Project. Comments. Prepared by

Similar documents
Catalog # Project. Comments. Prepared by

Project. Comments. Prepared by

Sure-Lites LPXC SERIES. Input Voltage Input Power 19 3/4" " /8" /8" 54 13" /2" 191

PathLinx Series LED Emergency Lighting

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

Fixed Head Emergency Lights

For complete photometric data, refer to the back cover of this brochure.

Spectron Industrial Series

Self-Testing Industrial Series

CODE MANDATED INTERIOR EMERGENCY LIGHTING:

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Industrial LED luminaires Exit and Emergency

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

SAVE THESE INSTRUCTIONS

MIRRORLITE RECESSED EMERGENCY LIGHTING

UL AND CODE COMPLIANCE

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Encounter Metric Recessed LED Luminaire

FHSCP-UNV-10P-L-SD INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

AUTHENTIC LIFE SAFETY PRODUCTS SINCE 1940

Installation Instructions Central Battery Units

GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

FAZE180 FAZE180

The HP Series offers many advantages in an industrial environment

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

High-Performance Industrial Emergency LED Lighting LHP & LHPR SERIES

LED Black Housing High Output Remote Capable

Metalux SNLED LENSED LED

Bavaria Downs. Chaska, MN. Lighting

DeSoto EMERGENCY LIGHTING UNIT. U.S. Versions: 12V- DM (P2 & P3) / DM / DM INSTALLATION INSTRUCTIONS

EMIU 720W Mini Inverter

Taxonomies, Classifications, and Categories LED FLOODLIGHTS, WALLPACKS, BOLLARDS & LANDSCAPE LIGHTING

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Prestige Series Edge-Lit LED Sign IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

To The. We ve Taken Exit Signs. Elegant Styling Industry-Leading Quality And Performance Easy, Trouble-Free Installation

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS

FHSCP-UNV-10P-L-SD SPECIFICATIONS

Encounter Recessed LED luminaire

Metalux SNLED LENSED LED

New York City Approved. emergency lighting

RF80-K Aircraft Battery Charger / Analyzer

Cat# DC LED Array Emergency Driver

Cruze Recessed LED Luminaire

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

Catalog # Project. Comments. Prepared by. 11" [279mm] 8-3/4" [222mm] ESCUTCHEON PLATES. 2-5/8" [67mm] 3/4" [19mm] Dia. Hole. 3" [77mm] 1-1/2" [39mm]

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

Exit and Emergency Lighting Products PRODUCT CATALOG

Explosion Proof Emergency Exit Sign - 90 Minutes Battery Backup - 120/277V - Emergency Lighting Syst

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

Photoelectric Sensors 55 Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

VERSYS Architectural Recessed T5 Fluorescent

HBLEDLD524SEWUNV Hbledld524sewunvl850ed2u

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

SeleCCTable LED Direct Mount Collection

Echo Shapes 9.0 LED. EEW in DESCRIPTION FEATURES & BENEFITS SPECIFICATIONS PROJECT DETAILS JOB NAME: TYPE: NOTES:

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

Installation Instructions

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

Beam lights & conversion kits

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

INTRODUCING THE NEW MINI INVERTERS BY READY-LITE

Luminous HE 282/284 Direct ambient lighting. Neoray. Possibilities of Light

Project. Comments. Prepared by

Sola/Hevi-Duty S3K Series Mini-Tower UPS

SkyBar TM Series High Bay LED Luminaire

eshine Flood Lamps Technical Data

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS!

Metalux 22EN LED. Warranty Five year warranty. Specification Grade Troffer. Driver Access Drivers can be accessed via plenum.

Induction Compact Fluorescent HID LPQ. Canopy Luminaire

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

LED EXIT SIGN WITH REMOTE CApability

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

Table of Contents. Accessories Faceplates Polycarbonate Shields...46 Wire Guards... 47

SeleCCTable LED Direct Mount Collection. RL Recessed Downlight. Direct Mount

L Listed FEATURES. Series Lamps Wattage # of Lamps ICR= remote fixture 7= 7.2 watts. L Listed. Phantom TM FEATURES

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

NLP LED 15 E V NLP LED 25 E V. Drivers. Drivers

2018 LED Downlight Series

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS...

