SEMIS Simulation Tool for 6 pulse Controlled Rectifier

Similar documents
SEMIS ABB semiconductor simulation tool Web manual - two-level VSC

2600T Series Pressure Transmitters Custom Linearization Table with ABB Asset Vision Basic

news ABB inaugurates expanded Bipolar facility Highlights ABB Semiconductors Newsletter Page 2

Mounting instructions for StakPaks

Mounting instructions for 62Pak modules

Surge arrester POLIM-H..SD

Surge arrester POLIM-H.. ND

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Surge arrester POLIM-C.. HD

Voltage limiting device HVL

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

Product information. ECOSS Electronic compact starter for wound rotor drives

More power for railway lines Maximum efficiency with proven system behavior

Voltage limiting device HVL

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

PRODUCT BROCHURE. ABB Ability Wireless Monitor for surge arrester Enabling reliability and availability of power supply

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

W SERIES IMPULSE VOLTAGE TEST SYSTEM APPLICATION FEATURES

Overview Overvoltage protection

R13 SET - 1. b) Describe different braking methods employed for electrical motors. [8M]

Mechanical clamping of press-pack high power semiconductors

TriLine PowerModules Overview with Planing Examples

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Using Apollo Solar Remote Monitoring Software

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Second Edition. Power Electronics. Devices and Circuits. V. Jagannathan

Mini contactors B6, BC6 with 3 pole

Manual motor starters Overview and benefits

Installation Instructions

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

ABB central inverters PVS to 2091 kva

TSTE25 Power Electronics. Lecture 4 Tomas Jonsson ISY/EKS

PQstorI One stop solution for energy storage and power quality

Figure 1.1 "Bevel and hypoid gears" "Modules" Figure / August 2011 Release 03/2011

Learning Objectives:

GloboFleet. User manual. GloboFleet Downloadkey EAN / GTIN

ELECTRICAL MACHINES LAB.

DEEP SEA ELECTRONICS PLC DSE3210 Configuration Suite Software Manual

Measurement Products. WaterMaster electromagnetic flowmeter The perfect fit for all water industry applications

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

GPK for Design and Rating of Industrial Gearboxes

KISSsoft 03/2013 Tutorial 15

Traction systems for Light Rail Vehicles Selected references

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

FUSES FOR SEMICONDUCTORS

Working Model 2D Tutorial 2

UNISONIC TECHNOLOGIES CO., LTD UC5301

TwinLine The new system of wall-mounting and floor-standing cabinets

ST3S01PHD BATTERY CHARGE I.C.

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Surge arrester POLIM-H..N

Learning paths. The path to higher performance ABB UNIVERSITY. ABB University. Learning paths

PQC - STATCON The ultra fast Power Quality Compensator

Frequently Asked Questions. ABB low voltage drives Low Harmonic AC drives, 7.5 to 2800Hp

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

WB 23 & WB 27. High-Speed Eddy-Current Dynamometers WB 23 & WB 27. Features. Description. Operating principles

Course Name: POWER ELECTRONICS Course Code: EE603 Credit: 4

Commander SK. Technical Data Guide. Model sizes A to D and 2 to 6. AC variable speed drive for 3 phase induction motors

: Automation Laboratory 1

Operational Experience with Startup Optimization for Steam Boilers. E.ON s Staudinger, Heyden, Ingolstadt und Zolling Power Plants

Preparing and programming of ESGI 2 LPG supply system manual

Sensitive Triacs. Description. Features. 10Amps. Applications. Schematic Symbol. Symbol Parameter Value Unit = 50 C SOT-223 T L TO-92 T C

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Exercise 7. Thyristor Three-Phase Rectifier/Inverter EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Thyristor three-phase rectifier/inverter

Based on the findings, a preventive maintenance strategy can be prepared for the equipment in order to increase reliability and reduce costs.

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Thermal overload relay TF140DU and TF140DU-V1000

EAS822 (Contrac) Power Electronic Unit

KISSsoft 03/2017 Tutorial 15

Issue 2.0 December EPAS Midi User Manual EPAS35

DYNACOMP. The top-class reactive power compensator

Heat Dissipation Design

ZX2 Gas-insulated medium voltage switchgear

Dr. Daho Taghezout applied magnetics (CH 1110 Morges)

POWER FLOW SIMULATION AND ANALYSIS

Vehicle CAN Database. Porsche 911 (991) GT3 Cup Gen1 - Bosch Connector

Exercise 6. Three-Phase AC Power Control EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Introduction to three-phase ac power control

What is entire PressureNET? What are the features of entire PressureNet? What are the benefits of TPMS? Increased Safety.

