Finger Valve Series RoHS Large effective area:.0 to 7.5 mm Small knob operating force: 0.04 to 0.4 N m Poppet valve construction seldom suffers seal defection. The series begins with the min. tubing O.D. of. Selection from four types in accordance with the piping specifications The port valve discharges residual pressure from (A) with the handle set at SHUT. (There is no exhaust port.) Specifications Valve Fluid Proof pressure Max. operating pressure () Operating vacuum pressure Ambient temperature and operating fluid temperature material () Accessory (Option) Note ) Please note that when the valve is used at micro pressures of 0. MPa or less, valve leakage may be more than the standard value (5 cm /min). Note ) Use caution about the maximum operating pressure when soft nylon or polyurethane tubing is used. (Refer to Best Pneumatics No. 6 for details.) * Use ( port valve) for vacuum application. Construction / port valves Air.5 MPa.0 MPa 00 kpa 0 to 60 C Nylon, Soft nylon, Polyurethane port valve: Series port valve: Series w o q r t e The valve direction clearly indicates whether the valve is open or closed. (SHUT-OPEN: Counterclockwise) OPEN Symbol 90 port valve port valve (A) (A) (P) SHUT port valves and port valves can be distinguished by the color of their knobs. (R) Exhaust 80 Knob: port valve: (46) port valve: (46-) / port valve: (46-)... (Option) Exhaust (R) (P)(R) Component Parts No. 4 5 6 7 8 9 0 Replacement Parts Knob Description Body Knob Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette Description Standard type! i u y Model One-touch fitting One-touch fitting O.D. or less O.D. ø0 or more (P)-Male thread (A)-Male thread /8 or more Part no. 46 46-46- 46-46-4 Flame resistant type 46-5 assembly Note ) -BA Note ) -BANote ) Note ) For details on selection of each bracket assembly part no., refer to the tables on page 8. Note ) The bracket, bolts, nuts, and washers are supplied with the bracket assembly.!0 Material Standard type PBT Flame resistant type Flame resistant PBT (UL standard V-0) Standard type POM Flame resistant type Flame resistant PBT (UL standard V-0) Flame resistant CR (UL standard V-0) POM POM Brass Electroless nickel plated Stainless steel NBR NBR HNBR Standard type POM Flame resistant type Flame resistant PBT(UL standard V-0) Note Applicable to the flame-resistant cover only
