MCD 200 Series Soft Starters

Similar documents
1.1 Caution Statements

Design Guide. VLT MCD 200 Soft Starter. Phone: Fax: Web: -

Contents. MCD 200 Design Guide. Contents

Section 0.0 Warnings... 2 Section 1.0

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

User Guide. Digistart CS. 7.5kW - 110kW (18A - 200A) 200V, 400V, 575V

Application example of a motor controlled by MCD100 and protected by a circuit breaker

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

Dimensions WxHxD [mm] Weight [kg]

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

SOLSTART Instruction Manual

RVS-DN Digital Reduced Voltage Motor Starter

ASTAT XB USER MANUAL. 1 Caution Statements

Design Guide. VLT Soft Start Controller MCD 100

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

USERS MANUAL MCD REMOTE OPERATOR

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

MAKING MODERN LIVING POSSIBLE. VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 500

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

RVS-AX Instruction Manual

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

RVS-DX Digital Reduced Voltage Motor Starter

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

AuCom - Soft Starters

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Starting Torque Limiter Type TCI (Soft Start)

DEVICE STATE/BYPASSED FAILURE OVERLOAD

CTi Automation - Phone: Fax: Web:

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Reduced Voltage Motor Starters

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

1 Phase electronic contactor (SC 1)

MCD 500 Operating Instruction. Safety 5 Warnings 5. Feature List 7 Type Code 8. Mechanical Installation 9 Dimensions and Weights 10

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Softstarters Softstarters

SOLUTIONS, not just products

Operating Instructions VLT Soft Starter MCD 500

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

CI-tronic Soft starters for Danfoss commercial compressor applications Type MCI 15C, MCI 25C, MCI 50CM-3 I-O

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

Softstarter Intelligent Controllers

Operating Instructions. VLT Soft Starter - MCD 500. Phone: Fax: Web: -

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Synergy EN product information


Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz


HPS2DB Serial Softstarter Operation Manual

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

For Operation in the Control Cabinet

ABB Softstarters The new PSS line from 3A to 515A

1. Caution Statements System Design Electrical Installation Adjustments Troubleshooting... 16

Reduced Voltage Motor Starters

Three-Phase Soft Starters

Softstarters Type PSS. Softstarters. General information

1.1. Reduced Voltage Motor Starters

SECTION MOTOR CONTROL

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Soft Starter - MCD500

Single & Three-Phase Soft Starters

Technical Data Sheets

Operating Guide. VLT Soft Starter MCD 600

Thermal overload relay TF65 and TF96

MCD Pump Application Module

SSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM

XM1 - Motor protection relay

MCD 500 Service Manual. Functional Tests 5 Power Circuit Test 5 Start Performance Test 5 Run Performance Test 6 Trip Messages 6 General Faults 10

Solid State Relays contactor with Integrated Fuse Type RGC1F

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

ACCESS Always replace the cover panel on the unit after gaining access to the electrical connections.

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Low cost, internally bypassed non optimizing soft starter

Hp V AC Current Rating [A] 230V AC 60 Hz

PCS compact soft starters

Application Description

Model Number Structure. Characteristics. Model Number Legend. Soft Starter. Applicable Motors. Accessories

AUCOM NORTH AMERICA. Complete range of motor starting solutions

Operating Instructions. Drives Solutions.

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

Technical Data Sheets

TECHNICAL DATA SHEET KVA UPS Systemss

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

Altistart 48 Y-Range Soft Start Controllers Installation Guide

ROBICON W120 enclosed drive

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

Reduced Voltage Motor Starters

Technical Data Sheets

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Thermal-magnetic Miniature Circuit Breaker 4230-T...

SD Series Non-Fused Load Switches

Electronic overload relay EF65, EF96 and EF146

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Model Number Structure

Features and Benefits. Control Features

Transcription:

MCD 200 Series Soft Starters AC motors often cause one or more serious problems during startup acceleration. MCD 200 Series electronic soft starters control motor current to provide a smooth start. When is the MCD 200 the correct fit for your application? Anytime one or more of the following apply: High starting current, often causing an unacceptable load on the AC line Shock load on gear and other transmission elements, causing unnecessary wear on mechanical parts Fast acceleration and deceleration, causing unstable process conditions (e.g., in conveyors) Utility regulations prohibit line-starting of motors The Danfoss MCD 201 and 202 soft starters are the optimum solution to all these problems for AC motors ranging from 10-200 HP. Unlike traditional solutions, the MCD 200 soft starters offers a wide range of benefits for motor and equipment operation as a whole, including: Flexible control of starting current and torque Smooth control of current and voltage without any steps or transients Frequent start/stop operation without mechanical damage Flexibility to changes in the start conditions, increasing flexibility in the application Soft stop control for extending the motor deceleration time Easy-to-Use Interface The built-in potentiometers allow setting of parameters for simplified setup and easy operation. The dedicated remote operator kit accessory provides remote access to parameters, LED display, and monitoring of motor current. Working Principle Motor voltage is controlled by means of a phase cut principle. Two thyristors in each phase perform the power switching, enabling the starter to handle high starting torque and frequent starts/stops. Current transformers measure the motor current, providing feedback for constant current control of motor starting and also for numerous motor and application protection functions. MCD 201 and MCD 202 soft starters share a common power and mechanical design, but offer different levels of functionality. MCD 201 soft starters provide TVR (Timed Voltage Ramp) starting and stopping control and are designed for use with an external motor protection device. MCD 202 soft starters provide Current Limit starting control, TVR soft stop and include a range of motor protection functions. MCD 200 Series soft starters include an integral bypass function that bypasses the soft starter SCRs during run. This minimizes heat dissipation during run and makes the MCD 200 suitable for installation within non-ventilated enclosures without the need for an external bypass contactor. Common Functionality and Features 200 440 or 200 575 VAC 50/60 Hz supply voltage 10 150 HP @ 480 VAC; 15 200 HP @ 575 VAC Internal SCR bypass contactors allow installation within motor control enclosures with no need for extra ventilation of external bypass contactors Cover larger HP motors IP20 (up to 100 amps); IP00 (above 100 amps) Smaller than most comparable soft starters Equal functionality to market leaders, but with superior communication options Easy DIN rail mount for sizes up to 40 HP 2-wire or 3-wire start/stop control; programmable via 3 rotary switches Reset push button Ready and run (on, off or flashing) LED status indicators Options: Modbus module for serial communication Remote operator kit MCD PC software can be used for networks of up to 99 soft starters (each soft starter connected to the network requires a Modbus module or a remote operator kit) 142 1.800.432.6367

Features Concept Start/stop Adjustments Protection Outputs Optional Remote Operator Optional Network Functionality MCD 201 MCD 202 Physically compact starter providing basic soft start and stop functionality 3 adjustments: Timed voltage ramp-up Adjustable initial torque Timed voltage ramp-down 1 output relay: Line contactor control Pushbutton control Starter status LED Trip code display Operational control Status monitoring Physically similar to MCD 201, but provides enhanced soft start and motor protection functionality in addition to all the most common soft start and soft stop features 8 adjustments: Current limit (250 450%) Current ramp-up (2 25 seconds) plus initial current (150 250%) Ramp down (1 20 seconds) Motor FLC (50 100%) Motor trip class (10, 15, 20) Maximum start time (0 20 seconds) Phase rotation protection Auxiliary relay function (trip, run) Motor overload (adjustable trip class) Excess start time Reverse phase rotation Motor thermistor input Shorted SCR no start Supply fault no start 2 output relays: Line contactor control Run contactor or trip function Pushbutton control Starter status LED Trip code display Motor current Motor current display Motor temperature display Operational control Status monitoring Performance monitoring 1.800.432.6367 143

MCD 200 Series Soft Starters Line Supply (L1, L2, L3): MCD 200-xxx-T4-xxx.. 3 x 200 VAC ~ 440 VAC (+10% / - 15%) MCD 200-xxx-T6-xxx. 3 x 200 VAC ~ 575 VAC (+10% / - 15%) Supply frequency (at start)... 45 Hz - 66 Hz Control Supply (A1, A2, A3): MCD 200-xxx-xx-CV1...24 VAC/VDC (±20%) MCD 200- xxx-xx-cv3... 110 240 VAC (+10% / - 15%) or...380 440 VAC (+10% / - 15%) Control Inputs: Start Terminal N1...Normally Open, 300 VAC max. Stop Terminal N... Normally Closed, 300 VAC max. Relay Outputs: Main Contactor Terminals 13 & 14...Normally Open 6 A, 30 VDC resistive / 2 A, 400 VAC, AC11 Programmable Relay Terminals 23 & 24... Normally Open 6 A, 30 VDC resistive / 2 A, 400 VAC, AC11 Environmental: Degree of protection MCD 200-007 to MCD 200-055...IP20 MCD 200-075 to MCD 200-110...IP00 Operating Temperatures... 14 F 140 F (-10 C +60 C) Humidity... 5% to 95% Relative Humidity Pollution Degree...Pollution Degree 3 Vibration...IEC 60068 Test Fc Sinusoidal 4 Hz 13.2 Hz: ± 0.04 in (±1 mm) displacement 13.2 Hz 100 Hz: ±0.0015 lb (±0.7 g) EMC Immunity: Electrostatic discharge...4 kv contact discharge, 8 kv air discharge Radio frequency electromagnetic field...0.15 MHz 1000 MHz: 140 db (µv) Rated impulse withstand voltage (Fast transients 5/50 ns)... 2 kv line to ground Rated insulation voltage (Surges 1.2/50 µs - 8/20 ms) 2 kv line to ground, 1 kv line to line Voltage dip and short time interruption...100 ms (at 40% nominal voltage) Short Circuit: Rated short circuit current MCD 200-007 to MCD 200-037...5 ka MCD 200-045 to MCD 200-110... 10 ka Heat Dissipation: During Start...10 Btu/hr / ampere (3 watts / ampere) During Run...<13.7 Btu/hr (4 watts) Standards Approvals: C...IEC 60947-4-2 UL / C-UL...UL508 CE...IEC 60947-4-2 CCC...GB 14048.6 EMC Emission: Equipment class (EMC)... Class A Conducted radio frequency emission...0.15 MHz 0.5 MHz: <90 db (µv) 0.5 MHz 5 MHz: <76 db (µv) 5 MHz 30 MHz: 80 60 db (µv) Radiated radio frequency emission... 30 MHz 230 MHz: <30 db (µv/m) 230 MHz 1000 MHz: <37 db (µv/m) This product has been designed for Class A equipment. Use of the product in domestic environments may cause radio interference, in which case the user may be required to employ additional mitigation methods. 144 1.800.432.6367

General Specifications Mechanical Installation mm (in) MCD 201/202 Din Rail Foot Mounting MCD 20x-007 ~ MCD 200-030 1.18 in. (30 mm) Yes MCD 20x-037 ~ MCD 200-110 Not available Yes Cable Size Ventilation The MCD 201/202 Soft Starter includes an integral bypass function that bypasses the soft starter's SCRs during run. This minimizes heat dissipation during run and makes the MCD 200 suitable for installations within non-ventilated enclosures, with no need for an external bypass contactor. 1.800.432.6367 145

MCD 200 Series Soft Starters MCD 201 Wiring Schematics Range MCD 201 soft starters provide TVR (Timed Voltage Ramp) starting and stopping control and are designed for use with an external motor protection device. Example 2 MCD 201 installed with motor protection circuit breaker and line contactor Example 1 MCD 201 installed with motor protection circuit breaker Example 3 MCD 201 installed with circuit breaker, overload and line contactor 1 6 A @ 30 VDC resistive / 2 A 400 VAC AC11 2 Main Contactor 146 1.800.432.6367

General Specifications MCD 202 Wiring Schematics Range MCD 202 soft starters provide current limiting control and TVR (Timed Voltage Ramp) soft stop, and include a range of motor protection features. Example 2 MCD 202 installed with system protection circuit breaker and line contactor Example 1 MCD 202 installed with system protection circuit breaker complete with shunt trip device 1 6 A @ 30 VDC resistive / 2 A 400 VAC AC11 2 Main Contactor 3 Auxiliary Relay Function = Trip (see parameter 8) 1.800.432.6367 147

MCD 200 Series Soft Starters MCD 201-007 ~ MCD 201-030 4.8 lb (2.2 kg) mm (in) MCD 202-007 ~ MCD 202-030 5.3 lb (2.4 kg) MCD 201-037 ~ MCD 201-055 8.8 lb (4.0 kg) mm (in) MCD 202-037 ~ MCD 202-055 9.5 lb (4.3 kg) 148 1.800.432.6367

Dimensions MCD 201-075 ~ MCD 201-110 13.5 lb (6.1 kg) mm (in) MCD 202-075 ~ MCD 202-110 15.0 lb (6.8 kg) 1.800.432.6367 149