Phase Technology PPA-70Xi Pour Point Analyzer

Similar documents
Phase Technology PFA-70Xi Pour & Freeze Point Analyzer

Phase Technology CPA-70Xi Cloud Point Analyzer

Vapor Pressure Measurement Of Gasoline, Crude Oil & LPG With New ASTM D5191 & D5188 Speed Test

breakthrough versatility

Stabinger Viscometer SVM 3001

MESA-7220 Multi-Element Analyzer Using EDXRF Technology

Thermo Scientific Hot Plates, Stirrers and Stirring Hot Plates

Elemental Analysis Advanced

Innovation in cold behavior

Callisto 100. Cold Filter Plugging Point Tester

Innovation in cold behavior

Process Analyzer. Flash Point Analyzer Model P-500. Credible Solutions for the Oil and Gas Industry

Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE

CHAIN WEAR ANALYSIS WITH LUBECON

Sulfur in Oil Analyzer

MiniLab EL Series for High Performance Engine Development and Maintenance

Monitor Chlorine in Crude at Sub-ppm Levels

ERAVAP NEW! VAPOR PRESSURE TESTING AT ITS BEST. One Vapor Pressure Tester for All Applications:

Instruments for the Analysis of Petroleum Products. Oxidation Stability

MESA-7220 Measurement of Sulfur, Chlorine and other elements in Petroleum Products Using Mono-chromatic, Polarized EDXRF Analysis

Low cost EDXRF elemental analyzer

Standard Test Method for Pour Point of Petroleum Products (Automatic Air Pressure Method) 1

Process Analyzer. Reid Vapor Pressure Analyzer Model P-700. Credible Solutions for the Oil and Gas Industry

ALL-TEST PRO 5. The AT5 Motor Circuit Analyzer Complete electric motor health analysis in minutes! Motor Circuit Analyzer

Process Analyzer. Viscosity Index Analyzer Model P-950. Credible Solutions for the Oil and Gas Industry

ADU 5. Automatic Distillation Unit

LABORATORY. Fuel additives technology.

Don't just Perform Service - Sell It!

Cetane ID 510. Customer Presentation. Refining. Petrochemical

Buildings. Product Name. THE SMART CHOICE FOR ENERGY SAVINGS. SmartVFD HVAC and BYPASS

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

A Guide to Dry Block Calibration

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic)

Electrical Dump Truck 980E-4

Model Name: 4 Position RPV-1

PH20 Value ph Tester Instruction Manual

Excellence Level. XPR Precision Balances Accurate, Flexible, Compliant. XPR Precision Balance Solutions Go Beyond Weighing

Determination of Phenolic Antioxidant DBPC and DBP Levels in Electrical Insulating Oil

Agilent 7693A Automated Liquid Sampler

TECHNOLOGY AND SIMPLICITY.

MoistureMatch A next generation grain tester

As diesel fuel ages it degrades in 2 ways: particulate formation, and biological growth.

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

ElvaX Sulfur in Oil analyzer

6109A / 7109A. Portable Calibration Baths. Four times more calibration throughput with twice the accuracy of Micro-Baths and dry-block calibrators

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic)

CFPP Process Analyzer

Glide Screw. Combines the Features of a Linear Bearing and Screw in One Compact Package

FORD MONDEO Quick Reference Guide

VAS 6230B Road Force Touch. Customized for All Audi, Bently, Seat, Skoda and Volkswagen Vehicles NEW!

Excellence Level. Excellence XSR Balances Discover Efficiency in Daily Weighing

Penetration. Test Methods

B/R Vacuum Distillation ASTM D1160. Fully Automatic Vacuum Distillation According to D1160

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

VERITY Purification Systems Build the perfect system to fit your research

Objective: Estimate and measure liquid volume in liters and milliliters using the vertical number line.