Cruze Recessed LED luminaire

Micro Lighting Inverter

The Noah Emergency Lighting Wet Location Family RMRN PRMRN SWN SLBN

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

Transcription:

DESCRIPTION The Sure-Lites Emergency Light (SEL) series is designed to reduce egress system cost and maintenance as well as improve reliability. Key features include long life LED s, proprietary adjustable acculed optics, a nickel cadmium battery and an Eagle Eye self-diagnostics option. The Patented external battery disconnect and easy hang features reduce installation time and cost. Catalog # Project Comments Prepared by Sure-Lites Type Date SPECIFICATION FEATURES ELECTRICAL - Dual Voltage Input 20/277 VAC, 60Hz - 240 VAC capable with 48 hour recharge time - External Battery Disconnect - Brownout circuit - Low voltage disconnect - Overload / Short Circuit protection - 4.8V Battery back-up - Eagle Eye self diagnostic option - Laser test capability (self-diagnostic option) HOW TO SPECIFY Sure-lites LED emergency light with nickel cadmium battery, external battery disconnect, and adjustable optics. DIMENSIONS /SD//SD HOUSING CONSTRUCTION - Components injection molded, color stable, high impact thermoplastic - White or black textured finish - Black only available with self diagnostic - EZ Hang feature facilitates fast installation - Suitable for ceiling, pendant or wall mount applications - Universal J-box mounting pattern - Keyhole mounting slots - Aesthetically designed with thin profile BATTERY - Sealed Nickel Cadmium - Full Recharge Time, 24 hours (max.) - 0 to 40 C (32 to 04 F) WARRANTY - Five-year warranty - Prorated 7-year battery warranty CODE COMPLIANCE - UL924 Listed - Damp Location - Life Safety NFPA 0 - NEC/OSHA - Most State & Local Codes / / SEL Emergency Light LED Emergency Light Adjustable Optic Eagle Eye Self Diagnostics SEL Remote Capacity 4" [356mm] 2-7/8" [326mm] -3/4" [45mm] 4-3/4" [2mm] R0/R7/R4 4 3/4" [2mm] 4" [357mm] 3" [330mm] 3 /8" [80mm] TD505005EN /2/206

CATALOG LOGIC FOR NON-REMOTE CAPABLE VERSIONS SAMPLE NUMBER:, Series Coverage Battery Color Self Diagnostic SEL = LED Emergency Light 25 = 25 feet 50 = 50 feet = NiCad = White = No SD Series Coverage Battery Color Self Diagnostic SEL = LED Emergency Light 25 = 25 feet 50 = 50 feet = NiCad BK = Black CATALOG LOGIC FOR REMOTE CAPABLE VERSIONS SAMPLE NUMBER: R0, R7, R4 Series Spacing Battery Remote Capacity Color Self Diagnostic Full Catalog Options SEL = LED Emergency Light 25 = 25 feet = NiCad R0 = 0 watts = White BK = Black (standard) R0SD R0BKSD SEL = LED Emergency Light 50 = 50 feet = NiCad R7 = 7 watts = White BK = Black (standard) R7SD R7BKSD SEL = LED Emergency Light 60 = 60 feet = NiCad R4 = 4 watts = White = No SD R4 R4SD SEL = LED Emergency Light 60 = 60 feet = NiCad R4 = 4 watts BK = Black (standard) R4BKSD ELECTRICAL CHARACTERISTICS DURING CHARGING MODE // 20 volt 277 volt Model Power (W) Current (A) PF Power (W) Current (A) PF 0.6 0.07 0.06 0.64 0.07 0.03 SD 0.6 0.07 0.07 0.67 0.07.0 05 0.05.02 04 SD.2 05 0.06 9 04 R4.7 0.25 0.06.62 0.2 R4SD 2 0.3 0.07.8 0.2 R0SD 2 0.3 0.07.8 0.2 R7SD 2 0.3 0.07.8 0.2

