SafeSite LED Based Signaling for Hazardous Locations

Similar documents
SafeSite LED Based Signaling for Hazardous Locations

Vigilant LED High Bay - 60,000 lumens - UL / CSA. for Indoor and Outdoor Industrial Applications

SafeSite LED High Bay - High Efficiency - ATEX / IECEx. for Indoor and Outdoor Industrial Applications. MDTEXHBHEEU001_E

SafeSite LED High Bay - High Efficiency ATEX / IECEx INMETRO. for Outdoor Industrial Applications. MDTEXHBHEEU001_E

DuroSite LED Low Bay - UL / CSA. for Indoor and Outdoor Industrial Applications

SafeSite LED High Bay - ATEX / IECEx. for Indoor and Outdoor Industrial Applications

Dialight LED Area Light. Technical Specification Sheet - CE

Vigilant LED High Bay - 45,000-60,000lm - CE. for Indoor and Outdoor Industrial Applications

DuroSite LED Bulkhead / Wallpack - INMETRO. for Indoor and Outdoor Industrial Applications

SafeSite LED High Bay - High Efficiency - ATEX / IECEx. for Outdoor Industrial Applications. March Mar2018

Vigilant LED High Bay - 45,000-60,000lm - CE. for Indoor and Outdoor Industrial Applications

Vigilant LED High Bay - CE. for Indoor and Outdoor Industrial Applications

Vigilant LED High Bay - UL / CSA. for Indoor and Outdoor Industrial Applications

Vigilant LED High Bay - UL / CSA. for Indoor and Outdoor Industrial Applications

DuroSite LED Area Light - UL / CSA for Indoor and Outdoor Industrial Applications

StreetSense LED Street Light - UL for Roadway and Area Illumination

WLTwin77 Twin Aviation Obstruction Light. Data Sheet. Rev: 1.1

POINT CIRCLE-H LIGHTS PTPS LED TOUCHDOWN & POSITIONING SYSTEM LIGHTED TD/PM CIRCLE & H MARKINGS

WL-100 High Intensity Aviation Obstruction Light

Patent Pending. SafeSite LED Linear Fixture - UL 844 for Indoor and Outdoor Hazardous Locations

Airfield Lighting Product Description Solar Aviation Light AV70. Airstrip Barricade Caution Taxiway Threshold Obstruction

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Vigilant LED Area Light - CE Technical Specifications

Patent Pending. SafeSite LED Linear Fixture - UL 844 for Indoor and Outdoor Hazardous Locations

INDUSTRIAL OL - SERIES SOLAR LED INDUSTRIAL

APPLICATIONS APPROVALS. GASKET One piece neoprene. LATCHES Plated steel twist draw. ENTRIES 1 2 NPT feed-through outlets, 3 4 NPT outlets optional.

MagnaPro Hazardous Area Drop Lens Fluorescent

Patent Pending. SafeSite LED Linear Fixture - UL 844 for Indoor and Outdoor Hazardous Locations

TNA-AS-50 OMNI-DIRECTIONAL BATTERY POWERED PORTABLE AIRFIELD LIGHT (PAL) AND TACTICAL MARKER

L-801 HBM 150/2 Airport Rotating Beacon Compliant with Standards: FAA: L-801 AC 150/ (Current Edition) ICAO: Annex 14, para 5.3.

CYCLOPS Z Purge Indicator

DuroSite LED Area Light V AC, 24-48V DC, V AC Battery Backup

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

DuraPro Hazardous Area Fluorescent

SafeSite LED Area Light Technical Specifications

LED lighting for drilling & marine Pauluhn ZPL LED luminaires. Pauluhn ZPL. LED luminaires for drilling & marine applications

CYCLOPS Z Purge Indicator

POINT HELIPORT LIGHTS

XPF. XPFMax Performer/al FEATURES TECHNICAL SPECIFICATIONS

ILED Dorado. User Manual

25W Explosion Proof LED Light - C1D1-2 - C2D1-2 - Surface Mount - 50' Cord w/ EXP Plug

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

POINT OBSTRUCTION LIGHTS SOL LED SOLAR POWERED OBSTRUCTION SYSTEM

SafeSite LED High Bay - High Efficiency - ATEX / IECEx for Indoor and Outdoor Industrial Applications MDTEXHBHEEU001_E 1

