Product Brochure Fan coil units for suspended ceilings HyPower-Geko. Energy efficient Powerful Hygienic Low noise

Similar documents
Product Brochure Air Handling Units Compact COM4 series. HVAC solutions with energy recovery and unit automation

Product Brochure Compact Air Handling Units COM4 Series. Solutions have never been easier

PRODUCT BROCHURE Universal duct air filter DELBAG MultiClean. One system, many solutions

GEA filter program for turbo-machines. Gas turbines, compressors, motors and intake systems. Application brochures

DATA & FACTS Decentral Systems Comfort - Fan Coil Units Flex-Geko Comfort Edition. Flexible solution for any requirement

HVAC solutions with energy recovery and unit automation GEA COM4 plus GEA COM4 mini GEA COM4 top

MultiAir Premium. GEA Heat Exchangers / GEA Delbag Lufttechnik GmbH. GEA Compact Aerosol Separator > Top Filter Technology

KLIMA Active Chilled Beams

PRODUCT BROCHURE Cartridge-type Dust Collector DELBAG MultiJet. The system solution for dust

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

01 Overview 02 ecoo. 03 HybridChiller. 04 Re-cooler. 05 Circuit Separation. 06 Services. Contents 04/2018. Overview. 02 Cooling innovation

Swegon PACIFIC. Integrated climate beam

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

Ceiling swirl diffusers

Use. Installation. Key figures. Worth noting. linx industries chilled beams

DATA & FACTS Clean Rooms Fresh Heaven MAXX Fresh Heaven MAXX POWER. Laminar Air-Flow Units for Industrial Applications and Ceiling Installation

Total comfort control

Fan coil units MAJOR 2 CV/CH

PRODUCT BROCHURE Cartridge Dust Collector DELBAG EuroJet. Compact solution for dust and smoke

Heat pumps for swimming pools

Fan coil unit NBS 100/150

Air conditioning concepts for mini- and midibuses

COMPRESSORS MOBILAIR M 36/M 45. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 3.9 to 4.2 m³/min ( cfm)

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

42N. Room Fan Coils PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Simpified installation & large options choice

Water terminals From 360 to 1598 m 3 /h. From 1.3 to 9.6 kw. SysQuare. Chilled water cassettes. From 1.1 to 14.0 kw

CGAM. Air-cooled scroll chiller. Accessories. Customer benefits. Tracer CH530 Control. Main features. Energy saving options.

Ceiling swirl diffusers with perforated face plate

Swegon PACIFIC. Integrated climate beam

SCREW COMPRESSORS OIL-FREE

Swegon PACIFIC. Integrated climate beam QUICK FACTS KEY FIGURES

DATA & FACTS Unit Heaters MultiMAXX HB. Quick Selection and Fast Delivery

something new in the air Technical Bulletin

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

INTELLIGENTE DRUCKLUFT MADE IN GERMANY

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

Air-Cooled Liquid Chiller with integrated hydraulic module

Total cooling capacity kw Total heating capacity kw Features

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw

GEA Clean Rooms. Modules with laminar air flow for ceiling installation GEA Fresh Heaven j^uu GEA Fresh Heaven j^uu=mltbo.

modular multi intelligent, environmental and versatile

Modular fan coil unit model PS

Blue e+ chillers with the principle

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Elevator Technology. synergy. blue residential

COMPRESSORS MOBILAIR M 115. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 7.5 to 11.5 m³/min ( cfm)

Alfa Laval Optigo CS. Commercial air coolers - Slim line

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

Movement by Perfection. The Royal League in ventilation, control and drive technology. Modular System solution for AHU systems

Sapphire Horizontal Waterside Control Fan Coil Units

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

LTG Air Distribution. Product Overview

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

TSE Series Central Chillers

product Digital combustion technology Weishaupt oil burners, WL10 to WL40 ( kw) Information on compact burners

Albany RapidRoll 3000 Series The high performance doors for external and internal applications for the manufacturing industry. Technical data sheet

Outdoor system solutions

CXAM. Options. Accessories

Alfa Laval Optigo CD. Commercial air coolers - Dual discharge

Alfa Laval Optigo CD. Commercial air coolers - Dual discharge

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

Sociable, reliable, attractive: the newbie liked by everyone.

