MicroTech III Water Source Heat Pump Wall-Mounted Room Temperature Sensors

Similar documents
DPS/MPS/RAH/RPS/SWP Space Sensor

TS , -850 Series TS , -850 Series TS-57031, TS

THC-2, THC-3, THCR-4, THCR-5. Enthalpy Control. General Instructions APPLICATION SPECIFICATIONS. ACCESSORIES None

TM-9100 Series Room Command Module

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

YCCS TE-6800 Series Temperature Sensors

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

TS Series TS Series

SEN and SEN Outdoor Air Temperature Sensors

BAPI-Stat 3 Room Sensor

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

Series 1000 Room Temperature Sensors, 1K Ω Platinum (375α) RTD (MBC/RBC/MEC/UC)

TSMN-90xxx Series TSMN TSMN TSMN Electronic Room Temperature Sensor General Instructions

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

MS Application. Features. Proportional Valve Actuator General Instructions

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

Installation and Maintenance Manual IM

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

CO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure

SAX Electronic Valve Actuator

TM-11x1 Series Room Temperature Module

5600 Series Power Operator Installation and Instruction Manual

TK-6024, TK-6124, TK-8024, TK-8124

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

VA-7450 Series. Electric Valve Actuators

AD592/592-10K Non-Room Units with a Junction Box, Weatherproof (WP) or Weather Tight (EU) Enclosure

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration

Sivoia QS Wireless Drapery Lite System

SE8300 Series Installation Guide 24 Vac Low Voltage

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

M9216 Series Electric Spring Return Actuators

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

VOC Room Sensor in the BAPI-Stat 3 Enclosure with Differential Ground Configuration

Optimized Idle Aftermarket Installation Kits On-Highway Truck Applications (P/N: )

General Description. Product Specification. Document Digital Temperature Interlock

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

poollux Power plx-pw60 & plx-pw100

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Dry Contact Closure Interface

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

ComfortPoint Programmable Lon, VAV/Unitary Controllers

Duct Temperature Sensors. Model TE-701 / 702

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

SCR Power Controllers

MF4E MF4E

2211 Series. Application. Features. One-Pipe Pneumatic Room Thermostats General Instructions SPECIFICATIONS

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

INSTRUCTIONS. Power Panel. Installation Instructions

Room Temperature Sensors Series to 20 ma

Electric Vehicle Charging Station

Damper Actuator Installation

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

BEAMER MODEL VDC Spotlight with joystick control panel MODEL VDC Spot/flood light with joystick control panel

Power Inverter 400 MW Owner s Manual

Versatile and Powerful

RA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System

ECONOMIZERS. 5/2012 Supersedes

General Information... 2

MA-5200 Series MA-5300 Series

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

INSTALLATION INSTRUCTIONS T-59 SPACE TEMPERATURE SENSOR WITH OVERRIDE & SETPOINT ADJUSTMENT

SAV Electronic Valve Actuator

E.S.P. Embedded Sensing Probes for Motor Brushes

LF Series At A Glance

SERIES 700 ANALOG ELECTRONIC CONTROLS

VOC Duct and Rough Service Sensor

Installation & Operation Manual

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

M670/M680BD MAGNALOCK SERIES Installation Instructions

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Powers TM Controls EA 338 Electronic Actuator

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

Instruction Manual. Q Series 2 Motor Control Modules - OEM

TANK MONITOR SYSTEMS DTM04 TANK MONITOR DTM08 TANK MONITOR DTM12 TANK MONITOR INSTALLATION AND OPERATION MANUAL

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

Products for Indoor Air Quality and Control

CP (Vdc) CP (Milliamp) CP (Slidewire)

MF-22xx3. Application. Features. Floating Valve Actuator General Instructions

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

ARTICLE BEGINNING SERVICE PRECAUTIONS

Alliance Towel Dispensing System. Operation Manual

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

230VAC Power Inverter 400W Owner s Manual

LED Downlight Ceiling Fixtures

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

GE Measurement & Control

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

Versatile and Powerful

Compact Low Pressure Sensor

Installation Instructions

Transcription:

Installation & Maintenance Data IM 955-1 Group: WSHP Part Number: 668997001 Date: June 2010 MicroTech III Water Source Heat Pump Wall-Mounted Room Temperature Sensors Sensor Kit P/N 669529001, 669529101 & 669529201 Sensor 669529101 (669529201 Not Shown) Sensor 669529001 2010 McQuay International 800.432.1342 www.mcquay.com

