DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

Similar documents
TECHNICAL SPECIFICATIONS OF PCC PANEL


Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

DPX 1600 Electronic release

DRX 250 B/N/H Circuit breaker (not adjustable)

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

DRX 100 B/N/H Circuit breaker (not adjustable)

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

(Under Two Part Bid System) Tender No: NFV/ PUR/ BEC K for VCB

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DMX 3 -I 2500 switch disconnectors

DPX 630 Electronic release

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

Wall mounted switchgear

cor Long Run Experience

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DRX 125 Circuit breaker (not adjustable)

33KV INDOOR SWITCHGEAR

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Thermal magnetic and trip-free switches

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

(High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT. Enquiry Date:

Technical Specifications

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

DPX earth leakage DPX 3 -I earth leakage

West Bengal State Electricity Distribution Co. Ltd.

Moulded Case Circuit Breakers

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

DPX moulded case circuit breakers

3 - Protection components Motor circuit-breakers

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

DPX Magnetic only

AF40... AF96 3-pole contactors Technical data

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

Motor Protection Circuit Breakers 3VU13 and 3VU16

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

WEST BENGAL STATE ELECTRICITY DIST. COM. LTD. ( A

Memshield - ACB Ratings & Specifications

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

AN ISO 9001 & COMPANY TENDER DOCUMENT. TENDER No: DLI/CON/696/411 FOR

PIX-H Metal-clad switchgear up to 17.5kV

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

045 : 2000 CEB STANDARD

Key features. DESIGNS: - Conservator type - Hermetically sealed

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Euroload Changeover Switch

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Motor Protection Circuit Breakers

Phase + Neutral, neutral on right side

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

UniGear. Technical Guide

ATX DPD Series Distribution Panelboards Flameproof

Cascading & Discrimination

Phase + Neutral, neutral on left side

37-SDMS-04 SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS


SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

Change-over Disconnectors HUVS Range 36kV (630 to 6300Amp)

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

DX³ 4-pole RCBO 6000 A/10 ka

SPECIFICATION FOR BATTERY & BATTERY CHARGER (D.C. SYSTEM)

NS Feeder pillar up to 3200A

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Bridging The Gap Effectively... SWITCHGEAR Panels Components Accessories Relay & Meters

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

Changeover & Bypass Sw it ches

Vistop TM isolating switches 63 to 160A

BETA Switching Switches and Light Indicators

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

E-12 Low-voltage Switchboard

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Circuit Breaker Prepared By :

Motor Circuit Breakers C4

LOW VOLTAGE DISTRIBUTION POWER & CONTROL

COMPACT SUBSTATION GUIDE

Power protection solutions

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue

D509E. Manual Motor - Starters

Moulded case circuit breakers

TENDER DOCUMENT. (TENDER No: NRO/CON/696/660) FOR

Perfection that Matters

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

NB1 Miniature Circuit Breaker

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Transcription:

44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7 MTRS. 3 RELATIVE HUMIDITY 74 % 4 MAX. RAINFALL PER DAY 348.6 MM PER ANNUM 5 LOCATION - 6 SITE ENVIONMENT TROPICALIZED, MARINE, WITH PRESENCE OF CORROSIVE FUMES B SYSTEM PARTICULARS VOLTAGE 45 V ± 0 % 2 FREQUENCY 50 Hz ± 5 % 3 NO. OF PHASES / WIRE 3 PHASE / 4 WIRE 4 SYSTEM GROUNDING EFFECTIVE / NON EFFECTIVE 5 FAULT LEVEL 50 ka, 3 Ph, SYMM. C CONTROL / AUXILIARY SUPPLY BREAKER. SPRING CHARGING MOTOR 0 V AC / DC.2 CLOSING COIL 0 V AC / DC.3 TRIPPING COIL 0 V AC / DC.4 CONTROL CIRCUITS 0 V AC / DC 2 MOTOR FEEDERS (FSU WITH CONTACTOR TYPE FEEDERS) 2. CONTACTOR COIL 240 V AC 3 POTENTIAL INDICATING LIGHTS 240 V AC 4 OTHER INDICATING LIGHTS 240 V AC 5 SPACE HEATERS 240 V AC D CONSTRUCTION TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED 2 TYPES OF FEEDERS : ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT ( b ) ALL OTHER FEEDERS FULLY DRAWOUT / SEMI DRAWOUT/ NON DRAWOUT 3 NO. OF FRONTS SINGLE FRONT / DOUBLE FRONT 4 BASE FRAME ISMC 75 5 DEGREE OF PROTECTION IP 52 (MINIMUM) E RATING OF CIRCUIT BREAKERS TYPE OF C.B. ACB 2 POLES 3 POLE / 3 POLE WITH NEUTRAL LINKS / 4 POLE 3 VOLTAGE 45 V X:\STD\FORMS\E04-002A_Rev REV. 0 PAGE : OF 5 APPLICABLE STANDARD SPECIFICATION :44LK-500/E.02/002 003

44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV 4 NOMINAL CURRENT * AMPS. 5 RATED SHORT CIRCUIT MAKING CAPACITY (Icm) 0 ka (PEAK) 6 RATED ULTIMATE SHORT-CIRCUIT BREAKING 50 ka (RMS) CAPACITY (Icu) 7 RATED SERVICE SHORT-CIRCUIT BREAKING 50 ka (RMS) CAPACITY (Ics) 8 RATED SHORT TIME CURRENT WITHSTAND 50 ka FOR SEC CURRENT (Icw) 9 UTILISATION CATEGORY * A / B (AS PER IS 3947 (PART-2) : 993) 0 TEMPERATURE RISE 40 C OVER AMBIENT TEMP. OF 45 C DIELECTRIC WITHSTAND TEST VOLTAGE 2.5 kv, FOR MINUTE F CONTACTORS TYPE AIR BREAK 2 MAKE L&T / SIEMENS/ SCHNEIDER 3 DUTY CLASS AC3 / AC4 4 RATING.2 TIMES MOTOR FULL LOAD CURRENT G COMPONENTS MAIN BUSBARS (PHASE & NEUTRAL)AND RISERS. MATERIAL TINNED COPPER.2 HEAT SHRINKABLE PVC SLEEVE REQUIRED / NOT REQUIRED.3 RATING * AMPS.4 MAIN BUSBAR POSITION TOP ( INCLUDING NEUTRAL BUSBAR).5 MATERIAL OF BUSBAR SUPPORT DMC / SMC / CAST EPOXY 2 EARTH BUS : 2. MATERIAL COPPER 2.2 MIN. SIZE 50 X 6 mm 3 ISOLATORS : PROVISION OF PADLOCKING REQUIRED / NOT REQUIRED IN OPEN & CLOSED POSITION OF THE ISOLATORS. 4 C.B. OPERATING MECHANISM : ( a ) CLOSING INDEPENDENT MANUAL SPRING CLOSING (IMS) MOTOR WOUND STORED CHARGE SPRING CLOSING (MWS) ( b ) TRIPPING SHUNT TRIP / MANUAL TRIP X:\STD\FORMS\E04-002A_Rev REV. 0 PAGE : 2 OF 5 APPLICABLE STANDARD SPECIFICATION :44LK-500/E.02/002 003

44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV G COMPONENTS (CONTD...) 5 ACCURACY CLASS OF INSTRUMENTS : ( a ) AMMETERS ( b ) KWh METERS / PF METERS 0.5 6 INDICATING INSTRUMENTS - SIZES INCOMING 44 MM.², OUTGOING 96 MM.² 7 CABLE ENTRY : INCOMING TOP / BOTTOM : OUTGOING TOP / BOTTOM 8 CABLE GLANDS : TO BE / NOT TO BE SUPPLIED TYPE : NICKLE PLATED BRASS DOUBLE COMPRESSION TYPE 9 CABLE LUGS : TO BE / NOT TO BE SUPPLIED TYPE : 0 SPACE HEATERS : REQUIRED / NOT REQUIRED VOLT : 240 V AC PAINTING ( TYPE & SHADE ) : EPOXY BASED PAINT & SHADE NO.63 AS PER IS5. H AUDIO / VISUAL ALARM SYSTEM REQUIRED / NOT REQUIRED WITH ANNUNCIATOR WINDOWS, DETAILS SPECIFIED ELSEWHERE. PUSH BUTTONS, HOOTER ETC. I DRAWINGS & OTHER INFORMATION AS SPECIFIED ELSE WHERE IN FEED DOCUMENT J NAME PLATE DETAILS * K INSPECTION & APROVAL AS SPECIFIED ELSE WHERE IN FEED DOCUMENT L FEEDER DETAILS * M NOTES & ADDITIONAL REQUIREMENTS X:\STD\FORMS\E04-002A_Rev REV. 0 PAGE : 3 OF 5 APPLICABLE STANDARD SPECIFICATION :44LK-500/E.02/002 003

