ANTI-SYPHON VALVE INSTALLATION GUIDE

Similar documents
PMA INTAKE FILTER SCREEN INSTALLATION GUIDE

FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE

FLEX-ING TM DISPENSER HOSES INSTALLATION GUIDE

RIGID ENTRY BOOT INSTALLATION GUIDE

EVO TM 200 AND EVO TM 400 LCD DISPLAY INSTALLATION GUIDE

ADJUSTABLE ROTARY SCRAPER TOOL SCR USER S GUIDE

DIESEL EXHAUST FLUID PUMPING ACCESSORIES INSTALLATION GUIDE

COMPOSITE ACCESS COVER INSTALLATION GUIDE

SEALING DIP CAP INSTALLATION GUIDE

DIESEL EXHAUST FLUID PUMP MOTOR ASSEMBLY REPLACEMENT GUIDE

FLEX PROBE INSTALLATION AND PROGRAMMING GUIDE

DEFENDER SERIES OVERFILL PREVENTION VALVE INSTALLATION GUIDE

DEFENDER SERIES BELOW GRADE DOUBLE WALL SPILL CONTAINER INSTALLATION GUIDE

SMART CONTROLLER I INSTALLATION GUIDE

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

DC400 Dispensing Cutoff System

STP-MLD Installation and Owner s Manual

STP-MLD+ Installation and Owner s Manual. Manual # Revision Date Changes from previous revision

High Capacity Submerged Turbine Pumps

STP-DHI DISPENSER HOOK ISOLATION STP-DHI 120 Volt Hook STP-DHIB 240 Volt Hook

STP-MLD. Installation and Owner s Manual

STP / IST Fixed & Variable Length

Pro 30 Gas Caddy. Model FC-P30-UL Operator s Manual. JohnDow Industries, Inc. 151 Snyder Ave. Barberton, OH 44203

DEFENDER SERIES. 5 Gallon, Single Walled, Field Replaceable Spill Container Fiberglass Model Series INSTALLATION, OPERATION, & MAINTENANCE

Vapor Recovery Assist System

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

IMPORTANT SAFETY NOTICE

Blizzard, PO Box , Milwaukee, WI B31184 UNDERCARRIAGE KIT. Ford F

B32207 UNDERCARRIAGE KIT. Parts List and Installation Instructions CAUTION. Read this document before installing the snowplow.

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

IMPORTANT INFORMATION

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

UNDERCARRIAGE KIT. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL

Installation. Introduction

Blizzard, PO Box , Milwaukee, WI B32214 UNDERCARRIAGE KIT. Dodge Dakota Dodge Durango

Pro 30 Plus Gas Caddy

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

STP SUBMERGED TURBINE PUMP IST INTELLIGENT SUBMERSIBLE TURBINE. Variable Length

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5

Galaxy Receiving and Unpacking 09/

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

Galaxy VM. Battery Breaker Box Installation 09/

Safety Precaution. Notation. Meaning of symbols WARNING CAUTION

Pressurized oil drain for collection of used lubricants and anti-freeze.

Series K Pneumatic Switch Mechanism

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems

Propane torch. Model Assembly And Operation Instructions

Battery Desktop Charger Operation Manual Northridge Dr. N.W. Suite 1 Walker, MI _REV.

Effective November 2016 Supersedes September 1998 (S )

DIAGNOSTIC TOOL BATTERY

INSTALLATION GUIDE FUELTEC- FUEL POLISHING SYSTEM

Dispenser Pan Sensors & Containment Sump Sensors

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

THE SUBMERGED PUMP SYSTEM SUPPLYING THE DISPENSERS MAY TURN ON UNEXPECTEDLY TO PERFORM A LINE LEAK TEST. THIS MAY RESULT

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

PROPANE TORCH WITH TURBO BURNER

STEP-BY-STEP INSTALLATION GUIDE

RECEIVER MOUNT KIT LP-8 Tailgate Spreaders

OMEGA CORDLESS SERIES VACUUM INSTRUCTION MANUAL

IMPORTANT INFORMATION

Intended Users This manual is meant for Gasboy Authorized Service Contractors (ASCs) who will install this kit on Atlas units.

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

BroadBand PowerShield. 20 AHr Battery. User Manual

Introduction. Caution. This manual provides installation instructions for installing the Atlas Discharge and Valve Conduit Retrofit Kit.

Owner s Manual GLASSLINED PUMP TANK

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Intended Users This document is intended for Gasboy-certified Authorized Service Contractors (ASCs) and Customer Specified Contractors (CSCs).

