round Damper

Product Data ZONE DAMPERS FEATURES/BENEFITS. Fig.3 Slip-InDamper. Fig.1 RoundDamper

ZONE DAMPERS. Form No. PDS DAMP.0.3

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES

Product Data ZONEKIT4ZCAR. Comfort Zone Residential Zoning System

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Installation Instructions

Product Data. FNCCAB & FILCCFNC High Efficiency Fan Coil Filtration. Sizes 014, 017, 021 & 024. FNCCAB Filter Cabinet. FILCCFNC Media Filter

Product Data. FILCAB, FILCAR & EZ Flex Efficient Mechanical Air Cleaner. Sizes 016, 020, 024. FILCAB Filter Cabinet. FILCAR Media Filter

Installation Instructions

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

SD-1250 and SD-1600 Series Smoke Dampers

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES

Installation and Start-Up Instructions

Product Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest

Air Flow Factors. Alnor Model 6070, 6000, 2220, or 2220-A Probe Orientation

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

CCS Zone/Bypass Damper Assembly

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Product Data. SYSTXCCUIZ01-- V Infinityt Zone Control. INFINITY t ZONE CONTROL

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

Product Data. SYSTXBBUIZ01 -D Evolutiont Zone Control. EVOLUTION t ZONE CONTROL

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh)

FOR USE IN SOLUTION AIR HANDLING UNITS

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

Complete HVAC Capability

Product Data. SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control. EVOLUTION r CONNEX t CONTROL

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

PIM Pressure Independence Module

INFINITY ZONING QUICK START GUIDE

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

YCCS Zone/Bypass Damper Assembly

MODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

Product Data. SYSTXCCITC01---B Infinityr System Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR SYSTEM CONTROL

ILL. 1. Horizontal. supply air cover panel shipped on HVAC unit. Access door/ panel

CAT PAU 99(2) SUPERSEDES CAT.NO SARAVEL PACKAGED AIR CONDITIONING UNITS

HCD-230 Industrial Control Damper

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

SINGLE DUCT TERMINAL UNITS 3000 SERIES

B1-2. Table of Contents LOUVERED FACE DIFFUSERS

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

Product Data. SYSTXBBECC01-B Evolutionr Connext Control INDUSTRY LEADING FEATURES/BENEFITS. EVOLUTION r CONNEX t CONTROL

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.

Installation Instructions

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE

PIM Pressure Independent Module

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

CLASS 4FANS BACKWARDLY INCLINED CENTRIFUGAL. Visit us on the Web: Phone: (800)

Laboratory Exhaust Systems

Start-Up, Operation and Service Instructions

SYST0101ZP Ion Damper Control Installation and Start---Up Instructions

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Product Information. Applications. Warranty. Lab Calibrated. Residential, Commercial, OEM. ABV Sizes Available Airflow Range THE USA PROUDLY MADE IN

DS4BD-KB Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Air Conditioner 13 SEER Residential System 1.

TECHNICAL SPECIFICATIONS

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

Demand Based Static Pressure Reset Control for Laboratories

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1

YCCS Zone/Bypass Damper Assembly

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

Product Data. that this product meets the S 95% AFUE S Two -stage operation

Installation, Start-Up and Service Instructions

Solutions from SPTT-3

Installation and Start Up Instructions

D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS

PC-125x Counter-Balanced Backdraft Damper

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

BAC, BAF, BAH Central Station Air Handlers

HMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

FNCCAB and FILXXFNC High Efficiency Fan Coil Filtration Sizes 14, 17, 21 and 24. Product Data A FNCCAB Filter Cabinet

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Variable Air Volume Dampers

Installation Instructions

FNCCAB & FILBBFNC Sizes 014, 017, 021 & 024

GRAVITY VENTILATORS SIZING

EGG CRATE RETURN GRILLE

Laboratory Exhaust Systems

FILCAB, FILCAR & EZ Flex Sizes 016, 020, 024

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

RPD ROUND PLAQUE DIFFUSER

LOUVERED FACE GRILLES AND REGISTERS

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

Product Data. Filter Cabinet (FILCAB) Cartridge Filter (FILCAR) EZ Flext (EXPXX) Sizes 16, 20, 24. Filter Cabinet (FILCAB) Cartridge Filter (FILCAR)

Product Overview. Hansen Precision Electric Motors DC AC DC. Actuators. Stepper

MOUNTING ARRANGEMENT OPTIONS OVERVIEW

HMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

VANEAXIAL & TUBEAXIAL FANS

TECHNICAL SPECIFICATIONS

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

INLET BOXES AND INLET-BOX DAMPERS

Transcription:

Product Data Residential Zone Dampers FETURES/ENEFITS IRFLOW CLS COM OPN IRFLOW 90 0 45 ROUND DMPER CLS COM OPN 90 0 45 RECTNGULR DMPER Carrier residential zone dampers are the latest in design and were developed to fit field requirements for a variety of duct work shapes and sizes. These dampers use 24 vac direct drive actuators for smooth quiet performance. There is a 1/2-in. directdrive mounting hub for securing the damper blade and shaft to the actuator housing. position indicator and angular rotation stop for viewing or manually setting minimum-maximum damper positions facilitate ease of installation. spring loaded disengagement button to momentarily release main gear and damper blade allows for proper positioning of installed dampers. The damper motor and terminal block wiring are protected in a plastic cover with a removable door. Permanently lubricated bushings with a split shaft design for round and rectangular style dampers, secure the damper blade to the shaft for efficient reliable service. SLIP-IN DMPER Copyright 1996 Carrier Corporation Form DMP-1PD

Model number nomenclature DMP SLS 08x10 Damper Length x Width, Diameter INC for Round Slip-In Side Mount (SLS) Slip-In ottom Mount (SL) Round (RND) Rectangular (REC) arometric (R) 2

Slip-Ins SIDE MOUNT IR DUCT 3 4 4 2 1 8 5 NGULR ROTTION STOPS 3 1 8 SIDE RIL 1 LISTED DMPER HEIGHT 1 6 1 8 CLS OPN QUICK LDE RELESE UTTON (RED) SIDE RIL 95397 OTTOM MOUNT SIDE RIL SIDE RIL IR DUCT 1 6 1 8 NGULR ROTTION STOPS 3 1 8 3 4 2 1 8 4 5 CLS OPN LISTED DMPER WIDTH 1 QUICK LDE RELESE UTTON (RED) 95398 3

Slip-Ins continued SLIP-IN DMPER DIMENSIONS (In.) PRT NO. POSITION DMPSLS08x10 side mount 9-7/8 7-13/16 DMPSL08x10 bottom mount 7-13/16 9-7.8 DMPSLS08x12 side mount 11-7/8 7-13/16 DMPSL08x12 bottom mount 7-13/16 11-7/8 DMPSLS08x14 side mount 13-7/8 7-13/16 DMPSL08x14 bottom mount 7-13/16 13-7/8 DMPSLS08x16 side mount 15-7/8 7-3/16 DMPSL08x16 bottom mount 7-13/16 15-7/8 DMPSLS08x18 side mount 17-7/8 7-13/16 DMPSL08x18 bottom mount 7-13/16 17-7/8 DMPSL08x20 bottom mount 7-13/16 19-7/8 DMPSL08x22 bottom mount 7-13/16 21-7/8 DMPSL08x24 bottom mount 7-13/16 23-7/8 DMPSLS10x10 side mount 9-7/8 9-13/16 DMPSL10x10 bottom mount 9-13/16 9-7/8 DMPSLS10x12 side mount 11-7/8 9-13/16 DMPSL10x12 bottom mount 9-13/16 11-7/8 DMPSLS10x14 side mount 13-7/8 9-13/16 DMPSL10x14 bottom mount 9-13/16 13-7/8 DMPSLS10x16 side mount 15-7/8 9-13/16 DMPSL10x16 bottom mount 9-13/16 15-7/8 DMPSLS10x18 side mount 17-7/8 9-13/16 DMPSL10x18 bottom mount 9-13/16 17-7/8 DMPSL10x20 bottom mount 9-13/16 19-7/8 DMPSL10x22 bottom mount 9-13/16 21-7/8 DMPSL10x24 bottom mount 9-13/16 23-7/8 DMPSL14x20 bottom mount 13-13/16 19-7/8 C 4 3 1 8 6 1 8 ROUND DMPER (In.) 95399 PRT NO. C DMPRND06INC 16 18 6-1/2 DMPRND08INC 18 18 6-1/2 DMPRND10INC 10 18 6-1/2 DMPRND12INC 12 24 10-1/2 DMPRND14INC 14 24 10-1/2 DMPRND16INC 16 24 10-1/2 4

Slip-Ins continued 1 1 2 6 1 2 C D E 7 6 1 8 4 3 1 8 1 2 4 PLCES RECTNGULR DMPER (In.) PRT NO. C D E DMPREC08x10 18 10 2-1/4 13-1/2 12-1/4 DMPREC08x14 18 14 2-1/4 13-1/2 12-1/4 DMPREC08x18 18 18 2-1/4 13-1/2 12-1/4 DMPREC08x24 18 24 2-1/4 13-1/2 12-1/4 DMPREC10x10 10 10 3-1/4 15-1/2 14-1/4 DMPREC10x14 10 14 3-1/4 15-1/2 14-1/4 DMPREC10x18 10 18 3-1/4 15-1/2 14-1/4 DMPREC10x24 10 24 3-1/4 15-1/2 14-1/4 95400 1 2 5 8 1 2 13 3 8 1 5 8 10 1 8 C 4 1 4 6 1 2 4 PLCES ROMETRIC YPSS (In.) 95412 PRT NO. C DMPR08x14 8 14 15-1/4 DMPR08x24 8 24 25 5

Physical data Input Voltage Max Input Power Damper output torque mbient Temperatures Wire Connections Wire Connectors Stroke Time DMPCT 45 DEG DMPCT 90 DEG Travel Time arometric ypass Pressure Range 24 VC 5 va 15-20 in. - Lb 32 F / 0 C - 120 F/49 C Common, Open, Close Plated Screw Terminals For 14-22 WG ngular Rotation per Sec 3 per Sec 6 per Sec 15 Sec 0.4 1.2 in. w.c. 6

