IVET-D 16A / 3,5 kva IVET-D 30A / 7,5 kva IVET-D 16A / 3,5 kva - MT

Similar documents
Mass Sine 24/10000 Mass Sine 24/15000

DC Master 24/ A

GEBRUIKERSHANDLEIDING / USERS MANUAL BETRIEBSANLEITUNG / MODE D EMPLOI ALPHA PRO

MASS COMBI 12/ & 24/

MASS COMBI 12/ (120V & 230V), 12/ (120V & 230V), 24/ (120V & 230V), 24/ (120V), 24/ (230V)

MASS COMBI 12/ (120V), 12/ (120V), 24/ (120V), 24/ (120V)

Li-ion Battery. MLi Ultra 12/2500 MLi Ultra 12/5000 MLi Ultra 24/5000 INSTALLATION AND COMMISSIONING OF MULTIPLE BATTERIES

ALPHA ALTERNATOR 12/90, 12/130, 24/75, 24/110 & 24/150

Mass Combi Ultra 12/ , 24/ , 48/

MASTERVOLT PRICE LIST

AERL RACEMAX MAXIMIZER User's Manual

MASTERVOLT PRICE LIST

Mass Charger MASS 12/60-2 MB; 12/80-2 MB; 24/50-2 MB; 24/75 MB; 24/100 MB; 3-24/100 MB; 48/25 MB; 48/50 MB

IQL Helios Area-/Streetlight. User Manual

TFP200 FLOOR PLANER OPERATION & MAINTENANCE

Mass Charger MASS 24/15-2 MB; 24/25-2 MB; 24/25-2 DNV MB

Mod: KLD6-12/35XLAS-N

EASY CHARGE Waterproof portable Battery Charger

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Power you can rely on

USERS MANUAL / GEBRUIKERSHANDLEIDING BETRIEBSANLEITUNG / MANUEL D UTILISATION MANUAL DE UTILIZACION / INSTRUZIONI PER L USO.

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

Table 3. Pumping Range. 6 in cm. 8 in cm. 16 in cm. 6 in cm. 14 in cm. 18 in cm.

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

ChargeMaster 12/25-3, 24/12-3

Appendix: Safety and application notes for... 15

Phoenix Inverter

USE AND INSTALLATION HANDBOOK

Oil-free piston compressors KK and piston vacuum pumps KV

USER MANUAL OUTBOARD MOTOR AC

Operating Instructions

CHARGEMASTER 1 12/35-3, 12/50-3, 24/20-3, 24/30-3

c-go 24V/6A 24V/8A 24V/12A

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Declaration of Conformity

EASY CHARGE Weather-resistant fixed mount Battery Charger

USER S MANUAL / GEBRUIKERSHANDLEIDING BETRIEBSANLEITUNG / MANUEL D UTILISATION MANUAL DE UTILIZACION / INSTRUZIONI PER L USO.

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

CHARGEMASTER 12/25-3, 24/12-3

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Multi-Mover Charger for model L25

DriveMaster 2.5 & 3.6

CHARGEMASTER 12/35-3, 12/50-3, 24/20-3, 24/30-3

Power you can rely on

EF SERIES MOTORS OPERATION & PARTS MANUAL

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

SUBMERSIBLE WATER PUMP

Submersible waste water pumps. Installation and operating instructions Series: DVV

Sinewave Inverters. SWING 150VA and 300VA. User s manual

Operating instructions Flow monitors SI / / 2010

Technical Documentation

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

ILED Dorado. User Manual

OPERATION INSTRUCTIONS

HEINE NT4 MED V

TPAK Series COOLANT PUMP

Lithium-ion Battery MLI-E 12/1200 USERS MANUAL

Armon Edero. User manual

User manual for. Exalto windshield wiper Type 223 BD 12/24 Volt

6 x 10 Belt Disc Sander

RU BMS Power Supply and Battery Management System Owners Guide

Pure Sine Wave Inverter 600W-24V User Manual

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03

INDUSTRIAL POWER SUPPLIES SFL-SERIES

OPERATING AND USERS MANUAL

USERS MANUAL / GEBRUIKERSHANDLEIDING BETRIEBSANLEITUNG / MANUEL D UTILISATION MANUAL DE UTILIZACION / INSTRUZIONI PER L USO.

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

High Frequency SineWave Guardian TM

HOME BOX EV CHARGING STATION WITH FIXED CABLE

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

PRODUCTS: POWER SUPPLY

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

OPERATING SERVICE MAINTENANCE MANUAL

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

English. Instruction and operation manual S 110. Power Meter

Environmental Series Air Curtains

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Direct Coupled Damper Actuator Model MY6050A1001

Master Plus kva

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

ZB0050 / ZB0051 ZB0070 / ZB0071

Automatic concealed bollards 275 H600 and 275 H800 with pit

ROM Series. Keeping the World Flowing. Installation Manual. Valve Actuators

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. MODEL PF1 Rated 15,25,40 & 70 Amps, Single Phase SCR Power Controls. ISE, Inc

Compact System NRGS 11-2 NRGS Original Installation Instructions English

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

HarmonicGuard Series Drive-Applied Harmonic Filter Installation, Operation, and Maintenance Manual

Transcription:

OPERATING EN INSTALLATION MANUAL IVET-D 16A / 3,5 kva IVET-D 30A / 7,5 kva IVET-D 16A / 3,5 kva - MT Isolation transformer with soft start MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com

CONTENTS: V2 march 03 1 GENERAL INFORMATION...3 1.1 Use of this manual...3 1.2 Guarantee Specifications...3 1.3 Quality...3 1.4 Validity of this manual...3 1.5 Liability...3 2 SAFETY GUIDELINES & MEASURES...4 2.1 Warnings and symbols...4 2.2 Use for intended purpose...4 2.3 Organizational measures...4 2.4 Warning for special dangers...4 3 INSTALLATION...5 3.1 Environment...5 3.2 Mounting...5 3.3 Connection...5 3.4 Adjustment of the output voltage (multi tap / model 86060351 only)...6 3.5 Adjustment of the input voltage (multi tap / model 86060351 only)...6 3.6 Commissioning the IVET-D...7 4 OPERATION...8 4.1 Introduction...8 4.2 Automatic circuit breaker...8 4.3 Temperature protection...8 5 DIMENSIONS...9 6 PRINCIPLE SCHEMATIC...10 7 TECHNICAL DATA...10 8 CE DECLARATION OF CONFORMITY...11 2 March 2003 / IVET-D 16A/30A / EN

1 GENERAL INFORMATION With the installation of electrical systems on board of a ship, extra attention must be paid to not only the safety of these systems, but to the prevention of galvanic corrosion or electrolysis of the ship hull as well. The Mastervolt IVET-D isolation transformer provides you a galvanic separation between shore-power and the onboard electrical system, eliminating these risks. The input circuit of the IVET-D is equipped with a soft-start unit to eliminate high inrush currents, and an automatic circuit breaker to protect your electrical system against overload. 1.1 Use of this manual This manual serves as a guideline for safe and effective operation, installation, maintenance and possible correction of minor malfunctions of the IVET-D. It is therefore obligatory that every person who works with the IVET-D must be completely familiar with the contents of this manual, and that you carefully follow the instructions contained herein. The manual must be immediately accessible to the user. This manual has 8 chapters. 1.2 Guarantee Specifications 1.3 Quality During the production and prior to their delivery, all our units are exhaustively tested and inspected. The guarantee period is two years. 1.4 Validity of this manual All of the specifications, provisions and instructions contained in this manual apply solely to the MASTERVOLT-delivered standard versions of the IVET-D. 1.5 Liability MASTERVOLT can accept no liability for: Consequential damage due to use of the IVET-D. Possible errors in the manuals and the results thereof. CAREFUL! Never remove the type and number plate. Important technical information required for service, maintenance & secondary delivery of parts could be found from the type number-plate. Mastervolt guarantees that this unit has been built in accordance with the legally applicable standards and specifications. Should work take place, which is not in accordance with the guidelines, instructions and specifications contained in the user manual, damage may occur and / or the unit may not fulfil its specifications. All of these matters may mean that the guarantee may become invalid. March 2003 / IVET-D 16A/30A / EN 3

2 SAFETY GUIDELINES & MEASURES 2.1 Warnings and symbols Safety instructions and warnings are marked in this manual by the following symbols and pictograms: 3 Use other than as mentioned under 2 is not considered to be consistent with the intended purpose. MASTERVOLT is not liable for any damage resulting from the above. 2.3 Organizational measures Procedures which deserve extra attention. CAREFUL! Special data: restrictions and rules with regard to the prevention of damage. WARNING! A WARNING refers to possible injury to the user or significant material damage to the IVET-D if the user does not (carefully) follow the procedures. 2.2 Use for intended purpose 1 The IVET-D is constructed as per the applicable low voltage directive and safety regulation EN 60950 The user must always: Have access to the user manual Be familiar with the contents of this manual. This applies particularly to Chapter 2, Safety Guidelines & Measures. 2.4 Warning for special dangers 1 Check the wiring at least once a year. Defects such as loose connections, burnt wiring etc. must be corrected immediately. 2 Do not work on the IVET-D or the system if it is still connected to a power source. Only allow changes in your electrical system to be carried out by qualified electricians. 2 Use the IVET-D only: In a technically correct condition. In a closed room, protected against rain, moisture, dust and non-condensing circumstances. Observing the instructions in the manual. WARNING! Never use the IVET-D at locations where there is danger of gas or dust explosion! 3 Installation must be done in accordance with the local regulation for electrical installations. 4 For a safe installation the right cable diameter must be applied. 5 Isolation transformers are heavy! Ensure adequate mounting security and always use suitable handling equipment for transportation. 4 March 2003 / IVET-D 16A/30A / EN

3 INSTALLATION 3.1 Environment WARNING The electrical system must be disconnected from any power source during installation! Ensure that the IVET-D in placed in a dry, well ventilated environment, protected against water and/or dust. The airflow may not be blocked. For optimum airflow, the IVET-D should always be mounted vertically. The EMC-characteristics to which the IVET-C is part of, is affected by the way the wiring is installed. 3.2 Mounting Be sure that the panel to which the IVET-D is mounted is strong enough to last the weight of the IVET-D. Use M6 of M8 bolts to fix the IVET- D to the mounting panel. 3.3 Connection WARNING Check the adjustments for input voltage and output voltage before operating the IVET-D. Check from the type number plate whether: - the AC voltage of the power source is the same as the input voltage of the IVET-D. - the output voltage of the IVET-D is appropriate to supply the connected load. Refer to chapter 3.4 and 3.5 to adjust the input voltage, respectively the output voltage of the multi tap version. To connect the wiring, proceed as follows: 1. Unscrew the four screws of the cabinet s front panel and remove the front panel. 2. Pass the shore cable through the left hand sided cable gland, at the bottom of the cabinet. Pass the AC-output cable through the right hand sided cable gland. 3. Cut the cable at length in accordance with figure 1. Strip the three conductors for 8mm. 5 cm at least Take the following steps to mount the cabinet: 1. Determine the spots to fix the bolts into the mounting panel, using the outline drawings of chapter 5 (page 9) 2. Screw the topmost bolts somewhat into the mounting panel. 3. Place the IVET-D wit hits key holes over the two bolts. Tighten the bolts finger tight, so that shifting the cabinet is still possible. 4. Place the two lowermost bolts into the mounting panel. 5. Fasten all bolts securely. green/yellow brown blue Figure 1 4. Connect the shore cable to the terminals that are indicated with INPUT. Connect the load to the terminals that are indicated with OUTPUT. Refer to figure 2. Connect the March 2003 / IVET-D 16A/30A / EN 5

green/yellow wire to PE, connect the brown wire to L1 and connect the blue wire to N. 5. Tighten the cable-glands securely. 6 Figure 3: 230V output voltage 7 PE L1 N PE Figure 2 N L INPUT OUTPUT 3.4 Adjustment of the output voltage (multi tap / model 86060351 only) The output voltage of the IVET-D must be the same as the input voltage of the connected load. Adjust the output voltage by changing the wiring of the IVET-D according to the following instructions: - 230 Volt: refer to figure 3. Connect transformer wire 6 to terminal 6 at the 230Vside and connect the transformer wire 7 to terminal 7 at the 230V-side. - 115 Volt: refer to figure 4. Connect transformer wire 6 to terminal 6 at the 115Vside and connect the transformer wire 7 to terminal 7 at the 115V-side. 6 7 Figure 4: 115V output voltage 3.5 Adjustment of the input voltage (multi tap / model 86060351 only) The AC voltage of the power source must be the same as the input voltage of the IVET-D. Select the input voltage by shifting the input voltage selector to the required voltage. The input voltage is indicated by the selector. Replace the 16 Amps circuit breaker by the loose supplied 32 Amps circuit breaker if the IVET-D is connected to a 115V power source. 6 March 2003 / IVET-D 16A/30A / EN

Input voltage selector Figure 5: input voltage selection The input of the isolation transformer is standard provided with a 16 Amps automatic circuit breaker. This circuit breaker protects the transformer against overload if the transformer is connected to a 230V power source. Replace the 16 Amps circuit breaker by the loose supplied 32 Amps circuit breaker if the IVET-D is connected to a 115V power source. Compared to 230V, the current will be twice as high at 115V if the connected load is the same. 3.6 Commissioning the IVET-D Double check all wiring and connections before operation. 1. Switch on the automatic circuit breaker of the IVET-D. 2. Close the cabinet by fixing the front cover with the four screws. WARNING The IVET-D should only be taken into operation while the front cover is closed. 3. Connect the shore cable to the power source. March 2003 / IVET-D 16A/30A / EN 7