OPERATION MANUAL, POWER MODULE-CHARGER SYSTEM. Man Occup. Machine Occup. Cycle Time Setup Time Batch Qty. Equipment Manufacturer Qty

en Vibroplate VP 1550 (RAW) OPERATOR S MANUAL

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

Nickel Catalyst Tube on a 6820 GC, Accessory G4318A

Vapor Recovery Central Vacuum System

UPP Polyethylene Dispenser Sump

Purpose This document provides installation instructions for the Gasboy 9820 Pump Interface Kit.

Owner s Manual & Safety Instructions

M Series External Battery Frame. User Guide

MOUNT KIT. Polaris Ranger Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

MR 5-30 Aviation Fuel Meter Owner s Manual

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

Western Products, PO Box , Milwaukee, WI MOUNT KIT

Installation and Operating Manual

PRODIGY & PRO PLUS Skid Steer Snowplows

Effective November 2016 Supersedes February 2012 (S )

3 Phase Smart Controller

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Conduit Rigid Entry Boots

MOUNT KIT. Kubota RTV 900, 1140 Kubota RTV X-Series. Installation Instructions CAUTION. Read this document before installing the snowplow.

Installation Manual Stand-Alone Dispenser Pan Sensor

FIRESAFE & LETHAL SERVICE BALL VALVE CATALOGUE //

Mount Kit. Chevy/GMC 1500HD/2500/3500 4X Chevy/GMC Suburban 2500 Yukon XL Installation Instructions CAUTION

Model 1000 Low Profile Tailgate Spreader Receiver Mount

Western Products, PO Box , Milwaukee, WI MOUNT KIT. Installation Instructions CAUTION

Viscount I Hydraulic Motor and Displacement Pump

Blizzard, PO Box , Milwaukee, WI B35126 UNDERCARRIAGE KIT. John Deere Gator XUV/HPX. Installation Instructions

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

Tuffy Liquid Level Controls with Pneumatic Switch

Transcription:

ANTI-SYPHON VALVE INSTALLATION GUIDE

The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information contained in this manual at the time of printing, we recommend that you refer to franklinfueling.com for the most current version of this manual. All product specifications, as well as the information contained in this publication, are subject to change without notice. Franklin Fueling Systems does not assume responsibility and expressly disclaims liability for loss, damage, or expense arising out of, or in any way connected with, installation, operation, use, or maintenance by using this manual. Franklin Fueling Systems assumes no responsibility for any infringement of patents or other rights of third parties that may result from use of this manual or the products. We make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Copyright 2017 Franklin Fueling Systems, Madison, WI 53718. All world rights reserved. No part of this publication may be stored in a retrieval system, transmitted, or reproduced in any way, including, but not limited to, photocopy, photograph, magnetic, or other record, without the prior written permission of Franklin Fueling Systems. For technical assistance, please contact: Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Web: franklinfueling.com Telephone: USA and Canada: +1.608.838.8786, +1.800.225.9787 USA and Canada Technical Support: +1.800.984.6266 UK: +44 (0) 1473.243300 Mexico: 001.800.738.7610 France: +33 (0) 1.69.21.41.41 China: +86.10.8565.4566 F-1674 r3

Contents Introduction...1 Conventions used in this manual...1 Questions and concerns...1 Operating precautions...2 Installation...3 Installing the Anti-Syphon Valve...3 Adjustment table...5

Intentionally Blank

Introduction The Remote Fill Splice Kit is designed to allow you to fill a tank through a remote fill tube. The splice is installed in the drop tube and provides openings for fuel to pass through and into a tank. Conventions used in this manual This manual includes safety precautions and other important information presented in the following format: NOTE: This provides helpful supplementary information. IMPORTANT: This provides instructions to avoid damaging hardware or a potential hazard to the environment, for example: fuel leakage from equipment that could harm the environment. CAUTION: This indicates a potentially hazardous situation that could result in minor or moderate injury if not avoided. This may also be used to alert against unsafe practices. WARNING: This indicates a potentially hazardous situation that could result in severe injury or death if not avoided. DANGER: This indicates an imminently hazardous situation that will result in death if not avoided. Questions and concerns In case of emergency, follow the procedures established by your facility. If you have questions or concerns about safety or need assistance, use the information below to contact Franklin Fueling Systems: Web: franklinfueling.com Telephone: USA and Canada: +1.608.838.8786, +1.800.225.9787 USA Technical Support: 1.800.984.6266 UK: +44 (0) 1473.243300 Mexico: 001.800.738.7610 France: +33 (0) 1.69.21.41.41 China: +86.10.8565.4566 1