Explosion Proof Drop Light - 12 Volt AC/DC Watt Incandescent - 25' Cord - Twist Lock Plug

CYCLOPS X Purge Controller XP Version

ILED Aquarius Illuminated Windsock. User Manual

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

CYCLOPS Y Purge Indicator

POINT ROLLOVER LIGHTS PRL LED v4 HELIPORT INSET LIGHT

TRB-400 MAXLUMINA ROTATING BEACON

AUTHENTIC LIFE SAFETY PRODUCTS SINCE 1940

SERIES 5A AND 5B VALVE STATUS MONITOR THE HIGH PERFORMANCE COMPANY BRAY SERIES 70 ELECTRIC ACTUATORS

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning

DuroSite LED Bulkhead Luminaire - CE For Industrial Application

Rig-A-Lite LED Luminaire Guide. Superior LED Technology for Hazardous and Severe Environments. Five-Year Warranty

C1D1 Solar Powered Explosion Proof LED Indicator Light - 80' Cord - C1D2 Panel

MODELS 2 & 4 Top Conduit Linears

INDUSTRIAL OBSTRUCTION LIGHTING OL SERIES: SOLAR LED INDUSTRIAL LIGHTING

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

MODELS. 2 & 4 Low Profile Linears

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

INDUSTRIAL OBSTRUCTION LIGHTING. reliable, low-cost solar led lighting OL SERIES: SOLAR LED INDUSTRIAL LIGHTING

Project: 1 IP65 Rated fixtures are rated for use outdoors where exposed directly to water from rain or irrigation.

LSA TM series. BBE LED Roadway, Area & Parking Lighting Luminaire V9: LSA-04/06/16. Performance Data:

TECHNICAL SPECIFICATIONS

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

INDUSTRIAL OBSTRUCTION LIGHTING

DATASHEET 16 Mar 2016

PANEL MOUNT EXPLOSION PROTECTED AIR CONDITIONERS

ALSF APPROACH LIGHTING. High-Intensity Approach Lighting System WITH ELEVATED SEQUENCED FLASHERS. Operating Conditions. Compliance with Standards

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

Big Ass Light High Powered Fixture

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

4300 WINDFERN RD. #100 HOUSTON TX VOICE (713) FAX (713) WEB: twrlighting.com IMPORTANT!!!

MAR SERIES Fluorescent Lighting for Hazardous Locations

C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens

Runway Guard Lights RGL 921 USER MANUAL GB

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations

POINT WIND CONE PWC FAA L-806 & L-807

INSTALLATION AND USER INSTRUCTIONS

MALSR APPROACH LIGHTING. Medium-Intensity Approach Lighting System WITH ELEVATED SEQUENCED FLASHERS AND STEADY BURNING LIGHTS

BMRX Series ROTARY LEVEL CONTROL

Explosion Proof Two Color LED Light - C1D1 & C2D1 - Green Arrow and Red X Indicators

16 Watt White LED Strip Light for Hazardous Location Lighting - 24" Surface Mount Bar - C1D2

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

HYBRID AIRFIELD GROUND LIGHTING REAL ALTERNATIVE FOR CONVENTIONAL AGL

C1D1 Solar Powered Explosion Proof LED Strobe Light - 20' 16/2 SOOW Cord - C1D2 Panel

POINT WIND CONE PWC FAA L-806 & L-807

JAMESBURY VALVCON QX-SERIES ELECTRIC ACTUATOR

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A

Valve Position Monitors

INSTRUCTION MANUAL (ATEX / IECEx)

KH Series Kemlux III Enclosed/Gasketed

Transcription:

SafeSite LED Based Signaling for Hazardous Locations

On when it matters most. Products and solutions that protect your business 2 www.dialight.com MDTFSFSTBROCHURE_H

