Miniature Regulator Series 00F Compact and lightweight ( g) Low cracking pressure 0.0 MPa Standard model equipped with backflow function Standard Specifications Port size Fluid side side (Applicable tubing O.D.) Proof pressure Maximum operating pressure Regulating pressure range Ambient and fluid temperature Construction Weight (kg) Cracking pressure (Valve) 00F M (Male thread) Note) Applicable tubing material Nylon, Soft nylon, Polyurethane Note) e sure to note the maximum operating pressure for soft nylon and polyurethane. (Refer to est Pneumatics No..) Air. MPa 0.0 MPa Max. effective area ( ).8 mm ø 0.8 MPa Standard: 0. to 0.7 MPa 0. MPa setting 0.0 to 0. MPa 0.0 to 0 C (No freezing) Relieving type ø 0.0 00F-M-0 00F-M-0 Accessory (Option)/Part No. Description Manifold base 0 0 F How to Order M 0 Part no. M0-, -, -0 M0- Symbol Miniature regulator ody size 0 M Flow Characteristics (Representative values) Piping 0 Elbow type M M x 0.8 With One-touch fitting Pressure Characteristics (Representative values) Semi-standard 0.7 MPa setting (Standard) 0. MPa setting Note) Compared with standard specifications, its adjusting spring has only been changed. It is not the product which does not allow the pressure more than 0. MPa. Adjusting spring is not replaceable. Applicable tubing O.D. 0 mm 0 mm Conditions (Initial setting) Outlet pressure: 0. MPa Flow rate: 0 L/min (ANR) Note) A standard model is equipped with a backflow function. A main valve opens when the inlet pressure is released, and then an outlet pressure backflows into the inlet side. Initial set point 0 Inlet pressure (MPa)
Miniature Regulator Series 00F Construction/Dimensions Component Parts Lock nut M8 x 0.7 Panel screw Applicable tubing O.D. C No. Description Material Note 7 0 ody Valve guide Piston onnet Handle Adjusting spring Valve Nipple PT Polyacetal Steel wire Rubber lining Dimensions A 00F-M-0 00F-M-0 0..8 Manifold ase (Option)/Dimensions (00F-M-0) (00F-M-0) C x ø. (Mounting hole) D M x 0.8 Replacement Parts Panel mounting hole Max..t No. Description Material Part no. 7 8 9 Valve Gasket Spring, HNR Stainless steel NR Stainless steel -0# P0-0 When replacing valves and springs, remove nipple first. Note that adhesive is applied to the nipple portion. E F 0. (Width across flats: 0) G. H. Applicable tubing O.D. ø, ø J 0 K 7. Precautions e sure to read before handling. Refer to front matter for Safety Instructions and pages to 9 for Precautions on every series. Piping. To connect the side, hold the valve guide at its wrench flats (opposite side 0) and tighten it at the recommended torque of. to N m. Excessive torque or holding it at an area other than the specified portion may result in a malfunction.. While piping to products or operating the handle, ensure that an excess bending moment should not be applied to a product, because it may result in damage. Mounting/Adjustment. Set up the regulator while verifying the pressure that is indicated on the inlet and the outlet pressure gauges. Turning the handle excessively could damage the internal parts. Caution. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate. <Lock operating method> Loosen the lock nut to unlock it, and tighten it to lock it.. This product can be used as a check regulator by installing it between solenoid valve and actuator. AR VY T AP00 x /8 (Common) x ø. (Mounting hole) Manifold base part no. M0- M0- M0-0 A Stations dimension 0 90 0 0 dimension 8 0
Miniature Regulator Series 0 Lightweight body made of aluminum (0 g) Two styles of piping connections provided for the side: /8 (male thread) and M (female thread) Standard Specifications side side Fluid Proof pressure Maximum operating pressure Regulating pressure range Pressure gauge port size Ambient and fluid temperature Weight (kg) 0-M /8 (Male thread), M x 0.8 (Female thread) M x 0.8 (Female thread pcs.) Air. MPa 0.8 MPa Standard: 0. to 0.7 MPa 0. MPa setting 0.0 to 0. MPa M x 0.8 (Female thread) to 0 C (No freezing) 0.0 0-M 0-MG Symbol Accessory (Option)/Part No. 8 Pressure gauge Note) G7-0-R Note) When ordering the pressure gauge, a socket assembly (88A) is required. When installing a pressure gauge, the socket assembly must be fixed and installed to prevent the thread from breaking. 0. MPa specification is not available for G7. 0 M G Miniature regulator ody size 0 Relieving type (Standard) 8 (Male thread) M M x 0.8 (Female thread) M x 0.8 (Female thread) Flow Characteristics (Representative values) How to Order Accessory Note) Symbol Description G With bracket With pressure gauge Note) ackflow function is not available for standard. X09 is with backflow function. A main valve opens when the inlet pressure is released, and then an outlet pressure backflows into the inlet side. X09 is a product with pressure gauge (G7-0-M-X0). The symbol G for accessory is not necessary. Pressure Characteristics (Representative values) Made to Order None (Standard) X09 With backflow function Semi-standard 0.7 MPa seting (Standard) 0. MPa seting S With seal Note ) Compared with standard specifications, its adjusting spring has only been changed. It is not the product which does not allow the pressure more than 0. MPa. Adjusting spring is not replaceable. Conditions (Initial setting) Outlet pressure: 0. MPa Flow rate: 0 L/min (ANR) Initial set point Inlet pressure (MPa)
