G3141 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/G41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 JIS symbol G31/41: Universal type COM NO NC Common specifications Item Standard specifications Optional specifications Working fluid irflow, low vacuum (1.33 x 10 Pa (abs)), water, kerosene, oil (50 mm /s or less) ot water Steam Working pressure differential range MPa Max. working pressure MPa Withstanding pressure (water) MPa 0 to 1 (refer to max. working pressure differential in individual specifications.) 1 5 Fluid temperature (Note 1) C -10 to 60-10 to 90-10 to 4 mbient temperature eat proof class C -0 to 60-0 to 100 tmosphere Valve structure Place free of corrosive gas and explosive gas irect acting poppet structure Valve seat leakage cm 3 /min. (NR) 0. or less (air) 300 or less (air) Mounting attitude ody, sealant rass, nitrile rubber Free rass, ethylene propylene diene rubber rass, PTF Note 1: No freezing Individual specifications Item G31-01-1-01- -0-1 -0- G41-0-1-0- -03-1 -03- Port size Rc1/8 Rc1/4 Rc1/4 Rc3/8 Orifice (mm) TOP OY 1.5 1.5.0.0 1.5 1.5.0.0.0.0.3.3.0.0.3.3 Max. working pressure differential (MPa) ir Water, hot water, kerosene Oil (50 mm /s) Steam C C C C C C C 0.7 0.7 0.7 0.7 0.6 0.6 (0.5) 0.7 0. (0.35) 0.5 (0.15) 0.7 0.7 0.7 0.7 0.6 0.6 (0.5) 0.7 0. (0.35) 0.5 (0.15) 0.7 0.3 1.0 (5) 1.0 0.7 (0.5) 0.15 0.7 (0.5) 0.7 0.5 (0.1) 0.7 0.3 1.0 (5) 1.0 0.7 (0.5) 1.0 0.7 1.0 0.7 (0.5) 0.7 0.5 0.15 (0.1) 0.7 Rated voltage 100 VC 50/60 z 110 VC 60 z 00 VC 50/60 z 0 VC 60 z 1 VC 4 VC 48 VC 100 VC pparent power (V) Power consumption (W) olding Starting C C Weight (kg) 50 z 60 z 50 z 60 z 50/60 z 14 11 0 16 6/4. 11 (8.1) 0.36 5 11 17 35 7 8.3/6. (1) 8 *1: The model numbers above show the basic port size (Rc) and orifice diameter. Refer to ow to order for other combinations. *: Refer to C column for the max. working pressure differential of coil with diode. *3: The voltage fluctuation must be within ±10% of the rated voltage. *4: Values in ( ) are for the type with IN terminal box and C voltage specifications, and indicate the max. working pressure differential when pressurizing from the NO port. *5: When continuously energizing the valve, use a fluoro rubber seal. *6: When the sealant is PTF, the NO port cannot be pressurized. 166
G3141 Series Optional specifications (fluid temperature, ambient temperature, valve seat leakage) Sealant Coil (heat proof class) Fluid temperature (Note 1) C mbient temperature C Valve seat leakage cm 3 /min. (NR) Fluoro rubber thylene propylene diene rubber PTF -10 to 60-0 to 60-10 to 90-0 to 100 (Note ) -10 to 60-0 to 60-10 to 90-0 to 100 (Note ) -10 to 60-0 to 60-10 to 4-0 to 100 (Note ) 0. or less (air) 300 or less (air) Note 1: No freezing Note : The range is -0 to 80 C when using the P terminal box with indicator light for the coil housing. N/G US/G F/G FG/G Flow characteristics Orifice (mm) Flow characteristics Port size C [dm 3 /(s bar)] b Cv flow factor TOP OY TOP OY TOP OY TOP OY G31-01-1 1.5 1.5 0.9 0.9 0.64 0.53 0.09 0.09 Rc1/8-01-.0.0 0.53 0.53 0.54 0.5 0.15 0.15-0-1 1.5 1.5 0.9 0.9 0.64 0.53 