REMOTE SYSTEM DESIGN GUIDELINES // SEL Series Remote Wattage Consumption Single Head Remotes Double Head Remotes Catalog Number SRP3/SRM3 SRP25/SRM25 SRP30/SRM30 SRP25D/SRM25D SRP50D/SRM50D SRP60D/SRM60D Watts Consumed.25 2.5 4 2.5 5 8.2 SEL Series Remote Capacity Catalog Number Remote Watts Available # of SRP3/ SRM3 Remotes Fixture Will Power # of SRP25/ SRM25 Remotes Fixture Will Power # of SRP30/ SRM30 Remotes Fixture Will Power # of SRP25D/ SRM25D # of SRP50D/ SRM50D # of SRP60D/ SRM60D R0SD 0 8 4 2 4 2 R0BKSD 0 8 4 2 4 2 R7SD 7 5 2 2 NA R7BKSD 7 5 2 2 NA R4 4 3 NA NA NA R4SD 4 3 NA NA NA R4BKSD 4 3 NA NA NA LEM Series Remote Wattage Consumption Single Head Remotes Double Head Remotes Catalog Number LEMR LEMWR LEMR2 LEMWR2 Watts Consumed.4.4 2.8 2.8 LEM Series Remote Capacity Catalog Number Remote Watts Available # of LEMR # of LEMWR # of LEMR2 # of LEMWR2 R0SD 0 7 7 3 3 R0BKSD 0 7 7 3 3 R7SD 7 5 5 2 2 R7BKSD 7 5 5 2 2 R4 4 2 2 R4SD 4 2 2 R4BKSD 4 2 2

.2 0.7 0.4 0.2 0.2 0.2 0.2 0.3 0.5 0.9.3.4 0.9 0.9.3.4.0 0.6 0.3 0.2 0.2 0.2 0.2 0.3 0.6.0.4.3 0.9 0.9.0.4.3 0.8 0.5 0.3 0.2 0.2.8 0.9 0.4 0.2 0.2 0.2 0.2 0.3 0.6.2 2 2.6.9.2.6 2.5 2.3.5 0.7 0.4 0.2 0.2 0.2 0.2 0.4 0.7.5 2.3 2.5.6.2.9 2.6 2.2 0.6 0.3 0.2 0.2.8 0.8 0.4 0.2 0.2 0.2 0.2 0.3 0.5 2.2 2.9 2.4.7 2.8 2.5.4 0.7 0.3 0.2 0.2 0.2 0.2 0.3 0.7.4 2.5 2.8.7.4 2 2.9 2.2 0.5 0.3 0.2 0.2 0.9.3.9 2.3 2.6 0.7 0.4 0.3 0.2 0 0 0 0 0 0 0 0 0 0 0 0 0.2 0.3 0.4 0.7.6 2 2.3.9.3 0.9.2 2.0 3.0 3.5 3.0 2.0.2 0.7 0.5 0.3 0.2 0 0 0 0 0 0 0 0 0 0 0 0 0.2 0.3 0.5 0.7.2 2.0 2.9 3.5 3.0 2.0.2.7.3 2.2 3.3 3.7 3.0.9.2 0.7 0.4 0.3 0.2 0 0 0 0 0 0 0 0 0 0 0 0 0.2 0.3 0.4 0.7.2.9 3.0 3.7 3.3 2.2.3.8.2 Sure-Lites PHOTOMETRY 4 5 6 7 8 9 0 25ft X Y Z Orient Tilt -0.5 0.25 7.5 25 27 0.5 0.25 7.5 55 27 6.5 0.2 7.5 25 27 7.5 0.22 7.5 55 27 33.5 072 7.5 25 27 25 ft. 34.5 073 7.5 55 27 50.5 032 7.5 25 27 5.5 035 7.5 55 27 67.5 0.093 7.5 25 27 68.5 0.096 7.5 55 27 84.5 0.054 7.5 25 27 85.5 0.058 7.5 55 27 0.5 0.05 7.5 25 27 02.5 0.09 7.5 55 27 2 4 3 50ft 50 ft. X Y Z Orient Tilt 24.25 0.33 7.5 58 40 24.75 0.33 7.5 22 40 74.75 0.3 7.5 22 40 74.25 0.292 7.5 58 40 ***The Rule of Thumb spacing guidelines are designed to achieve foot-candle average and 0 foot-candle minimum with a 40: maximum/minimum ratio. The corridor used is 00 feet long, 9 foot ceiling with a 6 foot wide walkway and 3 foot path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.5 feet. Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance.

