SE-P8-6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HR 59 General partner Elektrobau Mulfingen GmbH Headquarters Mulfingen County court Stuttgart HRB 59 Nominal data Type Motor SE-P8-6 ME68-DF Phase ~ ~ Nominal voltage VC Frequency Hz 5 6 Type of data definition fa fa Valid for approval / standard CE CE Speed min - 9 6 Power input W Current draw.57.6 Motor capacitor µf Capacitor voltage VDB Max. back pressure Pa 9 Min. ambient temperature C -5-5 Max. ambient temperature C Starting current.. ml = Max. load me = Max. efficiency fa = Running at free air cs = Customer specs cu = Customer unit Subject to alterations Data according to ErP directive Installation category Efficiency category Static Variable speed drive No Specific ratio *. * Specific ratio = + p fs / Pa ctual Request Request 5 Overall efficiency η es.7. 8. Efficiency grade N 6.6 6 Power input P e kw. ir flow q v m³/h 95 Pressure increase p fs Pa 6 Speed n min - 5 Data definition with optimum efficiency. The ErP data is determined using a motor-impeller combination in a standardised measurement configuration. Item no. 59-5-998 Revision 788 Release -5-7 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com
SE-P8-6 Technical features Mass Size Surface of rotor Material of terminal box Material of blades Material of guard grille Number of blades 5 Direction of air flow Direction of rotation. kg mm Coated in black BS plastic Sheet steel, coated in black Steel, coated in black plastic (RL95) "V" Counter-clockwise, seen on rotor Type of protection IP ; Depending on installation and position as per EN 6-5 Insulation class "B" Humidity class F- Max. permissible ambient motor temp. (transp./ storage) Min. permissible ambient motor temp. (transp./storage) Mounting position Condensate discharge holes Operation mode Motor bearing Touch current acc. IEC 699 (measuring network Fig., TN system) Electrical leads Motor protection Cable exit Protection class Product conforming to standard pproval + 8 C - C Shaft horizontal or rotor on bottom; rotor on top on request Rotor-side S Ball bearing <. m Via terminal box, integrated capacitor connected via terminal box Thermal overload protector (TOP) wired internally xial I (if protective earth is connected by customer) EN 65-; CE GOST Item no. 59-5-998 Revision 788 Release -5-7 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com
SE-P8-6 Product drawing Direction of air flow "V" Tightening torque.5±. Nm Cable diameter: max. 7.5 mm, tightening torque. ±. Nm Connection screen L = U = blue Z brown N = U = black PE green/yellow Item no. 59-5-998 Revision 788 Release -5-7 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com
SE-P8-6 Charts: ir flow 5 Hz Druck p f s[pa]für Rho=,kg/m^ 6 55 5 5 5 5 5 5 95 9 85 8 7 65 6 55 5 5 5 5 5 5 6 8 qv[cfm] 6 8....6.8,6,6,6,58,56,5,5,5,8,6,,,,8,....6.8....6.8.. qv[m^/h],6,,,,8,6,,,,8,6,,,,8,6, pfs_e[in HO] Measurement: LU-9 ir performance measured as per ISO 58 Installation category. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: Lw measured as per ISO 7 / Lp measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. Measured values U V f Hz 5 5 5 5 n min - 9 55 P e W I.57.58.6.6 qv m /h 85 55 55 695 p fs Pa 5 5 7 U = Supply voltage f = Frequency n = Speed P e = Power input I = Current draw qv = ir flow p fs = Pressure increase Item no. 59-5-998 Revision 788 Release -5-7 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com
SE-P8-6 Charts: ir flow 6 Hz Druck p f s[pa]für Rho=,kg/m^ 6 8 qv[cfm]....6.8.,5 5,5,8 5 5 95 9 85 8 7 65 6 55 5,6,,,,8,6,,,,8,6,,, pfs_e[in HO] Measurement: LU-9 ir performance measured as per ISO 58 Installation category. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: Lw measured as per ISO 7 / Lp measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 5,8,6 5, 5,,,8 5,6, 5 5..5. qv[m^/h].5.,.5 Measured values U V f Hz 6 6 6 6 n min - 6 5 5 7 P e W 5 6 79 I.6.65.7.78 qv m /h 5 955 6 85 p fs Pa 5 5 U = Supply voltage f = Frequency n = Speed P e = Power input I = Current draw qv = ir flow p fs = Pressure increase Item no. 59-5-998 Revision 788 Release -5-7 Page 5 / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 () 798 8- Fax +9 () 798 8- info@de.ebmpapst.com www.ebmpapst.com