Discrete direct acting 3 port solenoid valve (general purpose valve) AG31/AG41 Series. Universal type Port size: Rc1/8, Rc1/4, Rc3/8

Similar documents
Discrete direct acting 3 port solenoid valve (general purpose valve) Universal type Port size: Rc1/8, Rc1/4, Rc3/ to to 60 B

Discrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type

Discrete direct acting 3 port solenoid valve (general purpose valve) NC pressurization type. Port size: Rc1/8, Rc1/4, Rc3/8

NO (normally closed) type Common supply type (port C pressurization) MPa MPa MPa C C

General purpose direct acting 2, 3 port solenoid valve

Pilot operated 2 port solenoid valve (general purpose valve) AP11/AP12 Series. Air, water, kerosene, oil (50 mm 2 /s or less) -10 to to 60 B

GENERAL PURPOSE VALVE AB31 AB41 AB42 SERIES Discrete valve. Direct acting poppet structure Port size : Rc1/8, Rc1/4, Rc3/8, Rc1/2.

HVB/HVL. Solenoid valve for high vacuum. For vacuum, inert gas, air, nitrogen CONTENTS. Overview

Pilot kick type 2 port solenoid valve for dry air (general purpose valve) ADK11-Z Series. NC (normally closed) type

HN B G1/US B G2/US B G3

AB41E4-Z Series. Pressure and explosion proof structure d2g4 (flame-proof grade 2, ignitability G4) NC (normally closed) type. Port size: Rc1/4, Rc3/8

Discrete air operated 2 port valve (compact cylinder valve) NC (normally closed) type

MYB1/MYG1 Series DC12V. Metal free 2, 3 port solenoid valve for chemical liquid

4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating,

Pilot operated 2 port valve for dust collector control (pulsejet valve) Common specifications Air operated type. Solenoid valve mounted type Item OUT

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

PD3/PDV3-20A/25A/40A Series

VXP21/22/23 Series. Pilot Operated 2 Port Solenoid Valve. For Air, Gas, Steam, Water and Oil VX2 VXK VXD VXZ VXS VXB VXE VXP VXR VXH VXF VX3 VXA

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Air Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. Port size: 1/4 to 1 JIS symbol Specifications Description

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm

Exclusively for air pressure system and air-hydro circuit control

Series VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA

New Products COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER. Lightweight and large flow rate, low power consumption Improved corrosion resistance!

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated/Zero Pressure Differential Operation

High Pressure Coolant Valve

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Compact / Lightweight 2 Port Solenoid Valve

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

PDVE4 Series PDVE4 20A 3T AC100V. Explosion proof 2 port solenoid valve for dust collector control (explosion proof pulsejet valve)

Series VP3145/3165/3185

3 Port Solenoid Valve Direct Operated Poppet Type

Soft Start-up Valve. AV2000/3000/4000/5000 Series

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

Steam Valve. Series VND. 2 Port Valve for Steam. With indicator (Option) By adopting of PTFE seal, the valve is suited for steam.

VNA VNB SGC SGH VNC VNH VND VCC

2/3 Port Valve. Fluid Control. Solenoid Valve/Air Operated Valve For Water, Air, Oil, Gas, Vacuum and Steam

Series VQ Port Solenoid Valve

0.35 W (Without light)

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

2/3 Port Valve for Various Fluids Control

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

3 Port Solenoid Valve

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

CVE2/CVSE2 CVE3/CVSE3

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

3 Port Solenoid Valve

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

Direct Operated 3 Port Solenoid Valve

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Air Operated Valve

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Pilot Operated 2 Port Solenoid Valve for Dry Air

Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air

Series VXR21/22/23. Water Hammer Relief, Pilot Operated 2 Port Solenoid Valve. For Water and Oil

Series VP3145/3165/3185

Symbol. Single DS 2120 R2 P R1. How To Order. Body Type 2 : Body Ported Type. Body Option O : Standard

Compact Proportional Solenoid Valve

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

3, 5 port pilot operated valve Pneumatic valve / master valve. Discrete valve. Manifold

Compressed air to

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

Catalog 080-/USA Notes Vacuum Control Valves

IP65. Compact Direct Operated 2 Port Solenoid Valve. VDW Series. Aluminum Resin(PPS) g. Brass Stainless Steel. 15 mm mm

Design and selection. Installation and adjustment

Series SV1000/2000/3000/4000

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Coolant Valve. VNC Series. Cylinder actuation by pilot air

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Vacuum / Release Unit

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump

Pilot Operated 2 Port Solenoid Valve

Series SY3000/5000/7000

Process Valve/Series VN

1 1/4 (32A) to 2 (50A) added.

