Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Similar documents
Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Safety Relay Unit G9S

Safety Interlock Switches

A22NK. Key-type Selector Switches

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

Model Number Structure

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

Surface mounting, flush mounting, and DIN track mounting

Model Number Structure

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

General Purpose Relay

H3DS-X - Solid State Two-Wire Timer

Ordering Information. Text PCB Power Relay G5LE

Power Contactor with Mirror Contacts

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions. Ordering Information

D4BL. Guard Lock Safety-door Switch

Safety Interlock Switches

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

Type Terminal Coil Contact form Model

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Safety Control HR1S-AC. Safety Relay HR1S-AC

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Safety Limit Switch

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

SYSMAC Transistor Remote Module

Safety Switches & Operator Controls

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

Ordering Information. Text Surface-Mounting Signal Relay G6K

DPST-NO None 2 channels Auto-reset Inverse 24 VAC/VDC G9SB-2002-A 4 1 channel or 2

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

D4GL. Model Number Structure. Guard Lock Safety-door Switch. Model Number Legend. Switch. Operation Key

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Model Number Structure

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Clicks for Three Easily Discernable Positions

Transistor Remote Modules

D4GL. Environment-friendly Switch with Direct Opening Contacts. Guard Lock Safety-door Switch. Model Number Structure

D4BL. Guard Lock Safety-door Switch

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

D4DL. Locking Safety-Door Switch. Compact, Locking Safety Door Switch with Dual Key Entry. H Two types in the series: Mechanical-lock

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

CAUTION CM-SE CM-S21 CM-S41

A22TK Key-type Selector Switch with Direct Opening Mechanism

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Safety-door Switch. Ordering Information

General Purpose Relay

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

General Purpose Relay

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Manual Reset Limit Switch

Safety Relay Unit. Ordering Information. Ultra Slim Safety Relay

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

Model Number Structure

D4BS CSM_D4BS_DS_E_8_4

D4JL/D4JL-SK40 CSM_D4JL_D4JL-SK40_DS_E_10_2

Analog Output Terminal

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Hinged Safety Door Switch

Switching Power Supply

Mechanical Key Switch

Small Limit Switch D4V

Safety Guard Switching Unit G9SX-GS

Transcription:

Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00 a.m. until 5:00 p.m. Pacific Time to answer your technical questions and provide application assistance. Simply dial 1/888/510-4357 or 1/510/608-3400 and a support engineer will be happy to assist you. Information can also be obtained 24 hours a day via our Website at www.sti.com or www.omron.ca. Turn the page for detailed Product Information. USA Headquarters 6550 Dumbarton Circle Fremont, CA 94555-3605 Tel: 1/510/608-3400 Fax: 1/510/744-1442 Email: sales@sti.com www.sti.com Omron Canada, Inc. 885 Milner Avenue Toronto, Ontario M1B 5V8 Tel: 1/416/286-6465 Fax: 1/416/286-6648 Email: askomron@omron.com www.omron.ca

Safety Relay Unit G9S CSM_G9S_DS_E_2_1 Ideal for Safety Door and Emergency Stop Switch Circuits Two-pole, three-pole, and five-pole models are available. Basic Models and OFF-delay models are available Incorporates LED indicators for monitoring built-in relays. Finger-protection construction. Conforms to EN standards and certified by BIA. Both DIN track mounting and screw mounting possible (twopole models) Be sure to read the Safety Precautions on page 9. Model Number Structure Model Number Legend G9S-@@@@-@@@ 1 2 3 4 5 1. Contact Configuration (Safety Output) 2: DPST-NO 3: 3PST-NO 5: 5PST-NO 2. Contact Configuration (OFF-delay Output) 0: None 2: DPST-NO 3. Contact Configuration (Auxiliary Output) 0: None 1: SPST-NC Note: Please see Ordering Information below for the actual models that can be ordered. 4. Input Configuration None: 1-channel or 2-channel input possible 1: 1-channel input 2: 2-channel input 5. OFF-delay Time None: No OFF-delay T01: 1 second T015: 1.5 seconds T03: 3 seconds T04: 4 seconds T05: 5 seconds T06: 6 seconds T10: 10 seconds T30: 30 seconds Ordering Information Basic Models Number of poles Rated voltage Main contact form Number of input channels Model 2 24 VDC DPST-NO 2 channels G9S-2002 24 VDC 24 VAC 3 * 100 VAC 120 VAC 3PST-NO G9S-301 200 VAC 240 VAC 24 VDC 1 channel or 2 channels possible 24 VAC 5 * 100 VAC 120 VAC 5PST-NO G9S-501 200 VAC 240 VAC * Auxiliary contact is SPST-NC. 1

