DetCon20. DetCon20. Detonation Control System MOTORTECH DETONATION CONTROL SYSTEM

Similar documents
MIC4 IGNITION CONTROLLER

WAUKESHA VHP P9390 GL

VariStep3 MOTORTECH Stepper Motor Driver Control

MOTORTECH Throttle Bodies For WAUKESHA VHP G/ GSI/ LT 6 & 12 Cylinder Engines

Ignition Controllers MIC3 MIC4 MIC5 MOTORTECH. MIC Series. reliable efficient worldwide MOTORTECH IGNITION CONTROLLER MOTORTECH IGNITION CONTROLLER

APPLICATION GUIDE For CATERPILLAR G3500 Series

IGNITION TOOLS & TEST EQUIPMENT

MIC4-ZS Ignition Controller For MWM /DEUTZ Gas Engines with TEM-ZS1 and TEM-ZS3 Ignition Systems

Integral Ignition Coils For Shielded Applications

Ignition Coils. Ignition Coils. For CATERPILLAR Gas Engines G3400, G3500, G3600 & GCM34 Series. reliable efficient worldwide

Compact Product Guide

APPLICATION GUIDE For CATERPILLAR G3400 Series

MOTORTECH. Ignition Controllers. MIC Series. reliable efficient worldwide

VariFuel2/VariFuel2+ MOTORTECH Air/Gas Mixer. VariFuel2 MOTORTECH AIR/GAS MIXER

SCOPELITE TIMING LIGHT OPERATING MANUAL

DETCON DETONATION CONTROL SYSTEM OPERATING MANUAL

DETCON DETONATION CONTROL SYSTEM OPERATING MANUAL

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

COMPACT PRODUCT GUIDE High Quality Parts and Accessories for Gas Engines

Catalysts For Efficient and Reliable Emission Reduction

SPARK PLUG CLEANING KIT OPERATING MANUAL

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

APPLICATION GUIDE For WAUKESHA VHP Series

APPLICATION GUIDE For MWM /DEUTZ Gas Engines

MOTORTECH Training Offer The Key to your Success!

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

True Fail-Safe Technology and Precision Control for Reliable Shutdown

Sensors & Controls. Everything you wanted to know about gas engine ignition technology but were too afraid to ask.

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MIC4 IGNITION CONTROLLER OPERATING MANUAL

Technical specification

CPU-95EVS Enhanced VariSpark Digital Ignition System for Industrial Engines

SET-UP TWO STROKE - presentation. SET-UP TWO STROKE - data entry

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Baker PPX Power Packs

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

CCM Gas Engine control

SECTION 2.10 IGNITION SYSTEM DESCRIPTION CEC IGNITION MODULE SYSTEM MAGNETO IGNITION SYSTEM

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Decision-Makerr Paralleling System

MIC5 IGNITION CONTROLLER OPERATING MANUAL

User Manual Solar Charge Controller 3KW

Transforming Transforming Advanced transformer control and monitoring with TEC

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

Delomatic 400 (DM 400) based Gas Engine and Combined Heat and Power (CHP) Control and Management System

Online data sheet GMS800 FIDOR EXTRACTIVE GAS ANALYZERS

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Section 3 Technical Information

Begin to Use The New ESC: Before use the new ESC please carefully check every connections are correct or not. Yellow motor wire B Blue motor wire A

Power Connect RX50. Series. Specification sheet. Features and benefits. Weight, size and sound level

din rail mounted active tracking filters with surge protection Product Guide DIN RAIL MOUNTED INDUSTRIAL DC UPS Product Guide

CPU-95 ADVANCED DIGITAL IGNITION SYSTEM FOR INDUSTRIAL ENGINES

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer

Smart Products. Maxon Workshop Richard Reyes

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

PowerCommand 3300 Control Panel. Our Energy Is Working For You.

Optidew Vision Optical Dew-Point Meter

Crane and Hoist Solution Guide. The Advantage of Experience

Power Connect TM Series RX60

ABB DRIVES SERVICE. Optimize your wind economy. Wind Converter Services

DIN RAIL MOUNTED INDUSTRIAL DC UPS OPTIMIZING UPTIME.

Cannondale Diagnostic Tool Manual

2033A Series. Where Reliability Breeds Confidence UNINTERRUPTIBLE POWER SUPPLY SYSTEMS ISO 9001 CERTIFIED

Original Operating Manual

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

GEAR UNITS IN FOCUS. PROCESSES UNDER CONTROL.

User Manual. Solar Charge Controller 3KW

User s Manual. Wind/Solar Hybrid Street Light Controller. Please Read This User Manual Carefully Prior to. Installation and Operation of This Product.