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Electronic overload relay EF65, EF96 and EF146

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

ABB i-bus KNX DG/S x DALI-Gateway Basic

EC Gold Series Synchronous permanent magnet motor

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Electronic overload relays EF205 and EF370

ABB i-bus KNX Magnetic Contact EnOcean, 868 MHz MKE/A , 2CDG R0011

Operators and Maintenance Manual. Display EEM MOT 01 FE02.02

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

BRAKE TESTER DECELEROMETER

Power Metering. Energy Metering Energy Targeting Energy Monitoring. Product Guide. Innovation by Design. iautomation.com.au

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Power Assembly Complete Solutions

Mini Contactors Applications and Segments

Digital Hand Controller. Manual

4100C BOSS AC Shovel Drive System Overview. WMEA Edmonton - June 2008

GPK for Design and Rating of Industrial Gearboxes

Transcription:

User manual 5SYA 2110-01 SEMIS Simulation Tool for 6 pulse Controlled Rectifier ABB Semiconductors introduces its web based semiconductor simulation tool SEMIS. Providing thermal calculation of the semiconductor losses for common converter circuits, largely simplifies the selection of the device best fitting for your application. The SEMIS tool is a user friendly online application found on ABB Semiconductors website: www.abb.com/semiconductors Based on the available range of options according to the parameters selected, multiple ABB devices can be simulated at the same time. Once a simulation is run, SEMIS returns results on semiconductor losses as well as on the electrical parameters in the input and output of the circuit. The results are shown in both graphical (waveforms) and numerical (tables) way. The SEMIS tool is based on the PLECS simulation software. PLECS users can download our product models in the XML file format from the ABB Semiconductors website and use them for their own simulations. ABB also supports on customised converter simulation with PLECS on a project basis.

Contents 1. SEMIS models for controlled rectifiers 3 1.1 Page layout 3 2. Inputs 4 2.1 Circuit parameters 4 2.1.1 Supply 5 2.1.2 Ambient temperature 6 2.1.3 Load and control inputs 6 2.2 Thyristor product selection 6 2.2.1 Thyristor selection 6 2.2.2 Matching thyristors 7 2.3 Heatsink thermal resistance 7 3. Output results 7 3.1 Graphical output Waveforms 7 3.2 Results table 9 3.3 Definitions of AC-DC side results 9 4. Alerts & features 10 4.1 DC voltage alert 10 4.2 Temperature alert 10 2 User manual SEMIS Simulation Tool for 6 pulse Controlled Rectifier

1. SEMIS models for controlled rectifiers 1.1 Page layout When any of the controlled rectifier model is selected the following screen will appear. As an example the 6 pulse controlled rectifier model is shown. Figure 1. Page layout of six pulse controlled rectifier in ABB semiconductors website. 3 User manual SEMIS Simulation Tool for 6 pulse Controlled Rectifier

Each section of the user interface page is indicated in the next figure. Figure 2. Overview of user interface Secion-1 : General schematic of simulation circuit Section-2: Selection of thyristor and Heat sink Section-3: Simulation buttons Section-4: Waveforms for semiconductors and AC side current and voltage Section-5 : Tabular presentation of semiconductor performance and main circuit parameters 4 User manual SEMIS Simulation Tool for 6 pulse Controlled Rectifier

2. Inputs 2.1 Circuit parameters The circled elements shown in grey colour in the circuit schematic below can be clicked to enter corresponding values. Figure 3. Circuit parameters set up The circled elements shown in grey colour in the circuit schematic above can be clicked to enter the user defined values. 2.1.1 Supply The user can select the desired AC line to line voltage. If the voltage across the thyristor exceeds its maximum surge peak forward and reverse blocking voltage limit, the user will get overvoltage alarm message. To calculate the required maximum surge peak forward and reverse blocking voltage for a given line to line voltage, the following formula is used. V DSM or V RSM = 1.414 * V LL * k Where V LL is line to line voltage and k is the expected safety factor. The choice of k=2 is given as arbitrary default value, however this value can be changed by the user. It depends on the expected network conditions. Please confirm value by clicking OK button ONLY. Figure 4. Supply Voltage input block 5 User manual SEMIS Simulation Tool for 6 pulse Controlled Rectifier

2.1.2 Ambient temperature The user can define the desired ambient temperature. This component will accept a minimum value of -25 C and a maximum value of 90 C. Please confirm value by clicking OK button ONLY. Figure 5. Ambient temperature input block 2.1.3 Load and control inputs The user has to input the desired DC load current and firing angle as shown in Figure 6. The value of commutation reactance should be provided as a percentage of base value of impedance: Figure 6. Input parameters DC CURRENT: Selection range up to 7000 A ALPHA ANGLE: Selection range is 1 to 60 COMMUTATION REACTANCE: Selection range is 1% to 25% 2.2 Thyristor product selection Various thyristor types can be selected and simulated by entering the following parameters: 2.2.1 Thyristor selection Figure 7. Thyristor voltage rating input block 6 User manual SEMIS Simulation Tool for 6 pulse Controlled Rectifier

