mono-layer ACR High purity Reinforced 1-10 Excellent Fair mono-layer DD High purity Reinforced Excellent Excellent

Similar documents
Stability Axial Compression Technology Application Ordering Information

InertSustainSwift. Achieving separations faster than ever before

5 µm Preparative HPLC Columns

Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 )

STABILITY AND RELIABILITY: NEW APPROACHES IN PREPARATIVE HPLC COLUMN DESIGN

Technical Overview. Introduction

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Prep Flash TLC. Preparative Chromatography

Achieving separations faster than ever before

Totally Automated Method for the Determination of Sudan Dyes in Food via On-Line Filtration, SPE and HPLC Analysis

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

LEVONORGESTRELUM LEVONORGESTREL (May 2015)

YMC Phases Preparative Scale. YMC Europe GmbH Friederike Becker

Fixed Flow Splitter *

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve

Simplify your search for. You will find both PEEK-lined stainless steel hardware as well as standard ss column hardware at the below stockingstations.

Online sample cleanup on the Agilent 1290 Infinity LC using a built in 2-position/6-port valve

Flash Chromatography Column Guide Medicinal Chemistry Natural Products Proteins & Peptides

Determination of Sudan Dyes I IV in Curry Paste

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

Agilent G5632 Valve Kit Instructions

4001 Transesterification of castor oil to ricinoleic acid methyl ester

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

High Recovery Method of HybridSPE - Phospholipid for Cleanup of Biological Samples Prior to LC-MS Analysis

General Guide of Lubricants Recycle

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

Using the PSD for Backflushing on the Agilent 8890 GC System

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

DRAFT PROPOSAL FOR THE INTERNATIONAL PHARMACOPOEIA: CARBAMAZEPINUM - CARBAMAZEPINE

QuickSplit TM Flow Splitters

CLAVULANATE POTASSIUM (KALII CLAVULANAS) Revised draft proposed monograph for The International Pharmacopoeia. (February 2018)

Isolation/Purification. Drug Development. Drug Discovery

Application. Gas Chromatography June 1995

Revision of the Monograph on Estradiol Valerate. Draft Proposal for The International Pharmacopoeia (July 2018) DRAFT FOR COMMENTS

VERITY Purification Systems Build the perfect system to fit your research

Accuracy Starts Here. Agilent Captiva Filtration Selection Guide

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Technical Procedure for Gas Chromatography (GC-FID)

Chromatography. Consumables and Supplies. Brownlee Cartridge and Conventional Columns! Hydrogen Generators! Portable Gas Leak Detector!

GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method

DRAFT PROPOSAL FOR THE INTERNATIONAL PHARMACOPOEIA: CARBAMAZEPINUM - CARBAMAZEPINE

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Application Note. Author. Introduction. Energy and Fuels

Application Note. Authors. Abstract. Energy & Chemicals

Analyte Focusing in Elevated Temperature HPLC

Prodigy ICP Application Note: # 1039

DETECTORS Photo Ionization Detector - PID. Overview

Ultra Clean Gas Filters Reference Guide ULTRA CLEAN GAS FILTERS

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns

*Order ferrules separately. Outlet Splitter. Outlet Splitter 14898

Analysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA

S 1125 HPLC Pump System

The Only No Compromise

Thermo Scientific Dionex UltiMate 3000 Thermostatted Column Compartment

High-throughput protein aggregate analysis of monoclonal antibodies using a novel dual-channel UHPLC instrument

Quality-by-Design in Method Development. Mijo Stanic General Manager and Technical Director

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

Performance Characteristics of the Agilent 1260 Infinity II Bio-Inert LC

MET-Biodiesel Capillary GC Columns

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

[ CARE AND USE MANUAL ] WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION CONTENTS I. INTRODUCTION II. USING THE COLUMN III. CARE AND MAINTENANCE

URB '-carbamoylbiphenyl-3-yl cyclohexylcarbamate. DEA Reference Material Collection. Form Chemical Formula Molecular Weight Melting Point ( o C)

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

Filter solutions for Danfoss PAH, APP and CLP pumps

Adjustable Flow Splitter *

Instructions for Use SeQuant CARS Continuous Auto-Regeneration System for SeQuant SAMS Suppressors

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

Monolithic silica columns: benefits and applications of Chromolith HPLC columns. Dr. Rod McIlwrick Merck KGaA, Darmstadt