30 KW / 40 KVA POWERED by

The new generation of Brake Testers and Test Lanes: Safe and precise testing. For passenger cars and light commercial vehicles

Aurora Wind Interface Box

Cosmetic sealing. paint shop. Atlas Copco s SCA product line provides high-quality cosmetic sealing solutions

CPU-XL VariSpark ADVANCED DIGITAL IGNITION SYSTEM FOR LARGE GAS ENGINES

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

SENTRY ISOBUS Tip Flow Monitor. Software Version 1.00

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

PowerCommand 1.1 control system

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

BMS16. Thanks for your purchasing the BMS16 for your vehicle.

Power Rating Minimum Rating 116 bkw 156 bhp Maximum Rating 205 bkw 275 bhp. 105 mm (4.1 in) 135 mm (5.3 in)

Kelly KDHA High Voltage Series/PM Motor Controller User s Manual

Jet Fuel Conductivity Analysers & Additive Management systems

GE Oil & Gas. High-speed solutions. World-class HSR compressors and the worldwide service capabilities to support them

Skilmatic SI 3 3 Electric Fail-Safe Actuators

Spark-ignited generator set

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4

Kelly KDC Series/PM Motor Controller User s Manual

EG DYNAMIC user manual

Secondary DC Distribution

596 Rectifier Retrofit

Flash Point Process Analyzer

2015 PSI 8.8L LPG Engine Overview. Study Guide. Course Code: 8777

Combustion Monitoring with Pressure Sensors.

Customer Service. Enjoy 24/7 peace of mind with flexible service offerings from Schneider Electric.

Compliance, Performance, Support

No one comes close to matching the 20:1 and 15:1 turndown of our condensing Benchmark boilers.

NterpriseIP Solution Adaptive, high-availability power system for IP Telephony. Business-Critical Continuity for Communications

DTI Guardian Safety System with Intel-a-Valve Technology

Transcription:

DetCon20 Detonation Control System DetCon20 MOTORTECH DETONATION CONTROL SYSTEM Try the alternative. Call the nearest MOTORTECH sales partner for more information. REV.10/2013

DetCon20 MOTORTECH DETONATION CONTROL SYSTEM DetCon20 Detonation Control System The gas engine operators are calling for increased power output from their engines. More load means higher temperatures, pressures and tougher operation. This mostly ends in catastrophic engine damages due to detonation or pre-ignition. As MOTORTECH has proven for years, detonation can be detected professionally with the DetCon20 detonation control system. Single cylinder sensors constantly monitor the sound level of the combustion. If detonation is detected the system will take steps to eliminate detonation immediately. Upgrade your engine and increase availability of the equipment! Technical Data & Features Prevents the engine from damages caused by knocking combustion Can analyze two-stroke and four-stroke engines with up to 20 cylinders Frequency range knock sensors: 1-20 khz Easy Installation and configuration via USB interface DenEdit software for visualization and adjustment of firing sequences, actual knocking values or knocking history with long-term data Available as a built-in device for a switch cabinet or in a CSA-certified housing. DIN rail mounting Supply voltage: 9 36 VDC Can also be used on dual fuel and bi-fuel engines Interfaces USB 1.1 interface CAN Bus interface Scope of Supply DetCon detonation control system CD-ROM with software for configuring the device USB interface cable for connecting the device to a PC/laptop Operating manual Mounting kit (model with housing) Recommended Accessories AlphaRail wiring rails for easy installation PowerView3 for complete visualization of detonation data 2

Functional description Regular Combustion Figure 1 shows the desired combustion process of the gas/ air mixture within the combustion chamber. The gas/ air mixture is ignited by the ignition spark. The flame front spreads out evenly with the specific laminar flame speed of the gas/ air mixture. During the combustion, the cylinder pressure increases moderately. Knocking Combustion A knocking combustion is the result of a self-ignition of the gas/ air mixture prior to the actual flame front 2. The main reason for pre-ignition is an uncontrolled increase in pressure and temperature caused by the pressure and temperature fronts, which move faster than the regular flame front. The pressure and temperature fronts caused by self-ignition can cause further self-ignitions. Inside the combustion chamber high frequency shock waves arise. They are transferred from the combustion chamber to the engine structure and given off to the environment as airborne sound. This makes the knocking audible 3 5. Compared to regular combustion the knocking combustion results in significantly higher peak pressure. In addition to a higher thermal load this might also lead to a damaged engine. DetCon20 Detonation Control System The geometry of the combustion chamber leads to enginespecific sounds of knocking combustion. The DetCon20 detonation control system measures the frequency spectrum of each power cycle with structure-borne sound sensors and compares it with engine specific parameters. If knocking is detected in a cylinder s power cycle, the Det- Con20 detonation control system attempts to stop knocking by setting a later ignition timing. If knocking is no longer detected, the ignition is set back to an early timing. If stronger knocking is detected or the retarded timing has no effect, the signal for load reduction is sent to a superior engine controller. The signal for engine shutdown is sent to the superior engine controller when the load reduction is unable to stop the knocking. The result is a reliable protection of the engine against damages caused by knocking combustion. 3

