New York City Apartment Metering Meter Sockets / Load Centers

Similar documents
MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

Power Mod. Introduction.

Section 6 Electric Metering: Residential

MP Meter-Pak Meter Centers

Introduction. Upon completion of Basics of Meter Mounting Equipment

fastfax Rock Solid TM Load Centers General Information

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

Meter Centers Meter Mounting Devices

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

Equipment. Metering. Metering Equipment 1. Contents

MEG Approval Meter Equipment Group

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module

Equipment. Metering. Metering Equipment 1. Contents

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Wisconsin Area Catalog

Modular Metering Application Guide

CON EDISON EQUIPMENT

Modular Metering. Canadian Version

Modular Metering Construction Details

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

10. METERING General Requirements

Meter Mounting Equipment Wisconsin Area

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved

Meter Mounting Equipment DTE Energy Area

METERING REQUIREMENTS

Design Standard. Purpose: Design Standard:

Power Mod. Standard Tapboxes.

Group Meter Main - Without Bypass

Accessories. Accessories. Meter Mounting Equipment

Meter Mounting Equipment. Northern Indiana Public Service Co.

AMENDMENT ELECTRIC SERVICE MANUAL 2014

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

SAFETY SOCKET BOX. Note 8 3" MIN. 3" Max. (200 A)

6.2. Power Pedestals. Contents

CT Metering. CT Metering. Meter Mounting Equipment

Duke/MEG Approval Meter Equipment Group

Multiple Metering, Vertical Gang

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting

Multiple Metering, Horizontal Gang - Non Lever Bypass

Selection and Application Guide For use in New England EQUIPMENT

REC Municipal Meter Mounting Equipment

SPEEDFAX TM 2011 Meter Centers Contents

POWER PRODUCT Meter Centres Contents

5.2. Power Pedestals. Contents Description

Contents. Volume 1 Residential and Light Commercial CA E December

Louisiana/Mississippi. Area Catalog

Recreational Vehicle Park Electrical Products & Accessories

Meter Mounting Equipment. GA/AL/FL Panhandle Area

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection

Service Entrance Methods

10 Commercial, Industrial, Agricultural Services

Metering NEED. Meter Sockets. Product Description

Clark Public Utilities Commercial Electric Service Handbook. This page left blank intentionally.

Ohio Meter Mounting Equipment

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering

Modular Metering Application Guide. Meter Mod * III Product Family

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...

Selection & Application Guide. BFT Main Feed Thru Modules. Power Mod. usa.siemens.com/powermod

Single Socket and Horizontal Metering

Indiana Meter Mounting Equipment

Contents. 4 Loadcentres

SECTION VII METERING INSTALLATIONS

Selection and application guide

Multi-Pak Group Control

Single Socket and Horizontal Metering

Meter Mounting Equipment Florida Area Catalog

New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

TERMINATION ENCLOSURE OPTIONS

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets

5.11. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

ComEd Service Area Meter Mounting Equipment

Specialty Service Entrance Switchboards. Selection and Application Guide

Instrument Rated Metering Equipment

tot (Ibs.) Number ** U7310-RL U7310-RL-TG i :;:r"0? 10:5 S3» ilm; ,

EZ Meter-Pak Meter Centers

Selection and application guide. For use in Ohio. Meter Mounting Equipment.

Heavy Duty Safety Switches

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

Wall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type 12

UNDERGROUND SERVICES - SECONDARY

STOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

Power Mod. Type WMM Residential Meter Stacks. Revised 06/01/13. Residential Meter Stacks

For vertical multi-meter installations 1-6 meter positions Designed to receive watthour meters that meet ANSI C12.10 Overhead or underground feed

Metering and Service Installation:

Design Guide for Integration of Fixed-Mount Circuit Breakers

Application guide. Tmax Link OEM UL 891 Switchboard Program

Meter Centers & Loadcenters Group Metering

Selection and application guide

Product Specification Sheet #3LD2.1

5.1. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. Product Description. Single Meter Sockets

