READ AND SAVE THESE INSTRUCTIONS

Similar documents
Installation, Operation and Maintenance Manual

Emergency Smoke Control Centrifugal Roof Exhaust Fans

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

INSTALLATION, OPERATION & MAINTENANCE MANUAL AXIAL UPBLAST FANS RTA, RWTA, RHTA, RB, RD, RTA SH

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP

for Untempered - Make-Up Air Units

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

General Safety Information. Table of Contents. Document Model Vektor -MH, Vektor -MD and Vektor -MS Laboratory Exhaust System

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting

MODEL VBO-HV & VBO UPBLAST PROPELLER ROOF FANS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL RBK FRP FAN

Direct Gas-Fired Heating

Tubular Centrifugal Inline Fans TCN

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL CNW DHK PVK

SQI Centrifugal Square Inline Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Tubular Centrifugal Fans

MODEL CLS Centrifugal Filtered Supply Fans

Operation and Maintenance Manual. Series BI Centrifugal Blowers

CFS Centrifugal Filtered Supply Fans

DUCT BLOWER Cabinet Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL

General Safety Information. Document KSFB and KSFD DANGER CAUTION WARNING! DBC DB3. Horizontal

Installation, Operation and Maintenance Manual

DPL/DPL-AF SERIES PLENUM FANS OPERATION INSTRUCTIONS AND PARTS MANUAL MODELS: DPL/DPL-AF-12, 13, 15, 16, 18, 20, 22, 24, 27, 30, 33, 36 GENERAL SAFETY

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

ASP/KSP Centrifugal Filtered Supply Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL

SRSH Tamper Proof Centrifugal Exhauster INSTALLATION, OPERATION AND MAINTENANCE MANUAL

TMX Mixed Flow Inline INSTALLATION, OPERATION AND MAINTENANCE MANUAL

SQN Centrifugal Square Inline Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

Propeller Hooded Roof Fans

Installation, Operation and Maintenance Manual

Utility Distribution System

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

READ AND SAVE THESE INSTRUCTIONS. Installation Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Table of Contents. Document Centrifugal Utility Fans. Model SWB - Series 100, 200 and 300 Models SFB, SFD, SWB and SWD. Model SWB Series 200

ECONOMIZER FAN. Receiving and Inspection

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

FCP Fiberglass Blower INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

QMX Mixed Flow Inline INSTALLATION, OPERATION AND MAINTENANCE MANUAL

HA/HAB Fiberglass Wall Mount Ventilators

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust

LO-PRO. Receiving and Inspection. Handling Lift the fan by the base. NOTICE! Never lift by the shaft, motor or housing.

CPL Centrifugal Plenum Fans

INSTALLATION MANUAL TBH/TBV BELT DRIVE BLOWER-COIL UNITS HORIZONTAL. Redefine your comfort zone.

Installation, Operation and Maintenance Manual

IMPORTANT! READ BEFORE PROCEEDING! US General Purpose Centrifugal Fan

CCP Centrifugal Plug Fans

Installation, Operation and Maintenance Manual

IMPORTANT! READ BEFORE PROCEEDING! PHR Axial Flow Hooded Roof Ventilators

BCFS Belt Driven Centrifugal Filtered Supply Fans

forward curved inline duct blowers

FCE/FCRU Fiberglass Roof Exhausters INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Installation. Centrifugal Roof and Wall Exhausters

Energy Recovery Laboratory Exhaust

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

Duct Blower Cabinet Fans

Installation, Operation, and Maintenance Instructions

REBEL/AQ/SEP/ETE/ETS IO&M

Power Roof Ventilator Installation, Operation, and Maintenance Manual. Down-blast Centrifugal Fan Utility Set Axial Fan

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Instructions

Energy Recovery Laboratory Exhaust

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Installation, Operation and Maintenance Manual

Gravity Ventilators. Models FGI and FGR. Fabra Hood Intake and Relief

Installation, Operation and Maintenance Manual

2. Backward inclined / backward curved centrifugal wheel fans. 3. Axial / backward curved mixed flow impeller bifurcated fans.

AC/VCR Centrifugal Roof and Wall Exhausters INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Installation, Operation and Maintenance Manual

MAINTENANCE - LPX PORTABLE TREATER

Backward Inclined Hinged Restaurant Exhaust Fan

Model CUBE Belt Drive. Model CUE Direct Drive

Air Boss Model M3000. Industrial Air Cleaner READ AND SAVE THESE INSTRUCTIONS. TRION

Centrex Inliner Direct & Belt Drive

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

SECTION AXIAL HVAC FANS

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

AXIAD II Fans. General Installation, Operation and Maintenance Instructions For Aerovent Products

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

Installation, Operation and Maintenance Manual

SECTION CENTRIFUGAL HVAC FANS

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

TUBULAR CENTRIFUGAL INLINE FANS

Transcription:

READ AND SAVE THESE INSTRUCTIONS Part #469003 Model Vektor -H Installation Operation and Maintenance Manual for Vektor-H Laboratory Exhaust System Receiving Greenheck model Vektor-H fans are thoroughly inspected, test run at the factory, and shipped on a skid or packaged to minimize damage during shipment. The transportation carrier has the responsibility of delivering all items in their original condition as received from Greenheck. The individual receiving the equipment is responsible for inspecting the unit for obvious or hidden damage and recording any damage on the bill of lading before acceptance of the equipment. All claims (if necessary) shall be filed with the final carrier. Lifting Lugs Lifting Lugs Single Blower System Single Blower System with Plenum Multiple Fan System with Plenums Handling & Installation The Greenheck Vektor-H laboratory exhaust system is shipped in subassembly sections for easy rigging and installation. Depending on the options ordered, the sections can include:, Plenum Assembly, Blower Assembly, Stack Extension, and Discharge Nozzle. The Vektor-H is designed to be self-supporting and standing (without the use of guy wires) when assembled per the instructions provided within this manual. The roof curb must be securely fastened to the roof structure in accordance with the contract documents. All subassembly sections have lifting lugs as shown. NOTE! Lifting lugs on each subassembly are designed to handle the weight of the subassembly section only. Do not attempt to lift the entire system as a complete assembly.

NOTE! Be sure to rig each section separately using the lifting lugs provided. Installation Instructions Note: When installing each section, be sure to rig each piece separately using the lifting lugs provided. 1. Mount roof curb to roof deck in accordance with local codes. 2. Install 3/16-inch thick x 1/2-inch wide, closed-cell neoprene gasket on the top edge of the curb, adhesive side down (gasket provided). Leave no gaps between gasket sections to ensure tight seal. 3. Place the bypass air plenum (BAP) onto the previously installed gasket and secured roof curb. If a BAP is not provided for the unit, skip to Step 5. Pre-drill pilot holes into the roof curb and attach the BAP to the roof curb using the provided 5/16-inch self-tapping screws. Screw fasteners are to be installed in all pre-punched curb holes. 4. Install 3/16-inch thick x 1/2-inch wide, closed-cell neoprene gasket on the top edge of BAP, adhesive side down (gasket provided). Leave no gaps between gasket sections to ensure a tight seal. 5. Place the curb cap of the fan housing onto the gasket and BAP (onto roof curb if BAP is not provided). Attach the curb cap using the provided 5/16-inch self-tapping screws. If a BAP is not provided, pilot holes must be drilled into the roof curb. 6. Install the final nozzle subassemblies as shown in the submittal drawing. Align flange bolt holes and fasten sections using the 316 stainless steel bolts, washers, and lock washers provided. 7. Follow electrical connection and pre-start-up checks as listed on page 3. Bolt / Washer Detail 5/16 in. Self-tapping Screws Neoprene Gasket Duct Connection to Curb The end of the customer supplied duct is secured between the roof curb s top edge and the curb cap of either the Vektor-H or bypass air plenum. If an isolation damper is present in the roof curb, the duct is located between the roof curb and the damper adapter tray. Vektor-H Vektor-H or bypass air plenum Adapter Tray Isolation Damper Vektor-H with or without bypass air plenum & no isolation damper in roof curb Vektor-H without bypass air plenum & with isolation damper in roof curb Duct to Plenum Vektor-H with Option B - Side Air Intake Plenum Laboratory Exhaust Duct Duct flange and gasketing by others 2

Vektor Installation The figures below illustrates four common methods used to install Vektor systems. Methods used to attach a Vektor unit are dependent on local codes, roof construction design and roof construction materials. Consult an architect or structural engineer for proper means of attachment. Weatherhood w/ birdscreen (optional) 5/16 in. bolt 5/16 in. bolt Plenum Weatherhood w/ birdscreen (optional) Plenum 3/8 in. bolt Fiberglass Insulation Bolt or weld in field Structural Support Field drilled and bolted Structural Support Fan, Plenum, and Curb to Structural Steel Fan and Plenum (no Curb) to Channel Base 5/16 in. self-tapping screws Weatherhood w/ birdscreen (optional) Plenum Fan 3/8 in. bolt Bolt or weld in field Exhaust Duct Fiberglass Insulation Roof Line (Roofing felt & material by others) 3/8 in. bolt Bolt or weld in field Fiberglass Insulation Exhaust Duct Roof Line (Roofing felt & material by others) Fan, Plenum, and Curb to Roof Deck Fan and Curb (no Plenum) to Roof Deck Plenum Drainage Piping / Trap Detail (By Others) There are multiple locations for pipe connections, one on each plenum section and another on each tubular fan housing. Each drain should be properly connected to a drainage system to ensure proper disposal of any water or condensate that may occur. Installed piping to have a downward angle to allow for drainage Fill trap to recommended level before start-up Detail of Plenum and Blower Housing 1 in. drain coupling in Blower Housing and Plenum Y X 1 inch of water Y Dim > System Pressure X Dim > 1/2 System Pressure *Dimension of X and Y are inches 3 Clean out location

Electrical Connections Before electrical connections are made, the supply voltage, phase and ampere capacity must be checked for compatibility with the fan motor. In addition, the supply wiring must be properly fused and conform to local and national electrical codes. If the unit is supplied with a safety disconnect switch, ensure proper wiring to the fan motor. Be sure the disconnect is switched to the OFF position before connecting supply wires. If no disconnect is supplied, ensure the supply wire is not live before connection. Supply wires are then connected to the optional safety disconnect switch (if supplied) or motor. Motor - Disconnect Wiring / Isolation Damper Wiring Diagram LINE IN 208 / 230 / 460 / 575 V 3 PHASE DISCONNECT IS MOUNTED TO FAN HOUSING. TRANSFORMER IS MOUNTED TO MIXING BOX (BYPASS AIR PLENUM) WITH DAMPER ACTUATOR. FOR SYSTEMS THAT SHIP UNASSEMBLED BECAUSE OF PHYSICAL SIZE, THIS CONNECTION AT DISCONNECT FROM TRANSFORMER MUST BE FIELD INSTALLED. WIRE WITH CONDUIT AND FITTING IS PROVIDED PRE-CONNECTED TO TRANSFORMER. DISCONNECT 208 / 230 / 460 / 575 V 3 PHASE TRANSFORMER 208 / 230 / 460 / 575 V 1 PHASE OPTIONAL FACTORY MOUNTED AND WIRED ISOLATION DAMPER ACTUATOR FIELD WIRING FACTORY WIRING 208/230/460/575/60/3 115V 1 PHASE ISOLATION DAMPER ACTUATOR POWER OPEN/SPRING CLOSE Applications with Variable Frequency Drive (VFD) For Vektor systems with single-point, three-phase wiring per blower, the isolation damper actuator will be powered via a step-down transformer, which is wired to the fan disconnect, as shown in the diagram above. If fan flow (motor speed) is to be controlled using a variable frequency drive with this wiring, the reduced voltage and frequency supplied to the fan will cause control problems with the isolation damper actuator. When a project s Vektor control sequence requires the use of a VFD, it is suggested that the control contractor supply the isolation damper actuator voltage independent of the power supplied to the Vektor fan motor. 4