Table of Contents Introduction... 2 Specifications... 2 Notice... 2 Pre-Installation... 3 Wiring... 3 Mounting Location... 3 Installation...3-4 Wiring... 4 Testing... 5 Operating Modes... 6 Introduction Microtech III Wall Mounted Room Temperature Sensors provide electronic sensing of room temperatures at wall locations. All sensor models feature a thermistor (10kΩ), a green LED for unit status and tenant override button. Setpoint adjustment potentiometer, heat and fan mode switches are optional features (see Table 1, page 3). This manual includes installation instructions and general information for a Microtech III Wall Mounted Room Temperature Sensor. For installation and commissioning instructions and general information on a particular unit, refer to its model-specific installation manual. Specifications Thermistor resistance (10kΩ) (Conforms to Advance Thermal Products curve 2) Ambient Temperature Limits: Shipping and Storage: 40 F to 160 F ( 40 C to 71 C) Operating: 40 F to 140 F (4 C to 60 C) Humidity: 5 to 95% RH, noncondensing Locations: NEMA Type 1, Indoor only Connections: Color Coded Leads Sensor 669529101 (669529201 Not Shown) Sensor 669529001 Notice 2010 McQuay International, Minneapolis MN. All rights reserved throughout the world. McQuay International reserves the right to change any information contained herein without prior notice. The user is responsible for determining whether this product is appropriate for his or her application. The following are trademarks or registered trademarks of their respective companies. McQuay, MicroTech, and MicroTech III from McQuay International. Page 2 of 6 / IM 955

Table 1. MicroTech III Sensor Kits Water Source Heat Pump (10 kw) Sensor Kit P/N Tenant Override Button SPT Adj Pot Status LED Fan and Mode Switches 669529001 Yes No Yes No 669529101 Yes Yes Yes Yes 55 to 95 F (12 C to 35 C) 669529201 Yes Yes Yes Yes -3 to +3 F (-1.5 C to +1.5 C) Pre-Installation Inspection Visually inspect the carton for damages. If it is damaged, notify the appropriate carrier immediately. Open the carton and visually inspect the device for obvious defects. Return damaged or defective products. Required Installation Items Wiring diagram for MicroTech III Unit Controller Tools Appropriate screwdriver(s) for cover, terminals, and mounting screws Wire stripper/cutter The following only if wallboard mounting: Appropriate drill and drill bits Appropriate mounting screws and plastic anchors Wiring 3-lead NEC Class II low voltage wiring for temperature sensor 669529001, 5-lead for sensor 669529101 and 669529201. Notes: 1. Do not install the wire cables in the same conduit with power wiring. 2. Never apply external voltage of any type to any terminal or damage will result. 3. Do not exceed ratings of the device. This is a low voltage device: 4. Always use 22-gauge wire and never locate the room temperature sensor more than 250' from the unit: Wiring must be installed in accordance with the National Electrical Code and all local codes and ordinances, which can require the use of plenum rated cable or conduit. Mounting Location Locate the sensor on a wall where exposure to unrestricted air circulation represents the average temperature of the space. A common mistake is to mount the sensor too close to the supply air diffuser in a room. This causes short cycling of the air conditioning unit and large room temperature swings. Installation WARNING Hazardous Voltage! This equipment presents hazards of electricity Failure to read and follow these instructions can result in property damage, severe personal injury or death. 1. Turn off power at the main service panel by removing the fuse or switching the appropriate circuit breaker to the OFF position. 2. Remove the sensor cover by inserting a screwdriver and gently twisting it in the slots on the sides of the wall temperature sensor (669529101 & 669529201 only). To remove the cover on sensor 669529001, loosen two allen-wrench set screws located on the underside of the cover. Note: Mount the sensor five feet above the floor. Do not mount the sensor on an outside wall, in direct sunlight, behind a door, or in an area affected by a vent or duct. 3. Place the wall sensor mounting base against the wall where the sensor where be located. Using the base as a template trace the mounting holes onto the wall. 4. Drill a 3/16" hole at each mounting hole mark. 5. Insert wall anchors into mounting holes and tap in to the wall surface. 6. Feed wires through the back of the sensor mounting base and align sensor mounting holes with wall anchors. 7. Use supplied screws to secure sensor base to wall. IM 955 / Page 3 of 6