Features & Benefits 5 year full performance warranty Resistant to shock and vibration High impact polycarbonate lens, UV, scratch & chemical resistant lens coating Reduction in expensive tower climbs and maintenance costs / unplanned site visits Requires smaller gauge wire Smallest Flash Head in the Industry Community friendly lighting system Dialight Timeline 1999 - First ever FAA certified LED L810 2001 - First ever FAA certified LED L864 2007 - First ever FAA certified LED L865/L864 2011 - First ever FAA certified LED L856 2012 - First ever FAA certified LED L856/L864 Dialight (LSE: DIA.L) is leading the energy efficient LED lighting revolution around the world for industrial and hazardous areas as well as transportation and infrastructure applications. For 40 years it has been committed to the development of LED lighting solutions that enable organizations to vastly reduce energy use and maintenance needs, improve safety, ease disposal and reduce CO2 emissions. www.dialight.com MDTFSFSTBROCHURE_H 3

SafeSite Hazardous Signals LED Based Signaling SafeSite L-864 Red LED Beacon Class I, Div 2 model FAA AC 150 / 5345-43G FAA EB No. 67D Class I, Div 2, Groups A, B, C, D UL1598 UL844 IP66 NEMA 4X DGAC Mexico ICAO (Annex 14 - Fourth Edition, July 2004) Canadian aviation regulation CAR 621.9 (Transport Canada) Features & Benefits ETL verified to FAA standards 5 year full performance warranty Uses 90% less energy than an incandescent Resistant to shock and vibration Drasticly reduces maintenace costs Flash or steady burn Mechanical Information: Fixture weight: Operating Voltage: 20 lbs 120-240V AC 50/60Hz power factor corrected supply Supply Voltage Ranges: Nominal +/- 10% Effective Intensity: Wattage: Red Night 2,000 cd Red Night 20W (Steady Burn) 3.3W (16.7% duty cycle) 20 flashes per minute with 0.5 second on time Power Factor: >0.9 Operating Temp: Synchronization: -40ºF to +131ºF (-40ºC to +55ºC) Multiple unit sync from single controller (Operates with other manufacturers of GPS sync devices) US Patent # 7,281,821 Temperature Ratings Ambient Temperature Range T4A -40ºF to +131ºF (-40ºC to +55ºC) Part Number Description Voltage Certification / Compliance D564-B13-001 Class I, Div. 2 Beacon 120-240V AC FAA (TC) L-864 4 www.dialight.com MDTFSFSTBROCHURE_H

Hazardous Signals LED Based Signaling SafeSite LED Based L-864 / L-865 Flashing Dual (White / Red) - Class I, Div. 2 SafeSite FAA approved (Check FAA Website for current certification) Class I, Div 2, Groups A, B, C, D Class II, Div 2, Groups F, G UL1598 UL8750 CSA C22.2 IP66 ICAO Annex 14, July 2009 ICAO Aerodromes Design Manual, Chapter 18 Canadian Aviation Regulation CAR 621 (Transport Canada) Mechanical / Electrical Information: Dimensions in inches [mm] Unit weight: Operating voltage: Effective intensity: Synchronization: 26 lbs (11.8 kg) White - 150V DC (through Controller) Red - 75V DC (through Controller) White Day - 20,000 cd White Night - 2,000 cd Red Night - 2,000 cd Multiple unit sync from single controller (operates with other units via RS485) US Patents #7,208,881 #7,568,821 7,604,380 #7,777,424 Temperature Ratings Ambient Temperature Range T5-40ºF to +131ºF (-40ºC to +55ºC) Part Number Description DHZ-BFHD-4C Red / White Flashhead www.dialight.com MDTFSFSTBROCHURE_H 5

SafeSite Class I, Div.2 rated L-864 Systems Example layout 3 x L-810 Hazardous Signals LED Based Signaling L864 Photocell AC Class I, Div.2 rated L-864 / L-865 Systems Example layouts 3 x L-810 L864 / 865 Photocell AC RS 485 Controller AC Power Supply 3 x L-810 L864 / 865 Photocell 3 x L-810 AC RS 485 RS 485 RS 485 Controller AC Power Supply AC Power Supply AC Power Supply 6 www.dialight.com MDTFSFSTBROCHURE_H