OFF-delay Models Number of poles 3 Rated voltage 24 VDC 24 VAC 100 VAC 120 VAC 200 VAC 240 VAC Main contact form 3PST-NO Note: Each model has an SPST-NC auxiliary contact. OFF-delay form DPST-NO Number of input channels 1 channel or 2 channels possible OFF-delay time 1 s 1.5 s 3s 4 s 5 s 6 s 10 s 30 s Model G9S-321-T01 G9S-321-T015 G9S-321-T03 G9S-321-T04 G9S-321-T05 G9S-321-T06 G9S-321-T10 G9S-321-T30 Specifications Ratings Controller Block Model Note: The above ratings are at an ambient temperature of 23 C. Contact Rated voltage Rated current Rated power consumption G9S-2002 24 VDC 66 ma±20% Approx. 1.6 W G9S-301 G9S-501 G9S-321-T@ 24 VDC 62.5 ma±20% Approx. 1.5 W 24 VAC 125 ma±20% 100 VAC 30 ma±20% 120 VAC 25 ma±20% 200 VAC 15 ma±20% 240 VAC 12.5 ma±20% Approx. 3 VA (60 Hz) 24 VDC 127 ma±20% Approx. 3 W 24 VAC 229 ma±20% 100 VAC 55 ma±20% 120 VAC 45.8 ma±20% 200 VAC 27.5 ma±20% 240 VAC 22.9 ma±20% Approx. 5.5 VA (60 Hz) 24 VDC 150 ma±20% Approx. 3.6 W 24 VAC 254 ma±20% 100 VAC 61 ma±20% 120 VAC 50.8 ma±20% 200 VAC 30.5 ma±20% 240 VAC 25.4 ma±20% Approx. 6.1 VA (60 Hz) Model G9S-301, G9S-501, G9S-321-T@ G9S-2002 Item Load Resistive load Inductive load Resistive load Inductive load Rated load Rated carry current 240 VAC, 3 A * 24 VDC, 3 A 240 VAC, 3 A (cosφ = 0.3) 24 VDC, 1 A (L/R=100 ms) 5 A * If the load is 5 A at 240 VAC, the durability will be 40,000 operations. 240 VAC, 5 A 24 VDC, 5 A 240 VAC, 3 A (cosφ = 0.3) 24 VDC, 1 A (L/R=100 ms) 2

Characteristics Item Model G9S-2002 G9S-301 G9S-501 G9S-321-T@ Operating time *1 50 ms max. 300 ms max. Response time *2 50 ms max. 100 ms max. Control circuit power supply voltage allowance 15% to +10% Insulation resistance (at 500 VDC) Dielectric strength Vibration resistance Shock resistance *1.Not including bounce time. *2. The response time is the time it takes for the main contact to open after the input is turned OFF. Includes bounce time. *3. These weights are for DC models. AC models are 200 g heavier. Durability Between control circuits and safety/auxiliary circuits Between safety circuits and auxiliary circuits Safety circuits Between control circuits and safety/auxiliary circuits Between safety circuits and auxiliary circuits Safety circuits Destruction 100 Ω min. 100 Ω min. 100 Ω min. 2,500 VAC (50/60 Hz, 1 min.) 2,500 VAC (50/60 Hz, 1 min.) 2,500 VAC (50/60 Hz, 1 min.) 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) Malfunction 10 to 55 to 10 Hz, 0.25-mm single amplitude (0.5-mm double amplitude) Destruction 300 m/s 2 Malfunction 50 m/s 2 Min. permissible load (P level) (reference value) Ambient operating temperature 24 VDC, 50 ma 25 to 55 C (with no icing or condensation) Ambient operating humidity 35% to 85% Terminal tightening torque 0.98 N m Weight *3 Approx. 180 g Approx. 365 g Approx. 550 g Approx. 580 g Mechanical durability Electrical durability 1,000,000 operations min. with a switching frequency of approx. 1,800 operations/h 100,000 operations min. at the rated load with a switching frequency of approx. 1,800 operations/h Note: The durability is for an ambient temperature of 15 to 35 C and an ambient humidity of 25% to 75%. 3

Connections Internal Connections G9S-2002 G9S-301 (24 VDC) G9S-301 (AC Model) G9S-501 (24 VDC) G9S-501 (AC Model) G9S-321-T@ (24 VDC) G9S-321-T@ (AC Model) OFF-delay timer OFF-delay timer 4