2.2.2 Matching thyristors By clicking on the product code name the user may access the data sheet from ABB website. Figure 8. Matching thyristors for selection The user can select the desired thyristor product names for simulation. Up to 4 elements can be selected simulatenously and simulated. If one or more elements produce results that are exceeding the safe operating area (SOA) the simulation will stop. In this case the user should run the simulation again changing parameters and/or product selection suitably, so that the results are within SOA. 2.3 Heatsink thermal resistance The heat sink R th value can be entered by the user through the following input section. Figure 9. Heat sink thermal resistance input block The value entered is attributed to each individual switch shown in the electrical configuration schematic of the thyristor module data sheet. 3 Output results As soon as the user has defined all necessary parameters the simulation can be started by pressing the relevant button. The output results are displayed in two different ways. They are graphical output and numerical output (listed in tables). When the simulation finishes, the semiconductor as well as both AC and DC side waveforms will appear as shown in Figure 10: 3.1 Graphical output Waveforms In figure 10 the available buttons are marked with black and numbered. They allow for the following functions : 1 Hide selectively waveforms of products. 2 Make all generated product waveforms available for next simulation. 3 Selectively hold results for next simulation. If one waveform has been selected to be kept for next simulation then its symbol indication changes to red. If one clicks on the red symbol again it is then deleted. 4 Cursor button reveals the two cursors on each graph and also a comprehensive table that serves as legend for the waveforms. By moving the cursors horizontally user may determine the difference in value between two desired time instants. 5 Clicking on button allows to zoom in by scrolling on the desired waveform and clicking on button resets initial view. 7 User manual SEMIS Simulation Tool for 6 pulse Controlled Rectifier

Figure 10 Graphical results Figure 11. 6 Pulse and 12 Pulse controlled rectifier circuits 8 User manual SEMIS Simulation Tool for 6 pulse Controlled Rectifier

3.2 Results table The following parameters are given in a tabular format. 1 Device losses and temperatures 2 Converter AC parameters 3 DC parameters and control parameters Figure 12. Results table of six pulse controlled rectifier 3.3 Definitions of AC-DC side results Device losses & temperatures Conduction losses: Losses during on state (Static) based on ABB data sheet values. All types of semiconductor losses are calculated according to PLEXIM software principle through reference of look up table. Combined losses: Equal to switching losses + conduction losses Converter losses: Aggregated amount of losses on all consisting semiconductor elements of the converter (e.g. 6 x loss across each thyristor for 6 pulse circuit) Average junction temperature: Mean value of generated waveform for junction temperature for each semiconductor. Losses (%): Defined as the (%) ratio of calculated combined converter losses to the input power depending on converter operation. 9 User manual SEMIS Simulation Tool for 6 pulse Controlled Rectifier

AC side results: AC frequency: Frequency of the fundamental harmonic of the AC waveforms for voltage and current in AC side of converter (defined by user through the controller block). Phase voltage (RMS): AC phase value according to 1 st order harmonic of AC frequency. Phase current (RMS): AC phase value according to 1 st order harmonic of AC frequency. Reactive power: Effective power on converter AC side calculated as: Q = 3 * V ph * I ph * sin(θ) where V ph, I ph, θ stand for phase voltage (RMS), phase current (RMS) and power factor angle respectively. Real power: Effective power on converter AC side calculated as: P = 3 * V ph * I ph * PF, where V ph, I ph, PF stand for phase voltage (RMS), phase current (RMS) and power factor respectively. DC side results: DC power: Power seen in DC side of rectifier circuit. DC voltage: The value of DC voltage is calculated accounting the user inputs for alpha angle and commutation inductance L s using the following equations. Average thyristor current: Current flowing through each thyristor device of the converter. Equals to one third of the average DC current defined by the user. 4. Alerts & features 4.1 Voltage alert If the voltage across the thyristor exceeds its maximum surge peak forward and reverse blocking voltage limit, the user may get overvoltage alarm message as shown below. Figure 13. Thyristor voltage setting alarm message 4.2 Temperature alert When the average junction temperature of the thyristor is above its allowed value, alert message will be displayed as follows. Figure 14. Thyristor alarm message for over-temperature 10 User manual SEMIS Simulation Tool for 6 pulse Controlled Rectifier

Contact us ABB Switzerland Ltd. Semiconductors Fabrikstrasse 3 5600 Lenzburg, Switzerland Phone: +41 58 586 1419 Fax: +41 58 586 1306 E-Mail: abbsem@ch.abb.com www.abb.com/semiconductors Note We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2014 ABB All rights reserved 5SYA 2110-01 December 2016 SEMIS Simulation Tool for 6 pulse Controlled Rectifier