Hazardous Signals LED Based Signaling Vigilant CID2 red L-864 / L-810 Controller Class I, Div. 2 SafeSite Class 1, Division 2 Groups A,B,C,D IP66 NEMA 4X UL 1203, 8750 CSA C22.2 No 30, No. 250.13 Certifications & Ratings 5 year full performance warranty Flashing or steady operation 20, 30, or 40 flashes per minute Front panel indicators (power and alarm) Contact closures for alarms For use with Dialight s fixtures L-864 Red Beacon (CID2) = D464-B13-001 - max 2 per port L-810 Red Marker (CID2) = RTO-2R07-00X - max 8 per port L-810 Red Marker (CID2) = 860-2R01-00X - max 4 per port Multiple controllers can be synchronized for larger systems Corrosion resistant Easy to install Mechanical Information: Fixture weight: 80 lbs (36 kg) Electrical Specifications: Operating Voltage: Operating Temp: Wattage: Temperature Rating: 120-240V AC 50/60Hz power factor corrected supply -40 F to +131 F (-40 C to +55 C) 5W T4 Power Factor: > 0.9 Part Number Description Voltage DHZC-CTR-2C8-000 Controller for L-864 / L-810 Red lights 120-240V AC, 50/60 Hz www.dialight.com MDTFSFSTBROCHURE_H 7

SafeSite Controller for L-864 / L-865 Class I, Div. 1 and Class I, Div. 2 Hazardous Signals LED Based Signaling Class I, Div 1 Class 1, Div 2 Groups B, C, D UL 8750 UL 1203 IP66 T6 temperature rating NEMA 4X copper free aluminum enclosure Mechanical / Electrical Information: Unit weight: Operating voltage: 180 lbs (86.6 kg) 120-277V AC 125V DC Supply voltage ranges: Nominal +/- 10% Power supply wattage: Controller wattage: White Day - 85W White Night - 35W Red Night - 25W 15W The controller will be equipped with a green indicter light on front panel to show energized status as well as a red indicter light on the front panel for failure status. Part Number Description DHZC - CTD - 8C8-030 Controller for up to 3 L-864 / L-865 lights DHZC - CTD - 8C8-040 Controller for up to 4 L-864 / L-865 lights DHZC - CTD - 8C8-060 Controller for up to 6 L-864 / L-865 lights DHZC - CTD - 8C8-080 Controller for up to 8 L-864 / L-865 lights DHZC-PSD-4C8 Power Supply (1 required per L-864 / L-865 light) 8 www.dialight.com MDTFSFSTBROCHURE_H

Hazardous Signals LED Based Signaling Power Supply for L-864 / L-865 Class I, Div. 1 and Class I, Div. 2 SafeSite Class I, Div 1 Class 1, Div 2 Groups B, C, D UL 8750 UL 1203 IP66 T6 temperature rating NEMA 4X copper free aluminum enclosure Mechanical / Electrical Information: Unit weight: Operating voltage: 180 lbs (86.6 kg) 120-277V AC 125V DC Supply voltage ranges: Nominal +/- 10% Power supply wattage: Controller wattage: White Day - 85W White Night - 35W Red Night - 25W 15W Dimensions in inches [mm] Part Number Description DHZC-PSD-4C8 Power Supply www.dialight.com MDTFSFSTBROCHURE_H 9

SafeSite Long Life Photocell Class I, Div. 2 Hazardous Signals LED Based Signaling Class I, Div 2 Groups B, C, D UL 773A ISA 12.12.01 IP66 T4A temperature rating NEMA 4X copper free aluminum enclosure Mechanical / Electrical Information: Unit weight: 2.00 lbs (0.91 kg) Operating voltage: 12V DC (through Dialight Controller) Operating temperature: -40 o F to +131 o F (-40 o C to +55 o C) Dimensions in inches [mm] Part Number Description DHZB - 6000 - PEC Long Life Photocell 10 www.dialight.com MDTFSFSTBROCHURE_H