System Overview ALL-IN-ONE MOTORTECH GAS ENGINE MANAGEMENT PowerView3 MOTORTECH ENGINE INFORMATION MONITOR MIC4 MOTORTECH IGNITION CONTROLLER D C A E USB CAN Ignition Timing Control (0-5 VDC / 4-20 ma) Power supply 9-36 VDC B Binary outputs Alarm Load reduction Engine stop 2 1 USB CAN DetCon20 MOTORTECH DETONATION CONTROL SYSTEM 3 Required Accessories 1 DetCon20 2 Knock sensor wiring 3 Knock sensor Accessories A Ignition controller B Wiring rail (ignition) C PowerView3* D ALL-IN-ONE* E Laptop * Visualization via MOTORTECH PowerView3, alternatively with MOTORTECH ALL-IN-ONE 4

Software DenEdit DetCon Software You can configure the DetCon device to display the current knocking values of the engine and determine the values off-line using the DenEdit software application. Actual knocking value In this example the current knocking values for every cylinder are shown. The background color indicates the set limits (yellow area ignition timing adjustment -> load reduction, red area engine shut-down). Knocking history This screen gives an overview of all sensor activity during the last minute. It is possible to display individual cylinders or, as seen in the diagram, all cylinders. This makes it easy to analyze deviations. Timing sequences This menu provides the option to enter a freely definable firing sequence. 5

Mechanical Data Property Dimensions of the device (incl. DIN rail clamps) Value DetCon20 160 x 187 x 52 mm (6.3 x 7.37 x 2.05 ) Model with enclosure 400 x 300 x 125 mm (15.75 x 11.81 x 4.92 ) (length x width x height) Mounting the electric unit Weight DIN rail mounting 0,74 kg (1.63 lbs) Protection class Protection class: IP 20 Environmental conditions Operation -10 C to 60 C max. (14 F to 140 F) Storage -40 C to 70 C max. (-40 F to 158 F) max. 95% humidity without condensation Accessories Knock Sensors Can be installed on any cylinder head bolt or stud. Measures the combustion signal and transfers it to the controller. ISU Ignition Sensor Unit When used with ignition controllers that are not part of the MIC3/ MIC4/ MIC5/ MIC850 series, an additional ignition impulse sensor is required. 6

Accessories PowerView3 MOTORTECH ENGINE INFORMATION MONITOR PowerView3 HMI Module The operating data of DetCon20 Detonation Control System is completely visualized by the HMI module (Human Machine Interface). The overview screen shows the relevant information such as engine knocking, knock intensity and status for activated load reduction or emergency shutdown of the engine. The control buttons guarantee easy navigation through different display pages and menus. Thus, the PowerView3 HMI module is also able to provide error diagnostics on-site without requiring a laptop! Sample Screens DetCon Overview Screen shows the most important operating data of the connected DetCon control unit. Knocking Intensity Visualization of knocking intensity of each monitored cylinder. Different colors inform about the system status (Normal Reduction Critical). Trend of the Knocking Intensity Visualization of knocking intensity trend data for each individual cylinder. AlphaRail MOTORTECH WIRING RAIL SYSTEM MOTORTECH AlphaRail Wiring Rail System for Detonation Control MOTORTECH Stainless Steel, vibration resistant rail assembly will withstand any harsh environment commonly found in oil & gas industry. Our proven design is made for engine manufacturers and the global aftermarket. Do not go low-tech and take the risk of engine down time because of equipment being under repair. Eliminate the need for constant rewiring, connector exchanges or straightening out weak and bent aluminum wiring rails. 7

JF JF When things get hot our Service Team is at your site quickly. Regardless of which part of the globe we need to travel to. We know that the stakes are high, and therefore we outperform the others. That is because we want everything to run smoothly at your site, everywhere and at any time. This is entirely in keeping up with our motto: Let us drop everything and work on your problem! Distribution partner for DENSO spark plugs MOTORTECH GmbH Hogrevestr. 21-23 29223 Celle Telefon: +49 5141 93 99 0 Telefax: +49 5141 93 99 99 www.motortech.de motortech@motortech.de Headquarter Office Sales Partner MOTORTECH Americas, LLC 1400 Dealers Avenue, Suite A New Orleans, LA 70123 Telefon: +1 504 355 4212 Telefax: +1 504 355 4217 www.motortechamericas.com info@motortechamericas.com Distributed by: Copyright The copyright for all materials used in this MOTORTECH publication is reserved. Any kind of duplication or use of objects such as pictures or texts in other electronic or printed publications without approval by MOTORTECH is not permitted. Trademark Information All OEM names and part numbers shown are for reference purposes only. All trademarks, logos and symbols used or shown in this MOTORTECH publication are exclusive objects to the right of their owners and are used for reference purposes only. P/N 01.35.001-EN MOTORTECH SalesFlyer DetCon