4 Port Solenoid Valve

Series VQZ1000/2000/3000 Single Unit

3 Port Solenoid Valve

MICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

3 million cycles. High Pressure Coolant Valve. SGH Series W (24 VDC) (With light/surge voltage suppressor: 0.58 W)

4 Port Solenoid Valve

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

Transcription:

G3141 Series iscrete direct acting 3 port solenoid valve (general purpose valve) G31/G41 Series Universal type Port size: Rc1/8, Rc1/4, Rc3/8 JIS symbol G31/41: Universal type COM NO NC Common specifications Item Standard specifications Optional specifications Working fluid irflow, low vacuum (1.33 x 10 Pa (abs)), water, kerosene, oil (50 mm /s or less) ot water Steam Working pressure differential range MPa Max. working pressure MPa Withstanding pressure (water) MPa 0 to 1 (refer to max. working pressure differential in individual specifications.) 1 5 Fluid temperature (Note 1) C -10 to 60-10 to 90-10 to 4 mbient temperature eat proof class C -0 to 60-0 to 100 tmosphere Valve structure Place free of corrosive gas and explosive gas irect acting poppet structure Valve seat leakage cm 3 /min. (NR) 0. or less (air) 300 or less (air) Mounting attitude ody, sealant rass, nitrile rubber Free rass, ethylene propylene diene rubber rass, PTF Note 1: No freezing Individual specifications Item G31-01-1-01- -0-1 -0- G41-0-1-0- -03-1 -03- Port size Rc1/8 Rc1/4 Rc1/4 Rc3/8 Orifice (mm) TOP OY 1.5 1.5.0.0 1.5 1.5.0.0.0.0.3.3.0.0.3.3 Max. working pressure differential (MPa) ir Water, hot water, kerosene Oil (50 mm /s) Steam C C C C C C C 0.7 0.7 0.7 0.7 0.6 0.6 (0.5) 0.7 0. (0.35) 0.5 (0.15) 0.7 0.7 0.7 0.7 0.6 0.6 (0.5) 0.7 0. (0.35) 0.5 (0.15) 0.7 0.3 1.0 (5) 1.0 0.7 (0.5) 0.15 0.7 (0.5) 0.7 0.5 (0.1) 0.7 0.3 1.0 (5) 1.0 0.7 (0.5) 1.0 0.7 1.0 0.7 (0.5) 0.7 0.5 0.15 (0.1) 0.7 Rated voltage 100 VC 50/60 z 110 VC 60 z 00 VC 50/60 z 0 VC 60 z 1 VC 4 VC 48 VC 100 VC pparent power (V) Power consumption (W) olding Starting C C Weight (kg) 50 z 60 z 50 z 60 z 50/60 z 14 11 0 16 6/4. 11 (8.1) 0.36 5 11 17 35 7 8.3/6. (1) 8 *1: The model numbers above show the basic port size (Rc) and orifice diameter. Refer to ow to order for other combinations. *: Refer to C column for the max. working pressure differential of coil with diode. *3: The voltage fluctuation must be within ±10% of the rated voltage. *4: Values in ( ) are for the type with IN terminal box and C voltage specifications, and indicate the max. working pressure differential when pressurizing from the NO port. *5: When continuously energizing the valve, use a fluoro rubber seal. *6: When the sealant is PTF, the NO port cannot be pressurized. 166