Hazardous Signals LED Based Signaling SafeSite L-810 Red LED Side Lights Class I, Div. 2 SafeSite Class I, Div 2 Groups B, C, D UL 1598 UL 844 IP66 T3C temperature rating NEMA 4X copper free aluminum enclosure Mechanical / Electrical Information: Unit weight: 1.25 lbs (0.56 kg) (retro unit) 2.00 lbs (0.91 kg) (single unit) 4.60 lbs (2.09 kg) (dual unit) Operating voltage: 48V DC (through Dialight Controller) or 120-480V AC Operating temperature: -40 o F to +131 o F (-40 o C to +55 o C) US Patents #6,425,678 Dimensions in inches [mm] Part Number Description Description For use with L-864 / L-865 Controller RTO - ER08-001 Single light - 3.5W (for use with L-864/L-865 systems) 12-48V DC RTO - ER08-002 Dual light - 7W (for use with L-864/L-865 systems) 12-48V DC For use with L-864 Controller RTO - 2R07-001 Single light - 6.5W (for use with L-864/L-865 systems) 120-240V AC RTO - 2R07-002 Dual light - 13W (for use with L-864/L-865 systems) 120-240V AC www.dialight.com MDTFSFSTBROCHURE_H 11

SafeSite SafeSite L-810 Red LED Obstruction Lights Class I, Div. 2 and ATEX / IECEx - V AC models Hazardous Signals LED Based Signaling FAA approved (Check FAA Website for current certification) Class I, Div 2, Groups A, B, C, D ATEX / IECEx Zone 2 IECEx SIR 08.0018X Sira 06ATEX4372X UL1598 UL844 IP65 / 67 NEMA 4X ICAO (Annex 14 - Fourth Edition, July 2004), DGAC Mexico Canadian Aviation Regulation CAR 621.9 (Transport Canada) Certifications & Ratings 5 year full performance warranty Uses 90% less energy than an incandescent Weather/corrosion resistant lamp assembly and housing Resistant to shock and vibration Available as single or dual unit Flash models available Withstand wind in excess of 150 mph (240 kph), salt fog Dimensions in inches [mm] Temperature Ratings Class I Div. 2 models ATEX / IECEx models Ambient Temperature Range T4A Ambient Temperature Range T4A -67ºF to +131ºF (-55ºC to +55ºC) -67ºF to +131ºF (-55ºC to +55ºC) Mechanical Information Single Units Fixture weight: Mounting: Dual Units Fixture weight: Mounting: Electrical specifications 7.14 lbs (3.24 kg) Threaded 1 NPT and 3/4 NPT bottom hub for mounting 16.06 lbs (7.28 kg) Threaded 1 NPT and 3/4 NPT bottom hub for mounting Volt Amps: 44 VA (120V AC ) -+10% 67 VA (230V AC Units) -+15% Input Power: Operating Temp: 14.5 W (120V AC Units) 16.0 W (230V AC Units) -67ºF to +131ºF (-55ºC to +55ºC) Construction Housing: Cast aluminum Lens: Glass Accessories (Hardware): Stainless steel US Patent # 6,425,678 12 www.dialight.com MDTFSFSTBROCHURE_H

Hazardous Signals LED Based Signaling SafeSite L-810 Red LED Obstruction Lights Class I, Div 2 and ATEX / IECEx - V AC models SafeSite Part Number Description Voltage Class I, Div 2 Models 860-2R01-001 Class I, Div 2, Single Unit 120V AC 860-2R02-001 Class I, Div 2, Single Unit 230V AC 860-2R01-002 Class I, Div 2, Dual Unit 120V AC 860-2R02-002 Class I, Div 2, Dual Unit 230V AC ATEX / IECEx Models 860-9R01-001 ATEX / IECEx, Single Unit 120V AC 860-9R02-001 ATEX / IECEx, Single Unit 230V AC 860-9R01-002 ATEX / IECEx,, Dual Unit 120V AC 860-9R02-002 ATEX / IECEx, Dual Unit 230V AC *Steady Burn www.dialight.com MDTFSFSTBROCHURE_H 13