0.09 0.09 Rc1/4-0-.0.0 0.53 0.53 0.54 0.5 0.15 0.15 G41-0-1.0.0 0.53 0.53 0.54 0.5 0.15 0.15 Rc1/4-0-.3.3 0.74 0.74 0.66 0.53 0.19 0.19-03-1.0.0 0.53 0.53 0.54 0.5 0.15 0.15 Rc3/8-03-.3.3 0.74 0.74 0.66 0.53 0.19 0.19 *1: ffective sectional area S and sonic conductance C are converted as S 5.0 x C. FV FW/G F FL G P/ PK/ K For dry air xplosion proof V/ VL S/ SV NP/NP/ NVP C/G MX/G Other G.P. systems P/F/ PJ CV/ CVS CP/ CP Medical analysis Custom order General purpose valve irect acting 3 port solenoid valve 167
G3141 Series ow to order G31 G41 0 3 G S C100V Port size Orifice C ody/sealant combination *1 * *3 *4 Coil housing G Other options Manual override (locking) Surge suppressor F Mounting plate I Voltage Symbol escriptions Port size 01 Rc1/8 0 Rc1/4 03 Rc3/8 Orifice 1 ø1.5 ø.0 Symbol 1G G 3G ø1.5 ø.0 escriptions G 1/8 G 1/4 G 3/8 Symbol 1N N 3N ø.0 ø.3 escriptions 1/8NPT 1/4NPT 3/8NPT G31 G41 TOP OY TOP OY ø.0 ø.3 C ody/sealant combination ody Sealant Treatment Remarks lank Nitrile rubber ir, water, low vacuum, kerosene (up to 60 C) Fluoro rubber ir, low vacuum, kerosene (up to 90 C *) C PTF Steam (up to 4 C *) V Fluoro rubber Vacuum inspection Medium vacuum Nitrile rubber ir, water, low vacuum, kerosene (up to 60 C) Fluoro rubber ir, low vacuum, kerosene (up to 90 C *) F PTF Steam (up to 4 C *) W Fluoro rubber Vacuum inspection Medium vacuum Nitrile rubber ir, water, low vacuum, kerosene (up to 60 C) J Fluoro rubber ir, low vacuum, kerosene (up to 90 C *) K PTF Steam (up to 4 C *) P thylene propylene diene rubber ot water (up to 90 C *) L Nitrile rubber Oil free ir, water, low vacuum, kerosene (up to 60 C) M Fluoro rubber ir, low vacuum, kerosene (up to 90 C *) N PTF Steam (up to 4 C *) R thylene propylene diene rubber ot water (up to 90 C *) Std. Option rass Stainless steel Stainless steel rass G31 G41 Refer to page 36 in the Introduction for details on the material combinations. <xample 1 of model number> G31-0-1-C100V : G31 168 to I Refer to the following page for details on the coil housing, other options and voltage, etc. Port size: Rc1/4 The combinations indicated with in the above table are available. Orifice: TOP - ø1.5, OY - ø1.5 C ody/sealant combination: ody - bronze, sealant - nitrile rubber Coil housing: Grommet lead wire to : lank I Voltage: 100 VC 50/60z, 110 VC 60z <xample of model number> G41-03--000S-C100V : G41 Port size: Rc3/8 Orifice: TOP - ø.3, OY - ø.3 C ody/sealant combination: ody - bronze, sealant - nitrile rubber Coil housing: Grommet lead wire Manual override (locking): Selected F Mounting plate: Selected G Other options: lank Surge suppressor: Selected I Voltage: 100 VC 50/60z, 110 VC 60z Note on C *1: *: *3: *4: Note on model no. selection Leave blank for standard. owever, to select options in to, indicate 0 for C. When 4, 4M or 4N is selected for C. The ethylene propylene diene rubber seal combination (C P/R) cannot be used with air. (Compressed air contains oil, and ethylene propylene diene rubber is not oil-resistant.) For option symbols V and W, vacuum is inspected at "leakage amount: 1.33 x 10-6 Pa m 3 /s or less".