44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV PART- B : PERFORMANCE PARTICULARS (TOBE FURISHED BY MANUFACTURER) SWITCHBOARD GENERAL. NAME OF MANUFACTURER *.2 MANUFACTURER'S TYPE DESIGNATION *.3 TYPE (DRAWOUT / NON DRAWOUT) *.4 DEGREE OF PROTECTION *.5 AVAILABILITY OF TYPE TEST * YES / NO CERTIFICATE FOR TEMPERATURE RISE AND SHORT TIME RATINGS OF SWITCHBOARD.6 RATINGS AND MAKES OF COMPONENTS * YES / NO AS PER JH&G SPECIFICATION.7 OGA, FOUNDATION AND CABLE CUTOUT / * YES / NO BUS DUCT ENTRY DRAWINGS SUBMITTED.8 OVERALL DIMENSIONS OF PCC / MCC * (L x W x H) IN MM.9 WEIGHT OF PANEL PER SHIPPING SECTION *.0 PAINTING TYPE AND SHADE * 2 CIRCUIT BREAKER DETAILS 2. MAKE OF CIRCUIT BREAKER * 2.2 NUMBER OF POLES * 2.3 RATED CURRENT (In) AT 50 / 60Hz * A 2.4 DERATED CURRENT RATING AT ( C) OF * A CIRCUIT BREAKER IN SWITCH BOARD AT 50/60 Hz 2.5 RATED OVERALL VOLTAGE (Ue) AT 50 / 60 Hz * V 2.6 RATED IMPULSE WITHSTAND VOLTAGE (Uimp) a) MAIN CONDUCTING PATH * kv b) AUXILIARY CIRCUITS * kv 2.7 UTILISATION CATEGORY * 2.8 RATED SHORT CIRCUIT MAKING CAPACITY (Icm) * ka (PEAK) 2.9 RATED SERVICE SHORT CIRCUIT BREAKING * ka (RMS) CAPACITY (Ics) 2.0 RATED ULTIMATE SHORT CIRCUIT BREAKING * ka (RMS) CAPACITY (Icu) 2. RATED SHORT TIME WITHSATND CURRENT (Icw) * ka (RMS) FOR SEC 2.2 NUMBER OF OPERATING CYCLES a) NUMBER OF OPERATING * CYCLES PER HOUR X:\STD\FORMS\E04-002A_Rev REV. 0 PAGE : 4 OF 5 APPLICABLE STANDARD SPECIFICATION :44LK-500/E.02/002 003

44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV b) NUMBER OF OPERATING * CYCLES (TOTAL) 3 BUSBARS DETAILS 3. MATERIAL * 3.2 SIZE AND NOS. a) PHASE * b) NEUTRAL * c) EARTH * 3.3 HEAT SHRUNK PVC SLEEVING PROVIDED * YES / NO 3.4 TEMPERATURE RISE OVER ( 47 C) AMBIENT * 3.5 MATERIAL OF BUSBAR SUPPORT * 3.6 BUSBARS SIZING CALCULATION SUBMITTED * YES / NO 4 DETAILS OF COMPONENTS 4. SWITCH DISCONNECTOR FUSE * 4.. MAKE * 4..2 COMPLIANCE TO 44LK500-ESS-02 * YES / NO 4..3 COMPLIANCE TO IS 3947 (PART-3) * YES / NO 4.2 MCCB 4.2. MAKE * 4.2.2 COMPLIANCE TO 44LK500-ESS-02 * YES / NO 4.2.3 COMPLIANCE TO IS 3947 (PART-2) * YES / NO 4.3 MPCB 4.3. MAKE * 4.3.2 COMPLIANCE TO 44LK500-ESS-02 * YES / NO 4.3.3 COMPLIANCE TO IS 3947 (PART-2) * YES / NO 4.4 OVERLOAD RELAY 4.4. MAKE 4.4.2 COMPLIANCE TO 44LK500-ESS-02 * YES / NO 4.4.3 COMPLIANCE TO IS 3947 (PART 4) * YES / NO 4.5 MOTOR PROTECTION RELAY 4.5. MAKE * 4.5.2 COMPLIANCE TO 44LK500-ESS-02 * YES / NO 4.5.3 COMPLIANCE TO IS/IEC - SPECIFY * 4.6 THERMISTOR RELAY 4.6. TYPE * 4.6.2 MAKE * 4.6.3 RATING * * - BOILER PACKAGE VENDOR TO SPECIFY X:\STD\FORMS\E04-002A_Rev REV. 0 PAGE : 5 OF 5 APPLICABLE STANDARD SPECIFICATION :44LK-500/E.02/002 003