C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

How do we make city buses cleaner and more comfortable?

Product Catalog TSE Series Scroll Central Chillers

Simply a question of better measurement

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

synergy S1 Flexibility meets efficiency.

DKR Intelligent Digital AC Vector Drives 35 to 330 hp (26 to 245 kw)

Product Catalog TSE Series Scroll Central Chillers

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

LCU DX Efficient cooling with no loss of space

BRIZA 22 HYBRID HEATING & COOLING

Energy System Design for Optimized Power Management

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

COMFORT AIR CURTAIN. SensAir

Carisma The Ultra Quiet Fan Coil

SINAMICS GM150 IGCT version

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Your specialist for energy-efficient hydraulic solutions

Pedals for commercial and special-purpose vehicles. Robust Electronically controlled Flexible installation.

KOMPRESSOREN MOBILAIR M 43/M 50. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 4.2 to 5.0 m³/min ( cfm)

SO 61 to SO 126 Oil-free screw compressors (air or water cooled)

VXI Closed circuit cooling towers

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

Transcription:

Product Brochure Fan coil units for suspended ceilings HyPower-Geko Energy efficient Powerful Hygienic Low noise

Optimal climate: Hygienic. Efficient. Sustainable. The HyPower-Geko fan coil units generate a whisperquiet and comfortable feel-good climate at maximum energy efficiency and optimal air treatment. 2 PR-2014-0006-GB Subject to modification R2-09/2015

Economy and ecology in harmony The signs of the times are clear Investors, plant engineers, planners, and architects no longer ask whether but how they can enhance the degree of sustainability of their plants and building management systems. Buildings are unique objects. Location, size, construction quality, and increasingly, building engineering technology determine values and returns. Energy matters substantially gain in significance since buildings absorb about 40 % of the world energy consumption and produce 21 % of world-wide greenhouse gas emissions. Energy costs will increasingly become a second rent for users and residents. Where air conditioning is required for rooms and buildings, DencoHappel contributes to technological advances. We offer highly efficient air treatment and supply with the greatest possible reduction of energy consumption over the entire service life of the plants: This pays off in cents and euros, comfort and work productivity. In highly sensitive areas, such as clinical and clean room applications, our solutions reliably satisfy all international standards and achieve high rankings in the demanding classification of the Eurovent Compliance Committee for Air Handling Units. They furthermore set new standards for sustainability and perfect system integration in modern sport arenas, factory buildings, airport facilities, and swimming pools, as well as in offices, museums and hotels. We design we the most efficient demand-controlled solution for your requirements PR-2014-0006-GB Subject to modification R2-09/2015 3

Not just hot air, only full power The new dimensions of innovative air handling HyPower-Geko means: High Power Hygienic Power Hydronic Power Certified according to VDI 6022 HyPower-Geko The innovative fan coil unit in recirculating air mode convinces in three ways with an integral concept, that sets new standards: On maximum capacity with maximum energy efficiency and greatest possible demand on hygiene, HyPower- Geko performs individual air-conditioning at its best. Maximum power with precision Maximum cooling capacity at highest speed (25 kw) Powerful thanks to external pressure up to 150 Pa Modular construction system enables a flexible design, low-noise operation Certified hygiene conformity (VDI6022) Variable capacity stages: 2-pipe and 4-pipe Individual installation, e.g. in a discreet position in the false ceiling Comprehensive concept maximum use We optimize your total operating costs continuously and sustainably: highly-efficient fans are integrated in the unit and precisely tailored to our MATRIX control technology. Besides, our reliable software enables individual configuration and layout of your system. optimized total operating costs EC fan Integration in unit Compatibility of control system Software flexibility (individual operating points) 4 PR-2014-0006-GB Subject to modification R2-09/2015