Finger Valve Series How to Order Standard type Flame resistant type 0S 0S R 04F 04F Made to Order Refer to page 86 for details port valve port valve Flame resistant type (P) port size 04F 06F 08F 0F F 0S 0S 0S 04S ø0 ø x 0.8 R 8 R R 8 R (A) port size 04F 06F 08F 0F F 0S 0S 0S 04S ø0 ø x 0.8 R 8 R R 8 R Nil None L With L-bracket and screws Flame resistant cover Nil No With cover C (For One-touch fitting only) Nil port valve (Standard) port valve R port valve (Option) port valve Standard Type (P): One-touch fitting (A): One-touch fitting (A) O.D. (mm) (P) O.D. (mm) ø0 ø ø0 ø (P): Male thread (A): One-touch fitting (A) O.D. (mm) (A) (A) (P) ø0 ø (P) 8 8 (P) 8 8 Flame Resistant Type (UL-94 Standard V-0 equivalent) 8 8 (P): One-touch fitting (A): Male thread O.D. (mm) ø0 ø (P): Male thread (A): Male thread 8 8 VM VMG VR VR5 VH VHS VHS (P): One-touch fitting (A): One-touch fitting (P) O.D. (mm) (A) ø0 ø O.D. (mm) ø0 ø (P): Male thread (A): Male thread (A) (P) 8 8 8 8 8
Series (P)/(A): One-touch Fitting mounting dimensions O. D. (mm) Model H L L L L4 L5 L6 M M Q (P) (A) (A) (R) Note) (g) (P) (A) assembly no. 4 4-04F-04F 8 47.6.8.8 6.5.5 5.8 5.8 0.7 0.5 0.4 0.5 0.06 5 -BA 44.5 4.5 7 6.5 6 4-06F-04F 48.0 0.5 0. 0.5 0.06 6 8 4 6 48.6 4..7 6.5.5 6.8 5.8 5-06F-06F 4. 6.8.4 0.5 0.5 0.5 0.06 6 -BA 44.5 4.5 7 6.5 6 6-08F-06F 0.5 0.5 0.06 8 8 4 50.5 8 5.4 6. 4. 6.5.5 8.7 6.8 6-08F-08F 6. 8.7.9 0.5 0.9 0.5 0.06 7 -BA 44.5 4.5 7 6.5 6 8-0F-08F.7 0.5 0.55 7 0 46 58.5 0 6 0.5 8.5 4 0.8 8.7 8 4-0F-0F 0.5 0.8. 0.5 5 7 9 -BA 49 7 0 5.5 0 -F-0F 6. 0.5 8 7 46 6.5 0.5.5 4.8 0.8 4 -F-F.5.8.4 0.5 0.70 7 -BA 49 7 0 5.5 Note) port valve (P): Male Thread, (A): One-touch Fitting Connection S mounting dimensions thread R O. D. (mm) Model H L L L L4 L5 L6 M Q (P) (A) (A) (R) () () (Width (g) B across (P) (A) flats) assembly no. 4 --04F 5.9.8 9. 5.8 0.4 0.5 0.0 0.5 0.06 9 49 8 4 6.5.5 6 --06F 5.9 4. 9.6 6.8 0.4 0.5 0.0 0.5 0.06 50 -BA 44.5 4.5 7 6.5 6 4-0S-04F 55.4.8.6 5.8 0.7 0.5 0.7 0.5 0.06 5 8 6-0S-06F 8 4 56.9 4..6 6.5.5 6.8.4 0.5 0.5 0.5 0.06 5 -BA 44.5 4.5 7 6.5 6 8-0S-08F 6. 6. 6 8.7.9 0.5 0.47 0.5 0.06 58 7 8 6-0S-06F 60.4 4. 6. 6.8.4 0.5 0.5 0.5 0.06 8 4 6.5.5 65. 6. 9 8.7 54 4 -BA 44.5 4.5 7 6.5 6 8-0S-08F.9 0.5 0.47 0.5 0.06 59 7 0-0S-0F 7.8 0.5 4. 0.8. 0.5 0.78 7 46.5 4 76..5 44.8.8 4 49 68 9 -BA 49 7 0 5.5-0S-F.4 0.5 0.85 7 6 70 6-0S-06F 6.4 4. 8. 6.8.4 0.5 0.5 0.5 0.06 8 4 6.5.5 66. 6. 40 8.7 56 7 -BA 44.5.5 7 6.5 6 8-0S-08F.9 0.5 0.47 0.5 0.06 40 60 0-0S-0F 74.8 0.5 44. 0.8. 0.5 0.78 7 46.5 4 77..5 45.8.8 4 5 68 9 -BA 49 7 0 5.5-0S-F.4 0.5 0.85 7 64 7 0-04S-0F 78. 0.5 47.7 0.8. 0.5 0.78 7 46.5 4 80..5 48.7.8 4 7 70-04S-F.4 0.5 0.85 7 70 7 -BA 49 7 0 5.5 Note ) port valve Note ) Reference dimensions after insertion of R thread. 8
