Type EB, EBB, EBF and VEB DOUBLE SIDE BREAK SWITCHES 38 kv through 362 kv 600 to 3000 Ampere

Similar documents
TYPE EE and EEB CENTER- SIDE-BREAK SWITCH TYPE VEE and CBV CENTER BREAK V SWITCH 1200, 1600, 2000 & 3000 Amperes 7.

AIRBREAK SWITCHES East Ginter Rd. Tucson, Arizona USA (520) Fax (520)

TYPE V CENTER BREAK SWITCH

Aluminum Vertical Break Switch 345 kv, 1300 kv BIL 2000 A A.

Product Specifications for Aluminum Vertical Break Switches

Aluminum Vertical Break Switch kv A.

Operators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features

Copper Vertical Break Switch kv A.

Transmission Switching

Copper Double Break Switch

Product Specifications for Phase Over Phase GOABS(r)

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

SPECIFICATION BULLETIN

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

Disconnect & ByPass Switches

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Figure 1. HX cutout fuseholders.

Figure 1. HX cutout fuseholders. Positive Interruption

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

TYPE BILT DISCONNECT SWITCHES

Transmission Switching

Installation, Operation and Maintenance Manual

15 kv and 25 kv Thru-Bushings

D-73P disconnect and bypass switches

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Horizontal Circuit Switchers

Horizontal Circuit Switchers

S&C Recloser Bypass Disconnects

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Catalog 14A January 2013

25 kv Apparatus Bushings

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

Design Standard. Purpose: Design Standard:

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

IB-FAS3 Mar Type FAS THRU 115Kv Amp 61 KA Momentary. Vertical-Break, Gang-Operated Outdoor Air Disconnect Switch.

Typical Specification

INSTRUCTIONS Ç CAUTION. S&C Power Fuses Types SMD-1A, SMD-2B, SMD-2C, and SMD-3. For Field Assembly and Installation NOTE INSTRUCTION SHEET

SECTION PANELBOARDS

Specifications. S&C Mini-Rupter Switches Indoor Distribution (4.16 kv through 25 kv) Manually Operated Styles

M-Force three-phase switch

S&C Loadbuster Disconnects

TYPE BLT DISCONNECT SWITCHES

A200 NEMA Contactors and Starters A200

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

S&C Alduti-Rupter Switches. Outdoor Distribution, 14.4 kv through 69 kv

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

General + Definite Purpose Contactors

3.0OVERHEAD TRANSMISSION SWITCHES

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

600 A 15 and 25 kv class Cleer grounding elbow

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

M-Force three-phase switch

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

15-kV Safefront 600 Amp Primary Transformer Station Pad-Mounted Outdoor

[V] Common Control Transformer Control (See page 1-78 Note)

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

DC MILL DUTY CONTACTORS

A. Submit manufacturer's literature and technical data before starting work.

Two-position sidewall (horizontal) and cover (vertical) mounted loadbreak switches

15-kV Safefront 200 Amp Primary Transformer Station Pad-Mounted Outdoor

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Specifications. S&C Alduti-Rupter Switchesa Indoor Distribution (4.8 kv through 34.5 kv) Conditions of Sale SPECIAL TO THIS PRODUCT: How to Order

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

Industrial Control Transformers

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Pretest Module 29 High Voltage Unit 1

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

FX Full-Range Current-Limiting Fuse

WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO. GUARANTEED TECHNICAL PARTICULARS 1 of 2

T YPE MZ DISTRIBUTION S TANDARD CUTOUT

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Portable High-Voltage Cable Couplers 415, 515

Dry Well Cannister Type CLT, OIL Immersed PTAP-AFH926. Technical Guide Load-break, Dead-break

Make-Before-Break design available in both V- and T-blade switch types. ATTRIBUTES

15-kV Safefront 200 Amp Source Isolated Cable Switching Station Pad-Mounted Non-Fusible

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

Section 10: Terminal Blocks

Joslyn Hi-Voltage. Overhead Reclosers & Switches. In this section...

200 A and 600 A, 15, 25, and 35 kv junction bars for separable connectors

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

INSTRUCTIONS. S&c Circuit-Switchers - Mark v Grounding Switches - 70,000 Amperes Momentary Outdoor Transmission I INTRODUCTION INSTRUCTION SHEET 7 1 1

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Terminal Blocks. Section 12. Control Catalog 12-1

AVX. Operation and Maintenance Manual AVX 1200A A 15kV to 362kV. ALUMINIUM VERTICAL BREAK DISCONNECT SWITCH 15kV to 362kV 1200A A

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

S&C Manual PME Pad-Mounted Gear

15-kV Live Terminal 200 Amp Mini-Switch Source-Isolated Pad-Mounted Switchgear 40 Amp (Max) Arc-Strangler NX Fuses

Ground Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB

RAPIER DSB Disconnectors

Underground Distribution Switchgear

Loadbreak Apparatus Connectors

CMU medium voltage power fuses

www. ElectricalPartManuals. com

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Transcription:

Type EB, EBB, EBF and VEB DOUBLE SIDE BREK SWITCHES 8 kv through 62 kv 600 to 000 mpere TYPE EB 1 Morpac Industries, Inc. 2725 East Ginter Road Tucson, rizona 85706 520-294-452 FX 520-294-2

Type EB, EBB (VEB) GENERL DESIGN FETURES Type EB luminum Double Side Break Switch 72 kv through 62 kv 1200, 1600, and 000 mpere springs or other pressure compensating devices commonly found on other switches. The end result is a cleaner and better contact arrangement. The reverse loop contact takes advantage of the magnetic forces found under fault conditions to increase the contact pressure of the fingers and to force the blade against the closed position blade stop. The EB rotating center insulator, double side break switch embodies all of the rugged physical characteristics of the Memco product line. The design utilizes the best features of both copper and aluminum in the live parts, maintaining the time proven concept of silver to copper at all moving contacts. The result is a truly high performance switch. PPLICTION: With arcing horns, it can be used for line sectionalizing, by-passing circuit breakers, or opening magnetizing current of transformer primary connections. Without arcing horns, it can be used for isolating breakers or as a disconnecting switch. 2000 mpere jaw. FETURES Current Carrying Parts High strength, high conductivity aluminum is used where practical throughout the live parts. The blade is a one piece aluminum tube with aluminum castings welded to each end. tinned copper contact piece having a silver strip brazed to each edge is bolted between the two halves of each weldment and the joint is effectively sealed with an inhibiting compound to prevent the entrance of moisture. The switch is designed in accordance with latest NSI standards. It is also available, when specified, based upon past industry standards which limit temperature rise to 0 C over an ambient of 40 C. Jaw Contacts The jaw contacts employ special high temperature resistant, copper alloy contact fingers. This material, possessing excellent spring characteristics and high conductivity, makes an ideal self contained contact. There is no need for back-up Switch blade in jaw contact against blade stop. Morpac Industries, Inc. 2725 East Ginter Road Tucson, rizona 85706 520-294-452 FX 520-294-2 2

Type EB, EBB (VEB) Wiping ction & Operation The switch is operated by rotation of the center insulator stack. During closing the initial 70 of the insulator rotation swings the blade into the contact jaws, where the blade tips engage stops that limit the swinging action. Continued insulator rotation overcomes a biasing spring and toggle linkage causing the blade to roll 45 on its axis, applying contact pressure and latching into the jaw contact. During opening the first 45 of insulator rotation allows the compressed spring to return to its original position, and working through the toggle linkage, causes the blade to roll and relieve the pressure on the jaw contact loops. Continued insulator rotation swings the blade to the fully open position. Bases Rigid galvanized structural steel double channel bases are furnished. luminum bases are available when specified. Bearings Bearings in live parts are constructed of selflubricating low friction materials and require no lubrication or maintenance. Main bearing at the base of the rotating insulator is of heavy duty shielded ball bearing construction, providing the necessary strength and rigidity. No field servicing required. Leveling Bolts ll switches are furnished with four leveling bolts per insulator stack to provide fast, effective means of aligning insulator stacks in the field. Mounting Position The inherent balance of the blade allows the EB switch to be mounted in any position with no need for counterbalancing. Field conversion to another position requires no modification. Insulators NEM standard station post or cap and pin insulators are available as specified. Field Installation The simplicity of design assures ease of installation and years of trouble-free service. Rigid welded base showing bearing and leveling bolts. Morpac Industries, Inc. 2725 East Ginter Road Tucson, rizona 85706 520-294-452 FX 520-294-2

Type EB, EBB, EBF and VEB Type EBB, Copper Double Side Break Switch The EBB, double side break switch is a copper version of the aluminum EB switch. High conductivity copper and copper alloy castings are used in the live, conducting parts. The center hinge housing, which is not part of the current path, is made of aluminum to minimize weight of the switch. Blade end transitions, or separate blade tips, as described in the EB section are not necessary on the EBB since silver strips are brazed directly to the copper blade tip on the EBB. vailable ratings are the same as the EB s. Refer to the rating sheets at the front of this catalog. Type EBF, Copper Double Side Break Switch Blade construction is identical to that of the R14-C. (See R14-C section). Jaw construction is also identical to that of the R14-C, except that there are two jaws on the EBF. s with the R14-C, 69 kv switches have an articulated blade EBF design is simple, time proven and economical s up to 72.5 kv at 600 and 1200. Type VEB, luminum Double Side Break V Switch The VEB utilizes the same live parts and hinge mechanism as the EB. ll of the standard features and options for the EB apply as well the VEB Refer to the EB section of this catalog for live part construction details The V configuration offers a smaller footprint for those applications where structure space is at a premium. See tabulated drawing in this section s, like the EB, are up to 45 kv, 1200, 2000 and 000. ccessories and Options for EB, EBB, EBF and VEB switches Ground switches for either or both ends are available. Motorized operation Outriggers for copper or aluminum conductor uxiliary switches Key interlocks Customized operating mechanisms (May be available at no additional cost. Consult factory.) Morpac Industries, Inc. 2725 East Ginter Road Tucson, rizona 85706 520-294-452 FX 520-294-2 4

