LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

Similar documents
FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

N0N A 250V One-Time Class H Fuse

Electric vehicle auxiliary fuses 500 Vdc, A

6.3 mm reverse quick connect

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

BUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

BH-1 modular fuse blocks, 700 V, 400 A

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

UL Recognized power distribution blocks

PT Medium voltage fuses for potential and small power transformers

Bussmann series Quik-Spec Power Module Switch elevator disconnect

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

Low-Peak 600V Class RK1

Effective December 2015 Supersedes September 2013

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

FLQ4 4A 500V TD CT Midget Fuse. Descriptions 4A 500V TD CT MIDGET FUSE Time Delay Midget Fuse 4 Amp. Manufacturer Information

FLQ /2A 500V TD CT Midget Fuse. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Class J modular ferrule and knifeblade fuse blocks

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

up to 30A limited by conductor size Operating and storage temperature:

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

SW Tog DP 30A 120/277V Autogrd B&S WH

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

The easiest and fastest way to select and specify the right control circuit fuse

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

Volts: 600V Amps: up to 30A limited by conductor size Withstand: 200kA RMS Sym. Operating and storage temperature:

Fast-acting supplemental fuse. For superior protection, Bussmann recommends upgrading to Low-Peak Class CC fuses. See data sheet # 1023.

Compact Circuit Protector

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

The easiest and fastest way to select and specify the right fuse

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

20A-125V DPLX RCPT. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight. Long Description

6125FF Fast-acting subminiature fuses

4750 Recp Duplex 15A 277V 2P3W H/L BK. Features amperage rating. Description RECP DUPLEX 15A 277V 2P3W H/L BK

Industry s most comprehensive medium voltage circuit protection

Specification made simple for selective coordination in a compact size

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

R-Rated medium voltage fuses for motor circuit protection

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series

R-Rated medium voltage fuses for motor circuit protection

Edison modular fuse, vault application products

5 x 20mm Fuses S500 Series, Fast-Acting, Glass Tube

Coiltronics HCM1104 Series High current power inductors

Class gg/gl, 690Vac, 2 to 500 Amps, Sizes 000 to 3 NH Series

Coiltronics HCM0703 Series High current power inductors

Assembly not available for new installations.

CUBEFuse. CUBEFuse catalog numbers (amps)

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

ELF -LR current-limiting fuse

CC06H High I 2 t Chip 0603 size fuses

Leading the way in new innovative circuit protection

Direct-connected capacitor fuse

Kearney fuse links. Technical Data General. Effective March 2014 Supersedes December 2013

Compact Circuit Protector (CCP)

Recp Duplex 20A 250V 2P3W STR Swire WH

S505SC 5 x 20 mm Time-delay, axial lead ceramic tube fuses

The driving force behind innovative products and accessories

C308F 3 mm x 8.4 mm fast-acting, ceramic tube fuses for hazardous applications

S505SCH 5 x 20 mm Time-delay, high I 2 t, axial lead, ceramic tube fuses

TRBR20WBXSP 20A TR Comm WH Dup Rec. Features amperage rating 20. Material, Color, and Finish. Dimensions and Weight.

MPI2520 High Current, Low Profile, Miniature Power Inductors HALOGEN FREE

Varnished Cambric Tape 3/4"X60' Features. Material, Color, and Finish. Dimensions and Weight. Long Description. Manufacturer Information

Kearney fuse links. Technical Data General. Effective December 2013 Supersedes November 2009

561LVB 561LVB 4 Oct Box W/Bracket. Features. Dimensions and Weight. Description. Manufacturer Information. Taxonomies, Classifications, and Categories

24HR 30A SPST TM SW. Features. Long Description

Design Tests for the 38.0 kv ELSP Current-limiting Fuse per ANSI/IEEE C

Type BR thermal magnetic trip curve results

Two-position sidewall (horizontal) and cover (vertical) mounted loadbreak switches

K-Limiter high ampere Companion II fuse

Low voltage, branch circuit fuses

CCFL Transformers Cold cathode fluorescent lamp inverter transformers

1025HC Fast-acting, high current, surface mount ceramic tube fuses

Bussmann. Circuit Protection Solutions

A 120V 20A Gfci RCPT. Features. Dimensions and Weight. Description. Manufacturer Information PASS & SEYMOUR GTIN

4 Square Partition Square Cut Tile Wall 2 Gang Cover 2 1/8 Deep 1/2 to 1 RSD

38 kv Bay-O-Net Cartridge and Fuse Assemblies Certified Test Report

X-Limiter full-range current-limiting fuse

Uses, Certifications, and Standards Electrical Control and Instruments, Indoor/Outdoor EXTERNAL FEET, WALL standard UL 508, CSA C22.

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

A 120V BR GFI Recpt. Features. Material, Color, and Finish. Description

MS303DS MS-303 3P Man CNT Only. Features. Dimensions and Weight. Long Description

LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block

SPECIFICATION HIGH IMPACT RESISTANT THERMOPLASTIC

Compact Circuit Protector (CCP)

C310FH 3.1 mm x 10 mm Fast-acting, axial lead ceramic tube fuses

Compact Circuit Protector (CCP)

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

R6F30A1S R6F30A1S 1P 60A 600V Fuse BLK. Features. Long Description

Transcription:

3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com LKN200 200A 250V Super-Lag Fuse Link Bussmann Fuses Number Manufacturer Description per unit Product Category Features amperage rating 200 class H Voltage Rating 250 Descriptions Description Long Description Product Type special features Manufacturer Information Brand Bussmann Fuses GTIN 00051712132008 Manufacturers Part Number LKN-200 UPC 051712132008 LKN200 Bussmann Fuses 200A 250V Class H Replacable Link For Ren-200 0.0300 (lbs/each) Renewable & Non-Renewable 200A 250V SUPER-LAG FUSE LINK 200A 250V Class H Replacable Link For REN-200 Super Lag Renewable Link Interrupt Rating 10000 Amp (RMS Symmetrical) Taxonomies, Classifications, and Categories Category Description Fuses & Fuse Accessories Type Fuse Link, Renewable, Super Lag Packaging 5 Per each 0.03 Uses, Certifications, and Standards Application Industrial and Commercial Structures

Technical Data 1028 Supersedes March 2014 BUSSMANN SERIES REN (250V) and RES (600V) Renewable Class H size fuses 250V REN s (1-60 Amps) REN-1 REN-6 REN-15 REN-40 REN-2 REN-7 REN-20 REN-45 REN-3 REN-8 REN-25 REN-50 REN-4 REN-10 REN-30 REN-60 REN-5 REN-12 REN-35-250V REN quantity and weight REN 1 30 10 0.55 (0.249) REN 35 60 10 1.40 (0.634) * per carton. Description: Non-current limiting, renewable 250V (REN) and 600V (RES) Class H size fuses and fuse links (250V LKN and 600V LKS) for use in electrical systems where the available fault current is less than 10,000 amps and frequent outages dictate the economy of these renewable type fuses. NOTE: The 70-600 amp ratings of the REN and RES fuses are now discontinued. Suggested replacements are: REN; Use 250V FRN-R Class RK5 fuses (see data sheet No. 1020) RES; Use 600V FRS-R Class RK5 fuses (see data sheet No. 1018) Replacement fuse links for all 1-600A ratings (250V LKN and 600V LKS) will continue to be available to service the installed base of REN and RES fuses. Specifications: Ratings Volts REN 250Vac RES 600Vac Amps 1-60A Interrupting Rating 10kA RMS Sym. 600V RES s (1-60 Amps) RES-1 RES-6 RES-20 RES-45 RES-2 RES-8 RES-25 RES-50 RES-3 RES-10 RES-30 RES-60 RES-4 RES-12 RES-35 - RES-5 RES-15 RES-40-600V RES quantity and weight RES 1 30 10 0.18 (0.082) RES 35 60 10 0.36 (0.163) * per carton. Features These fuses are generally sized at the amp rating of non-inductive circuits and 300% for motor circuits. Recommended fuse blocks Part Description HM250 250V, 30 and 60A 1-, 2- and 3-pole open fuse blocks HM600 600V, 30 and 60A 1-, 2 and 3-pole open fuse blocks For details, see data sheet No. 10289.

Technical Data 1028 REN (250V) and RES (600V) Dimensions - in 250V REN 2" 0.56" 3" 0.81" 600V RES 5" 0.81" 5.5" 1.06" 1A to 30A 35A to 60A 1A to 30A 35A to 60A Replacement 250V REN and 600V RES fuse links 250V LKN Fuse link catalog s (amps) LKN-1 LKN-10 LKN-60 LKN-200 LKN-1-1/2 LKN-12 LKN-70 LKN-225 LKN-2 LKN-15 LKN-75 LKN-250 LKN-3 LKN-20 LKN-80 LKN-300 LKN-4 LKN-25 LKN-90 LKN-350 LKN-5 LKN-30 LKN-100 LKN-400 LKN-6 LKN-35 LKN-110 LKN-450 LKN-7 LKN-40 LKN-125 LKN-500 LKN-8 LKN-45 LKN-150 LKN-600 LKN-9 LKN-50 LKN-175-250V LKN Fuse link carton quantity and weight LKN 1 30 20 0.05 (0.02) LKN 35 60 20 0.20 (0.09) LKN 70 100 10 0.20 (0.09) LKN 110 200 5 0.25 (0.11) LKN 225 400 5 0.55 (0.25) LKN 450 600 2 0.32 (0.15) * per carton. 600V LKS Fuse link catalog s (amps) LKS-1 LKS-10 LKS-50 LKS-200 LKS-2 LKS-12 LKS-60 LKS-225 LKS-2-1/2 LKS-15 LKS-70 LKS-250 LKS-3 LKS-17-1/2 LKS-80 LKS-300 LKS-4 LKS-20 LKS-90 LKS-350 LKS-5 LKS-25 LKS-100 LKS-400 LKS-6 LKS-30 LKS-110 LKS-450 LKS-7 LKS-35 LKS-125 LKS-500 LKS-8 LKS-40 LKS-150 LKS-600 LKS-9 LKS-45 LKS-175 600V RES Fuse link carton quantity and weight LKS 1 30 20 0.05 (0.02) LKS 35 60 20 0.02 (0.09) LKS 65 100 10 0.02 (0.09) LKS 110 200 5 0.25 (0.11) LKS 225 400 5 0.55 (0.25) LKS 450 600 2 0.32 (0.15) * per carton. 2

REN (250V) and RES (600V) Technical Data 1028 Time-current characteristic curves average melt 250V REN (LKN Fuse links) Time in seconds 3

Technical Data 1028 REN (250V) and RES (600V) Time-current characteristic curves average melt 600V RES (LKS Fuse links) Time in seconds 4

REN (250V) and RES (600V) Technical Data 1028 The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Bussmann Division 114 Old State Road Ellisville, MO 63021 United States For Eaton s Bussmann series product information, call 1-855-287-7626 or visit: 2015 Eaton All Rights Reserved Printed in USA Publication No. 1028 BU-SB14109 December 2015 Eaton and Bussmann are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. Follow us on social media to get the latest product and support information. 5