Power is in the air Concentrated power, efficiency and comfort for a perfect room climate EC fans made by quality manufacturer ebm-pabst Maximum cooling and heating capacity with minimum electric power consumption - excellently awarded: EUROVENT energy label FCEER/FCOOP (class A) Condensate pump MaxiBlue Harmony all along the line: powerful, energy-efficient, low-noise and reliable owing to a new rotation-membrane principle. MATRIX control system Diverse control options in different stages of expansion - including: Plug and Play function, power-optimized operation and competent service with service tool. Compact controller CET-EC Equipped with auto and manual mode in 3 speeds: heating and cooling/only heating or cooling. Compatible with open/close valves. The fan is continuously controlled in auto mode. EC fan MATRIX controls CET-EC switch MaxiBlue condensate pump PR-2014-0006-GB Subject to modification R2-09/2015 5

Intelligent control technology Always the right idea for the right climate with the MATRIX Comprehensive control possibilities: Control functions in various expansion stages Bus interface to analog and digital devices Plug-and-play functionality Energy-optimized equipment operation Equipment ready to operate and highly competent service Global add-on modules LON connection Service tool available If requested as option, the proven MATRIX control unit will be integrated into the HyPower Geko at the factory. Thus, only completely tested equipment will be supplied to your construction site. The MATRIX is available in the configuration levels 3000 and 4000, in accordance with various applications. The model variants provide a 2-core MATRIX.NET bus system that allows communication among all MATRIX units. As a result, it is simple to implement daytime and nighttime switching actions, or to control pumps and collect error messages at a single point. MATRIX can also be connected to higher-level bus systems. MATRIX furthermore ensures an energy-optimized operation of the HyPower-Geko units. A coordinated switchover function, for example, prevents heating and cooling circulation systems from working against each other. With summer compensation, MATRIX takes the outside temperature influence into consideration and thereby prevents an energy-intensive climate control. Hardware and software are developed entirely at DencoHappel. As a result of close collaboration in the company, DencoHappel engineers can systematically adjust the control system to match every component and in turn optimally exploit the possibilities of the fan coil units. Service and support also benefit from this arrangement, and can rapidly and competently react whenever questions arise. Numerous additional global modules are available as function expansions of the standard local connections of the MATRIX control system, such as intra-group control units and clock modules, modules for activation control of chillers, expansion of analog or digital input and output signals, inputs and outputs for valves, and integration into a LON bus system in accordance with the LonWorks standard. All modules can be simply and easily integrated via the MATRIX.Net bus system. Furthermore, the service tool MATRIX.PC can be deployed for the parameterization, commissioning, maintenance and data recording of the MATRIX control system. 6 PR-2014-0006-GB Subject to modification R2-09/2015

Control panels for MATRIX 3000 and MATRIX 4000 MATRIX OP 30 with key MATRIX OP 31 with economy mode key Casing without display, pure white Recirculating air mode, IP 20 enclosureprotection class Setpoint temperature setting Speed selector switch for continuous/ automatic operation LED display of operation / malfunction / external control Integrated room-temperature sensor MATRIX OP 44 As for the OP31 control panel, but also with Toggle between heating/cooling/ automatic mode All control panels without display and optionally with protective cover Compact controller CET.ECH White casing, similar to RAL 9016 Recirculating air mode Protection class IP 30 Setpoint temperature setting Speed selector switch for continuous/ automatic operation Integrated room-temperature sensor Input via volt on-site floating contact by others Contact for external sensor Room frost protection MATRIX OP 50 without clock MATRIX OP 51 with clock Casing with display, pure white Recirculating air mode IP 20 class Operation with rotary navigator LCD display with plain-text display Status report by pictograms Integrated room-temperature sensor MATRIX.IR infrared remote control unit Functions like OP 44 control panel, however without operational / error messages without messages on ext. influence without integrated room sensor Black casing, similar to RAL 9004 LCD display 45 x 30 mm Transmission range about 20 m PR-2014-0006-GB Subject to modification R2-09/2015 7