5 Morpac Industries, Inc. 2725 East Ginter Road Tucson, rizona 85706 520-294-452 FX 520-294-2

5 7 D EG RE E TO OP EN 0 1200 mperes Terminal Pads (4) 9 16 " Dia. Holes Each End 15 1 4" 4" R. 2" Furnished on control phase only 1 4" TOGGLE CTION BLDE TIP FOR 69 kv ONLY 1 1 2" NOTE 5 8 " 1 4" (2) 9 16 " Dia. Holes Each End 600 mperes Terminal Pads NOTE 2 1 4" H NOTE 4 NOTE 1 " 69 kv mperes Only (4) 9 16" DI. MTG. HOLES 4 1 2" B 4 1 2" 6" F E F D NOTES 1 Standard base shown, others available. 2 Silver to copper contacts furnished unless otherwise specified. rcing horns furnished only when specified. 4 Leveling screws provided for 69 kv rating. Voltage kv Max. BIL (1) CTLOG NUMBER (2) () Insul. Tech. Ref. No. pproximate Dimensions in Inches (Refer to Factory for Certified Prints) B D E F H 15.5 25.8 8.0 110 150 200 15EBF 6P 2EBF 6P 4EBF 6P 205 208 210 14" 14" 18" 28" 28" 6" 7" 7" 45" 24" 24" " 1 6 " 2 / 1 6 / " 2 6" 19 " / 4 2 " /4 27 " /4 48. 250 46EBF 6P 214 2" 46" 55" 9" 8" 1 / " 4 72.5 50 69EBF 6P 216 0" 60" 69" 51" 9" 40 " /4 (1) Catalog numbers shown are with station post insulators. (2) Catalog numbers shown are for 0 rise NSI C7.7 CCC designation 01. () Catalog numbers shown are for 600 amps. For 1200 amps, change 6 to 12 in the catalog number as required (eg.: 15 kv 1200 : Cat. No. 15EBF 12P). mpere 600 1200 Momentary 40 K 61 K Type EBF 15.5 kv 72.5 kv 600 and 1200 mpere Morpac Industries, Inc. 2725 East Ginter Road Tucson, rizona 85706 520-294-452 FX 520-294-2 6

1 15 DEG. T O OPEN 50 (4) 9 16 " Dia. Holes Each End 4 " 7 8 " 8 4 " R NOTE 2 Furnished on control phase only NOTE 4 NOTE 1 4" 1 4" 4" 4" NOTES 1 Standard base shown, others available. 2 2 pair contact loops furnished for 1200 ampere as shown. pair contact loops furnished for 1600 ampere and 4 pair contact loops for 2000 ampere. rcing horns furnished only when specified. 4 Corona rings furnished for 20 kv rating and higher. H J MIN. 70 0 0 (4) 11 16 " Dia. Mtg. Holes NOTE 1 16 4" 8 1 2" 16 4" 2 8 " 67 1 4" 2 8" 72" 8" 8 1 4" ( at 1050 BIL) (15" at 100 BIL) J MIN. OPEN GP CLERNCE Voltage kv Max. BIL CTLOG NUMBER (1) (2) () pproximate Dimensions Insul. (Refer to Factory Tech. for Certified Prints) Ref. No. H J R 72.5 50 69VEB 12HP5 278 40" 56" 22" 121 550 115VEB 12HP5 286 44" 67" 2" 145 650 18VEB 12HP5 288 50" 76" 8" 169 750 161VEB 12HP5 291 56" 84" 44" 242 900 20VEB 12HP5 04 70" 104" 50" 242 1050 20VEB 12HP5 16 75" 114" 57" 62 100 45VEB 12HP5 24 84" 128" 66" (1) Catalog numbers shown are with station post insulators. If cap and pin insulators are required, change the P to C in the catalog number (eg.: 69VEB 12HC5). (2) When 0 temperature rise unit is required, omit the H in the catalog number (eg.: 69VEB 12P5). () Catalog numbers shown are for 1200 amps. For 1600, 2000, or 000 amps, change 12 to 16, 20, or 0 in the catalog number as required (eg.: 161 kv 2000 : Cat. No. 161VEB 20HP5). (4) For 000 amp. switch refer to factory for dimensions. (4) mpere 1200 1600 2000 000 Momentary 61 K 70 K 100 K 100 K Type VEB 72.5 kv 62 kv 1200 thru 2000 mpere (000 ampere) (4) 7 Morpac Industries, Inc. 2725 East Ginter Road Tucson, rizona 85706 520-294-452 FX 520-294-2