Dimensions G9S (Unit: mm) G9S-2002 Terminal Arrangement G9S-2002 92 13 23 T31 T11 T12 A1 PWR (orange) 10 T21 T22 A2 K1 (green) K2 (green) 7 4.6 dia. Twelve, M3 5.9±0.1 14 24 T32 52.5 13 23 T31 T11 T12 A1 47.5 101 max. 76 max. 90±0.3 5.6 T21 T22 A2 14 24 T32 42.5 4.6 2.3R 23 max. (22.5) * 111 max. 4.7 * This is an average value. G9S-301 Terminal Arrangement G9S-301 92 X1 T11 T12 B1 13 23 33 41 A1 PWR (orange) K1 (green) K2 (green) Eighteen, M3 5.9±0.1 Y1 T21 T22 PE 14 24 34 42 A2 X1 T11 T12 B1 13 23 33 41 A1 76 max. 61.2 Y1 T21 T22 PE 14 24 34 42 A2 7 56 68 max. 111 max. G9S-501 G9S-321-T@ Terminal Arrangement G9S-501 G9S-321-T@ 92 T11 T12 B1 X1 Y1 13 23 33 43 53 61 A1 PWR (orange) K1 (green) K2 (green) K4 (green) K5 (green) Twenty four,m3 5.9±0.1 Y2 X2 T21 T22 PE 14 24 34 44 54 62 A2 T11 T12 B1 X1 Y1 13 23 33 43 53 61 A1 76 max. 63 Y2 X2 T21 T22 PE 14 24 34 44 54 62 A2 7 10 80 91 max. 111 max. 5

Application Examples G9S G9S-2002 with 2-channel Limit Switch Input/Auto-reset Limit switch S1, S2 Feedback loop S1: Limit switch S2: Safety Limit Switch with direct opening mechanism (D4B-N, D4N, D4F) : Magnet Contactor Note: This circuit conforms to Safety Category 4. G9S-301 (24 VDC) with 2-channel Limit Switch Input/Manual Reset Limit switches S1 and S2 Feedback loop Starter switch S3 K3 K3 Open PLC input PLC output KM3 S1: Limit switch S2: Safety Limit Switch with direct opening mechanism (D4B-N, D4N, D4F) S3: Reset switch (momentary operation) : Magnet Contactor KM3: G3J Solid-state Contactor Note: This circuit conforms to Safety Category 4. 6

G9S-501 (AC Model) with 2-channel Limit Switch Input/Manual Reset Feedback loop Limit switches S1 and S2 Reset switch S3 K3 K3 Open K4 and K5 K4 and K5 S1: Limit switch S2: Safety Limit Switch with direct opening mechanism (D4B-N, D4N, D4F) S3: Reset switch (momentary operation) : Magnet Contactor Note: This circuit conforms to Safety Category 4. G9S-321-T@ (24 VDC) with 2-channel Limit Switch Input/Manual Reset Limit switches S1 and S2 Reset switch S3 K3 Open Feedback loop KM1 KM2 OFF-delay timer K3 K4 and K5 K4 and K5 Operation instruction Motor rotation OFF-delay time Operation instruction Motor controller S1: Limit switch S2: Safety Limit Switch with direct opening mechanism (D4B-N, D4N, D4F) S3: Reset switch (momentary operation) : Magnet Contactor Note: This circuit conforms to Safety Category 4 except for the OFF-delay output sections, which conforms to Category 3. 7

G9S-301 (24 VDC) with 2-channel Limit Switch Input/Auto-reset Limit switches S1 and S2 Limit switches S1 and S2 Feedback loop K3 K3 Open S1: Limit switch S2: Safety Limit Switch with direct opening mechanism (D4B-N, D4N, D4F) : Magnet Contactor Note: This circuit conforms to Safety Category 4. G9S-301 (24 VDC) with 2-channel Emergency Stop Switch Input/Manual Reset Feedback loop Emergency stop switch S1 Starter switch S2 K3 K3 PLC input PLC output KM3 S1: Emergency stop switch S2: Reset switch (momentary operation) : Magnet Contactor KM3: G3J Solid-state Contactor Note: This circuit conforms to Safety Category 4. 8