Pre-Start-Up Checks 1. Check all fasteners for tightness. 2. The wheel should be aligned as shown. Although the wheel position is preset and the unit is test run at the factory, movement may occur during shipment. The radial gap should be consistent at all locations between the centrifugal wheel and the inlet cone. Centering may be accomplished by loosening the inlet cone bolts and repositioning the inlet cone. Wheel Overlap To obtain the optimum performance, the centrifugal wheel must overlap the inlet cone. Adjustments can be made by loosening the set screws in the wheel and moving the wheel to the desired position. Radial Gap Direction of Airflow Inlet Cone 3. Wheel rotation should be in the same direction as the rotation decal affixed to the unit. For 3-phase installations, fan rotation can be reversed by simply interchanging any two of the three electrical leads. For single phase installations, follow the wiring diagram located on the motor. 4. Adjustable motor pulleys are preset at the factory for the specified fan RPM. Fan speed can be increased by closing or decreased by opening the adjustable pulley. Two or three groove variable pitch pulleys must be adjusted an equal number of turns open or closed. Note: Any increase in fan speed represents a substantial increase in horsepower required from the motor. Always check motor load amperage and compare to nameplate rating when changing fan speed. Maintenance WARNING DISCONNECT ALL ELECTRICAL POWER TO THE FAN AND SECURE TO THE OFF POSITION PRIOR TO INSPECTION OR SERVICING. FAILURE TO COMPLY WITH THIS SAFETY PRECAUTION COULD RESULT IN SERIOUS INJURY OR DEATH. Once the fan has been put into operation, a periodic maintenance program should be set up to preserve the reliability and performance of the fan. Items to be included in this program are: BEARINGS SET SCREWS BELTS S FASTENERS REMOVAL OF DUST/DIRT Bearings Bearings are the most critical moving part of the fan and should be inspected at periodic intervals. Locking collars and set screws, in addition to fasteners attaching the bearing to the bearing plate, must be checked for tightness. In a clean environment with temperatures above 32º F and below 200º F, fan shaft bearings with grease fittings should be lubricated semi-annually using a high quality lithium based grease. If unusual environmental conditions exist such as temperatures below 32º F or above 200º F, moisture or contaminants, more frequent lubrication is required. With the unit running, add grease very slowly with a manual grease gun until a slight bead of grease forms at the seal. Be careful not to unseat the seal by over lubricating or using excessive pressure. Bearings without grease fittings are lubricated for life. 5

Belts Premature belt failures are frequently caused by improper belt tension (either too tight or too loose) or misaligned pulleys. The proper tension for operating a V-belt is the lowest tension at which the belts will not slip at peak load conditions. For initial tensioning, the proper belt deflection half-way between pulley centers is 1/64 inch for each inch of belt span. For example, if the belt span is 64 inches, the belt deflection should be one inch using moderate thumb pressure at midpoint of the drive. Check belt tension two times during the first 24 hours of operation and periodically thereafter. To adjust belt tension, simply loosen four fasteners (two on each side of the motor plate) and slide the motor plate away from the fan shaft until proper belt tension is attained. On some fans, fasteners attaching the motor to the motor plate must be loosened in order to adjust the belt. It is very important that the drive pulleys remain in proper alignment after adjustments are made. Misalignment of pulleys will result in premature belt wear, noise, vibration and power loss. Fasteners and Set Screws A periodic inspection should include checking all fasteners and set screws for tightness. Particular attention should be paid to set screws attaching the propeller to the shaft and the shaft to the bearings. Loose bearing set screws will lead to premature failure of the fan shaft. Motors Many fractional horsepower motors installed on the smaller fans are lubricated for life and require no further attention. Motors supplied with grease fittings should be greased according to directions printed on the motor. Removal of Dust and Dirt Dirt clogs cooling openings on the motor housing, contaminates bearing lubricant, and collects on the impeller causing severe imbalance if left unchecked. The exterior surface of the motor and impeller should be thoroughly cleaned periodically. Use caution and do not allow water or solvents to enter the motor or bearings. Under no circumstances should motors or bearings be sprayed with steam or water. Exhaust Fans Part List Each fan bears a manufacturer s nameplate with model number and serial number embossed. This information in addition to the parts list shown, will assist the local Greenheck representative and the factory in providing service and replacement parts. Belt Span Deflection = Belt Span 64 Side View Top View BELT BELT TUBE SHAFT PULLEY BEARING COVER PLATE COVER (OPTIONAL) PULLEY BEARINGS BEARING SUPPORT SHAFT WHEEL INLET CONE (VENTURI) Our Warranty Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the purchase date. Any units or parts which prove defective during the warranty period will be replaced at our option when returned to our factory, transportation prepaid. Motors are warranted by the motor manufacturer for a period one year. Should motors furnished by Greenheck prove defective during this period, they should be returned to the nearest authorized motor service station. Greenheck will not be responsible for any removal or installation costs. As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. #469003 Vektor-H IOM Rev. 2, August 2006 Copyright 2006 Greenheck Fan Corp.