HIGH VOLTAGE POWER SUPPLY DESIGN AND MANUFACTURING PRACTICES

Similar documents
700 Series Thermal Switch High Reliability

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Not all Low Voltage Switchgear is created equal

4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60

25 kv Apparatus Bushings

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

SF6 free high-voltage GIS installation in Zürich, CH.

NXPLUS C Single busbar. Maintenance-free for lifetime

JOHANSON DIELECTRICS INC Bledsoe Street, Sylmar, Ca Phone (818) Fax (818)

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Geometric vs. Capacitive Stress Control: choosing cable termination accessories to help reduce electrical stress.

Enhanced Breakdown Voltage for All-SiC Modules

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Not all Low Voltage Switchgear is created equal

Development of Large-capacity Indirect Hydrogen-cooled Turbine Generator and Latest Technologies Applied to After Sales Service

Introduction to Condition-Based Maintenance Best Practices

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

Technical Specification for Pole Mounted Capacitor Rack

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

Publication No.: PSG

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Reflected ripple current. Case Temperature rise above ambient ABSOLUTE MAXIMUM RATINGS

CHAPTER 6 ENVIRONMENTAL CONDITIONS

How to Handle a Reed Switch

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Package Thermal Characterization

4.Test Requirements: No mass loss,no leakage,no venting,no disassembly,no rupture and no fire,and the voltage retention is not less than 90%.

Kuhlman Electric Corporation Volt Instrument Transformers

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

Hydrogen Station Equipment Performance Device (HyStEP Device) Specification

15 kv and 25 kv Thru-Bushings

Presented to the IAPMO Standards Review Committee on December 9, 2013

DETAIL SPECIFICATION SHEET INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, CROSSLINKED CHLORINATED POLYOLEFIN, FLEXIBLE

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

TRANSPORT OF DANGEROUS GOODS

NXE2 Series Isolated 2W Single Output SM DC-DC Converters

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Development of Low-thrust Thruster with World's Highest Performance Contributing to Life Extension of Artificial Satellites

REAP CARE ROTATING ELECTRICAL ASSET PROGNOSTIC CARE

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

EE 741 Over-voltage and Overcurrent. Spring 2014

Welcome to KEMET Electronics Corporation s introduction to protection against surface arcing on high voltage MLCC training module.

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

ZX2 Gas-insulated medium voltage switchgear

LIQUID MEASUREMENT STATION DESIGN Class No

Modular Reconfigurable Spacecraft Small Rocket/Spacecraft Technology Platform SMART

MTU1 Series Isolated 1W Single & Dual Output SM DC/DC Converters

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description

Preparing the Site. Information About the Site Requirements CHAPTER

Reliability Evaluations and Test Functions Devised for Automotive Power Devices

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

REPORT OF TEST ON Elastimold Molded Vacuum Reclosers (MVRs)

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Test report. Type VRLTC load tap changer VRLTC 1500A Type test summary report

Comments on sub clause of IEEE draft 802.3bt/D2.4 Presenter: Arkadiy Peker Co-author : Yair Darshan May 15, 2017

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

Kuhlman Electric Corporation Volt Instrument Transformers

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

Independent Testing Laboratory for High Voltage Equipment

NME 5V & 12V SERIES. Technical enquiries tel: +44 (0) Isolated 1W Single Output DC/DC Converters

AMBR* Engine for Science Missions

Application Guidelines

Typical Technical Requirements for Electrical Machines and Components

Study of Fault Clearing by A Circuit Breaker In Presence of A Shunt Capacitor Bank

A manufacturer s view of bushing reliability, testing and analysis. Lars Jonsson Håkan Rudegard

Omnisafe High Performance Metal Face Seal, Multi Mate Demate, Torque Elimination Fittings No loosening, No particles

MTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters

CHAPTER 3. Experimental Test Set-Up

Breaking new ground. A circuit breaker with the capacity to switch 15 large power plants

Substation Equipment (Bushings)

XLB Series Power Supply Application Notes

Energy Division. PCA Single Column Polymeric Surge Arrester

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism

AIR COOLED RECTIFIER SPECIFICATION S-50-A

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability.

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current

NXE1 Series Isolated 1W Single Output SM DC/DC Converters

Lithium Battery UN38.3 Test Report

INSTALLATION PRODUCTION TESTS

Lithium Battery UN38.3 Test Report

Metal-Oxide Varistors (MOVs) Surface Mount Multilayer Varistors (MLVs) > MLN Series. MLN SurgeArray TM Suppressor. Description

Comparison of Partial Discharges in SF 6 and Fluoronitrile/CO2 Gas Mixtures

power pazifik Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV /10.3

Safety technique. Emergency Stop Module BH 5928, BI 5928

25kV 200A Loadbreak Bushing Insert and Elbow Design Test Report. Report Number:


25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

DETAIL SPECIFICATION SHEET INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, FLUORINATED ETHYLENE PROPYLENE, NON-CROSSLINKED

Analysis of Generator Stator Remaining Breakdown Voltage for Power Plant

Lithium Battery UN38.3 Test Report

FUSE TECHNOLOGY Ambient temperature

Shaft Grounding Rings. Protecting VFD Driven Motors from Bearing Currents

Lithium Battery UN38.3 Test Report

Transcription:

PAGE 1 OF 5 PREFERRED RELIABILITY PRACTICES Practice: Thoroughly test high voltage power supply packaging on flight configured engineering models, in a simulated space flight environment, to evaluate corona effects. Benefits: Process controls on design, manufacturing, and testing operations reduce component failure rates and improve reliability. The goal is production of power supplies that will operate in space for the mission duration. Programs That Certified Usage: Space Electronic Rocket (SERT) Tests I and II, Communication Technology Satellite (CTS), 30 cm Thruster Bi-module. Center to Contact for More Information: Lewis Research Center (LeRC) Implementation Method: There are special requirements in packaging HV power supplies for space use. The power processor should be voltage-partitioned and the low voltage circuits should be separated from the high voltage circuits. This is usually done with a metal wall. There still will be signals transmitted between the sections. All grounds should be isolated to provide a means to predict the currents when transients or arcs occur. When capacitors discharge, there can be current flows of several hundred amperes. The low voltage section should be protected from these current and voltage surges. Table 1 shows recommended design practices used for an 11 kv CTS TWT power supply. All volumes must be vented. The pressure in any unvented volume will decrease gradually and result in corona or arcing. Allow for screens, RF traps, etc.; and count only the holes in the screens. Interior volumes, down to the capped nut plates, must also be vented. LEWIS RESEARCH CENTER

PAGE 2 OF 5 TABLE 1. GUIDELINES Voltage Partitioning Isolated Grounds PHYSICAL LAYOUT (Separate high and low voltage components) (Provide known current path for transients) Voltage Suppression (Suppress signal from high voltage to low voltage circuits) Solid Dielectric: DC Stress AC Stress ELECTRIC FIELDS 50 Volts/MIL 10 Volts/MIL Surface Creepage 8 Volts/MIL Air or Vacuum Gap 20 Volts/MIL VENTING 2 >2 cm per 1000cc of enclosed volume (screens and RF traps reduce vent size), including: Capped nut plates Dielectric spacers Polyolefin shrinkable tubing High voltage connectors Figure 1 shows the fabrication methods used to build this supply. Round off all edges on metal as well as dielectric materials. Use anti-corona spheres. Void-free encapsulation is important. Remove excess RTV from bolts to keep vent paths open. Use shrink tubing in strips for hold downs, to avoid trapped air. Dielectric separators must be sized correctly for surface creepage. Anti-corona spheres should have a vent hole to eliminate voids in the solder. Dielectric inserts should be slotted to vent the interior volume.

PAGE 3 OF 5 Figure 1. High Voltage Power Supply Fabrication Figure 2 illustrates the special construction methods used in the HV compartment for the equipment to operate in the thermal and vacuum environment of space. Table 2 shows the testing methods that should be used to check out the HV power supply. The glass epoxy boards should be scanned ultrasonically to check for density differences. The transformers and components mounted on the boards should be corona-tested. Corona discharges of less than 5 picocoulombs are allowed. Induced voltage in the dielectric testing should be done in vacuum at temperature per MIL-T-27. The corona tests should be repeated to detect internal degradation from the high voltage stress. Be careful to bake out the components o at 65 C for 72 hours in the vacuum chamber and cool the components down before the power supply is turned on.

PAGE 4 OF 5 TABLE 2. TESTING Corona Testing: Electric Testing: Thermal Testing: Transformers Component Configuration on Boards <5 Picocoulombs Induced voltage (twice-rated voltage) Dielectrical withstanding (2.5 times rated AC and DC) Important to perform in vacuum at temperature Minimum of 10 temperature cycles at component level Minimum of 3 temperature cycles at box level o Initial thermal-vacuum test preceded by bakeout of 65 C for 72 hours Ultrasonic Scanning of Glass Epoxy Boards (NASA TM X-73432) Technical Rationale: These design criteria were developed experimentally. The various component configurations, board layouts, and component assemblies were tested to 125% of expected working voltage in air, vacuum, and full operating temperature with a requirement that the corona inception measured less than 5 picocoulombs. An example of an early flight failure caused by corona was a short that developed between two pins of a high voltage connector. Gas trapped inside connector voids gradually decreased in pressure until corona discharge began to decompose the insulating material. When the insulating material thickness was reduced to the point that leakage started increasing, a carbon tree formed and a short occurred, disabling the experiment. This can be easily avoided by running corona tests on all high voltage parts to ensure that no gases are trapped in high voltage circuits. Impact of Nonpractice: Allowing High Voltage power supplies that have not been thoroughly tested for corona to operate in space has resulted in corona-caused shorts that disabled the power supply.

PAGE 5 OF 5 References: 1. MIL-T-27, "Transformers and Inductors (Audio, Power and High-Power Pulse), General Specification for," August 08, 1987. 2. NASA CP 2159, "Spacecraft Transmitter Reliability," September 1979. 3. NASA TMX-3287, Lalli, Vincent R., Nueller, Larry A., and Koutnik, Ernest A., "System Reliability Analysis Through Corona Testing," September 1975. Presented at Power Electronics Specialist Conference (sponsored by IEEE), Culver City, CA (June 9-11, 1975). 4. NASA TMX-73432, Klima, S. J. and P. J. Riley, "Ultrasonic Evaluation of High Voltage Circuit Boards," June 1976. 5. NAS3-17782, Cronin, D. L., "Modeling and Analysis of Power Circuits," TRW Systems Group, June 1975. 6. NAVMAT P4855-1, "Navy Power Supply Reliability Design and Manufacturing Guidelines," December 1982. 7. Foster, W.M., "Thermal Test Report for the Space Acceleration Measurement System Circuit Boards", NASA Lewis Code 6730 Internal Report, November 1987