0.2 0.2 0 0 0 0 0.2 0.2 0.2 0.3 0.4 0.5 0.7.0.5.9 2.0.8.6.4.0 0.6 0.5 0.5 0.5 0.5 0.8.3.5.7.9.9.6.2 0.8 0.6 0.4 0.3 0.2 0.2 0.2 0.2 0 0 0 0.2 0.2 0 0 0 0 0.2 0.2 0.2 0.3 0.4 0.5 0.8.3 2.2 3.2 3.9 3.5 2.5 2.5 0.8 0.6 0.6 0.7 0.7.3.9 2.3 3.2 3.9 3.5 2.5.6.0 0.6 0.4 0.3 0.2 0.2 0.2 0.2 0 0 0 0.2 0 0 0 0 0 0.2 0.2 0.2 0.3 0.4 0.5 0.7.8 2.9 3.8 3.7 2.8 2.4.8.0 0.7 0.7 0.8 0.8.6 2.2 2.6 3.5 3.9 3.2 2.2.3 0.8 0.6 0.4 0.3 0.2 0.2 0.2 0 0 0 0 Sure-Lites PHOTOMETRY 2 78 60ft 43 09 60 ft. X Y Z Orient Tilt -0.25 0.5 7.5 70 57 0.25 0.5 7.5 0 57 20.25 0.5 7.5 0 57 9.75 0.5 7.5 70 57 59.75 0.5 7.5 70 57 60.25 0.5 7.5 0 57 80.25 0.5 7.5 0 57 79.75 0.5 7.5 70 57 ***The Rule of Thumb spacing guidelines are designed to achieve foot-candle average and 0 foot-candle minimum with a 40: maximum/minimum ratio. The corridor used is 00 feet long, 9 foot ceiling with a 6 foot wide walkway and 3 foot path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.5 feet. Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance.