G3141 Series Optional specifications (fluid temperature, ambient temperature, valve seat leakage) Sealant Coil (heat proof class) Fluid temperature (Note 1) C mbient temperature C Valve seat leakage cm 3 /min. (NR) Fluoro rubber thylene propylene diene rubber PTF -10 to 60-0 to 60-10 to 90-0 to 100 (Note ) -10 to 60-0 to 60-10 to 90-0 to 100 (Note ) -10 to 60-0 to 60-10 to 4-0 to 100 (Note ) 0. or less (air) 300 or less (air) Note 1: No freezing Note : The range is -0 to 80 C when using the P terminal box with indicator light for the coil housing. N/G US/G F/G FG/G Flow characteristics Orifice (mm) Flow characteristics Port size C [dm 3 /(s bar)] b Cv flow factor TOP OY TOP OY TOP OY TOP OY G31-01-1 1.5 1.5 0.9 0.9 0.64 0.53 0.09 0.09 Rc1/8-01-.0.0 0.53 0.53 0.54 0.5 0.15 0.15-0-1 1.5 1.5 0.9 0.9 0.64 0.53 0.09 0.09 Rc1/4-0-.0.0 0.53 0.53 0.54 0.5 0.15 0.15 G41-0-1.0.0 0.53 0.53 0.54 0.5 0.15 0.15 Rc1/4-0-.3.3 0.74 0.74 0.66 0.53 0.19 0.19-03-1.0.0 0.53 0.53 0.54 0.5 0.15 0.15 Rc3/8-03-.3.3 0.74 0.74 0.66 0.53 0.19 0.19 *1: ffective sectional area S and sonic conductance C are converted as S 5.0 x C. FV FW/G F FL G P/ PK/ K For dry air xplosion proof V/ VL S/ SV NP/NP/ NVP C/G MX/G Other G.P. systems P/F/ PJ CV/ CVS CP/ CP Medical analysis Custom order General purpose valve irect acting 3 port solenoid valve 167

G3141 Series ow to order G31 G41 0 3 G S C100V Port size Orifice C ody/sealant combination *1 * *3 *4 Coil housing G Other options Manual override (locking) Surge suppressor F Mounting plate I Voltage Symbol escriptions Port size 01 Rc1/8 0 Rc1/4 03 Rc3/8 Orifice 1 ø1.5 ø.0 Symbol 1G G 3G ø1.5 ø.0 escriptions G 1/8 G 1/4 G 3/8 Symbol 1N N 3N ø.0 ø.3 escriptions 1/8NPT 1/4NPT 3/8NPT G31 G41 TOP OY TOP OY ø.0 ø.3 C ody/sealant combination ody Sealant Treatment Remarks lank Nitrile rubber ir, water, low vacuum, kerosene (up to 60 C) Fluoro rubber ir, low vacuum, kerosene (up to 90 C *) C PTF Steam (up to 4 C *) V Fluoro rubber Vacuum inspection Medium vacuum Nitrile rubber ir, water, low vacuum, kerosene (up to 60 C) Fluoro rubber ir, low vacuum, kerosene (up to 90 C *) F PTF Steam (up to 4 C *) W Fluoro rubber Vacuum inspection Medium vacuum Nitrile rubber ir, water, low vacuum, kerosene (up to 60 C) J Fluoro rubber ir, low vacuum, kerosene (up to 90 C *) K PTF Steam (up to 4 C *) P thylene propylene diene rubber ot water (up to 90 C *) L Nitrile rubber Oil free ir, water, low vacuum, kerosene (up to 60 C) M Fluoro rubber ir, low vacuum, kerosene (up to 90 C *) N PTF Steam (up to 4 C *) R thylene propylene diene rubber ot water (up to 90 C *) Std. Option rass Stainless steel Stainless steel rass G31 G41 Refer to page 36 in the Introduction for details on the material combinations. <xample 1 of model number> G31-0-1-C100V : G31 168 to I Refer to the following page for details on the coil housing, other options and voltage, etc. Port size: Rc1/4 The combinations indicated with in the above table are available. Orifice: TOP - ø1.5, OY - ø1.5 C ody/sealant combination: ody - bronze, sealant - nitrile rubber Coil housing: Grommet lead wire to : lank I Voltage: 100 VC 50/60z, 110 VC 60z <xample of model number> G41-03--000S-C100V : G41 Port size: Rc3/8 Orifice: TOP - ø.3, OY - ø.3 C ody/sealant combination: ody - bronze, sealant - nitrile rubber Coil housing: Grommet lead wire Manual override (locking): Selected F Mounting plate: Selected G Other options: lank Surge suppressor: Selected I Voltage: 100 VC 50/60z, 110 VC 60z Note on C *1: *: *3: *4: Note on model no. selection Leave blank for standard. owever, to select options in to, indicate 0 for C. When 4, 4M or 4N is selected for C. The ethylene propylene diene rubber seal combination (C P/R) cannot be used with air. (Compressed air contains oil, and ethylene propylene diene rubber is not oil-resistant.) For option symbols V and W, vacuum is inspected at "leakage amount: 1.33 x 10-6 Pa m 3 /s or less".