Finger Valve Series (P): One-touch Fitting, (A): Male Thread 50 Connection S mounting dimensions O. D. (mm) thread R Model H L L L L4 L5 L6 M Q (P) (A) (A) (R) () (Width (g) B () across (P) (A) flats) assembly no. 4-04F- 5.9 9. 0.4 0.5 0.08 0.5 0.08 9 49 8 4.8 6.5.5 5.8 8-04F-0S 55.4.6 0.7 0.5 0.4 0.5 0.08 5 -BA 44.5 4.5 7 6.5 6-06F- 5.9 9.6 0.4 0.5 0.08 0.5 0.08 6 8-06F-0S 56.9.6.4 0.5 0.5 0.5 0.08 5 8 4. 6.5.5 6.8-06F-0S 60.4 6..4 0.5 0.9 0.5 0.08 54 4 -BA 44.5 4.5 7 6.5 6 8 8-06F-0S -08F-0S 6.4 6. 8. 6.4.9 0.5 0.9 0.5 0.5 0.9 0.5 0.08 0.08 4 56 58 7 8-08F-0S 8 4 65. 6. 9 6.5.5 8.7.9 0.5 0.9 0.5 0.08 59 7 -BA 44.5 4.5 7 6.5 6 8-08F-0S 66. 40.9 0.5 0.9 0.5 0.08 40 60-0F-0S 7.8 4.. 0.5 5 7 0.9 68 9 0 8-0F-0S 46 74.8 0.5 44..5 4 0.8 4. 0.5 5 7 0. 5 -BA 49 7 0 5.5-0F-04S -F-0S 78. 76. 47.7 44.8..4 0.5 5 7 0.5 0.70 7 0. 0. 7 6 70 70 8 -F-0S 46 77..5 45.8.5 4.8 4.4 0.5 0.70 7 0. 64 7 -BA 49 7 0 5.5 -F-04S 80. 48.7.4 0.5 0.70 7 0. 70 7 (P)/(A): Male Thread Note ) port valve Note ) Reference dimensions after insertion of R thread. VM VMG VR VR5 VH VHS VHS Connection thread S T mounting dimensions R Model H L L L L4 L5 L6 Q (P) (A) (A) (R) () B (g) (Width (Width across across (P) (A) flats) flats) assembly no. -- 8 4 58. 9. 9. 6.5.5 0.4 0.5 0.08 0.5 0.06 5 -BA 44.5 4.5 7 6.5 6 8-0S- 6.6 9 0.4 0.5 0.08 0.5 0.06 6 54 8 4.6 6.5.5 8-0S-0S 65..6.6 0.5 0.5 0.5 0.06 0 57 -BA 44.5 4.5 7 6.5 6 8-0S-0S 7.6.6.8 0.5 0.7 0.5 0.06 9 6 8 4 9 6.5.5 7-0S-0S 78 9.9 0.5 0.9 0.5 0.06 47 66 7 -BA 44.5 4.5 7 6.5 6 8-0S-0S 85.0.8.7 0.5 0.56 7 65 7 7 46 44..5 4 4 9 8-0S-0S 88.6 44.. 0.5 6 7 7 76 9 -BA 49 7 0 5.5 8-04S-0S 9 44..8 0.5 7 90 79 9 46 48.7.5 4 4-04S-04S 97.4 48.7.4 0.5 0.7 7 0 8 -BA 49 7 0 5.5 Note ) port valve Note ) Reference dimensions after insertion of R thread. 8
Series / Precautions Be sure to read before handling. Refer to front matter 5 for Safety Instructions and pages to 8 for /4/5 Port Solenoid Valve Precautions. Warning Design. Please contact SMC when fluids other than air are used.. Do not supply air pressure from (A) port. The air will leak out from (P) port.. Since the valve allows a small volume of air leakage, it may not be suitable for holding pressure in a pressure vessel. Selection Operation method: The valve must be switched to OPEN or SHUT instantly and securely. Stopping the handle halfway between the extreme positions may cause malfunction. Piping Precautions for handling the male threads of the R pipe fitting with seal. Use a wrench to secure the hexagon portion to screw in the fitting. If the size of the wrench is not appropriate it will be stripped.. To screw in the fitting, first hand-tighten; then, use a tool to rotate it to turns. If it is tightened excessively, more sealing agent will be forced out. Therefore, make sure to remove the extra sealing agent.. Re-use of fittings: ) Ordinarily, the fitting can be reused to times. ) Before reusing the fitting, clear off the sealing agent that remains on the removed pipe fitting using an air blower. If the sealing agent is peeled off and