Transcription:

s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001

Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase, 4 Wire or 120/240V AC, 1 Phase, 3 Wire Maximum line terminal - (2) 500 kcmil/phase Output: 120/208Y, 1 Phase, 3 Wire or 120/240V AC, 1 Phase, 3 Wire, 100 amps continuous/meter position (125 amps maximum) Meter Sockets: 5 jaw, with 5th jaw located at 9 o clock and electrically connected to neutral bus Tenant Circuit Breakers: Use Siemens Type QP 2-pole plug-on circuit breakers, (100 amps maximum) Product Descriptions Siemens New York City Apartment Metering is a versatile, unassembled modular metering product comprised of separate modules that may be assembled to produce a variety of configurations. Only those standard modules shown in this publication will be sold. Installation instructions are shipped with the product. The modules are: Meter Stacks Meter stacks are available from 2 to 5 meter positions, arranged vertically and pre-bussed on the line side. Each meter position is rated 100 amps continuous (125 amps maximum), 5 jaw, with the 5th jaw located at 9 o clock and connected to the stack neutral bus. For indoor mounting only. Line Troughs Line troughs are indoor horizontal wireways that support the meter stacks and supply unmetered line power to meter stack bus. Line trough is available from 2-5 stack positions and may be ganged by means of couplers to accommodate 6 or more stacks. Phase blocks and line terminals are required to terminate line conductors and to provide means to field wire each stack. Trough end walls are ordered separately. Phase Blocks Phase blocks are required to terminate line conductors and provide terminals for field connection to each stack bus. Phase blocks are available with 3, 6 or 12 take-off lugs. 2

Line Terminal Kits Line terminals are available in kits of 4 terminals each. The terminals are tang lugs which mount on threaded studs provided on the phase blocks. Terminals are available in 3 sizes: (1) 350 kcmil (1) 500 kcmil (2) 500 kcmil maximum End Wall Kits These kits each contain 4 end walls; 2 end walls for the line trough and 2 end walls for the breaker trough. Coupler Kits These kits each contain 2 trough coupler straps; one for the line trough and one for the breaker trough. These couplers mount using the same mounting screw holes as the end walls. Breaker Troughs Breaker troughs are horizontal indoor wireways that contain provisions for plug-in circuit breakers used as tenant mains. The troughs bolt to the top of the meter stacks. Field wiring connects each meter socket to a circuit breaker mounting block. Breaker troughs are available in 2 to 5 stack positions and can be ganged to accommodate 6 or more stacks. Trough end walls are ordered separately. Circuit Breakers New York City Apartment Metering uses standard 2-pole plug-on circuit breakers, Siemens Type QP, 100 amps maximum. Getting Started Line Trough Spacer Kits These kits may be used to increase wire bend space between the first phase block and line entrance end wall, if necessary. They connect to line troughs with a standard coupling kit. Trough end walls are ordered separately. Before ordering components, the following should be known: installation instructions are shipped with the product. number of meter positions amp rating of each meter position voltage and phase of incoming line line conductor size and quantity per phase vertical and horizontal space limitations, if any Meter stacks are 10 wide and are 10 high for each meter position, or blank position. (A 3-high stack with no blank positions would be 10 wide and 30 high). When considering the overall height of an installation, you must add the height of the line trough (12 ) and the breaker trough (16 ) to the stack height. An installation of 3-high stacks would be 58 in overall height (30 + 12 + 16 = 58 ). All meter stacks in the same meter bank must be the same height to allow the breaker trough to fit on top of the stacks. 3