SafeSite Hazardous Signals LED Based Signaling SafeSite LED Steady Burn Visual Signal Lights Colored Visual Signal Lights - Class I, Div. 2 and ATEX / IECEx - V AC models FAA AC No. 150/5345-43G Class I, Div 2, Groups A, B, C, D ATEX / IECEx Zone 2 IECEx SIR 08.0018X Sira 06ATEX4372X UL1598 UL844 Certifications & Ratings IP 65 / 66 NEMA 4X ICAO (Annex 14 - Fourth Edition, July 2004), DGAC Mexico Canadian Aviation Regulation CAR 621.9 (Transport Canada) 5 year full performance warranty Uses 90% less energy than an incandescent Weather/corrosion resistant lamp assembly and housing Resistant to shock and vibration Available as single or dual unit Flash models available Withstand wind in excess of 150 mph (240 kph), salt fog Dimensions in inches [mm] Mechanical Information Single Units Fixture weight: Mounting: Dual Units Fixture weight: Mounting: Electrical specifications 7.14 lbs (3.24 kg) Threaded 1 NPT and 3/4 NPT bottom hub for mounting 16.06 lbs (7.28 kg) Threaded 1 NPT and 3/4 NPT bottom hub for mounting Volt amps: 44 VA (120V AC ) -+10% 67 VA (230V AC Units) -+15% Input power: Operating temp: On / off time: 14.5 W (120V AC Units) 16.0 W (230V AC Units) -67ºF to +131ºF (-55ºC to +55ºC) 100:900 ms Construction Housing: Cast aluminum Lens: Glass Accessories (Hardware): Stainless steel US Patents #7,208,881 #7,568,821 7,604,380 #7,777,424 Temperature Ratings Class I Div. 2 models ATEX / IECEx models Ambient Temperature Range T4A Ambient Temperature Range T4A -67ºF to +131ºF (-55ºC to +55ºC) -67ºF to +131ºF (-55ºC to +55ºC) 14 www.dialight.com MDTFSFSTBROCHURE_H

Hazardous Signals LED Based Signaling SafeSite SafeSite L-810 LED Steady Burn Visual Signal Lights Colored Visual Signal Lights - Class I, Div. 2 and ATEX / IECEx - V AC models Part Number Description Voltage Color Class I, Div 2 - Single Fixture Models 860-2B01-001 Class I, Div 2, Single Unit 120V AC Blue 860-2G01-001 Class I, Div 2, Single Unit 120V AC Green 860-2Y01-001 Class I, Div 2, Single Unit 120V AC Yellow 860-2W01-001 Class I, Div 2, Single Unit 120V AC White 860-2B02-001 Class I, Div 2, Single Unit 230V AC Blue 860-2G02-001 Class I, Div 2, Single Unit 230V AC Green 860-2Y02-001 Class I, Div 2, Single Unit 230V AC Yellow 860-2W02-001 Class I, Div 2, Single Unit 230V AC White Class I, Div 2 - Dual Fixture Models 860-2B01-002 Class I, Div 2, Dual Unit 120V AC Blue 860-2G01-002 Class I, Div 2, Dual Unit 120V AC Green 860-2Y01-002 Class I, Div 2, Dual Unit 120V AC Yellow 860-2W01-002 Class I, Div 2, Dual Unit 120V AC White 860-2B02-002 Class I, Div 2, Dual Unit 230V AC Blue 860-2G02-002 Class I, Div 2, Dual Unit 230V AC Green 860-2Y02-002 Class I, Div 2, Dual Unit 230V AC Yellow 860-2W02-002 Class I, Div 2, Dual Unit 230V AC White ATEX / IECEx - Single Fixture Models 8609B02001 ATEX / IECEx, Single Unit 230V AC Blue 8609G02001 ATEX / IECEx, Single Unit 230V AC Green 8609Y02001 ATEX / IECEx, Single Unit 230V AC Yellow 8609W02001 ATEX / IECEx, Single Unit 230V AC White www.dialight.com MDTFSFSTBROCHURE_H 15

SafeSite Hazardous Signals LED Based Signaling SafeSite FLS LED Flashing Visual Signal Lights Colored Visual Signal Lights - Class I, Div. 2 - V DC models Class I, Div 2, Groups A, B, C, D UL1598 UL844 IP66 NEMA 4X Certifications & Ratings 5 year full performance warranty Uses 90% less energy than an incandescent Weather/corrosion resistant lamp assembly and housing Resistant to shock and vibration Available as a single unit Unique optically designed lens to enhance LED operation and provide 360º visibility Mechanical Information Fixture weight: Mounting: Electrical specifications 7.14 lbs (3.24 kg) Threaded 1 NPT and 3/4 NPT bottom hub for mounting Volt Amps: 44 VA (120V AC ) -+10% 67 VA (230V AC Units) -+15% Input Power: Operating Temp: On / off time: 14.5 W (120V AC Units) 16.0 W (230V AC Units) -67ºF to +131ºF (-55ºC to +55ºC) 100:900 ms Dimensions in inches [mm] Temperature Ratings Ambient Temperature Range T4 Ambient Temperature Range T3C -67ºF to +131ºF (-55ºC to +55ºC) -67ºF to +149ºF (-55ºC to +65ºC) Construction Housing: Cast aluminum Lens: Glass Accessories (Hardware): Stainless steel US Patent # 6,425,678 Part Number Description Voltage Color 120V AC Models FLS-2B01-001 Class I, Div 2, Single Unit 120V AC Blue FLS-2G01-001 Class I, Div 2, Single Unit 120V AC Green FLS-2R01-001 Class I, Div 2, Single Unit 120V AC Red FLS-2Y01-001 Class I, Div 2, Single Unit 120V AC Yellow FLS-2W01-001 Class I, Div 2, Single Unit 120V AC White 230V AC Dual Fixture Models FLS-2B02-001 Class I, Div 2, Single Unit 230V AC Blue FLS-2G02-001 Class I, Div 2, Single Unit 230V AC Green FLS-2R02-001 Class I, Div 2, Single Unit 230V AC Red FLS-2Y02-001 Class I, Div 2, Single Unit 230V AC Yellow FLS-2W02-001 Class I, Div 2, Single Unit 230V AC White 16 www.dialight.com MDTFSFSTBROCHURE_H

Hazardous Signals LED Based Signaling SafeSite FLS LED Flashing Visual Signal Lights Colored Visual Signal Lights - Class I, Div 2. - V DC models SafeSite Class I, Div 2, Groups A, B, C, D UL1598 UL844 IP66 NEMA 4X Certifications & Ratings 5 year full performance warranty Uses 90% less energy than an incandescent Weather/corrosion resistant lamp assembly and housing Resistant to shock and vibration Available as a single unit Unique optically designed lens to enhance LED operation and provide 360º visibility Mechanical Information Fixture weight: 7.14 lbs (3.24 kg) Mounting: Threaded 1 NPT Electrical specifications Operating Voltage:: 12-48V DC (nom) -+ 10% Input Power: 1.5 W Operating Temp: 40ºF to +149ºF (-40 C to +65 C) On/Off Time: 100:900ms Dimensions in inches [mm] Temperature Ratings Ambient Temperature Range T4 Ambient Temperature Range T3C -67ºF to +131ºF (-55ºC to +55ºC) -67ºF to +149ºF (-55ºC to +65ºC) Construction Housing: Lens: Accessories (Hardware): Cast aluminum Glass Threaded 3/4 NPT reducer Threaded 1 NPT plug Stainless steel cage US Patent # 6,425,678 Part Number Description Voltage Color FLS-2B09-001 Class I, Div 2, Single Unit 12-48V DC Blue FLS-2G09-001 Class I, Div 2, Single Unit 12-48V DC Green FLS-2Y09-001 Class I, Div 2, Single Unit 12-48V DC Yellow FLS-2R09-001 Class I, Div 2, Single Unit 12-48V DC Red FLS-2W09-001 Class I, Div 2, Single Unit 12-48V DC White www.dialight.com MDTFSFSTBROCHURE_H 17