4 OPERATION 4.1 Introduction The Mastervolt IVET-D isolation transformer provides you a galvanic separation between shore-power and the onboard electrical system. The input circuit of the IVET-D is equipped with a soft-start unit to eliminate high inrush currents, and an automatic circuit breaker to protect your electrical system against overload. The IVET-D operates automatically. Under normal circumstances, there is no need for operation. 4.2 Automatic circuit breaker The IVET-D is provided with an internal automatic circuit breaker. This circuit breaker switches off the IVET-D in case of overload or short-circuits. To reset the internal circuit breaker, proceed as follows: 1. Disconnect the shore cable from the power supply. Be sure the IVET-D is disconnected from any power source. 2. Investigate the cause of failure of the automatic circuit breaker, like overload or short-circuits. Disconnect all loads from the IVET-D. 3. Unscrew the four screws of the cabinet s front panel and remove the front panel. 4. Switch on the circuit breaker (see figure 5) 5. Close the cabinet by fixing the front cover with the four screws WARNING The IVET-D should only be taken into operation while the front cover is closed. 6. Connect the shore cable to the power source. 4.3 Temperature protection Despite its high efficiency, the IVET-D will still produce some heat, especially with high loads connected. The heat that is produced by the transformer of the IVET-D is discharged by means of a cooling fan. This cooling fan starts automatically when the transformer s temperature exceeds 80 C. If a temperature of 120 C is reached, the IVET-D is switched off until the temperature has dropped again below 80 C approximately. Figure 6: Power up automatic circuit breaker 8 March 2003 / IVET-D 16A/30A / EN

5 DIMENSIONS IVET-D 16A 3,5kVA IVET-D 16A 3,5kVA-MT Scheidingstransformator Isolation transformer Transformateur d'isolation Power rating 3.5kVA / 16A With automatic softstart and breaker Warning Keep front closed during operation because of danger of electric shock IVET-D 30A 7,5kVA Scheidingstransformator Isolation transformer Isolations Transformator Transformateur d'isolation Power rating 7.5kVA / 30A With automatic softstart and breaker Warning Keep front closed during operation because of danger of electric shock March 2003 / IVET-D 16A/30A / EN 9

6 PRINCIPLE SCHEMATIC SOFTSTART INPUT L N L N OUTPUT PE PE 7 TECHNICAL DATA Type IVET-D 16A 3,5kVA IVET-D 30A 7,5kVA IVET-D 16A 3,5kVA - MT Part number 86050351 86050751 86060351 ALGEMEEN Input voltage 220-240V 220-240V 220-240V / 110-120V U-in adjustable No No Yes Output voltage 220-240V 220-240V 220-240V / 110-120V U-out adjustable No No Yes Frequency in/out 50-60 Hz 50-60 Hz 50-60 Hz Load 16 Amp. / 3680 W 30 Amp. / 6900 W 16 Amp./ 3680W @ 230V 32 Amp / 3680W @ 115V Soft start Yes Yes Yes Transformer Torodial Cooling Natural convection, above 80 C forced cooling Temp. Protection Load is disconnected at temperatures above 120 C CABINET Model D1 D2 D1 Dimensions (hxwxd) 407 x 295 x 220 mm 505 x 305 x 250 mm 407 x 295 x 220 mm Protection degree IP 23 IP 23 IP 23 Colour RAL 7035 (grey/white) RAL 7035 (grey/white) RAL 7035 (grey/white) Weight 23 kg 48 kg 23 kg 10 March 2003 / IVET-D 16A/30A / EN

8 CE DECLARATION OF CONFORMITY Manufacturer: Mastervolt Address: Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Herewith declares that: Product: IVET-D 16A / 3,5 kva IVET-D 30A / 7,5 kva IVET-D 16A/ 3,5 kva - MT Is in conformity with the provision of the EEC directive EMC 89/336/EEG and amendments 92/31/EEG and 93/68/EEG. The following harmonized standards have been applied: Emission: EN 50081-1:1992 Immunity: EN 50082-1:1992 Safety: EN 60950-1:1992 Amsterdam, Dr. F.J. ter Heide, Director MASTERVOLT March 2003 / IVET-D 16A/30A / EN 11

Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands Tel: + 31-20-3422100 Fax: + 31-20-6971006 Email: info@mastervolt.com