Miniature Regulator Series 0 Construction/Dimensions Precautions No. 80 8. 0 Pressure gauge (Option) x ø. ø Description ody Valve guide Piston Adjusting screw Adjusting spring (Width across flats) (7) R /8 8. A Material Aluminum alloy POM Iron Steel wire 9 M x (Option) M x 0.8 Hexagon nut x M x 0.8. Max. t Panel mounting hole View A Note lack anodized Nickel plated e sure to read before handling. Refer to front matter for Safety Instructions and pages to 9 for Precautions on every series. Selection. This product cannot be used as a check regulator by installing it between solenoid valve and actuator. Doing so could lead to equipment damage.. When connecting a pipe to the side, hold the valve guide at its wrench flats (opposite side ), and when connecting to the side, hold the body at its hexagon portion and tighten it to the recommended torque. (M:. to N m, R /8: 7 to 9 N m.) Excessive torque or holding it other than at the specified area could lead to equipment damage.. While piping to products or operating the handle, ensure that an excessbending moment should not be applied to a product, because it may result in damage. Mounting/Adjustment. Set up the regulator while verifying the pressure that is indicated on the inlet and the outlet pressure gauges. Turning the handle excessively could damage the internal parts. Caution. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate. <Lock operating method> Loosen the lock nut to unlock it, and tighten it to lock it.. This product cannot be used as a check regulator by installing it between solenoid valve and actuator.. Port with a pressure gauge or a plug can be used as an port. Maintenance. Make sure to perform a periodic inspection of the pressure gauge when the miniature regulator is installed between a solenoid valve and an actuator. Sudden pressure changes could happen and the durability of the product could be reduced. Using an electronic style pressure gauge is recommended, depending on the situation. AR VY T AP00
Miniature Regulator Series 0 Compact and lightweight (Main body g) 8. Improved flow characteristics 0.7 0. 0. 0. 0. 0. 0. 0.0 0 00 00 00 00 00 Allows smaller mounting pitch 8.8 mm 0-M 0-0 Accommodates two types of threads Inside: Female thread (M x 0.8) Outside: Male thread (/8) AR VY T AP00 8. 0-0G Panel mounting type uilt-in One-touch fitting ø, ø (Metric size) ø/", ø/" (Inch size)
Miniature Regulator Series 0 Standard Specifications Pressure gauge port size Fluid Proof pressure Maximum operating pressure Regulating pressure range Ambient and operating temperature range Weight Rc /8, NPT /8 (Female thread) Air. MPa 0.8 MPa Standard: 0. to 0.7 MPa, Low pressure use (0. MPa setting): 0.0 to 0. MPa to 0 C (No freezing) Approx. g Symbol 0-0 0-N0 0F-0-0 0F-0-0 0F-N0-0 0F-N0-07 M x 0.8 female thread is cut inside the pipe. Accessory (Option) Part No. R/8, M x 0.8 NPT/8, M x 0.8 R/8, M x 0.8 NPT/8, M x 0.8 Rc /8 NPT /8 ø One-touch fitting ø One-touch fitting ø/" One-touch fitting ø/" One-touch fitting 8 Pressure gauge Note) G-0-0(Rc/8)/G-P0-N0(NPT/8) Note) Pressure gauges (G) for 0. MPa are not available. How to Order With One-touch fitting 0 F 0 G 0 Thread type N R, Rc NPT 0 0 ody size 0 Relieving type With One-touch fitting () 0 /8 (Male thread), M x 0.8 (Female thread) G (, ) 0 Accessory None Pressure gauge G Note ) For products with pressure gauge, pressure gauge is shipped together with product. /8 (Male thread), M x 0.8 (Female thread) /8 (Female thread) Semi-standard S 0.7 MPa setting (Standard) 0. MPa setting Note ) With seal Applicable tubing O.D. () Metric size 0 mm 0-0 0 mm Inch size 0 07 /" /" 0F-N0 Made to Order Refer to page 8 for details. Note ) Compared with standard specifications, its adjusting spring has been only changed for 0. MPa. It is not the product which does not allow the pressure more than 0. MPa. Adjusting spring is not replaceable. esides, in the case with the pressure gauge, the pressure gauge will be the one for MPa.