HIGH PRESSURE SWITCHING VALVES

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

Glass Columns for Laboratory and Pilot Scale Liquid Chromatography

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

DACLATASVIR DIHYDROCHLORIDE (DACLATASVIRI DIHYDROCHLORIDUM) Proposal for The International Pharmacopoeia. (May 2018)

Sample Pretreatment, Accessories

Competitive Comparison Maximize Performance and Minimize Maintenance with Agilent LC Spares

Beverage Grade Carbon Dioxide

Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS)

14 Chromatography Columns

Filter solutions for Danfoss PAH, APP and CLP pumps

SAMPLING CONTAINERS & HOLDING TIMES. Parameters Method Holding Time 8 Minimum Volume Water Sampling Water Soil Water Soil Container Preservative 9

Agilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet

Determination of Free and Total Glycerin in B100 Biodiesel

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!

Agilent G2855A Deans Switching System

NEW HPLC - SYSTEM LINE

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC

Simple Heart Cutting with Deans. Capillary Flow Technolgy. Simon Jones Applications Engineer

select adsorbent technology

Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems

Ultra High Performance Fittings. Fittings Connectors Kits

Supplementary Material

Comparison of LC/MS/MS and GC/MSD Analyses of Pesticide Residues in Food Products when Using the QuEChERS Sample Preparation Technique

Practical Steps in GC Troubleshooting

Agilent 1200 Series Manual Injector

ASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels

Organic Chemistry, 5th ed. Marc Loudon. Chapter 2 Alkanes. Eric J. Kantorows ki California Polytechnic State University San Luis Obispo, CA

Techniques for Improving the Reproducibility of GC Analysis

Transcription:

Extended ph range from 1-10 provide longer lifetimes with harsh mobile phases Novel bonding reduces residual silanols which cause peak tailing Polymer coated capsule type silica Excellent selectivity for polar compounds columns, manufactured by Shiseido Co., Ltd., Japan, distributed worldwide by Phenomenex, are durable, reproducible columns designed to eliminate secondary retention effects that lead to tailing peaks. A two-step synthesis is used: 1) surface coating of the base silica gel using a reinforced silicone polymer by vapor deposition, resulting in a homogenous monolayer, and 2) bonding of alkyl groups to the coated surface to shield any acidic silanols. This process provides excellent peak shape for acidic, basic and chelating compounds. Eight types of columns are available in sizes ranging from analytical to preparative. Material Characteristics Calculated Packing Particle Pore Pore Surface Carbon Bonded Phase Material Shape/Size Size Volume Area Load Coverage (μm) (Å) (ml/g) (m 2 /g) % (µmole/m 2 ) UG C18 Spher. 3, 5 120 1.0 300 15 1.5 UG C8 Spher. 5 120 1.0 300 10 2.8 UG C1 Spher. 5 120 1.0 300 5 6.9 UG Phenyl Spher. 5 120 1.0 300 7 2.3 UG CN Spher. 5 120 1.0 300 5 3.8 UG NH 2 Spher. 5 80 0.9 400 15 0.9 UG SCX Spher. 5 80 0.9 400 9 0.6 AG C18 Spher. 5 120 1.0 300 15 2.6 SG C18 Spher. 5 120 1.0 300 14 2.6 AG C8 Spher. 5 120 1.0 300 10 3.9 SG C8 Spher. 5 120 1.0 300 10 3.9 MG C18 Spher. 3, 5 100 0.9 250 15 MG- C18 Spher. 3, 5 100 300 15 2.7 ACR C18 Spher. 5 80 0.8 340 18 2.5 AQ C18 Spher. 5 80 0.9 300 11 1.2 DD C8 Spher. 3, 5 80 300 11 3.8 Ever since the first was introduced in 1987 (AG type), the product line has evolved in terms of the quality of the base silica gel as well as polymer coating technology (Table 1). Shiseido s columns have kept pace with the increasing demands for high throughput, low-level detection and analysis under harsh sample and mobile phase conditions. With qualities such as increased acid and alkaline resistance, improved control over retention and selectivity, chromatographers will find a variety of useful materials from which to select, packed in fast capillaries on up to preparative dimensions. Table 1 Performance Overview of Media Type Base Silica Gel Polymer Coating ph Range Separation Retention of Quality Polar Compounds AG Conventional grade Mono-layer 2-10 Good Fair SG High purity Mono-layer 2-9 Good Fair (metal content: <5 ppm) UG High purity Homogeneous 2-10 Excellent Fair (metal content: <5 ppm) MG High purity Controlled 2-10 Excellent Strong MG- High purity Reinforced 2-10 Excellent Excellent ACR High purity Reinforced 1-10 Excellent Fair DD High purity Reinforced 1.5-10 Excellent Excellent AQ High purity Reinforced 2-9 Excellent Excellent 102 Phenomenex

A Choice of 6 Different C18 Phases C18 MG and C18 MG- C18 MG employs a silica gel with a relatively large surface area to which a controlled amount of C18 phase is introduced. This makes it a well-balanced stationary phase in terms of its retention behavior towards polar and hydrophobic compounds. Especially noteworthy is its ability to separate polar compounds. The new C18 MG- offers an even higher level of silanol shielding, making it excellent for analysis of basic compounds under neutral conditions - a special advantage to LC/MS users. C18 UG120 The moderate hydrophobicity of C18 UG120 is recommended for those who wish to perform their analysis in a relatively short time frame. The nonpolar surface of C18 UG120 is especially suitable for eluting polar compounds rapidly and sharply. C18 ACR C18 ACR shows excellent durability to acidic mobile phases. t is recommended to those who are not satisfied with the performance of their columns under harsh acidic conditions. The phase shows similar retention properties to those of UG, but in addition, shows high steric selectivity that is analogous to polymeric phases. C18 AQ The C18 AQ phase was developed to retain highly polar compounds, and is useable in 100 % aqueous-based mobile phases. Column Selection By Application Parameters Recommended C18 Phase General-purpose MG-, MG Harsh Acidic Conditions ACR, DD Preparative Applications UG80 Fast Analysis MG-, MG S3, UG120 Acid Resistance ACR > DD > MG-, MG > AG > UG Alkaline Resistance MG-, MG > ACR > DD > UG > AG Column Pressure DD < UG < ACR < AQ < MG-, MG Polar Compounds AQ > DD > MG-, MG MG MG- App D 14167 Tricyclic Antidepressants Column: C18 MG Dimensions: As indicated Mobile Phase: 0.05 % TFA, Water/Acetonitrile (70:30) Temperature: 35 C Detector: UV @ 210 nm Sample: 1. Doxepin 3. mipramine 2. Desipramine 4. Nortriptyline 5. Amitriptyline App D 15489 Amitriptyline ph Comparison Column: C18 MG- S5 Dimensions: 150 x 4.6 mm Part No.: CH0-7623 Mobile Phase: ph 2: 20 mmol/l Phosphate buffer/acetonitrile (40:60) ph 7: 20 mmol/l Phosphate buffer/acetonitrile (40:60) ph 11.5: 50 mmol/l Pirolidine buffer/acetonitrile (40:60) Temperature 30 C njection Vol.: 5 μl Sample: Amitriptyline 0 5 Phenomenex 103

C18 ACR, Excellent Acid Resistance ph stability 1-10 Highly inert No release of impurities Excellent resolution A modified polymer coating technology led to C18 ACR. mproved acid resistance was obtained. The ACR column provides excellent performance with improved column life and resolution throughout a wide range of ph (1-10). Retention Maintained at Low ph Duration of Exposure to 2 % TFA, ph 1.0 hr Acid Resistance Test Cycle Conditions Column: ACR 5 μm C18 Dimensions: 150 x 4.6 mm Part No.: CH0-7303 Mobile Phase: A: 2 %TFA in Water (ph 1) B: 2 %TFA in Acetonitrile Gradient: B: 65 % (20 min) - 0 % (60 min) - 98 % (5 min) - 65 % (5 min) Temperature: 60 C njection: 7 µl Sample: 1. Uracil 2. Amyl Benzene C8 DD Good resistance to acid and alkali (ph 1.5-10) Great peak shape for basic compounds Wide selectivity range for hydrophobic and polar analytes Low backpressure and excellent durability The unique polymer coating and bonding method of the C8 group gives C8 DD (Double Durability) good acid and alkali resistance. Retention times are decreased for hydrophobic compounds, while polar compounds are retained. n addition column durability and the balance of surface polarity are improved. The high surface polarity and lower hydrophobicity, compared to C18 columns, make this product a good choice for rapid analysis of mixtures with diverse hydrophobicities. Tricyclic Antidepressants App D 15490 1 2 3 4 5 Column: C8 DD S5 Dimensions: 150 x 4.6 mm Part No.: CH0-7612 Mobile phase: 0.1 % HCOOH in Water/Acetonitrile (75:25) Temperature: 40 C Sample: 1. Doxepin 2. Desipramine 3. mipramine 4. Nortriptyline 5. Amitriptyline 104 Phenomenex

ORDERNG NFORMATON AG Series C18 AG 120 Å 5 μm CH0-3976 12503 150 x 4.6 ea CH0-3977 12504 250 x 4.6 ea C18 AG 120 Å Guard Cartridge CH0-3894 12410 10 x 4.0 2/pk SG Series C18 SG 120 Å 5 μm CH0-3941 12512 150 x 4.6 ea CH0-3942 12513 250 x 4.6 ea C18 SG 120 Å Guard Cartridge CH0-3893 12411 10 x 4.0 2/pk C8 SG 120 Å 5 μm CH0-3936 21513 150 x 4.6 ea CH0-3937 21514 250 x 4.6 ea CN SG 120 Å 5 μm CH0-3952 33513 150 x 4.6 ea CH0-3953 33514 250 x 4.6 ea NH 2 SG 80 Å 5 μm CH0-3946 34513 150 x 4.6 ea CH0-3947 34514 250 x 4.6 ea Phenyl SG 300 Å 5 μm CH0-3965 31523 150 x 4.6 ea CH0-3966 31524 250 x 4.6 ea C1 SG 300 Å 5 μm CH0-3968 32523 150 x 4.6 ea CH0-3969 32524 250 x 4.6 ea C8 SG 300 Å 5 μm CH0-3955 21523 150 x 4.6 ea CH0-3956 21524 250 x 4.6 ea C18 SG 300 Å 5 μm CH0-3960 12522 150 x 4.6 ea CH0-3961 12523 250 x 4.6 ea Preparative sizes also available for all AG and SG phases. MF Series MF C8 80 Å 5 μm CH0-3884 60521 50 x 4.6 ea CH0-3885 60522 100 x 4.6 ea CH0-3886 60523 150 x 4.6 ea MF Ph-1 80 Å 5 μm CH0-3887 60501 50 x 4.6 ea CH0-3888 60502 100 x 4.6 ea CH0-3889 60503 150 x 4.6 ea MF Ph-1 80 Å 5 μm Guard Cartridges CH0-3896 12437 10 x 2.0 5/pk CH0-3897 12436 10 x 2.0 2/pk CH0-3898 12417 10 x 4.0 5/pk CH0-3899 12416 10 x 4.0 2/pk CH0-3901 12440 20 x 4.0 2/pk UG Series C8 UG 120 Å 5 μm CH0-3827 70001 35 x 2.0 ea CH0-3828 70003 150 x 2.0 ea CH0-3831 71503 150 x 4.6 ea CH0-3832 71504 250 x 4.6 ea Phenyl UG 120 Å 5 μm CH0-3840 73503 150 x 4.6 ea CH0-3841 73504 250 x 4.6 ea CN UG 120 Å 5 μm CH0-3854 71001 35 x 2.0 ea CH0-3857 64501 35 x 4.6 ea CH0-3858 64503 150 x 4.6 ea CH0-3859 64504 250 x 4.6 ea C18 UG 120 Å 3 μm CH0-4831 69790 50 x 2.0 ea CH0-4832 69791 75 x 2.0 ea CH0-4833 69792 100 x 2.0 ea CH0-3878 61526 50 x 4.6 ea CH0-3880 61530 100 x 4.6 ea CH0-3881 61533 150 x 4.6 ea C18 UG 120 Å 5 μm CH0-3806 70701 35 x 1.0 ea CH0-3807 70703 150 x 1.0 ea CH0-3812 70501 35 x 2.0 ea CH0-3813 70503 150 x 2.0 ea CH0-3814 70504 250 x 2.0 ea CH0-3815 61501 35 x 4.6 ea CH0-3816 61503 150 x 4.6 ea CH0-3817 61504 250 x 4.6 ea CH0-3819 61514 250 x 10 ea CH0-3820 61521 35 x 20 ea CH0-3821 61524 250 x 20 ea CH0-3822 61532 50 x 30 ea CH0-3823 61534 250 x 30 ea C18 UG 120 Å Guard Cartridge CH0-3895 12412 10 x 4.0 2/pk C1 UG 120 Å 5 μm CH0-3850 63504 250 x 4.6 ea NH2 UG 80 Å 5 μm CH0-3864 75003 150 x 2.0 ea CH0-3867 62503 150 x 4.6 ea CH0-3868 62504 250 x 4.6 ea SCX UG 80 Å 5 μm CH0-3882 77003 150 x 4.6 ea CH0-3883 77004 250 x 4.6 ea C18 UG 300 Å 5 μm CH0-3875 70801 35 x 2.0 ea Ordering nformation (Continued) Cartridge Holders Part No. Mfr. No. Description Unit Price CH0-3902 EF4010 Holder for 10 mm cartridges ea CH0-3903 EF4020 Holder for 20 mm cartridges ea Phenomenex 105

Ordering nformation (Continued) MG Series C18 MG 100 Å 3 μm CH0-7137 90841 35 x 1.0 ea CH0-7138 90842 50 x 1.0 ea CH0-7139 90846 75 x 1.0 ea CH0-7140 90821 35 x 2.0 ea CH0-7141 90822 50 x 2.0 ea CH0-7142 90826 75 x 2.0 ea CH0-7145 90816 75 x 3.0 ea CH0-7146 90801 35 x 4.6 ea CH0-7147 90802 50 x 4.6 ea CH0-7148 90806 75 x 4.6 ea CH0-7150 90853 50 x 10 ea CH0-7151 90862 35 x 20 ea CH0-7152 90863 50 x 20 ea C18 MG 100 Å 3 μm Capillary Columns CH0-7295 90923 150 x 0.3 ea CH0-7296 90933 150 x 0.5 ea C18 MG 100 Å 3 μm Guard Cartridges CH0-7159 12301 10 x 2.0 2/pk CH0-7161 12305 10 x 4.0 2/pk C18 MG 100 Å 5 μm CH0-5839 90301 35 x 2.0 ea CH0-5840 90303 150 x 2.0 ea CH0-5841 90304 250 x 2.0 ea CH0-5837 90203 150 x 3.0 ea CH0-5838 90204 250 x 3.0 ea CH0-5833 90101 35 x 4.6 ea CH0-5834 90103 150 x 4.6 ea CH0-5835 90104 250 x 4.6 ea CH0-7153 90602 50 x 10 ea CH0-7154 90604 250 x 10 ea CH0-7155 90702 50 x 20 ea CH0-7156 90704 250 x 20 ea C18 MG 100 Å 5 μm Capillary Columns CH0-7297 90903 150 x 0.3 2/pk CH0-7298 90913 150 x 0.5 2/pk C18 MG 100 Å 5 μm Guard Cartridges CH0-7157 12497 10 x 2.0 2/pk CH0-7158 12496 10 x 4.0 2/pk ACR Series C18 ACR 80 Å 5 μm Acid Resistance (ph 1-10) CH0-7302 91101 35 x 4.6 ea CH0-7303 91103 150 x 4.6 ea CH0-7304 91104 250 x 4.6 ea CH0-7305 91301 35 x 2.0 ea CH0-7306 91303 150 x 2.0 ea CH0-7307 91304 250 x 2.0 ea CH0-7308 91501 35 x 1.0 ea CH0-7309 91503 150 x 1.0 ea CH0-7310 91504 250 x 1.0 ea C18 ACR 80 Å 5 μm Acid Resistance (ph 1-10) Capillary Columns CH0-7311 91913 150 x 0.3 ea CH0-7312 91933 150 x 0.5 ea C18 ACR 80 Å 5 μm Acid Resistance (ph 1-10) Guard Cartridges CH0-7299 12150 10 x 1.0 2/pk CH0-7300 12152 10 x 2.0 2/pk CH0-7301 12155 10 x 4.0 2/pk AQ Series C18 AQ 5 μm CH0-7380 92040 35 x 4.6 ea CH0-7381 92044 150 x 4.6 ea CH0-7382 92045 250 x 4.6 ea CH0-7383 92010 35 x 2.0 ea CH0-7384 92014 150 x 2.0 ea CH0-7385 92015 250 x 2.0 ea CH0-7386 92000 35 x 1.0 ea CH0-7387 92004 150 x 1.0 ea CH0-7388 92005 250 x 1.0 ea C18 AQ 5 μm Capillary Columns CH0-7389 92604 150 x 0.5 ea CH0-7390 92504 150 x 0.3 ea C18 AQ 5 μm Guard Cartridges CH0-7391 12170 10 x 2.0 2/pk CH0-7392 12180 10 x 4.0 2/pk MG- Series C18 MG- 100 Å 5 μm - Silanol Shielding (ph 2-10) CH0-7622 92528 35 x 4.6 ea CH0-7623 92532 150 x 4.6 ea CH0-7624 92533 250 x 4.6 ea CH0-7625 92516 35 x 2.0 ea CH0-7626 92520 150 x 2.0 ea CH0-7627 92521 250 x 2.0 ea CH0-7628 92503 35 x 1.0 ea CH0-7629 92507 150 x 1.0 ea CH0-7630 92508 250 x 1.0 ea C18 MG- 100 Å 5 μm - Silanol Shielding (ph 2-10) Guard Cartridges CH0-7631 12200 10 x 4.0 2/pk CH0-7632 12199 10 x 2.0 2/pk DD Series C8 DD 80 Å 5 μm - Double Durability (ph 1.5-10) CH0-7611 90980 35 x 4.6 ea CH0-7612 90984 150 x 4.6 ea CH0-7613 90985 250 x 4.6 ea CH0-7614 90960 35 x 2.0 ea CH0-7615 90964 150 x 2.0 ea CH0-7616 90965 250 x 2.0 ea CH0-7617 90940 35 x 1.0 ea CH0-7618 90944 150 x 1.0 ea CH0-7619 90945 250 x 1.0 ea C8 DD 80 Å 5 μm - Double Durability (ph 1.5-10) Guard Cartridges CH0-7620 12350 10 x 4.0 2/pk CH0-7621 12090 10 x 2.0 2/pk Cartridge Holders Part No. Mfr. No. Description Unit Price CH0-3902 EF4010 Holder for 10 mm cartridges ea CH0-3903 EF4020 Holder for 20 mm cartridges ea 106 Phenomenex

Ceramospher and chiral cd-ph Ceramospher Chiral Columns High-efficiency, pressure-stable ceramic-based materials Choice of normal or aqueous mobile phase conditions Enantioselectivity for acidic, basic and neutral chiral compounds High loadability combined with long column lifetimes Based on 5 μm 40 Å spherical sodium magnesium silicate particles, Ceramospher phases RU-1 and RU-2 are novel materials for chiral separations. Enantiomer resolution is accomplished on an ion-exchange adduct of the base clay material in combination with an optically-active metal complex (based on ruthenium). Ceramospher Phases RU-1. Used for normal phase separations of a wide variety of chiral compounds, typical mobile phases include: 1 % isopropanolamine or dimethylamine in alcohol (methanol or ethanol) for basic compounds, and 1 % acetic acid in alcohol for acidic compounds. Retention can be controlled by adding small percentages of hexane to these eluents. RU-2. Treating the base material with a hydrophobic agent imparts excellent stability under aqueous conditions. Water is typically combined with methanol or acetonitrile in the mobile phase. When the content of water in the eluent is 30 % or higher, the retention mechanism appears to be based on typical reversed phase partitioning; when water makes up 5 % or less of the eluent, separations appear to be based on normal phase partitioning. Because of the long lifetime expected, this material is well suited for preparative use. Chiral CD-Ph Columns Made of precisely classified high-purity silica, this versatile chiral stationary phase is modified with phenylcarbamated ß-cyclodextrin. Suitable for separation of basic, neutral, and amphoteric optical isomers Usable with both aqueous and non-aqueous mobile phases High durability High sample loadability App D 5237 App D 5236 Ketamine Column: Shiseido Ceramospher RU-1 Dimensions: 250 x 4.6 mm x 2 Part No.: CH0-3905 Mobile Phase: Triethylamine/Methanol (1:100) Temperature: 50 C Laudanosine α=2.22 Column: Shiseido Ceramospher RU-2 Dimensions: 250 x 4.6 mm Part No.: CH0-3907 Mobile Phase: Diethylamine/Water/Acetonitrile (0.1:10:90) Flow Rate: 0.5 ml/min Temperature: 50 C α=1.60 min Ceramospher and Chiral CD-PH Call Phenomenex for a complete listing of Ceramospher chiral applications. ORDERNG NFORMATON App D 13576 Atropine Column: Shiseido Chiral CD-Ph Dimensions: 250 x 4.6 mm Part No.: CH0-5862 Mobile Phase: 0.5 mol/l NaClO 4 /CH 3 CN (70:30) Flow Rate: 0.5 ml/min Temperature: 25 C Detection: UV @ 220 nm njection Vol.: 10 µl min Ceramospher and Chiral CD-Ph Chiral Columns Part No. Mfr. No. Dimensions (mm) Price RU-1 CH0-3904 50503 150 x 4.6 CH0-3905 50504 250 x 4.6 RU-2 CHO-3906 50603 150 x 4.6 CHO-3907 50604 250 x 4.6 Chiral CD-Ph CHO-5862 80054 250 x 4.6 N CH3 OCOCHCH2OH * 0 4 8 12 16 20 24 28 32 min See p. 108 for additional Chiral Stationary Phases. Phenomenex 107