Smart Wi-Fi Sprinkler Timer and Flow Meters

Transforming the Battery Room with Lean Six Sigma

Addressing the API Licensing Fear Factor

ELD DRIVER GUIDE June 21, 2018

Analysis of Petroleum Samples Using the Teledyne Leeman Labs

Saving energy while increasing productivity Servo-hydraulic drive CSH. voith.com

4 Sensor Backup Obstacle Sensing System Model: ACAB104 Users Manual

Infinite F50 family INNOVATIVE EIGHT CHANNEL ABSORBANCE READERS WITH ADVANCED LED TECHNOLOGY. 21 CFR Part 11* 98/79/EC IVD-D*

THE INNOVATOR OF OUR INDUSTRY. SuperSprings.... They Simply Are the World s Finest Die Springs

PMA 5. Pensky-Martens Flash Point Tester. ::: Volatility... Flammability

June 25, 2013 # Model 464 Electronic Pump Control Unit User Guide

X-ray Essentials from XOS Proven Performance

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

USV Ultra Shear Viscometer

1. Measure the length of the track (already set up by your teacher) in meters and record in table 1. Use a meter stick for this.

2016 CIVIC PERSONALIZED SETTINGS CHART Color Audio models:

Q200. Aquamax FlashPoint. Q5800 MiniLab 53 MiniLab 153 MicroLab Q1000. Q100 Spectroil M. Q300/310 Q3000 Pat 940 Density 5

Stabinger Viscometer Series. SVM Series

Hot Runners and Temperature Controllers

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

ValveLink SNAP-ON Application

BMW K1200LT / K1200RS Testing a Throttle Position Sensor (also called TPS)

EDXRF APPLICATION NOTE SULFUR IN BUNKER FUEL # 1230

Physical Property Analyzer PPA4100 Series. On-Line RVP Analyzer

LIGHTER FASTER STRONGER

Table of Contents 1. INTRODUCTION GENERAL INFORMATION-ABOUT OBDII/EOBD PRODUCT DESCRIPTIONS OPERATIONS...11

Vehicle Use Case Task Force S3: Customer connects vehicle to premise using Premise EVSE that includes the charger

500/800. CalTrak. High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry. FEATURES DESCRIPTION

WAYNE FUSION FORECOURT SYSTEM. Meet the new face of. forecourt control.

Alberta Innovates - Technology Futures ~ Fuels & Lubricants

Vehicle years are now available starting in the 1910 s. To collapse the menu click on the Less link

RAPID OIL TEST GAUGE

January 10, 2017 # Rev. B. Model 464 Mk3 Electronic Pump Control Unit User Guide

RS-230-DP. Operation Guide

Shawal CGC Calibration Profile

Ultrafast GC Performance in the Real World: Multi Lab Studies for Repeatability & Reproducibility

Vehicle Use Case Task Force S2: Customer connects vehicle to premise using Premise EVSE

TESTING OF FUELS : FLASH AND FIRE POINT

Standard Test Method for Cold Filter Plugging Point of Diesel and Heating Fuels 1

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

Process Analyzer. Cold Filter Plugging Point Process Analyzer CFPP-4. Credible Solutions for the Oil and Gas Industry

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

PAGE Both power cords must be connected & powered to operate the E-TES SD 120 volt unit.

Transcription:

Phase Technology PPA-70Xi Pour Point Analyzer

About Phase Technology Expertise: Design & manufacture of analyzers to test cloud, pour and freeze point Cold Flow is All We Do! Scientific Background: 29 year history of research; 30 patents Market Leader: 20 years of inter-laboratory round robin research Phase ranks highest for repeatability, reproducibility, sensitivity and equivalency to reference manual test methods

Phase Technology customers

Why do more companies in the world choose Phase Technology analyzers?

Companies choose Phase Technology because: 1. World s best precision 2. World s fastest test speed 3. World s most complete set of features and easy-to-use analyzer

Phase Technology 70Xi

70Xi analyzer benefits Fastest speed of any automatic or manual method: Average test duration 8 30 min Average operator time 0.5 2 min Easy and fast to use saves time in the lab Reports at 3 C or 1 C intervals; capable of any user programmable resolution to 0.1 C Powerful cooling system; minimum sample temperature to below -88 C [-126 F]

70Xi productivity features Fast, one-touch testing press one button to run a test instead of entering multiple screens of information Full-color, touch-sensitive, 15 high resolution screen Easier to read and view more information Displays several views of information at the same time. Touch sensitive design is faster than keyboard & mouse. Easy-to-use interface New colorful graphic icon buttons for faster navigation. Intuitive and easy to understand on-screen prompts.

