Laboratory Exhaust Systems

Similar documents
Laboratory Exhaust Systems

Laboratory Exhaust Systems

Energy Recovery Laboratory Exhaust

Energy Recovery Laboratory Exhaust

Laboratory Exhaust Systems. Vektor -H High Plume

Tube Axial Inline Fans

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

2. Backward inclined / backward curved centrifugal wheel fans. 3. Axial / backward curved mixed flow impeller bifurcated fans.

HIGH VELOCITY FUME EXHAUST FANS

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

High Performance Axial Fans

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Tubular Centrifugal Fans

Air Measuring Products AMD AMS IAQ

Plenum Fans. Models APM and APH. Belt and Direct Drive

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Propeller Hooded Roof Fans

Mixed Flow Inline Fan Model EQB

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

High Performance Axial Fans

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

VCD-23. Flange Options. Size Limitations

TUBULAR CENTRIFUGAL INLINE FANS

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

Roof Upblast and Sidewall Exhaust

COMMERCIAL DUTY PLENUM FANS

Mancoolers Models MCY, MCB, MCP

LINEA Low Discharge Roof Exhausters

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

Direct Gas-Fired Heating

Inline Fans [ 14 ] * UL is optional and must be specified.

Gravity Ventilators. Models FGI and FGR. Fabra Hood Intake and Relief

VCD-23. Low Leakage CONTROL DAMPER

QMXTubular Mixed Flow Product Guide 1

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Introduction to Johnson Controls Dampers

HVAC Control & Balancing Dampers

Roof Upblast and Sidewall Exhaust

Propeller Upblast Roof Fans

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

Centrifugal Inline Fans

Centrifugal Inline Fans Models SQ and BSQ Direct and Belt Drive

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

READ AND SAVE THESE INSTRUCTIONS

Air Moving Solutions. MODULAR plenum fans

forward curved inline duct blowers

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

Inline and Roof Mounted Fans

Centrifugal Fans - M41

AMD-33 Air Measuring Station with VCD-33 Control Damper

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

DESIGN GUIDELINES FANS PAGE 1 of 7

HCD-230 Industrial Control Damper

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Centrifugal Fans - Series 21 & 41

Model VCD-43 Extruded Airfoil Blade Control Damper

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Centrifugal Plenum Fan

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN


VCD-23 Low Leakage CONTROL DAMPER

VAHU Vertical Air Handling Unit

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

Industry best 5 year fan housing warranty, 1 year motor warranty

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

SQUARE INLINE CENTRIFUGAL FANS

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

CEILING & INLINE/CABINET VENTILATORS

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Leading the way for clean air in the new millennium. S o u r c e C a p t u r e

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

Thermal Isolation. Break

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL

FXV/CXV & FXV3/CXV3 Layout Guidelines

Mixed Flow Inline Fan, Model MFSI

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

Need a. Bathroom Fan?

TURNING AIR INTO SOLUTIONS. COMPACT PLENUM FANS ECLFN ECLQN

SECTION AXIAL HVAC FANS

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

Transcription:

Laboratory Exhaust Systems Vektor -MH and Vektor -MD Mixed Flow High Plume and High Plume Dilution Blower August 2013

Vektor-MH High Plume and High Plume Dilution Blower Greenheck s Vektor-MH high plume and high plume dilution blowers are designed to efficiently exhaust laboratory fumes and odors high above any air intakes on the same or surrounding buildings. Utilizing a patented mixed flow wheel design, the space saving configuration of the Vektor-MH and -MD maximizes air movement with reduced sound and energy. Vektor MH and MD Benefits Complete system with single source supplier Conforms to standards and codes ASHRAE 45, ANSI Z9.5 and UL 705 AMCA Licensed performance () Bifurcated housing for safe and easy maintenance Minimal roof deck space No guy wires up to 125 mph wind speed (201 km/h) Vektor-MH and are listed for Electrical UL/cUL 705 File no. 40001 Patents Manufactured by Greenheck Fan Corp. under the following patent numbers: U.S. Patents: No. 7048499, 7320636, 7682231 Mexico Patents: No. 243465, 258949 China Patents: No. 01813109.3, 200580006160.6, 200580006162.5 Singapore Patents: No. 124106, 124135 Hong Kong Patent: No. 1110926, 1114659 Indian Patents: No. 253764 Other U.S. and Foreign Patents Pending Vektor-MH Typical Installations Hospital laboratories and isolation wards Biotech laboratories College and university laboratories Research facilities Pharmaceutical companies Vektor-MH High Plume with High Velocity Discharge Nozzle The Vektor-MH for high plume laboratory exhaust utilizes an engineered conical discharge to maximize the effective plume height. The Vektor-MH has a single fan capacity up to 60,000 cfm and 8 in. wg (28,317 l/s and 1,990 Pa) The nozzle has a smooth transition from fan to discharge minimizing pressure losses No abrupt changes in area maximizing fan efficiency Multiple discharge nozzles per fan size to customtailor discharge velocity and plume rise 3,000 ft/min. (15.2 m/s) minimum discharge velocity per ANSI Z9.5 2 High Plume Dilution with High Velocity Nozzle and Entrainment Windband The for high plume dilution entrains ambient air to assist in the dilution of contaminated laboratory exhaust. The has a single fan capacity up to 80,000 cfm and 8 in. wg (37,756 l/s and 1,990 Pa) Increased dilution and safety while maintaining effective plume height Higher nozzle velocity creates higher dilution percentage Windband focuses and promotes mixing of exhaust and entrained ambient air 3,000 ft/min. (15.2 m/s) minimum nozzle discharge velocity per ANSI Z9.5 Induced Flow Fan with AMCA 260 Sound and Air

Vektor-MH High Plume The Vektor-MH pulls hazardous exhaust air straight through the fan into an engineered and tested conical discharge. Multiple nozzles for each sized fan allow for the maximum plume height balanced with reduced energy requirements. Exhaust Flow Dilution with Increased Safety The with high velocity nozzle accelerates exhaust air entraining additional outside air diluting any odors or contaminants in the exhaust before exiting out the top of the windband. Up to 300% dilution of lab exhaust. Entrained Air Total Flow Windband High Velocity Nozzle Entrained Air Lab Exhaust Lab Exhaust Compact Footprint High Volume Applications Parapet Installations Airflow and Effective Plume Height The effective plume height is an important factor in designing exhaust systems servicing laboratories. The effective plume height needs to be high enough to avoid exhaust re-entrainment into the same or adjacent buildings. Fan discharge type, concentration levels and airflow volumes all affect the needed effective plume height. The effective plume height (h e ) is the physical height of the fan system (h s ) plus the plume rise (h r ). Plume rise is calculated using the Briggs equation below. The plume rise from an exhaust stack, with no hinged rain cap, can be calculated using the following equation*: h r = 3.0 x V x d / U h r = plume rise, ft (m) V = Stack exit velocity, ft/min. (m/s) d = stack diameter, ft (m) U = wind speed, ft/min. (m/s) * From ASHRAE Laboratory Design Guide, 2001 Consult ASHRAE Handbook - HVAC Application for detailed design considerations of building air intake placement hr 1 hr 2 he 1 hs he 2 Vektor high velocity discharge without re-entrainment Traditional low velocity stack or fan with re-entrainment 3

Vektor-MH and Value Added Features Belt or direct drive flexibility MH and MD models are available with belt or direct drive arrangements to suit owner / operator preferences. Direct drive configurations use an AMCA arrangement 2 for maximum motor bearing life and easy maintenance. Belt drive configurations have a 2.0 drive service factor with minimum of two belts maintaining the highest level of reliability. Bifurcated housing Keeps serviceable components safe and accessible by dividing the airflow and isolating drive components completely out of the contaminated airstream. Belt Drive Mixed flow wheel Specially configured blades move air with lower energy consumption and reduced sound generation. Additional blades on the back of the wheel create a vacuum, preventing contaminated exhaust from escaping though the shaft opening into the fan housing. Available with AMCA Spark C or B construction. LabCoat corrosion resistant coating Electrostatically powder coated with corrosion resistant Hi-Pro Polyester topcoat with zinc-rich epoxy primer, protects against a wide spectrum of acids, alkalies and solvents. Back pressure blades Hi-Pro Polyester LabCoat Cross Section Zinc-rich Primer (70% zinc) 4-6 mils Total Advanced Surface Preparation Base Steel Isolation damper Parallel airfoil blade dampers isolate individual fans from the plenum when not in operation. Slide out design allows for service and inspection of damper and actuators without entering into the confined, contaminated plenum. The damper s low leakage design prevents back spin of the wheel. Dampers are constructed for the exhaust system s pressure and volume. Bypass damper Opposed airfoil blade dampers provide for full airflow control throughout the damper s operating range. Dampers are sized specifically for volumes and pressures required on the application providing superior system control. Heavy duty construction up to 15 in. wg (3736 Pa). Factory provided and mounting available. Roof curb Reinforced heavy duty insulated roof curb provides full perimeter and cross support for multiple fan plenums up to 125 mph (201 km/h) windload without the use of guy wires. 4

Options and Accessories Inline Attenuating Silencer Attenuating Windband Attenuating Nozzle Attenuating options - Reduce total sound levels. No loss of discharge velocity. Tested as an assembly. Sure-Aire Sure-Aire airflow monitoring - Without invasive probes, provides airflow measurement accuracy within 3%. Stack extension For projects that require additional discharge height or effective plume height. Direct Drive 5 or Vektor-MH with Energy Recovery Single source energy recovery system (ERS) - Pre-engineered energy recovery system that uses 100% safe coil loop system. Contaminated exhaust and fresh air supply airstreams are always separated. The ERS system is matched to the Vektor system plus coil and filter pressure drops are automatically included in fan sizing. ERS

Greenheck Advantage With over 65 years of experience in the HVAC industry, Greenheck is the world s largest manufacturer of commercial, institutional and industrial air movement and control equipment. We provide cost-effective, valueadded solutions with facilities and representatives around the world. Value for Owners Finding solutions for unique applications Focus on energy saving solutions Safe serviceability AMCA Certified Products Reliability Ease of maintenance Value for Engineers/Architects Quick and accurate information Design flexibility Laboratory expertise Revit models AMCA Certified Products Computer Aided Product Selection - CAPS Value for Contractors Complete system available for easy installation Flexible on-time delivery Prior shipped curbs Troubleshooting / answering installation questions Complete fan system AMCA Licensed AMCA certified performance as a complete assembly including discharge nozzle and windband Performance testing of air movement, energy consumption, and sound levels Computer Aided Program Selection CAPS provides needed information for an informed decision and streamlines the design process Selection wizard filters models by features important to the project Size options presented for side-by-side comparison Sort sizes by criteria such as fan rpm, energy consumption, sound levels and effective plume height Full submittal information, drawings, weight, fan curves and component details, print, or PDF Revit and scaled AutoCad drawings are downloadable as configured. AMCA 260 Testing Revit Drawing CAPS Configuration Computational fluid dynamics model of a traditional low velocity exhaust stack Vibration Testing Vektor fans are vibration tested as a complete assembly and must pass AMCA 204 vibration standards - Belt drive - 0.10 in./s (2.5 mm/s) filter in. - Direct drive - 0.08 in./s (2.0 mm/s) filter in. Tri-axial accelerometers take measurements at the bearings in three planes Test results for each fan are stored as permanent record and are available upon request Single Source Supplier Manufacturer of the fans, wheels, housings, plenums, dampers, and coils All system components are designed and integrated for laboratory exhaust Control of the manufacturing process and maintaining high quality standards Single source responsibility 6

Vektor-MH and Performance & Configuration MH Fan Size 15 18 20 22 24 27 30 33 36 40 Inlet CFM Effective Plume Rise (h e ) (ft.) MD Fan Size Inlet CFM Discharge CFM Effective Plume Rise (h e ) (ft.) Min 2,000 22 Min 1,500 4,500 20 15 Max 6,500 34 Max 5,500 11,700 34 Min 2,500 23 Min 2,000 6,160 23 18 Max 9,000 39 Max 8,000 18,000 42 Min 3,500 26 Min 2,500 7,800 26 20 Max 11,000 43 Max 10,000 22,600 47 Min 3,500 26 Min 5,000 11,000 28 22 Max 13,500 45 Max 14,000 23,600 45 Min 4,500 28 Min 6,000 13,200 30 24 Max 17,000 47 Max 17,000 28,700 49 Min 6,500 32 Min 7,500 16,500 33 27 Max 20,500 52 Max 21,000 35,400 54 Min 7,000 33 Min 9,000 19,800 37 30 Max 25,000 56 Max 25,000 42,200 58 Min 9,000 37 Min 8,000 17,200 32 33 Max 30,500 62 Max 33,000 49,500 60 Min 9,500 37 Min 9,500 20,500 34 36 Max 37,000 70 Max 36,500 60,200 66 Min 13,000 40 Min 12,000 25,800 37 40 Max 60,000 91 Max 44,500 73,400 72 MH and MD performance certified is for installation type A, Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Minimum inlet CFM based upon ANSI Z9.5 minimum discharge velocity of 3,000 ft./min. (15.2 m/s) Plume rise calculation based upon 10 mph (16 km/h) crosswind (see page 3). 44 49 54 Min 14,000 30,200 43 Max 54,500 89,900 85 Min 17,500 37,600 47 Max 65,500 109,700 93 Min 21,000 45,300 51 Max 80,000 132,000 103 Configurations Fan Qty. Fan Only Inline Side-by-Side 1 1 1 x 1 2 2 x 1 3 3 x 1 4 4 x 1 2 x 2 5 5 x 1 6 6 x 1 3 x 2 3x1 Inline System 1x1 Inline System 2x2 Side-By-Side System Model Number Nomenclature 15 9 70 LV HPW Mixed Flow Wheel High Plume Dilution Fan Size 9 Belt Drive 2 Direct Drive % Wheel Width Vektor-MH 15 9 70 12 Mixed Flow Wheel High Plume Fan Size 9 Belt Drive 2 Direct Drive % Wheel Width Nozzle Size Nozzle Size Windband Type 7

Family of Lab Exhaust Systems Vektor HS SAVVE discharge nozzle technology Variable volume flow constant velocity discharge Centrifugal wheel Up to 24,000 cfm and 4 in. wg Vektor H High Plume Discharge Nozzle Centrifugal wheel Compact design / sealed airstream components Up to 24,000 cfm and 4 in. wg Vektor CD High Plume Discharge Nozzle with Entrainment and Dilution Centrifugal wheel Highest efficiency / easy service design Up to 120,000 cfm and 14 in. wg Vektor MH High Plume Nozzle Mixed flow wheel / bifurcated housing Compact design Up to 60,000 cfm and 8 in. wg Vektor-MS SAVVE discharge nozzle technology Variable volume flow constant velocity discharge Mixed flow wheel / bifurcated housing Up to 38,000 cfm and 8 in. wg Vektor MD High Plume with Entrainment and Dilution Mixed flow wheel / bifurcated housing Compact design Up to 80,000 cfm and 8 in. wg Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Prepared to Support Green Building Efforts P.O. Box 410 Schofield, WI 54476-0410 Phone (715) 359-6171 greenheck.com 00.LAB.1015 R1 8-2013 IW Copyright 2013 Greenheck Fan Corp.