Selection and Specifications Meter Stacks Selection Chart #1 Meter Bank Height and Width Meter Stack Combinations for Various Heights and Widths, by Number of Meter Positions No. of 58 High 68 High 78 High Meter Use this Quantity of: Width Use this Quantity of Width Use this Quantity of: Width Positions SUVS310 SUVS311B (Inches) SUVS410 SUVS411B (Inches) SUVS510 SUVS511B (Inches) 9 3 0 30 Not Practical 1 1 20 10 2 2 40 1 2 30 2 0 20 11 3 1 40 2 1 30 Not Possible 12 4 0 40 3 0 30 Not Practical 13 3 2 50 1 3 40 1 2 30 14 4 1 50 2 2 40 2 1 30 15 5 0 50 3 1 40 3 0 30 16 4 2 60 4 0 40 Not Practical 17 5 1 60 2 3 50 1 3 40 18 6 0 60 3 2 50 2 2 40 19 5 2 70 4 1 50 3 1 40 20 6 1 70 5 0 50 4 0 40 21 7 0 70 3 3 60 1 4 50 22 6 2 80 4 2 60 2 3 50 23 7 1 80 5 1 60 3 2 50 24 8 0 80 6 0 60 4 1 50 25 7 2 90 4 3 70 5 0 50 26 8 1 90 5 2 70 2 4 60 27 9 0 90 6 1 70 3 3 60 28 8 2 100 7 0 70 4 2 60 29 9 1 100 5 3 80 5 1 60 30 10 0 100 6 2 80 6 0 60 31 9 2 110 7 1 80 3 4 70 32 10 1 110 8 0 80 4 3 70 33 11 0 110 6 3 90 5 2 70 34 10 2 120 7 2 90 6 1 70 35 11 1 120 8 1 90 7 0 70 36 12 0 120 9 0 90 4 4 80 37 11 2 130 7 3 100 5 3 80 38 12 1 130 8 2 100 6 2 80 39 13 0 130 9 1 100 7 1 80 40 12 2 140 10 0 100 8 0 80 Use (3) SUVS310 instead of (3) SUVS411B. Use 3-high or 4-high stacks. Specification Chart #1 Meter Stacks 300V AC max., 100 Amps/Position Continuous Duty, 1 or 3 Phase Network Meter Height Catalog Wire Range Positions (Inches) Number Quantity Approx. Wt. (lbs.) Line Terminals 2 20 SUVS210 1 15 #6-4/0 2 30 SUVS311B 1 21 #6-4/0 3 30 SUVS310 1 22 #6-4/0 3 40 SUVS411B 1 29 #6-4/0 4 40 SUVS410 1 30 #6-4/0 4 50 SUVS511B 1 37 #6-4/0 5 50 SUVS510 1 38 #6-4/0 All stacks are 10 wide. Meter Stacks (Use Selection Chart #1 and Specification Chart #1) Knowing the number of meter positions, and the height and width requirements, select quantity and catalog number of stacks from Selection Chart #1. The height dimension in this chart includes line and breaker troughs. For specs, refer to Specification Chart #1. 4