Damper pressure drop airflow data 400 FPM 600 FPM 800 FPM DESIGN UNIT MXIMUM DMPER In. In. In. (CFM) (CFM) DMPSL08X10 0.03 0.05 0.08 430 645 DMPSLS08X12 0.03 0.05 0.08 430 645 DMPSL08X12 0.03 0.05 0.08 520 780 DMPSLS08X12 0.03 0.05 0.08 520 780 DMPSL08X14 0.03 0.05 0.08 610 915 DMPSLS08X14 0.03 0.05 0.08 610 915 DMPSL08X16 0.03 0.05 0.08 700 1050 DMPSLS08X16 0.03 0.05 0.08 700 1050 DMPSL08X18 0.03 0.05 0.08 780 1170 DMPSLS08X18 0.03 0.05 0.08 780 1170 DMPSL08X20 0.03 0.05 0.08 870 1305 DMPSL08X22 0.03 0.05 0.08 960 1440 DMPSL08X24 0.03 0.05 0.08 1050 1575 DMPSL10X10 0.03 0.05 0.08 540 820 DMPSLS10X10 0.03 0.05 0.08 540 810 DMPSL10X12 0.03 0.05 0.08 650 975 DMPSLS10X12 0.03 0.05 0.08 650 975 DMPSL10X14 0.03 0.05 0.08 760 1140 DMPSLS10X14 0.03 0.05 0.08 760 1140 DMPSL10X16 0.03 0.05 0.08 870 1305 DMPSLS10X16 0.03 0.05 0.08 870 1305 DMPSL10X18 0.03 0.05 0.08 980 1470 DMPSLS10X18 0.03 0.05 0.08 980 1470 DMPSL10X20 0.03 0.04 0.06 1090 1635 DMPSL10X22 0.03 0.04 0.06 1200 1800 DMPSL10X24 0.03 0.04 0.06 1300 1950 DMPSL14X20 0.02 0.04 0.06 1530 2295 DMPRND06INC 0.02 0.04 0.06 120 180 DMPRND08INC 0.02 0.03 0.05 220 330 DMPRND10INC 0.02 0.03 0.04 490 735 DMPRND12INC 0.02 0.03 0.04 700 1050 DMPRND14INC 0.02 0.03 0.03 960 1440 DMPRND16INC 0.02 0.03 0.03 1250 1875 DMPREC08X10 0.02 0.03 0.04 500 750 DMPREC08X14 0.02 0.03 0.04 700 1050 DMPREC08X18 0.02 0.03 0.04 900 1350 DMPREC08X24 0.02 0.03 0.04 1200 1800 DMPREC10X10 0.02 0.02 0.02 620 930 DMPREC10X14 0.02 0.02 0.02 870 1305 DMPREC10X18 0.02 0.02 0.02 1120 1680 DMPREC10X24 0.02 0.02 0.02 1500 2250 NOTE: s the design airflow for dampers is exceeded, the potential for airflow noise problems increases. HOW TO USE PRESSURE DROP DT 1. Calculate airflow for each zone based on load and number of zones. 2. s duct system is designed, calculate pressure losses in each duct run and in the air handler (filter and cooling coil). 3. ased on the duct size and amount of airflow required in each zone, calculate a duct velocity for the air through the damper. 4. Use the chart to find the pressure drop for the damper and the calculated velocity in each duct run. 5. Put the damper pressure drop data into the duct losses for each run and calculate a total system pressure loss. 6. Make sure that the unit specified for the application will supply the required amount of air for the calculated system pressure loss. 7. Make sure that the maximum airflow for each damper is not exceeded. Example: House with 3.5 ton load 350 CFM / ton of air conditioning gives approximately 1200 CFM required. House is installing a 2-zone system. Therefore, 600 cfm is required in each zone. If 8-in. x 18-in. ducts are used in the house the duct area is 8-in. x 18-in. /(144 sq in. per sq ft) gives 1.0 sq. ft. of duct area. Dividing the airflow for each zone (600 CFM) by the duct area (1.0 sq ft) gives 600 fpm. DMPREC08X18: 0.03-in. DMPSLS08X18: 0.05-in. DMPSL08x18: 0.05-in. ottom mount slip-in dampers were chosen for this installation. Therefore 0.05-in. of pressure drop should be added to each duct run. 7

SERVICE TRINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: Unit Familiarization Maintenance Installation Overview Operating Sequence large selection of product, theory, and skills programs is available, using popular video-based formats and materials. ll include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. CLL FOR FREE CTLOG 1-800-962-9212 [ ] Packaged Service Training [ ] Classroom Service Training 94328 Carrier Corporation Syracuse, New York 13221 1-96 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. ook 1 1 1 4 4 4 Page 8 Catalog No. 92-32D-MP1C Printed in U.S.. PC 101 Form DMP-1PD Tab 3a 5 6 2a 5a 8a Replaces: New