HyPower-Geko Max. dimensions and weights Basic unit version A Without chamber for fans Free intake On-site filter must be provided Size Width* Depth Height mm mm mm 1 803 595 340 2 1108 595 340 3 1413 595 340 4 1833 595 340 Weight including water charge Size Max. (kg) 1 31 2 42 3 55 4 69 Basic unit version B With chamber for fans Without insulation of the fan chamber With integrated flat filter Duct and accessory connection possible Size Width* Depth Height mm mm mm 1 803 705 340 2 1108 705 340 3 1413 705 340 4 1833 705 340 Weight including water charge Size Max. (kg) 1 37 2 50 3 66 4 84 Basic unit version C With chamber for fans Like version B, but with interior acoustic insulation of the fan chamber Size Width* Depth Height mm mm mm 1 803 705 340 2 1108 705 340 3 1413 705 340 4 1833 705 340 Weight including water charge Size Max. (kg) 1 40 2 53 3 69 4 88 Extended condensate pan Optional for cooling operation Additional equipment Additional extended condensate pan at mounted valves and connection fixtures An additional 264 mm is then added to the entire width of the unit Basic unit in hygiene configuration On request Only available for authorized sales regions Heat exchanger cover plates on the front and back side to provide optical covering and protect the hydraulics and copper pipes from damage during installation Condensate pan, extended and powder-coated Increased distance between hydraulic system and electric terminal box * plus 264 mm when using the extended condensate pan 8 PR-2014-0006-GB Subject to modification R2-09/2015

HyPower-Geko Accessory items Optional selectable accessories Spare filters (G2 or G4) Flexible connection (intake or discharge) Air-intake plenum with round connectors DN 250 (insulated or non-insulated) Number of round connectors: Model size 1 = 3 pcs. Model size 2 = 4 pcs. Model size 3 = 5 pcs. Model size 4 = 6 pcs Seal cap DN 250 for round connector Transition piece for accessories Sound attenuator (intake/discharge) Suspension rail for ceiling mounting PR-2014-0006-GB Subject to modification R2-09/2015 9

Cooling Recirculating air 2-pipe system chilled water Air volume flow V at external pressure of 50 Pa in speed 3 and capacity stage 1 V Cooling capacity PCW 6 / 12 C Air intake 27 C / 46 % Capacity stage Sound power level at capacity stage 1 Motor data EC motor 1 ~ 230 Volt Size Speed Max. CS1 CS2 CS3 Intake Discharge Casing Max. Max. 1 1 340 m 3 /h 1.70 kw 2.30 kw 2.60 kw 41 db(a) 44 db(a) 36 db(a) 20 W 0.13 A 3 620 m 3 /h 2.70 kw 3.90 kw 4.40 kw 57 db(a) 60 db(a) 50 db(a) 100 W 0.72 A 5 920 m 3 /h 3.60 kw 5.50 kw 6.40 kw 67 db(a) 71 db(a) 59 db(a) 213 W 1.54 A 2 1 420 m 3 /h 2.20 kw 2.90 kw 3.20 kw 37 db(a) 40 db(a) 30 db(a) 19 W 0.18 A 3 970 m 3 /h 4.20 kw 6.00 kw 6.70 kw 56 db(a) 59 db(a) 46 db(a) 136 W 0.89 A 5 1,525 m 3 /h 5.90 kw 8.80 kw 10.10 kw 66 db(a) 70 db(a) 57 db(a) 296 W 2.09 A 3 1 630 m 3 /h 3.20 kw 4.30 kw 4.90 kw 45 db(a) 48 db(a) 36 db(a) 36 W 0.30 A 3 1,410 m 3 /h 6.00 kw 8.70 kw 10.00 kw 61 db(a) 64 db(a) 53 db(a) 258 W 1.84 A 5 2,090 m 3 /h 8.10 kw 12.10 kw 14.20 kw 70 db(a) 73 db(a) 61 db(a) 510 W 3.43 A 4 1 735 m 3 /h 4.00 kw 5.30 kw 6.10 kw 43 db(a) 42 db(a) 35 db(a) 34 W 0.29 A 3 1,735 m 3 /h 7.80 kw 11.10 kw 12.70 kw 61 db(a) 60 db(a) 51 db(a) 259 W 1.75 A 5 2,800 m 3 /h 10.70 kw 16.70 kw 19.70 kw 71 db(a) 72 db(a) 61 db(a) 591 W 3.76 A 10 PR-2014-0006-GB Subject to modification R2-09/2015