TECHNICAL DATA Mechanical Housing All components are injection molded with a color stable, high impact thermoplastic resin. The surface is textured to improve aesthetic appearance. The housing construction is designed with snap-fit components and reinforcement ribs to provide maximum strength at minimum installation effort. The mounting hole pattern is universal to junction box requirements and is suitable for both wall and ceiling mount applications. EZ Key External Power Disconnect Prevents the battery from cycling during the construction phase and ensures battery is not drained from power cycling. EZ Hang Mounting Feature The hands-free EZ Hang feature allows the installer to hang the emergency light face from the back plate in order to easily and efficiently make the power connections. Eagle Eye Self Diagnostics The Eagle Eye self-diagnostic software will automatically perform all tests required by UL924, and NFPA0and will systematically calibrate itself in the field; thus reducing installation labor and eliminating manual calibration errors. The system indicates the status of the emergency light at all times using the LED indicator. A 90 minute battery power (emergency mode) simulation test will occur once every 2 months. A 30 second battery power simulation test will occur every 30 days. The Solid-State microprocessor based system has the ability to accurately detect and warn of system failures, plus it incorporates all of the standard electronic features that sets Sure-Lites apart from its competition. Low Voltage Disconnect The low-voltage circuitry disconnects the lighting load to protect the battery after run times in excess of the 90-minute UL limit. The disconnect remains in effect until normal utility power is restored preventing deep battery discharge. Brownout Circuit The brownout circuit on the SEL emergency light monitors the flow of AC current to the unit and activates the emergency light heads when a predetermined reduction of AC power occurs. Warranty SEL units are backed by a five-year warranty on the fixtures. EZ Key EZ Hang SELF DIAGNOSTIC TESTING OPERATIONS The Sure-Lites Eagle Eye Self Diagnostics is continuously monitoring your emergency fixture, and will signal any failure through the 3 color indicator LED. Initial Operation: When the unit is first powered up it will go into a 24 hour fast charge and the indicator LED will pulse green. Once the unit has fully charged it will perform a self calibration. After self calibration, the LED will change to steady green indicating the unit is fully charged and float charging the battery to maintain readiness. Automatic Testing: The unit will perform a battery capacity, lamp/led, and charge circuit test every 30 days for 30 seconds. During this time, the indicator LED will change to a steady yellow. It will perform a full battery capacity (90 minute) test once per year. During this time, the indicator LED will change to a blinking yellow. Manual Testing: 0 Second Installation test Press and release the test button once during fast charge (blinking green) to initiate a 0 second quick test. The sign will switch to emergency mode for 0 seconds allowing the installer to verify proper installation of the unit, and the LED indicator will turn solid yellow. 30 Second Test - Press and release the test button once during float charge (steady green). The indicator LED will turn steady yellow to indicate the unit is performing a 30 second test of the batteries and lamps/leds. 90 Minute Test - Press and release the test button a second time during a 30 second test (steady yellow) to change to a 90 minute test. During this test, the LED indicator will change to blinking yellow, and the circuit will perform a full battery capacity, charge circuit, and LED test. Canceling Test Press and release the test button during the 90 minute test (flashing yellow) to return the fixture to its original state (fast charge or float charge) Laser Test: The SEL SD products are equipped with a Laser Test function that allows the unit to be manually tested without the need to physically press the test button. Shining a laser pointer in the hole marked LASER TEST on the bottom of the unit has the same effect as a press and release of the test button. Clearing Failure Codes: A battery failure (LED two blink red) can be cleared by replacing the battery. Disconnecting the battery and AC power, or performing a full 90 minute discharge will reset the error code, however, it will return if the battery is faulty Charge Circuit (LED three blink red) and lamp/led failure (LED four blink red) will clear when the unit successfully passes a manual or automatic 30 second test.

SELF DIAGNOSTIC TESTING OPERATIONS Indicators: LED Off - No power to unit, emergency mode. LED Steady Green - Unit is fully charged and is float charging the battery to maintain readiness. LED Green Pulse - Unit is in a 24 hour fast charge of the battery. LED Two Blink Red - Battery has failed a capacity test, or the battery is disconnected. See Clearing Failure Codes above. LED Three Blink Red - Battery charge circuit has failed. See Clearing Failure Codes above. LED Four Blink Red - Lamps have burned out, or on an EXIT/Combo, 50% or more of the LEDs have failed. See Clearing Failure Codes above. LED Steady Yellow - 30 second test or 0 second quick test (Fast Charge only). LED Blinking Yellow - 90 minute test. Maintenance: None required. Replace the batteries as needed according to ambient conditions. However, we recommend that the equipment be tested regularly in accordance with local codes. SURE-LITES OFF - EMERGENCY MODE / POWER OFF STEADY BLINK GREEN - FAST CHARGE STEADY GREEN - FULL / FLOAT CHARGE STEADY YELLOW - QUICK TEST STEADY BLINK YELLOW - 90 MINUTE TEST 2 BLINK RED - BATTERY FAILURE 3 BLINK RED - CHARGE CIRCUIT FAILURE 4 BLINK RED - LAMP/ LED FAILURE Eaton 2 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice.