Maximize your ROI Conext CL-60 String Inverter The ideal solution for decentralized power plants and commercial rooftops solar.schneider-electric.com 2016 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. All information is preliminary and will need to be confirmed at the time of order. BR20160728_Conext CL-60
solar.schneider-electric.com 2 Cost-effective, high-efficiency distributed power generation for commercial and utility scale solar applications Turn a rooftop or unused land into a profitable source of green, renewable energy with the Conext CL-60 String Inverter. At 60 kw with the capability of sustaining a maximum output 1 of 66kW at PF=1 this is Schneider Electric s most powerful and efficient string inverter. The Conext CL-60 is durable, easy to install and service, and designed from the ground up to maximize your revenue. With an industry-leading maximum efficiency of 98.9%, it reduces system losses and your Levelized Cost of Energy (LCOE). For commercial projects or utility scale developers seeking a solar solution that generates the maximum power, while promoting grid stability the Conext CL-60 is the smart business choice. Horizontal or vertical mount leaves more space for power generation The Conext CL-60 can be mounted vertically or horizontally with no reduction of efficiency, allowing installation in remote locations even under the solar array so owners can use more rooftop space for power-generating solar panels. Designed with the installer in mind The Conext CL-60 is a lightweight, compact, all-in-one design, with pre-wired connectors for fast and easy installation. It supports up to 16 strings for maximum design flexibility. An innovative configuration tool simplifies the commissioning stage, so you can get the system onto the grid and generate revenue faster. Distributed power generation Large commercial rooftops 1. Maximum usable AC output: 66 kw (IEC model); 63.4 kw (UL model)
3 solar.schneider-electric.com Why the Conext CL-60 inverter? Lower CAPEX, lower OPEX and higher revenue potential Lower startup costs (CAPEX) Easy to install, configure and commission Small housing, flexible configuration options Lower operating costs (OPEX) Optimized system design for lower operating cost-per-watt Weatherproof enclosure High reliability and easy servicing Higher revenue potential 98.9% maximum efficiency, up to 66kW output Global support Backed by a bankable company with 180 years of history A global support team, with personnel and parts in every major region Tough, durable design tested with MEOST (Multiple Environmental Over Stress Testing), HALT (Highly Accelerated Life Test) and THB (Temperature, Humidity and Bias testing). Vertical or horizontal mounting to tuck underneath solar panels and allow for a larger PV array. Schneider Electric s broad range of LV and MV products provide complete BOS (Balance of System) for commercial, industrial and utility scale applications.
solar.schneider-electric.com 4 Schneider Electric service and support committed to maintaining the value of your solar investment Protect your solar investment and maintain your system s efficiency and profitability with a Schneider Electric service contract. Wherever your system is installed, there is a Schneider Electric support team, trained in your system s technology, and your local power requirements and regulations. We maintain parts depots in every major region. Schneider Service currently supports over 4,500 commercial clients and over 300,000 solar power installations around the world. Typical Conext CL-60 applications: Rooftop of malls or big-box stores Ground mount for small community system Rooftop on commercial or industrial building As a company with a 180-year history, we offer the R&D and manufacturing depth to develop some of the industry s most advanced and reliable equipment, and the corporate stability to back it up with some of the strongest warranties. A Schneider Electric service contract, and our global network of authorized support and field service technicians, is your assurance of performance for the life of your investment.
PRELIMINARY Conext CL-60 String Inverter High efficiency to maximize your ROI solar.schneider-electric.com 5 Technical Specifications DC Side CL-60 E (IEC) CL-60 A (UL) Full power MPPT voltage range (PF=1) (VDC) 570-850 V 550-850 V Operating voltage range at nominal AC voltage 570-950 V 550-950 V Start voltage at nominal AC voltage 620 V 620 V Max. Short circuit current (ADC) 160 A 200 A Max. PV operating current (ADC) 120 A 120 A Number of MPPT / Max. Number of inputs per MPPT 1 / 14 1 / 8 (Y connector adopted for up to 16 strings) DC connectors / Max. Current per connector (ADC) MC4 / 12 A Amphenol Helios H4 / 25 A DC fuse 14 pairs (+/-), string monitoring included 8 pairs (+/-), string monitoring included DC switch / DC SPD / AFD Yes / Type II DIN rail surge arrester / Null Yes / Type II DIN rail surge arrester / Yes AC Side Nominal AC output power (1PU, PF=1) 60 kw 60 kw Max. AC output power (PF=1, nominal AC voltage) 66 kw 63.4 kw Max. Apparent power (nominal AC voltage) 66 kva 63.4 kva Nominal AC output voltage (VAC) / AC Voltage range (VAC) 400 V / 310 480 V 380 V / 295-456V Frequency / Frequency range 50 Hz & 60 Hz / 45-55 Hz & 55-65 Hz 60 Hz / 55-65 Hz Max. Output current (AAC) 96 A 96 A Power factor 0.8 lead to 0.8 lag adjustable 0.8 lead to 0.8 lag adjustable THD at nominal power < 3% <3% AC connection General Specifications Screw clamp terminal, AL - CU type cable compatible Screw clamp terminal, AL - CU type cable compatible Peak efficiency / Euro or CEC efficiency 98.9% / 98.7% 98.8% / 98.5% Power consumption at night time < 1 W < 1 W Enclosure rating IP 65 NEMA 4X Inverter weight 58 kg. 128 lb. Inverter dimensions (H x W x D) 95.8 x 65.2 x 25.0 cm 38.9 x 25.7 x 9.8 in Ambient air temperature for operation -25 to 60ºC, derating > 50ºC -13ºF to 140ºF, derating > 122ºF Max. Operating altitude 4000 m, derating > 3000 m 13123 ft, derating > 9842 ft Relative humidity % 0 100% condensing 0 100% condensing Audible noise <55dBA <55dBA Inverter mounting User interface and communications Wall mounting, vertical wall to 0º flat mounting Wall mounting, vertical wall to 0º flat mounting User interface Graphic display, 2 LED, buttons Graphic display, 2 LED, buttons Communication interface RS485-Modbus, Modbus-TCP (optional, Daisy chain over RS 485 as well as TCP), SunSpec profile compliance Regulatory approval Certifications (pending) VDE0126-1-1, EN62109-1, EN62109-2, G59/3, BDEW, VED ARN4105 Environmental RoHS, REACH and 4K4H RoHS CSAus, UL 1741, IEEE 1547, IEEE1547.1, CSA C22.2#107.1-01-2001, FCC Part 15 Subpart B, Class B Limits 2016 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. All information is preliminary and will need to be confirmed at the time of order. BR20160728_Conext CL-60
Schneider Electric Industries SAS Head Office 35 rue Joseph Monier 92500 Rueil Malmaison Cedex, France Phone: + 33 (0) 1 4129 70 00 www.solar.schneider-electric.com 2016 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.