G3141 Series For to I, the combinations indicated with symbols can be manufactured. Note that if options to are not required, no symbol is indicated. Coil housing escriptions lank G 3 3M 3N 3I 3J 4 4M 4N 5 5M 5N 5I 5J lank Std. Option Grommet lead wire IN terminal box IN terminal box (G1/) (Pg11) IN terminal box + small light (Pg11) Lead wire P terminal box (G1/) Open frame type P terminal box + light (G1/) P terminal box (IP65 or equivalent) (G1/) P terminal box + light (IP65 or equivalent) (G1/) Open Lead wire frame type P terminal box (heat proof class ) P terminal box + light Lead wire (G1/) (G1/) Open P terminal box (G1/) frame type P terminal box + light (G1/) (diode integrated) P terminal box (IP65 or equivalent) (G1/) P terminal box + light (IP65 or equivalent) (G1/) Grommet lead wire 300 mm F G Other options Cable gland Conduit (Marine cable gland) (Conduit pipe) Manual override (locking) Mounting plate -15a -15b -15c CTC19 G1/ F F F G G G G Surge suppressor S S S I Rated voltage escriptions 100 VC, 00 VC 100 VC, 00 VC 1 VC, 4 VC, 48 VC, 100 VC 100 VC, 00 VC, 4 VC 100 VC, 00 VC 1 VC, 4 VC, 48 VC, 100 VC 100 VC, 00 VC, 1 VC, 4 VC, 100 VC 100 VC, 00 VC, 1 VC, 4 VC, 48 VC, 100 VC 100 VC, 00 VC, 1 VC, 4 VC, 100 VC 100 VC, 00 VC 100 VC, 00 VC Refer to the following precautions for to I. Conduit G (CTC19) (G1/) N/G US/G F/G FG/G FV FW/G F FL G P/ PK/ K For dry air xplosion proof V/ VL S/ SV NP/NP/ NVP G IN terminal box C/G MX/G 3 4 5 3M 3N 4M 4N 5M 5N 3I 3J 5I 5J Open frame type grommet lead wire 300 mm 4 (heat proof class ) 5 (diode integrated) Open frame P terminal box 4M, 4N (heat proof class ) 5M, 5N (diode integrated) Open frame P terminal box (IP65 or equivalent) 5I, 5J (diode integrated) * Refer to page 1 for coil selection. Note on model no. selection Note on *5: Leave blank for the standard coil housing. owever, to select options in to, indicate 00 for. *6: 5, 5M, 5N, 5I and 5J are coils for which C power is converted to C with a diode. *7: C coil for steam is available for G41. Contact CK for more information. Note on to *8: When C is C, F, K, N, V or W, the manual override ( ) is not available. *9: Select one among,, F, G and for G. *10: The surge suppressor is an accessory for the lead wire coil. When selecting a coil with terminal box, the surge suppressor is mounted in the terminal box. *11: s standard, the surge suppressor is incorporated in the coil with diode and the 4 VC coil ( ), so the surge suppressor symbol S cannot be selected. *1: Tropicalization (rust-proof coating) is available as a measure against rust. Contact CK for more information. Note that the tropicalization is not available when the manual override option is selected. Note on I *13: 100 VC coil is compatible with 100 VC 50/60 z and 110 VC 60 z, and 00 VC coil is compatible with 00 VC 50/60 z and 0 VC 60 z. Note that the coils 5/5M/5N/5I/5J can be used only with 100 VC 50/60 z or 00 VC 50/60 z. *14: For voltages other than above, consult with CK. *15: The lead wire is available in the standard 300 mm length, and 500 mm, 1000 mm, 000 mm and 3000 mm lengths. Contact CK for more information. 169 Other G.P. systems P/F/ PJ CV/ CVS CP/ CP Medical analysis Custom order General purpose valve irect acting 3 port solenoid valve
