Installation Instructions: External-Driver SEP T8 LED Tube Lamp

Similar documents
Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

Installation Instructions: Eco Linear High Bay

Installation Instructions: Eco-Fit T8 LED Tube Lamp

Installation Instructions: Eco SpunBay LED High Bays

LED 2/3/4ft T8 Tube 120V

Product Installation Instruction LED Tube Lamp Retrofit Kits

Universal Retrofit System Installation Instructions Revised:

Instruction/Installation Manual

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

LED Recessed Troffer Retrofit Kit

LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS


TECTONIC LED CORP. ISO

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

Optimax Pro Retrofit Instructions

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

INSTALLATION INSTRUCTIONS

Redbird LED Cardinal Stripit Kit Installation Instructions

Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A

LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

LED IMPORTANT SAFETY INSTRUCTIONS

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

Specification Sheet: Uni-Fit T8 LED Tubes. Indoor. 177 Broad Street, 12th Floor, Stamford, CT T rvlti.com

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

Installation Instructions BLTR and 2BLTR Relight Assembly

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

Assembly Instructions Retrofitting

Lumination TM LED Luminaire LUR Series

Customer service: or Upper mounting ring. Canopy

Solid State T8 tube is the smart alternative to a

Stik Families GENERAL PURPOSE RETROFIT SIGN CONVERSION FOR USE ONLY IN ACCORDANCE WITH KIT INSTRUCTIONS

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

LED REVEALS - INSTALLATION INSTRUCTIONS

Installation Instructions: ACCENT SYSTEM

Installation Instructions: HYPERION R-Lite SYSTEM

INSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02

ECO EXT (DIMMABLE)

MaxLite LED UTILITY WRAP FIXTURES

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Concealite Life Safety Products Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions

INSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit

TRUET5 EXT (DIMMABLE)

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

NOTE: The orientation of the mounting brackets are critical. (See Figure 4)

CFP-LED Contractor Select Flat Panel. Installation Instructions

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

IMPORTANT SAFETY INSTRUCTIONS

IP65 COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL. Exterior TILE Jumper Cable. Exterior Cutout TILE. Cable Clamp. T-Cable.

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

SURE-LITES FBP140XLP Instruction Manual

Incentives for Energy Efficient Lighting (Effective August 8, 2015 through December 15, 2015 * )

ECO-T LED RECESSED TROFFER USER MANUAL

Installation Instructions

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

FLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times

LED Utility Wrap Fixture

Motion and Light Sensor Kit LHBAS51

PIL0478 ISSUE 01/ 07/16

Model-GS109 Brake Light Controller Module Installation & Users Guide

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

MAXLITE RKT LED Retrofit Kit

MaxLite StaxMax LED Flood Lights

HBC-20 - LED HIGH BAY

MIRRORLITE RECESSED EMERGENCY LIGHTING

LED.Commercial 12W LED DD

INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL SINKER. By HAY

LEDlescent TM T8 Ballast-Free Lamps

General Installation Instructions LED

LED Linear Lamp. 2, 3, 4, 5 lamps. Performance Specifications. LED T8 and T12 lamps

INSTALLATION INSTRUCTIONS

LED T8 BP. GE Lighting. Tubular lamps DATA SHEET. Specification Features. Product information. Applications. IEC standards

CHEVY NOVA w/reverse Four Panel Sequential LED Taillight Kit Installation Guide

SAFETY. Read and understand all safety precautions and instructions before installing this product.

Quick Installation Guide. Affinium LED Modules LFM300 for Refrigerated Display Cases

Field Replacement of Fluorescent Power Supply in L-858 Signature Series Sign

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

LED IMPORTANT SAFETY INSTRUCTIONS

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

LM79 LM80 L70:5+ YEARS

6. Easy for maintenance & drivers replacement. Detachable in 1 minute. Part No. Power Luminous Input Voltage PF CRI Diffuser Certificate

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

SAVE THESE INSTRUCTIONS

PN R CHEVY CAMARO w/reverse Two panel Sequential LED Taillight kit installation guide. Kit Contents:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

UL AND CODE COMPLIANCE

T8 Tube Light. UL LISTED & cul LISTED & DLC LISTED. Germany Patent: Gebrauchsmusters / Nr

LED IMPORTANT SAFETY INSTRUCTIONS

Transcription:

Installation Instructions: External-Driver SEP T8 LED Tube Lamp Installation Notes & Precautions: External-Driver SEP T8 LED Tube Lamp Read all precautions, warnings, instructions contained in this document. These instructions can be used to install up to four lightweight, all-plastic External-Driver SEP T8 LED tube lamps into a properly wired luminaire/troffer. Before installing lamps, verify that luminaire tombstone spacing matches the base-to-base lamp length. Installation should be performed by a qualified electrician or installer. Operating voltages: 20VAC to 277VAC CAUTION: Wire the fixture as shown in Step 3 below. LED tube is powered from one end (SEP); the other end is NOT live and only serves to secure and mount the LED tube in the socket. Verify that the luminaire is properly set up for this style of LED Tube before inserting into luminaire (modify luminaire if necessary). WARNING: Do not use shunted lamp sockets when rewiring fixture for SEP LED tube lamps. Shunted lamp sockets are found only in fluorescent luminaires with Instant-Start ballasts. These ballasts are labeled Instant Start or I.S. or designated as IS on the ballast markings, for example F40T2/IS. For more information, contact your Revolution Lighting representative. Operating temperature range: -4 ºF to 3 ºF This light source is not intended as an emergency exit fixture or light. A Retrofitted Luminaire label is included with your LED tube. This decal must be placed in a prominent location on the luminaire so that it is visible when replacing an LED tube. If the luminaire is already modified for LED tube use and has a label, the new label may be discarded. The LED tube fits into any T-Series Medium Bi-Pin (T8/T0/T2) socket. Lampholder sockets do not need to be replaced unless they are shunted, damaged, or missing. Lampholders must be separated internally for proper wiring of the LED tube. Refer to installation diagrams. The LED tube may be used in open or enclosed surface or recessed (Type-IC) luminaires. If retrofitting an existing luminaire with LED tube(s), the initial luminaire retrofit wiring changes shall be performed by a qualified electrician. 77 Broad Street, 2 th Floor, Stamford, CT 0690 T 805 578 2536 E Support@rvlti.com rvlti.com Copyright 206 Revolution Lighting. All rights reserved. IN060_v0 0/25/6

Warnings: Cautions: WARNING Risk of fire or electric shock. Do not use this retrofit kit in luminaires employing shunted bi-pin lampholders. WARNING Risk of fire or electric shock. Do not alter, relocate, or remove wiring, lampholders, ballasts or any other electrical component. If necessary, contact a qualified electrician for assistance. WARNING To prevent wiring damage or abrasion, do not expose wiring to exposed edges of sheet metal or other sharp objects. WARNING Always disconnect power for your safety when performing the luminaire modification steps below! In some cases, it may be necessary to test the power feed with the power connected. Only connect the power when doing the testing, then disconnect the power from the luminaire when performing the steps below. WARNING Always follow local and regional NEMA Electrical codes. NEMA codes provide information on proper procedures, safety guidelines, proper tools, connection methods, and specifications on materials. WARNING Revolution Lighting Technologies, Inc. cannot and will not be liable for any modifications or results of modifications to electrical devices or luminaires. These instructions are provided as a reference. By using the included instructions, you are solely responsible for following all applicable electrical safety procedures, codes, methods, and materials. If you are unsure about any electrical modification or installation, please consult a licensed electrician or electrical contractor in your area. CAUTION Risk of Shock. Use in Dry or Damp Locations Only. CAUTION Do NOT install an LED tube into a fluorescent luminaire containing a ballast and/or starter. The ballast and/or starter must be removed prior to installation. CAUTION Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. 77 Broad Street, 2 th Floor, Stamford, CT 0690 T 805 578 2536 E Support@rvlti.com rvlti.com Copyright 206 Revolution Lighting. All rights reserved. IN060_v0 0/25/6