Selection and Specifications Line Troughs / Breaker Troughs / Phase Blocks Line Troughs Specification Chart #2). Knowing the number of meter stacks (not meter positions!) from above, select the quantity and catalog numbers of line troughs from Selection Chart #2. For specs, refer to Specification Chart #2. Breaker Troughs Specification Chart #3) Using the total number of meter stacks (not meter positions!), select the quantity and catalog numbers of breaker troughs from Selection Chart #2 and spec from Specification Chart #3. Use QP style breakers only. Breakers not included. Phase Blocks Specification Chart #4). Using the number of meter stacks and the incoming power supply, use Selection Chart #2 to determine the quantity and catalog number of phase blocks for line and neutral termination. Spec these from Specification Chart #4. Selection Chart #2 Line Trough, Breaker Trough and Phase Block Selection Phase Block Selection No. of Meter Line Trough Selection Breaker Trough Selection 3 Phase, 4 Wire System 1 Phase, 3 Wire System Stacks Left Middle Right Left Middle Right Line Neutral Line Neutral in Bank Trough Trough Trough Trough Trough Trough Blocks Block Blocks Block 3 SULT30 SUBT30 (3) SUPB3 (1) SUPB3 (2) SUPB3 (1) SUPB3 4 SULT40 SUBT40 (3) SUPB3 (1) SUPB6 (2) SUPB6 (1) SUPB6 5 SULT50 SUBT50 (3) SUPB6 (1) SUPB6 (2) SUPB6 (1) SUPB6 6 SULT30 SULT30 SUBT30 SUBT30 (3) SUPB6 (1) SUPB6 (2) SUPB6 (1) SUPB6 7 SULT40 SULT30 SUBT40 SUBT30 (3) SUPB6 (1) SUPB12 (2) SUPB12 (1) SUPB12 8 SULT40 SULT40 SUBT40 SUBT40 (3) SUPB6 (1) SUPB12 (2) SUPB12 (1) SUPB12 9 SULT50 SULT40 SUBT50 SUBT40 (3) SUPB6 (1) SUPB12 (2) SUPB12 (1) SUPB12 10 SULT50 SULT50 SUBT50 SUBT50 (3) SUPB12 (1) SUPB12 (2) SUPB12 (1) SUPB12 11 SULT40 SULT40 SULT30 SUBT40 SUBT40 SUBT30 (3) SUPB12 (1) SUPB12 (2) SUPB12 (1) SUPB12 12 SULT40 SULT40 SULT40 SUBT40 SUBT40 SUBT40 (3) SUPB12 (1) SUPB12 (2) SUPB12 (1) SUPB12 Spacer SULT10SP is required if line conductors exceed #6 Awg. Spacer SULT10SP is required if line conductors exceed #350 kcmil. Requires (1) SUCP1216 Coupler Kit. Kit provides coupling straps for both line and breaker troughs. Requires (2) SUCP1216 Coupler Kits. Kit provides coupling straps for both line and breaker troughs. Specification Chart #2 Line Troughs 240V AC max., 1 Phase or 3 Phase Stack Width Catalog Approximate Positions (Inches) Number Quantity Weight (lbs.) 2 20 SULT20 1 14 3 30 SULT30 1 21 4 40 SULT40 1 28 5 50 SULT50 1 35 Line troughs are 12 high. Will not accommodate Phase Blocks. Specification Chart #3 Breaker Troughs Stack Width Catalog Approximate Positions (Inches) Number Quantity Weight (lbs.) 2 20 SUBT20 1 24 3 30 SUBT30 1 36 4 40 SUBT40 1 48 5 50 SUBT50 1 60 Use Siemens Type QP circuit breakers. Breakers not included. Height is 16. Specification Chart #4 Phase Blocks 240V AC max., 1 Phase or 3 Phase Number of Catalog Wire Range Take-off Lugs Number Quantity Approximate Wt. (lbs.) Line Load 3 SUPB3 1 1 3/8 x 16 Stud #6 - #4/0 6 SUPB6 1 1 3/8 x 16 Stud #6 - #4/0 12 SUPB12 1 2 3/8 x 16 Stud #6 - #4/0 Requires separate line lug kit. 5

Selection and Specifications Line Terminals / End Walls and Coupling Kits / Accessories Line Terminals (Use Specification Chart #5). Knowing the size and quantity per phase of the line conductors, select and spec these from Specification Chart #5. Line terminals come in kits of 4 terminals each. One kit will supply line terminals for 3 phase legs and neutral. End Walls (Use Specification Chart #6) NOTE: Each installation MUST have an end wall kit! The kit provides end walls for each end of the line and breaker troughs. (4 end walls). Use Specification Chart #6. Coupling Kits Specification Chart #6) When more than one line trough is needed to support the number of meter stacks on a job, or when a line trough spacer is required, coupling straps are required to connect the troughs. Use Selection Chart #2 footnotes 3 and 4 to determine quantity of coupling kits required. Each kit provides one strap for line trough and one strap for breaker trough. Spec from Specification Chart #6. Line Trough Spacer Kits Specification Chart #6) In some applications, the first phase block may be too close to the end wall of the line trough to provide proper wire bend space for the line conductors being used. Selection Chart #2 footnotes 1 and 2 will show when spacer kits are required. Tenant Circuit Breakers Each meter position in use requires a tenant circuit breaker. Use standard Siemens Type QP circuit breakers from the Speedfax Catalog. Specification Chart #5 Line Terminals Catalog Approximate Wire Range Number Quantity Weight (lbs.) (1) #6-350 kcmil SULK1350 1 1.00 (1) #4-500 kcmil or (2) #1/0-250 kcmil SULK1500 1 1.00 (2) #2-500 kcmil SULK2500 1 2.00 Quantity 1 Package = 4 Lugs. Specification Chart #6 End Wall and Coupling Kits Catalog Approximate Item Number Quantity Weight (lbs.) End Wall Kit Contains 4 end walls; 2 for line trough and 2 for breaker trough SUEW1216 1 7.00 Coupling Kit Contains 2 coupling straps; 1 for line trough and 1 for breaker trough SUCP1216 1 1.00 Specification Chart #7 Accessories 6 Catalog Approximate Item Number Quantity Weight (lbs.) Spacer 10 spacer for use with line trough to provide wire bend space where required SULT10SP 1 7.00 Meter Cover SUMCVR 1 2.00 Blank Position Cover SUMBCVR 1 2.00 Plastic Meter Cover (Ring Type) WSX087M 1 0.10 Breaker Filler Plate QF3 50 1.00