G3141 Series Internal structure and parts list G31/41 Series NO 1 3 4 COM NC 5 6 7 8 9 No. Parts name Material 1 Socket Coil C3604 (SUS303) rass (stainless steel) 3 4 Core assembly SUS405 or equivalent, 316L, 403 *1 Shading coil Cu (g for stainless steel body) Stainless steel Copper (silver for stainless steel body) 5 Plunger SUS405 or equivalent Stainless steel NR: Nitrile rubber 6 Sealant NR (FKM, PM, PTF) FKM: Fluoro rubber NR (FKM, PM, PTF) PM: thylene propylene diene rubber 7 O ring (S568/019) PTF: Tetrafluoroethylene resin 8 Plunger spring SUS304 Stainless steel 9 ody C3771 (SUS303) rass (stainless steel) *1: When the body/sealant combination symbol is other than blank or, the material is SUS405 or equivalent, 316L, 430. *: ( ) shows option. imensions: G31 Series Grommet lead wire type G31-01/0-1 to 0 7 34 <Reference> s the JIS symbol flow shows, pressure can be applied from any of the three piping ports. Generally, two orifices (TOP, OY) have the same values and rated pressure. When de-energized: COM NO or NO COM When energized: COM NC or NC COM Note 1: The dimensions are the same for the G or NPT thread port size 11 63 94 36 -M5 depth 8 8 Rc1/8 (01) Rc1/4 (0) CK * Lead wire length 300 mm 170
G3141 Series Optional dimensions: G31 Series IN terminal box G31-01/0-1 to -* G C 7.5 * Refer to the grommet lead wire type dimensions on the left page for common dimensions. Open frame type G31-01/0-1 to -* 3 4 5 4 38 38 N/G US/G F/G FG/G 39 (41) 39.5 3.6 94 FV FW/G 50.5 F Voltage C C imensions shown in ( ) are for G1/. C 0 6 50.5 (50) 1 63.5 5 (51.5) FL G Open frame type + P terminal box G31-01/0-1 to -* 3 M 4M 5 N 4N I J 99 68 45 Open frame type + conduit G31-01/0-1 to -* 3 G 4 5 53 (56) CTC19 (G1/) imensions shown in ( ) are for G1/. P/ PK/ K For dry air xplosion proof V/ VL S/ SV NP/NP/ NVP C/G Stainless steel body G31-01/0-1 to - //F/R/W/L/M/N ø37.5 11 63 94 Manual override (locking) G31-01/0-1 to -*** Figure shows the brass body. COM Manual override NC 19.5 36 (ø37.5) 38 imensions shown in ( ) are for stainless steel body. MX/G Other G.P. systems P/F/ PJ CV/ CVS CP/ CP Medical analysis Custom order Mounting plate G31-01/0-1 to -*** 30 6 4-ø5.5 50 -ø6 8 General purpose valve irect acting 3 port solenoid valve 58 Mounting plate No. 1 G-100106 171
G3141 Series imensions: G41 Series Grommet lead wire type G41-0/03-1 to 3.5 30.5 38 <Reference> s the JIS symbol flow shows, pressure can be applied from any of the three piping ports. Generally, two orifices (TOP, OY) have the same values and rated pressure. When de-energized: COM NO or NO COM When energized: COM NC or NC COM Note 1: The dimensions are the same for the G or NPT thread port size. C -M5 depth 8 Rc1/4 (0) Rc3/8 (03) CK * Lead wire length 300 mm G41-0-1 to G41-03-1 to C 36 40 8 11 8 1 68 71 99.5 106 17
G3141 Series Optional dimensions: G41 Series IN terminal box G41-0/03-1 to -* G F G 7.5 * Refer to the grommet lead wire type dimensions on the left page for common dimensions. Open frame lead wire type G41-0/03-1 to -* 3 4 5 8 4 46 N/G US/G F/G 39 (41) 40.5 <44> 38.5 FG/G FV FW/G imensions shown in < > are for Rc3/8. imensions shown in ( ) are for G1/. Voltage F G C C 3.5 3.5 65.5 66 54 (53.5) 54.5 (54) G41-0-1 to -** G41-03-1 to -** 5 55 99.5 106 F FL Open frame type + P terminal box G41-0/03-1 to -* 3 M 4M 5 N 4N I 103 J 7 Open frame type + conduit G41-0/03-1 to -* 3 G 4 5 57 (60) G P/ PK/ K For dry air xplosion proof 45 58 Stainless steel body G41-0/03-1 to 7- //F/R/W/L/M/N imensions shown in ( ) are for G1/. Manual override (locking) G41-0/03-1 to *** Figure shows the brass body. CTC19 (G1/) V/ VL S/ SV NP/NP/ NVP C/G MX/G C C G41-0-1 to -* ø37.5 11 68 99.5 G41-03-1 to -* ø45 1 71 106 COM Manual override NC K K G41-0-1 to -*** 36 (ø37.5) G41-03-1 to -*** 40 (ø45.0) 38 40 19.5.5 imensions shown in ( ) are for stainless steel body. Other G.P. systems P/F/ PJ CV/ CVS CP/ CP Medical analysis Custom order Mounting plate G41-0/03-1 to -*** 30 8 6 (70) 4-ø5.5 50 (58) () -ø6 imensions shown in ( ) are for mounting plate No.. Code Mounting plate No. 1 G-100106 Mounting plate No. G-100159 pplicable model G41-0/03-1 to Series Stainless steel body G41-0-1 to - //F/L/M/N/R/W Stainless steel body G41-03-1 to - //F/L/M/N/R/W General purpose valve irect acting 3 port solenoid valve 173