enters the peripheral equipment, it can cause air leakage. ) If the sealing effect has been lost, wrap a seal tape over the sealing agent to reuse the fitting. Do not use any sealing agent other than seal tape. Mounting L type bracket mounting: Apply a tightening torque of 0.5 to N m to the bolts when the bracket is mounted on the body. One-touch Fitting. When tubing of brands other than SMC s are used, verify that the tubing O.D. satisfies the following accuracy; Nylon tubing Within ±0. mm Soft nylon tubing Within ±0. mm Polyurethane tubing Within +0. mm, 0. mm If the tube s external accuracy is not satisfied, it may not be possible to connect the tube. Even if it is connected, air leakage or tube disconnection may result. 84
Finger Valve Series Flame Resistant Type: (P)/(A): One-touch Fitting mounting dimensions O. D. (mm) Model H L L L L4 L5 L6 L7 Q M M (P) (A) (A) (R) S (g) (P) (A) assembly no. 4 4 R-04F-04F 8 47.6.8.8 6.5.5 5.6 5.8 5.8 0.4 0.5 0.4 0.5 0.08 5 ø4.4 -BA 44.5 4.5 7 6.5 6 6 6 R-06F-06F 8 48.6 4. 4. 6.5.5 5.6 6.8 6.8.4 0.5 0.5 0.5 0.08 6.8 -BA 44.5 4.5 7 6.5 6 8 8 R-08F-08F 8 4 5.4 6. 6. 6.5.5 56.4 8.7 8.7.9 0.5 0.9 0.5 0.08 7 ø9. -BA 44.5 4.5 7 6.5 6 0 0 R-0F-0F 46 6 0.5 0.5.5 4 65 4 0.8 0.8. 0.5 5 7 0. 9 ø. -BA 49 7 0 5.5 R-F-F 46 6.5.5.5 4 67 4.8.8.4 0.5 0.70 7 0. ø5.7 -BA 49 7 0 5.5 Flame Resistant Type: (P)/(A): Male Thread VM VMG VR VR5 VH VHS VHS Reference dimensions after insertion of R thread Connection S T mounting dimensions thread R Model H L L L L4 L5 L6 Q B (P) (A) (A) (R) (Width (Width (g) across across (P) (A) flats) flats) assembly no. 8 8 R-0S-0S 8 4 65..6.6 6.5.5 57.6 0.5 0.5 0.5 0.08 0 -BA 44.5 4.5 7 6.5 6 R-0S-0S 8 4 78 9 9 6.5.5 66.9 0.5 0.9 0.5 0.08 47 7 7 -BA 44.5 4.5 7 6.5 6 8 8 R-0S-0S 46 88.6 44. 44..5 4 4 76. 0.5 6 7 0. 7 9 9 -BA 49 7 0 5.5 R-04S-04S 46 97.4 48.7 48.7.5 4 4 8.4 0.5 0.7 7 0. 0 -BA 49 7 0 5.5 85
Series Made to Order Please contact SMC for detailed dimensions, specifications and lead times. IN/OUT Size: Altered /4" Valve X05 07F 07F X05 port valve port valve (P) port size: /4" (A) port size: /4" IN/OUT size: Altered /4" valve Nil None L With L-bracket and screws Nil port valve (Standard) port valve R port valve (Option) port valve IN/OUT Size: Altered 5/6" Valve X6 09F 09F X6 port valve port valve (P) port size: 5/6" (A) port size: 5/6" IN/OUT size: Altered 5/6" valve Nil None L With L-bracket and screws Nil port valve (Standard) port valve R port valve (Option) port valve IN/OUT Size: Altered /8" Valve X09 F F X09 port valve port valve (P) port size: /8" (A) port size: /8" Nil L and screws Nil port valve (Standard) port valve R port valve (Option) port valve None With L-bracket IN/OUT size: Altered /8" valve 86