Meter Sockets / Load Centers Product Descriptions Meter Sockets: Design / Performance Features Steel enclosures are fabricated from 16, 14 or 12 gauge, commercial grade G90, zinc coated steel which is mill phosphatized to assure finish adhesion. Enclosure finish is a 2-3 mil organic polyester resin base. Finish is applied inside and outside to clean, and dry metal as an electrostatic charged powder to grounded assemblies. The finished assembly is then oven cured. Enclosure covers (except for ring style sockets) are supplied with a 300 series stainless steel rotary latch with a slot for ribbon or wire seals and a 3/8 diameter hole for a padlock. Ring style sockets have an internal slide latch. Meter socket jaws are fabricated from high conductivity, tin plated, copper alloy. Insulating jaw support blocks are fabricated from a high impact, non-tracking thermoset polyester. Meter socket connectors are fabricated from extruded high conductivity aluminum for lay-in style with either steel (100 ampere) or extruded aluminum (150 and 200 ampere) lug tops. Choice of top endwall options hub openings, closure plates, blank endwalls, hub installed. Complete selection of accessories including hubs, fifth jaws, and meter opening covers. Safety guide reduces chance of accidental contact with energized line jaws during installation or removal of meter or cover. Aligns meter in socket. Performance Engineered Meter Sockets Siemens offers a complete line of single and multiple meter sockets encompassing ring and ringless types in both normal duty and heavy duty construction. Sockets are available to satisfy the mounting requirements for both self-contained and transformer rated meters. Meter Sockets A meter socket is an enclosed device which has jaws to accommodate the matching blade terminals of an S base watthour meter and has connections for terminating the circuit conductors. Siemens offers single-position sockets for one meter or multiple-position sockets for two or more meters. Multipleposition sockets may be fabricated as one complete unit with two or more socket positions, or fabricated as one or more separate socket positions with removable sidewalls, and coupling straps for ganging into a multiple position socket assembly. Ring Type Meter Sockets A ring type meter socket has a socket curl for use with a sealing ring which holds the watthour meter in place. The socket curl is an integral part of the meter socket cover. The cover may be a latch type, secured in place by a latch; or a cross bar type, secured through the cross bar. Ringless Type Meter Sockets A ringless type meter socket has no provision for a socket sealing ring but uses the cover to hold watthour meter in place. The cover is sealable by the utility. Meter Bypass A meter bypass permits changing or testing a meter without interrupting the service. Siemens offers two types of bypasses. Manual bypasses for ringless type meter sockets are factory installed. The lever type is used on 200 ampere devices (200 and 320 Amp Heavy Duty Ringless Socket have Jaw Release - Lever Bypass) and the horn type is used on 125 and 200 ampere devices. Load Centers: Siemens main lug 3-phase load centers are designed specifically for New York City. These panels comply with the New York City Electrical Code (Title B, Article 13, Chapter 30) bulletin 124 and are approved by the Bureau of Electrical Controls Advisory Board. These load centers are designed for use with Siemens circuit breakers. These panels are equipped with wide gutters to allow for wire bending and easier installation. Some features and benefits of the New York City Load Centers are: 3-phase main lug only Wide gutters - load centers over 100 amps; meets New York City Electrical Code; easier installation Dielectric testing - load centers over 100 amps are tested to meet New York City Electrical Code requirements. UL Listed - Eliminates inspection problems 7