CAUTION Be certain that exposed portions of wires do not come in contact with each other 8. Connect stripped, labeled wires to matching terminals on the temperature sensor.. Refer to the appropriate Figure 2 or 3. 9. Tighten screws on terminal connections. Gently tug wire to check for secure connections. Confirm that each wire is connected to the proper terminal. 10. Seal the hole where the wire enters through the wall behind the temperature sensor, with non-flammable insulation or putty. 11. Replace cover on wall temperature sensor by snapping it in place. Note: Sensor 669529001 has two allen wrench set-screws on the underside of the sensor cover to secure it in place. Do not overtighten. 12. Turn on power to the system at the main service panel. 13. Test wall temperature sensor operation as described in "Testing" on page 5 Utility Box Mounting of Sensor 669529001 1. Feed the cable from the utility box. 2. Strip ¼ inch of insulation from the end of the wires. 3. Connect stripped, labeled wires to matching terminals on the temperature sensor base. See Figure 3. 4. Tighten screws on terminal connections. Gently tug wire to check for secure connections. Confirm that each wire is connected to the proper terminal. 5. Neatly store excess wire back inside the utility box. 6. Mount the sensor base to the utility box using two 6-32 5/8 inch flat head sheet metal screws. provided with the sensor. 7. Replace cover on wall temperature sensor by attaching the catches at the top of the cover to the top tabs on the sensor base. Secure the cover to the base by tightening the two allen wrench set-screws on the bottom of the sensor cover. Do not overtighten. Wiring Temperature Sensors 669529101 & 669529201 Note: All sensors have black (common), white (thermistor), and red (LED) wires. With the tenant override and/or set point adjustment option, a green wire is provided. The optional thermometer does not affect wiring. Figure 2. Temperature Sensor Wiring to MicroTech III Unit Controller Temperature Sensor 669529001 Figure 3. Temperature Sensor Wiring to MicroTech III Unit Controller Temperature Sensor Terminals Temperature Sensor Terminals MicroTech III Unit Controller TB1 Terminals MicroTech III Unit Controller TB1 Terminals Page 4 of 6 / IM 955

Testing Temperature Sensors 669529101 & 669529201 Cool Test 1. Slide Mode switch to Cool mode. 2. Adjust set temperature so it is 5 degrees below room temperature. 3. Air conditioning should come on within five (5) minutes. Status indicator may come on. 4. Adjust the set temperature 2 degrees above the room temperature and the A/C should turn off. There may be a fan delay on your system. Heat Test 1. Slide Mode switch to Heat mode. 2. Adjust the set temperature so it is 5 degrees above the room temperature. 3. Heat should come on within five (5) minutes. Status indicator may come on. 4. Adjust the set temperature so it is 2 degrees below the room temperature and the heat should turn off. There may be a fan delay on your system. Fan Test 1. Set room temperature so that unit is no longer heating or cooling the space. Wait for unit to cycle off. 2. Slide Fan switch to On position. 3. Indoor fan turns on. 4. Slide Fan switch to Auto position. 5. Indoor fan turns off. Timed Override Button Test 1. Using the BMS, change the room settings so the unit is in Unoccupied mode. 2. Press the room sensor mounted override push button for more than 3 seconds and less than 10 seconds. 3. Unit will resume Occupied operation until the override time expires ( as programmed in BMS). 4. Using the BMS, return the unit to regular schedule. Figure 4. MicroTech III Wall Sensor 669529101 (669529201 - Similar) Status LED (Green) 3.75" Mode Control Slide Switch 4.59" Temperature Sensor 669529001 Cool Test 1. Using the building automation system (BMS), adjust room cooling setpoint to 5 degrees below room temperature. 2. Air conditioning should come on within five (5) minutes. Status indicator may come on. 3. Using the BMS, adjust the set temperature 2 degrees above the room temperature and the A/C should turn off. There may be a fan delay on your system. Heat Test 1. Using the building automation system (BMS), adjust room heating setpoint to 5 degrees above room temperature. 2. Heating should come on within five (5) minutes. Status indicator may come on. 3. Using the BMS, adjust the set temperature 2 degrees above the room temperature and the A/C should turn off. There may be a fan delay on your system. Figure 5. MicroTech III Wall Sensor 0 to 10 K ohm Potentiometer Fan Control Slide Switch Tenant Override Momentary Push Button Switch 3.28" 4.5" IM 955 / Page 5 of 6

Operating Modes Temperature Sensors 669529101 & 669529201 Cool Mode In cool mode the MicroTech III wall-mounted temperature sensor controls the cooling system Troubleshooting Symptom No LED illuminated Remedy Check for 5 VDC at sensor; LED is dark when 5 VDC is not present Heat Mode In heat mode, the Microtech III wall-mounted Room Temperature Sensors controls the heating system. Auto-changeover Mode In this mode the Microtech III wall-mounted Room Temperature Sensors will automatically change from heat mode to cool mode, or vice versa. Operating Modes All Temperature Sensors Timed Override Press Override button for more than 3 but less than 10 seconds and Unit will return to Occupied operation until the override time expires ( as programmed in BMS). Unit turns on and off too frequently For Sensors 669529101 and 669529201 Only Sensor must be located as described in Mounting Location on page 3 System fan does not Verify wiring is correct come on properly See Fan Test on page 5 Fan runs continuously Check fan On/Auto switch, ON position runs indoor fan continuously Warranty All McQuay equipment is sold pursuant to its standard terms and conditions of sale, including Limited Product Warranty. Consult your local McQuay Representative for warranty details. Refer to Form 933-43285Y. To find your local McQuay Representative, go to www.mcquay.com. This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.mcquay.com. Products Manufactured in an ISO Certified Facility. 2010 McQuay International 800.432.1342 www.mcquay.com IM 955-1 / Page 6 of 6