Operating precautions Franklin Fueling Systems (FFS) equipment is designed to be installed in areas where volatile liquids such as gasoline and diesel fuel are present. Working in such a hazardous environment presents a risk of severe injury or death if you do not follow standard industry practices and the instructions in this manual. Before you work with or install the equipment covered in this manual, or any related equipment, read this entire manual, particularly the following precautions: IMPORTANT: To help prevent spillage from an underground storage tank, make sure the delivery equipment is well-maintained, that there is a proper connection, and that the fill adaptor is tight. Delivery personnel should inspect delivery elbows and hoses for damage and missing parts. CAUTION: Use only original FFS parts. Substituting non-ffs parts could cause the device to fail, which could create a hazardous condition and/or harm the environment. WARNING: Follow all codes that govern how you install and service this product and the entire system. Always lock out and tag electrical circuit breakers while installing or servicing this equipment and related equipment. A potentially lethal electrical shock hazard and the possibility of an explosion or fire from a spark can result if the electrical circuit breakers are accidentally turned on while you are installing or servicing this product. Refer to this manual (and documentation for related equipment) for complete installation and safety information. WARNING: Before you enter a containment sump, check for the presence of hydrocarbon vapors. Inhaling these vapors can make you dizzy or unconscious, and if ignited, they can explode and cause serious injury or death. Containment sumps are designed to trap hazardous liquid spills and prevent environmental contamination, so they can accumulate dangerous amounts of hydrocarbon vapors. Check the atmosphere in the sump regularly while you are working in it. If vapors reach unsafe levels, exit the sump and ventilate it with fresh air before you resume working. Always have another person standing by for assistance. WARNING: Follow all federal, state, and local laws governing the installation of this product and its associated systems. When no other regulations apply, follow NFPA codes 30, 30A, and 70 from the National Fire Protection Association. Failure to follow these codes could result in severe injury, death, serious property damage, and/or environmental contamination. WARNING: Always secure the work area from moving vehicles. The equipment in this manual is usually mounted underground, so reduced visibility puts service personnel working on it in danger from moving vehicles that enter the work area. To help prevent this safety hazard, secure the area by using a service truck (or some other vehicle) to block access to the work area. WARNING: Discharge static electricity from the product before you install it, and make sure it is properly grounded while in service. WARNING: Make sure you check the installation location for potential ignition sources such as radio waves, ionizing radiation, and ultrasound sonic waves. If you identify any potential ignition sources, you must make sure safety measure are implemented. 2

Installation Installing the Anti-Syphon Valve 1. Determine the correct head height. Measure from the top of the fuel tank to the lowest run between the anti-syphon valve and the pump. Anti-Syphon Valve Head Height Block Valve Shear Section Pressure Regulator Valve Grade Level 2. Order the corresponding part whose head range covers that of the measured site. 3. Install the inlet from the tank in the vertical axis (in line with adjustment head). 4. Install the outlet to the pump on the horizontal axis (perpendicular with inlet). 3

5. Valves as supplied are set to the maximum head. If necessary, adjust the valve to the desired head. Refer to the table on the second page for setting dimensions. Adjusting Screw Outlet to Pump Inlet from Tank NOTE: Apply a non-hardening, gasoline resistant pipe dope to the threads of both the inlet and outlet to get a proper seal. 4

Adjustment table This table lists the turns from the factory setting. Ft. of Head Valve Size and Model Number ¾" 1" 1½" 2" 60530001 60630001 61630001 61630002 61630003 63630011/31 63630012/32 1 6¼ 6¼ 5½ 2 6¼ 6¼ 4¼ 3 6¼ 6¼ 3 4 6 6 1½ 5 5¼ 5¼ 6 Factory Setting* 5 6 4½ 4½ 5¼ 4½ 7 3¾ 3¾ 4½ 3¾ 8 3 3 3½ 3 9 2¼ 2¼ 2¾ 2¼ 10 1½ 1½ 1 ¾ 1½ 11 ¾ ¾ 1 ¾ 12 Factory Factory Factory Factory 6 Setting* Setting* Setting* Setting* 5¼ 13 5½ 4¾ 14 5¼ 4½ 15 4¾ 4¼ 16 4¼ 3¾ 17 3¾ 3¼ 18 3¼ 3 19 2¾ 2¾ 20 2¼ 2¼ 21 1¾ 1¾ 22 1½ 1½ 23 1 1 24 ½ ½ 25 Factory Factory Setting* Setting* * Valves ship at the factory setting, where the adjustment screw and nut are bottomed out so the retaining ring is in contact with the nut on top of the valve. 5

Intentionally Blank

Intentionally Blank

A Franklin Fueling Systems Brand F-1674 r3