70Xi productivity features USB and Ethernet connectivity Quickly export analyzer data to a portable USB flash drive. Ethernet port available for connecting to LIMS or internal computer network Import and store any user documents (.doc,.pdf,.ppt and.pps) for customized operating procedures (SOP) or training Reliability improvements Modular component design boards can be easily replaced in the field; no need to return to Canada for service More stable cooler Faster multiprocessor

70Xi intellinostics Built-in answers and operator information Quick, responsive solutions built-in alert messages give troubleshooting options to quickly solve problems Self-guided tutorials easy, on-screen instructions show how to use analyzer In-depth system diagnostics system checks verify performance and detect problems with critical components

Phase Technology 70Xi Autosampler System

Automatic sampling & cleaning Set-and-forget convenience set 1 to 48 test runs, then walk away and let the analyzer do the rest! Automatic sample injection no need to individually pipette samples or change pipette tips. Always uses the exact amount of sample required by the ASTM method. Self-cleaning Saves time and ensures perfect cleaning every time. No more need for cotton swabs or risk of damage to sample cup.

70Xi home screen

70Xi Favorites feature One-touch preset Favorites Frequently-used test settings can be stored in the analyzer for quick access. Favorites can be created, organized, sorted or deleted as you desire. With the single push of a button, lab operators can efficiently perform tests in significantly less time

Built-in tools to validate test results Overlay and compare multiple phase plots Control and trend charts Automatic QC run Option to retest sample Optional alert or lockdown if out of acceptable limits

70Xi control chart consistent runs

70Xi control chart bad run

On-screen pour point phase plot

Understanding phase plots

Phase plot can tell you when there is a problem: example of possible moisture in sample

ASTM Methods Comparison

POUR POINT ASTM Method Comparison Phase Technology 70Xi ISL CPP 5Gs ISL MPP 5Gs Tanaka MPC-102 Manual Method ASTM Pour Point Method D5949 D5950 NONE (ASTM D7346 NO FLOW method has not been found to be equivalent to pour point) D6749 D97 Repeatability (@3 C) Reproducibility (@3 C) Test duration Temperature range 2.2 C 3.9 C N/A (no Pour Point Round Robin data) 3.8 C 6.1 C N/A (no Pour Point Round Robin data) 2.5 C 3 C 3.1 C 6 C 8 to 20 minutes 80 to140 minutes 30 to 75 minutes 45 to120 minutes 60-180+ minutes -88 C to +55 C -95 to +51ºC -95 C to +45 C -30 C to +51 C* -65 C to +51 C (external cooler) Varies depending on external bath Sample volume 0.15 ml 15 ml 0.5 ml 4.5 ml Aprox 11 ml External cooler or bath required no no no Yes* (*air cooled model available) yes

POUR POINT ASTM Method Comparison ISL/PAC CPP5Gs The CPP5GS is extremely slow and has poor precision uses a mechanical tilt method which takes 80 140 minutes to complete a pour point test Compare to Phase Technology pour point test takes 8 20 minutes ISL/PAC MPP5Gs The ISL MPP5Gs uses ASTM D7346 to determine the no flow point of petroleum products. ASTM stated that there is no correlation between no flow and pour point. ASTM D7346 no flow point cannot be used to certify lube oil products for release because it is not a pour point method. The only accepted standards for product release are pour point methods, such as ASTM D5949 (as used by Phase Technology 70Xi analyzers).

POUR POINT ASTM Method Comparison Tanaka MPC-102 Tanaka is the slowest automatic method reports of 90 120 minutes for low temperature lubes Phase Technology 70Xi can perform at least eight test runs in the time that it takes Tanaka to perform one single test! The MPC-102 requires 4 ml of sample (contrast to Phase Technology use of 0.15 ml). Larger sample volume introduces non-uniform temperature. Even with external liquid cooler, MPC-102 is not able to reach the low temperature level that Phase Technology does. Tanaka is only capable of going down to -30 C with internal cooler Phase Technology reaches -88 C with internal cooler

The Phase Technology ADVANTAGE: Phase Technology s 70Xi analyzer is 4 to 10 times faster than the competition! Phase Technology s 70Xi analyzer has the world s best precision The 70Xi requires much less sample: 4 to 14 ml less needed per test!

The Phase Technology ADVANTAGE: Phase Technology has the oldest, most established, continuous-in-production automatic cold flow ASTM Methods 17 years of proven, in-the-field use! The PSA-70Xi tests pour, cloud and freeze point in one single unit. You d have to buy two or three separate analyzers from our competitor!

Thank you! For more information: phase-technology.com