Selection and Specifications Meter Sockets / Load Centers Con Ed and New York City Approved UL Listed Ring Type No Bypass Amps Std. Package Wire Accessories Cont. Volts Catalog Approx. Dimensions (Inches) Range Access Max. Duty A.C. Number Qty. Wt. Lbs. Length Width Depth Cu/Al Hub 5th Jaw 125 100 600 WSN152C 5 39.00 12 8 3-1/2 #8-2/0 UG-None Installed 125 100 600 WSN152CC 5 41.50 12 8 3-1/2 #8-2/0 1-1/4 Interch. Installed 125 100 600 WSN152CX 5 39.00 12 8 3-1/2 #8-2/0 WRX Provision Installed 200 160 600 WSS152C 1 14.00 15 11 4-3/8 #2-350 kcmil UG-None Installed 200 160 600 WSS152CX 1 11.50 15 8 4-3/8 #2-350 kcmil WRX Provision Installed Sealing ring not included. Dimensions shown are representative of outside box length, width & depth (+/-1/8 ) and do not include allowances for mounting bumps, endwalls, covers, hubs or hardware protrusions. Consult factory for specific details if required. 6th Jaw available, order WRX112FJ 3 o clock only. 5th Jaw at 9 o clock only. Ring Type, Unbussed, End Fed, Indoor, Insulated Groundable Neutral Amps Wire Accessories No. Dimensions (Inches) of Cont. Catalog Std. Approx. Range Coupling Pos. Max. Duty Number Pkg. Wt. Lbs. Length Width Depth Cu/Al 5th Jaw Strap Line #6-4/0 1 100 80 WSC150C 5 8.60 11-1/4 15-1/4 3-7/8 Load #8-2/0 Installed WSX008M Line #6-4/0 2 100 80 WSC250C 1 15.60 11-1/4 30-1/2 3-7/8 Load #8-2/0 Installed WSX008M Line #6-4/0 3 100 80 WSC350C 1 23.60 11-1/4 45-5/8 3-7/8 Load #8-2/0 Installed WSX008M Gang 2 of above with coupling strap Line #6-4/0 4 100 80 WSX008M and price accordingly. Load #8-2/0 WSX019 WSX008M Dimensions shown are representative of outside box length, width & depth (+/-1/8 ) and do not include allowances for mounting bumps, endwalls, covers, hubs or hardware protrusions. Consult factory for specific details if required. 5th Jaw at 9 o clock only. Ring Type, Bussed, End Fed, Outdoor, Bonded Neutral with 5th Jaw Amps No. Dimensions (Inches) Wire Range of Cont. Catalog Std. Approx. Pos. Duty Number Pkg. Wt. Lbs. Hub Length Width Depth Cu/Al Line #6-250 kcmil 2 100 WSN251CR 1 18.00 WRX 13-3/4 17-1/4 4-3/4 Load #8-2/0 Line #6-250 kcmil 3 100 WSN351CR 1 27.00 WRX 13-3/4 25-3/4 4-3/4 Load #8-2/0 Line #6-250 kcmil 4 100 WSN451CR 1 35.00 WRX 13-3/4 34-1/2 4-3/4 Load #8-2/0 Line #6-250 kcmil 5 100 WSN551CR 1 43.00 WRX 13-3/4 43-1/8 4-3/4 Load #8-2/0 3 Phase, 4 Wire 120/240V AC or 208Y/120V AC or 3 Phase, 4 Wire 240V AC Main Lug Only Dimensions (Inches) Catalog Number Amps 1 Spaces Max. CRT Length Width Depth Wire Range G1224ML310SCY 100 12 24 16-5/8 13-1/8 3-7/8 #4-2/0 G2430ML310SCY 100 24 30 24-1/8 13-1/8 3-7/8 #4-2/0 G2442ML315SCY 150 24 42 27-1/8 17-5/8 4 #4-3/0 G3042ML32SCNY 200 30 42 33-5/8 17-5/8 4 #4-250MCM G4242ML32SCNY 200 42 42 38-5/8 17-5/8 4 #4-250MCM Siemens Energy & Automation, Inc. Distribution Products Division Residential Products 5400 Triangle Parkway Norcross, GA 30092 1997 Siemens Energy & Automation, Inc. Siemens is a registered trademark of Siemens AG Bulletin RPSA-S0001(New) 5M0697SP Printed in U.S.A.