Miniature Regulator Series 0 Flow Characteristics (Representative Values) 0-0 0F-0-0 0.7 0.7 0F-0-0 0.7 0. 0. 0. 0. 0. 0. 0.0 0 00 00 00 00 00 00 Pressure Characteristics (Representative Values) Construction 0-0 9 0.0 0. 0.0 0. 0.0 0. 0. 0. 0. 0. 0.7 0.8 0.9 Inlet pressure (MPa) 0. 0. 0. 0. 0. 0. 0.0 0 00 00 00 00 00 00 Set point 8 7 0 Conditions: Inlet pressure 0.7 MPa Outlet pressure 0. MPa Flow rate Q = 0 L/min (ANR) F0F-0 Component Parts No. 7 8 9 0 7 7 Description ody Valve guide onnet Piston Valve Adjusting screw Panel nut Hexagon nut Adjusting spring Valve spring Spring holder Mini Y-seal O-ring Lock washer Pressure gauge Cassette 0. 0. 0. 0. 0. 0. 0.0 0 00 00 00 00 00 00 Material Aluminum alloy POM Iron Iron Iron Steel wire Stainless steel Steel band NR NR SS Steel band POM, Stainless steel Note Rubber lining material: HNR Nickel plated Electrophoretic painting Accessory Accessory 7 AR VY T AP00
Series 0 Dimensions 0-0 0F-0 9 7 M x Panel cutout dimensions ø./panel thickness: or less 8. 7. 8. x ø. Rc, NPT /8 Applicable tubing O.D. Metric size ø, ø Inch size ø/", ø/" (Width across flats) Pressure gauge port size Rc, NPT /8 M x 0.8 (Female thread) 8. R, NPT/8... Made to Order Specifications Consult with SMC for detailed dimensions, specifications and delivery. For moderate pressure (0. MPa Setting): Compared with standard specifications, its adjusting spring has been only changed for 0. MPa. It is not the product which does not allow the pressure more than 0. MPa. Adjusting spring is not replaceable. 0 8 0 Relieving type ody size /8 (Male thread), M x 0.8 (Female thread) /8 (Female thread) How to Order 0 0 X0 (.) N Thread type R, Rc NPT Accessory None Made to Order X0 0. MPa Setting (For moderate pressure) Semi-standard S 0.7 MPa setting (Standard) 0. MPa setting Note) With seal Note ) Compared with standard specifications, its adjusting spring has been only changed for 0. MPa. It is not the product which does not allow the pressure more than 0. MPa. Adjusting spring is not replaceable.
Series 0 Specific Product Precautions e sure to read before handling. Refer to front matter for Safety Instructions and pages to 9 for Precautions on every series. Design and Selection. This product cannot be used as a check regulator by installing it between solenoid valve and actuator. It can result in causing breakdown and malfunction.. When piping, tighten the regulator with the recommended proper tightening torque (M:. to N m, R /8: 7 to 9 N m) while holding the wrench flats (width ) of the valve guide for port and holding the hexagonal section of the body for the port. Excessive tightening or holding a part other than those specified can cause damage.. While piping to products or operating the handle, ensure that an excess bending moment should not be applied to a product, because it may result in damage. Caution Mounting To set the correct pressure. Make connections after confirming the mark which indicates the air inlet. Reversed connections can cause malfunction. AR VY T AP00 9