Heating Recirculating air 2-pipe system warm water Air volume flow V at external pressure of 50 Pa in speed 3 and capacity stage 1 V Thermal output PWW 70 / 50 C Air intake 20 C Capacity stage Sound power level at capacity stage 1 Motor data EC motor 1 ~ 230 Volt Size Speed Max. CS1 CS2 CS3 Intake Discharge Casing Max. Max. 1 1 340 m 3 /h 3.50 kw 4.50 kw 4.70 kw 41 db(a) 44 db(a) 36 db(a) 20 W 0.13 A 3 620 m 3 /h 5.60 kw 7.70 kw 8.20 kw 57 db(a) 60 db(a) 50 db(a) 100 W 0.72 A 5 920 m 3 /h 7.70 kw 10.90 kw 12.00 kw 67 db(a) 71 db(a) 59 db(a) 213 W 1.54 A 2 1 420 m 3 /h 4.50 kw 5.60 kw 5.70 kw 37 db(a) 40 db(a) 30 db(a) 19 W 0.18 A 3 970 m 3 /h 8.80 kw 11.90 kw 12.70 kw 56 db(a) 59 db(a) 46 db(a) 136 W 0.89 A 5 1,525 m 3 /h 12.50 kw 17.80 kw 20.00 kw 66 db(a) 70 db(a) 57 db(a) 296 W 2.09 A 3 1 630 m 3 /h 6.70 kw 8.50 kw 9.00 kw 45 db(a) 48 db(a) 36 db(a) 36 W 0.30 A 3 1,410 m 3 /h 12.70 kw 17.40 kw 19.30 kw 61 db(a) 64 db(a) 53 db(a) 258 W 1.84 A 5 2,090 m 3 /h 17.20 kw 24.60 kw 27.80 kw 70 db(a) 73 db(a) 61 db(a) 510 W 3.43 A 4 1 735 m 3 /h 8.10 kw 10.30 kw 10.90 kw 43 db(a) 42 db(a) 35 db(a) 34 W 0.29 A 3 1,735 m 3 /h 16.30 kw 22.20 kw 24.30 kw 61 db(a) 60 db(a) 51 db(a) 259 W 1.75 A 5 2,800 m 3 /h 23.60 kw 33.80 kw 38.00 kw 71 db(a) 72 db(a) 61 db(a) 591 W 3.76 A PR-2014-0006-GB Subject to modification R2-09/2015 11

Cooling or heating Change-Over operation Recirculating air 2-pipe system chilled or warm water Air volume flow V at external pressure of 50 Pa in speed 3 and capacity stage 1 V Cooling capacity PCW 6 / 12 C Air intake 27 C / 46 % Capacity stage Sound power level at capacity stage 1 Motor data EC motor 1 ~ 230 Volt Size Speed Max. CS1 CS2 CS3 Intake Discharge Casing Max. Max. 1 1 340 m 3 /h 1.70 kw 2.30 kw 2.60 kw 41 db(a) 44 db(a) 36 db(a) 20 W 0.13 A 3 620 m 3 /h 2.70 kw 3.90 kw 4.40 kw 57 db(a) 60 db(a) 50 db(a) 100 W 0.72 A 5 920 m 3 /h 3.60 kw 5.50 kw 6.40 kw 67 db(a) 71 db(a) 59 db(a) 213 W 1.54 A 2 1 420 m 3 /h 2.20 kw 2.90 kw 3.20 kw 37 db(a) 40 db(a) 30 db(a) 19 W 0.18 A 3 970 m 3 /h 4.20 kw 6.00 kw 6.70 kw 56 db(a) 59 db(a) 46 db(a) 136 W 0.89 A 5 1,525 m 3 /h 5.90 kw 8.80 kw 10.10 kw 66 db(a) 70 db(a) 57 db(a) 296 W 2.09 A 3 1 630 m 3 /h 3.20 kw 4.30 kw 4.90 kw 45 db(a) 48 db(a) 36 db(a) 36 W 0.30 A 3 1,410 m 3 /h 6.00 kw 8.70 kw 10.00 kw 61 db(a) 64 db(a) 53 db(a) 258 W 1.84 A 5 2,090 m 3 /h 8.10 kw 12.10 kw 14.20 kw 70 db(a) 73 db(a) 61 db(a) 510 W 3.43 A 4 1 735 m 3 /h 4.00 kw 5.30 kw 6.10 kw 43 db(a) 42 db(a) 35 db(a) 34 W 0.29 A 3 1,735 m 3 /h 7.80 kw 11.10 kw 12.70 kw 61 db(a) 60 db(a) 51 db(a) 259 W 1.75 A 5 2,800 m 3 /h 10.70 kw 16.70 kw 19.70 kw 71 db(a) 72 db(a) 61 db(a) 591 W 3.76 A 12 PR-2014-0006-GB Subject to modification R2-09/2015