Safety Precautions Refer to the Precautions for All Relays and Precautions for All Relays with Forcibly Guided Contacts.!CAUTION Turn OFF the G9S before wiring the G9S. Do not touch the terminals of the G9S while the power is turned ON, because the terminals are charged and may cause an electric shock. Precautions for Correct Use Failure Detection for Slow-starting Power Supply When using a power supply with a long start-up time, if power is switched on while input has been closed the internal circuits will detect a power voltage error and the product will not operate. Apply the voltage to the product once the voltage has reached its rated level. Installation The G9S should be installed perpendicular on a vertical surface (i.e., vertically so that the markings can be read). Wiring Use the following to wire the G9S. Stranded wire: 0.75 to 1.5 mm 2 Steel wire: 1.0 to 1.5 mm 2 Make sure that each screw is tightened to a torque of 0.78 to 1.18 N m, or the G9S may malfunction or generate heat. External inputs connected to T11 and T12 or T21 and T22 of the G9S-301 must be no-voltage contact inputs. PE is a ground terminal. When a machine is grounded at the positive, the PE terminal should not be grounded. Mounting Multiple Units If the output current is 3 A or more, make sure that there is a minimum distance of 50 mm each between all adjacent G9S Units. (24-VDC models do not require this spacing.) Connecting Inputs When using more than one G9S Unit, do not connect the same switch to more than one G9S Unit. This applies to all input terminals. Incorrect T11 T12 50 mm min. T11 T12 Fuse Replacement (Three- and Five-pole Models) The power input circuit of the G9S includes a fuse to protect the G9S from damage that may be caused by short-circuiting. The fuse is mounted to the side panel. Use the following type of fuse as a replacement. Using a non-specified fuse can cause malfunction or burning. Fuse Littel Fuse 218.4 IEC127 approval, rated current 0.4 A Use a flat-blade screwdriver to remove the fuse cover. Be sure to turn OFF the G9S before replacing the fuse. Fuse Resetting Inputs When only channel 1 of the 2-channel input turns OFF, the safety output is interrupted. In order to restart when this happens, it is necessary to turn OFF and ON both input channels. It is not possible to restart by resetting only channel 1. Resetting Inputs During OFF Delay Time The G9S-321-T@ operates as follows according to the reset mode when the inputs are to be re-entered during the OFF delay time of the G9S-321-T@: For auto reset, after the OFF delay time has ended, the outputs will turn OFF, and then the outputs will turn ON again. For manual reset, after the OFF delay time has ended, the outputs will turn OFF, and then the outputs will turn ON again when the reset is input. Durability of Contact Outputs Relay with Forcibly Guided Contact durability depends greatly on the switching condition. Confirm the actual conditions of operation in which the Relay will be used in order to make sure the permissible number of switching operations. When the accumulated number of operation exceeds its permissible range, it can cause failure of reset of safety control circuit. In such case, please replace the Relay immediately. If the Relay is used continuously without replacing, then it can lead to loss of safety function. G9S G9S 9

Applicable Safety Category (EN954-1) All G9S-series Relays fall under Safety Category 4 of EN954-1 except the G9S-321-T. The G9S-321-T has an OFF-delay output block falling under Safety Category 3. The above is provided according to circuit examples presented by OMRON. Therefore, the above may not apply to all operating environments. The applicable safety category is determined from the whole safety control system. Make sure that the whole safety control system meets EN954-1 requirements. Wire the G9S-2002 for auto-reset. If either one of them is connected to a manual reset switch, EN954-1 requirements will not apply. Safety Category 4 of EN954-1 Wire the G9S-2002 for auto-reset. If it is connected to a manual reset switch, EN954-1 requirements will not apply. Apply 2-channel external input to the T11 and T12 terminals and T21 and T22 terminals through switches each incorporating a force-separation mechanism. If limit switches are used, make sure that at least one of them incorporates a force-separation mechanism. Refer to Application Examples and input a signal for the normally-closed contact of the contactor (i.e., input to X1 of the G9S-301, X2 of the G9S-501, or X2 of the G9S-321-T). Be sure to ground the PE terminal. If the relay is operating with DC, the power supply may be grounded instead. Certified Standards The G9S-301, G9S-501, G9S-321-T and G9S-2002 conform to the following standards. EN standards, certified by BIA: EN954-1 EN60204-1 Conformance to EMC (Electromagnetic Compatibility), certified by TÜV Product Service: EMI (Emission): EN55011 Group 1 Class A EMS (Immunity): EN61000-6-2 UL standards: UL508 (Industrial Control Equipment) CSA standards: CSA C22.2 No. 14 (Industrial Control Equipment) 10