SafeSite Hazardous Signals LED Based Signaling SafeSite FLS LED Flashing Signal Lights With Flat Base Junction Box - Class I, Div. 2 - V AC models Class I, Div 2, Groups A, B, C, D UL1598 UL844 IP65 / 66 NEMA 4X Certifications & Ratings 5 year full performance warranty Uses 90% less energy than an incandescent Weather/corrosion resistant lamp assembly and housing Resistant to shock and vibration Available as a single unit Unique optically designed lens to enhance LED operation and provide 360º visibility Mechanical Information Fixture weight: 7.14 lbs (3.24 kg) Mounting: Threaded 1 NPT on 4 sides and 1 on bottom Electrical specifications Volt Amps: Input Power: Operating Temp: On/Off Time: 44 VA (120V AC Units) 14.5 W (120V AC Units) -67ºF to +131ºF (-55ºC to +55ºC) 100:900ms Dimensions in inches [mm] Construction Housing: Lens: Accessories (Hardware): Cast aluminum Glass Threaded 3/4 NPT reducer Threaded 1 NPT plug Stainless steel cage Temperature Ratings Ambient Temperature Range T4 Ambient Temperature Range T3C -67ºF to +131ºF (-55ºC to +55ºC) -67ºF to +149ºF (-55ºC to +65ºC) Part Number Description Voltage Color FLS-2B01-005 Class I, Div 2, Flat Base 120V AC Blue FLS-2R01-005 Class I, Div 2, Flat Base 120V AC Red FLS-2Y01-005 Class I, Div 2, Flat Base 120V AC Yellow FLS-2G01-005 Class I, Div 2, Flat Base 120V AC Green 18 www.dialight.com MDTFSFSTBROCHURE_H

Hazardous Signals LED Based Signaling SafeSite SafeSite L-810 LED Visual Signal Lights With Flat Base Junction Box - Class I, Div. 2 models Class I, Div 2, Groups A, B, C, D UL1598 UL844 IP65 / 66 NEMA 4X Features & Benefits 5 year full performance warranty Uses 90% less energy than an incandescent Weather/corrosion resistant lamp assembly and housing Resistant to shock and vibration Available as a single unit Unique optically designed lens to enhance LED operation and provide 360º visibility Mechanical Information Fixture weight: 7.14 lbs (3.24 kg) Mounting: Threaded 1 NPT on 4 sides and 1 on bottom Electrical specifications Volt Amps: Input Power: Operating Temp: On/Off Time: 44 VA (120V AC Units) 14.5 W (120V AC Units) -67ºF to +131ºF (-55ºC to +55ºC) 100:900ms Dimensions in inches [mm] Construction Housing: Cast aluminum Lens: Glass Accessories (Hardware): Stainless steel Temperature Ratings Ambient Temperature Range T4 Ambient Temperature Range T3C -67ºF to +131ºF (-55ºC to +55ºC) -67ºF to +149ºF (-55ºC to +65ºC) Part Number Description Voltage Color 860-2B01-005 Class I, Div 2, Flat Base 120V AC Blue 860-2R01-005 Class I, Div 2, Flat Base 120V AC Red 860-2Y01-005 Class I, Div 2, Flat Base 120V AC Yellow www.dialight.com MDTFSFSTBROCHURE_H 19

North American HQ 1501 Route 34 South Farmingdale, NJ 07727 Tel: 732-919-3119 Fax: 732-751-5778 info@dialight.com Copenhagen Ejby Industrivej 91 B 200 Glostrup Tel: +45 8877 4400 Fax: +45 3582 0099 info-dk@dialight.com EMEA HQ Exning Road, Newmarket Suffolk, England, CB8 0AX Tel: +44 (0) 1638 665161 Australia office 38 O Malley St Osborne Park WA 6017 Tel: +61 (0) 8 9244 7600 Fax: +61 (0) 8 9244 7601 Brazil Alameda Mercurio, 225 American Park EMpresarial NR Indaiatuba SP 13347-662 Tel: +55 (19) 3113-4300 Fax: +55 (19) 3113-4300 vendas.brasil@dialight.com Houston office 16830 Barker Springs Rd Ste 407 Houston, TX 77084 Tel: 732-919-3119 info@dialight.com Middle East office Level 42 Emirates Towers (Office Tower) Sheikh Zayed Road Dubai, United Arab Emirates Tel: +971(0)4319 7686 Southeast Asia office 240 Macpherson Road #07-05 Pines Industrial Building Singapore 348574 Dialight reserves the right to make changes at any time in order to supply the best product possible. The most current models of this document will always be available at: www.dialight.com/assets/brochures_and_catalogs/illumination/ MDTFSFSTBROCHURE.pdf Warranty Statement: EXCEPT FOR THE WARRANTY EXPRESSLY PROVIDED FOR [HEREIN/ABOVE/BELOW], DIALIGHT DISCLAIMS ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, AND NONINFRINGEMENT. MDTFSFSTBROCHURE_H