Cooling or heating Change-Over operation Recirculating air 2-pipe system chilled or warm water Air volume flow V at external pressure of 50 Pa in speed 3 and capacity stage 1 V Thermal output PWW 70 / 50 C Air intake 20 C Capacity stage Sound power level at capacity stage 1 Motor data EC motor 1 ~ 230 Volt Size Speed Max. CS1 CS2 CS3 Intake Discharge Casing Max. Max. 1 1 340 m 3 /h 3.50 kw 4.50 kw 4.70 kw 41 db(a) 44 db(a) 36 db(a) 20 W 0.13 A 3 620 m 3 /h 5.60 kw 7.70 kw 8.20 kw 57 db(a) 60 db(a) 50 db(a) 100 W 0.72 A 5 920 m 3 /h 7.70 kw 10.90 kw 12.00 kw 67 db(a) 71 db(a) 59 db(a) 213 W 1.54 A 2 1 420 m 3 /h 4.50 kw 5.60 kw 5.70 kw 37 db(a) 40 db(a) 30 db(a) 19 W 0.18 A 3 970 m 3 /h 8.80 kw 11.90 kw 12.70 kw 56 db(a) 59 db(a) 46 db(a) 136 W 0.89 A 5 1,525 m 3 /h 12.50 kw 17.80 kw 20.00 kw 66 db(a) 70 db(a) 57 db(a) 296 W 2.09 A 3 1 630 m 3 /h 6.70 kw 8.50 kw 9.00 kw 45 db(a) 48 db(a) 36 db(a) 36 W 0.30 A 3 1,410 m 3 /h 12.70 kw 17.40 kw 19.30 kw 61 db(a) 64 db(a) 53 db(a) 258 W 1.84 A 5 2,090 m 3 /h 17.20 kw 24.60 kw 27.80 kw 70 db(a) 73 db(a) 61 db(a) 510 W 3.43 A 4 1 735 m 3 /h 8.10 kw 10.30 kw 10.90 kw 43 db(a) 42 db(a) 35 db(a) 34 W 0.29 A 3 1,735 m 3 /h 16.30 kw 22.20 kw 24.30 kw 61 db(a) 60 db(a) 51 db(a) 259 W 1.75 A 5 2,800 m 3 /h 23.60 kw 33.80 kw 38.00 kw 71 db(a) 72 db(a) 61 db(a) 591 W 3.76 A PR-2014-0006-GB Subject to modification R2-09/2015 13