Contents: Carefully open the box and check contents. Contact Revolution Lighting if any items are missing. # EXTERNAL-DRIVER SEP T8 LED TUBE LAMP(S) [SKU #: (as ordered)] Lightweight, All-Plastic, External-Driver SEP T8 LED Tube Lamp(s) EXTERNAL LED DRIVER [SKU #: (as ordered)] External driver for powering, 2, 3, or 4 LED tubes, as ordered TOMBSTONE SOCKET KIT [SKU #: (Not included. Must purchase separately)] Tombstone socket kit for -, 2-, 3-, or 4-tube fixture installations that includes 2, 4, 6, or 8 sockets, respectively LUMINAIRE POWER SOURCE SOCKET LABEL [SKU #: 300004] This decal must be placed at the base of the powered LED tube socket on the LED-modified luminaire so that it is visible when replacing an LED tube. The arrow should point in the direction of the powered socket (only one label per retrofitted luminaire required at powered end). RETROFITTED LIGHT LUMINAIRE LABEL [SKU #: 300223] EXTERNAL-DRIVER SEP T8 LED TUBE INSTALLATION INSTRUCTIONS [SKU #: 300553_v0] This decal must be placed in a prominent location on the LED-modified luminaire so that it is visible when replacing an LED tube (only one label per retrofitted luminaire required). Provides information necessary to retrofit a luminaire with externally powered SEP LED tube lamps. External-Driver SEP T8 LED Tube Lamp Installation Instructions: STEP Disconnect power to installation site. WARNING: Ensure that all power is off using a voltmeter or other method. STEP 2 (Fixture Preparation) Fixture Stripped of Lamps, Ballast, Wiring & Sockets. Remove troffer lens, if present. Remove existing fluorescent tube lamps by rotating one quarter turn and sliding each lamp out. Dispose of them per job/company site rules and regulations. Remove ballast cover. (Cover may be secured with screws or tabs.) Remove existing fluorescent ballast as well as all existing wiring, socket covers, and sockets. Bare fixture is now ready for external-driver retrofit installation. 77 Broad Street, 2 th Floor, Stamford, CT 0690 T 805 578 2536 E Support@rvlti.com rvlti.com Copyright 206 Revolution Lighting. All rights reserved. IN060_v0 0/25/6

STEP 3 (Installation/Wiring of SEP External Driver) Sockets & Socket Covers Installed External Driver Wired In, One End 4-Lamp 2 x 2 Fixture with LED Driver & Sockets Installed 4-Lamp Wiring After Retrofit 3-Lamp Wiring After Retrofit 2-Lamp Wiring After Retrofit Snap the included, non-shunted sockets onto the mating notches of both socket covers. Install the included SEP external LED driver where the previous fluorescent ballast was. (Use appropriate self-tapping screws, if necessary.) Connect the low-voltage plus (+) and minus (-) power leads from the LED driver to each nonshunted socket as depicted in the adjacent wiring diagrams. (Diagrams show the wiring for 4-, 3-, 2-, and -tube fixtures.) Polarity is unimportant. Simply confirm that each socket has the same colored wire connected to it. (For example, the sockets of a four-tube fixture would be red-red, blue-blue, yellow-yellow, and orange-orange). Wire the socket(s) on one side of the fixture only. Sockets on the opposite side of the fixture serve only as lamp supports and are not powered. Using appropriate wire nuts, splice the hot (black), neutral (white), and ground (green/yellow) incoming power leads with the corresponding hot, neutral, and ground wires of the LED driver. OPTIONAL: To activate 0-0V dimming, splice purple (+) and gray (-) wires from LED driver to the incoming dimming control wires. (See dimming wires indicated in wiring diagrams. Capoff dimming wires if not used for optional 0-0V dimming.) Secure all fasteners, clips and wires (use electrical tape if necessary) and re-secure the socket covers at both ends of the fixture. Apply supplied label SKU #300004 with arrow pointing to the wired sockets of fixture, indicating modified power socket(s). Apply Retrofitted Luminaire Label SKU #300223 on inside of luminaire housing near one end of housing, next to powered sockets. Ensure that the label will not be covered by any cover pieces, trim pieces, or other items. If necessary, clean the area where label will be placed before affixing the self-adhesive label. -Lamp Wiring After Retrofit 77 Broad Street, 2 th Floor, Stamford, CT 0690 T 805 578 2536 E Support@rvlti.com rvlti.com Copyright 206 Revolution Lighting. All rights reserved. IN060_v0 0/25/6

STEP 4 (Lamp Installation, etc.) Read label on the included LED tube lamp to ensure that powered end of the tube is aligned with the powered luminaire socket, then insert single-end-powered LED lamp in the normal way by sliding the pins into tombstone sockets and gently rotating a quarter turn until LED tube locks in place. LED lamp is now fully installed. Repeat above step for all LED tube lamps. Replace ballast cover. Replace troffer lens, if present. Finished External-Driver SEP Tube-Lamp Retrofit STEP 5 Switch power back on. 77 Broad Street, 2 th Floor, Stamford, CT 0690 T 805 578 2536 E Support@rvlti.com rvlti.com Copyright 206 Revolution Lighting. All rights reserved. IN060_v0 0/25/6