Cooling and heating Recirculating air 4-pipe system chilled and warm water Air volume flow V at external pressure of 50 Pa in speed 3 and capacity stage 1 V Cooling capacity PCW 6 / 12 C Air intake 27 C / 46 % Capacity stage Sound power level at capacity stage 1 Motor data EC motor 1 ~ 230 Volt Size Speed Max. CS1 CS2 - Intake Discharge Casing Max. Max. 1 1 335 m 3 /h 2.10 kw 2.20 kw - 41 db(a) 44 db(a) 36 db(a) 20 W 0.13 A 3 610 m 3 /h 3.40 kw 3.80 kw - 57 db(a) 60 db(a) 50 db(a) 100 W 0.72 A 5 910 m 3 /h 4.70 kw 5.30 kw - 67 db(a) 71 db(a) 59 db(a) 213 W 1.54 A 2 1 400 m 3 /h 2.50 kw 2.70 kw - 37 db(a) 40 db(a) 30 db(a) 19 W 0.18 A 3 920 m 3 /h 5.10 kw 5.70 kw - 56 db(a) 59 db(a) 46 db(a) 136 W 0.89 A 5 1,460 m 3 /h 7.40 kw 8.40 kw - 66 db(a) 70 db(a) 57 db(a) 296 W 2.09 A 3 1 600 m 3 /h 3.80 kw 4.20 kw - 45 db(a) 48 db(a) 36 db(a) 36 W 0.30 A 3 1,340 m 3 /h 7.50 kw 8.40 kw - 61 db(a) 64 db(a) 53 db(a) 258 W 1.84 A 5 1,995 m 3 /h 10.20 kw 11.70 kw - 70 db(a) 73 db(a) 61 db(a) 510 W 3.43 A 4 1 710 m 3 /h 4.70 kw 5.10 kw - 43 db(a) 42 db(a) 35 db(a) 34 W 0.29 A 3 1,665 m 3 /h 9.60 kw 10.70 kw - 61 db(a) 60 db(a) 51 db(a) 259 W 1.75 A 5 2,695 m 3 /h 14.10 kw 16.10 kw - 71 db(a) 72 db(a) 61 db(a) 591 W 3.76 A 14 PR-2014-0006-GB Subject to modification R2-09/2015

Cooling and heating Recirculating air 4-pipe system chilled and warm water Air volume flow V at external pressure of 50 Pa in speed 3 and capacity stage 1 V Cooling capacity PKW 70 / 50 C Air intake 20 % Capacity stage Sound power level at capacity stage 1 Motor data EC motor 1 ~ 230 Volt Size Speed Max. CS1 CS2 - Intake Discharge Casing Max. Max. 1 1 335 m 3 /h 2.30 kw 3.30 kw - 41 db(a) 44 db(a) 36 db(a) 20 W 0.13 A 3 610 m 3 /h 3.50 kw 5.30 kw - 56 db(a) 60 db(a) 50 db(a) 100 W 0.72 A 5 910 m 3 /h 4.60 kw 7.40 kw - 67 db(a) 71 db(a) 59 db(a) 213 W 1.54 A 2 1 400 m 3 /h 2.90 kw 4.10 kw - 37 db(a) 39 db(a) 30 db(a) 19 W 0.18 A 3 920 m 3 /h 5.30 kw 8.00 kw - 56 db(a) 59 db(a) 46 db(a) 136 W 0.89 A 5 1,460 m 3 /h 7.30 kw 11.60 kw - 66 db(a) 70 db(a) 57 db(a) 296 W 2.09 A 3 1 600 m 3 /h 4.20 kw 6.20 kw - 45 db(a) 47 db(a) 36 db(a) 36 W 0.30 A 3 1,340 m 3 /h 7.50 kw 11.80 kw - 61 db(a) 64 db(a) 53 db(a) 258 W 1.84 A 5 1,995 m 3 /h 9.90 kw 16.10 kw - 69 db(a) 73 db(a) 61 db(a) 510 W 3.43 A 4 1 710 m 3 /h 5.10 kw 7.50 kw - 43 db(a) 42 db(a) 35 db(a) 34 W 0.29 A 3 1,665 m 3 /h 9.50 kw 15.00 kw - 60 db(a) 60 db(a) 51 db(a) 259 W 1.75 A 5 2,695 m 3 /h 13.40 kw 21.80 kw - 71 db(a) 72 db(a) 61 db(a) 591 W 3.76 A PR-2014-0006-GB Subject to modification R2-09/2015 15

DencoHappel is a globally operating company with great expertise in air treatment, air conditioning and filtration technology. Our nearest consulting and service teams will be glad to discuss ideas and develop creative and effective solutions with you. www.dencohappel.com