G3141 Series For to I, the combinations indicated with symbols can be manufactured. Note that if options to are not required, no symbol is indicated. Coil housing escriptions lank G 3 3M 3N 3I 3J 4 4M 4N 5 5M 5N 5I 5J lank Std. Option Grommet lead wire IN terminal box IN terminal box (G1/) (Pg11) IN terminal box + small light (Pg11) Lead wire P terminal box (G1/) Open frame type P terminal box + light (G1/) P terminal box (IP65 or equivalent) (G1/) P terminal box + light (IP65 or equivalent) (G1/) Open Lead wire frame type P terminal box (heat proof class ) P terminal box + light Lead wire (G1/) (G1/) Open P terminal box (G1/) frame type P terminal box + light (G1/) (diode integrated) P terminal box (IP65 or equivalent) (G1/) P terminal box + light (IP65 or equivalent) (G1/) Grommet lead wire 300 mm F G Other options Cable gland Conduit (Marine cable gland) (Conduit pipe) Manual override (locking) Mounting plate -15a -15b -15c CTC19 G1/ F F F G G G G Surge suppressor S S S I Rated voltage escriptions 100 VC, 00 VC 100 VC, 00 VC 1 VC, 4 VC, 48 VC, 100 VC 100 VC, 00 VC, 4 VC 100 VC, 00 VC 1 VC, 4 VC, 48 VC, 100 VC 100 VC, 00 VC, 1 VC, 4 VC, 100 VC 100 VC, 00 VC, 1 VC, 4 VC, 48 VC, 100 VC 100 VC, 00 VC, 1 VC, 4 VC, 100 VC 100 VC, 00 VC 100 VC, 00 VC Refer to the following precautions for to I. Conduit G (CTC19) (G1/) N/G US/G F/G FG/G FV FW/G F FL G P/ PK/ K For dry air xplosion proof V/ VL S/ SV NP/NP/ NVP G IN terminal box C/G MX/G 3 4 5 3M 3N 4M 4N 5M 5N 3I 3J 5I 5J Open frame type grommet lead wire 300 mm 4 (heat proof class ) 5 (diode integrated) Open frame P terminal box 4M, 4N (heat proof class ) 5M, 5N (diode integrated) Open frame P terminal box (IP65 or equivalent) 5I, 5J (diode integrated) * Refer to page 1 for coil selection. Note on model no. selection Note on *5: Leave blank for the standard coil housing. owever, to select options in to, indicate 00 for. *6: 5, 5M, 5N, 5I and 5J are coils for which C power is converted to C with a diode. *7: C coil for steam is available for G41. Contact CK for more information. Note on to *8: When C is C, F, K, N, V or W, the manual override ( ) is not available. *9: Select one among,, F, G and for G. *10: The surge suppressor is an accessory for the lead wire coil. When selecting a coil with terminal box, the surge suppressor is mounted in the terminal box. *11: s standard, the surge suppressor is incorporated in the coil with diode and the 4 VC coil ( ), so the surge suppressor symbol S cannot be selected. *1: Tropicalization (rust-proof coating) is available as a measure against rust. Contact CK for more information. Note that the tropicalization is not available when the manual override option is selected. Note on I *13: 100 VC coil is compatible with 100 VC 50/60 z and 110 VC 60 z, and 00 VC coil is compatible with 00 VC 50/60 z and 0 VC 60 z. Note that the coils 5/5M/5N/5I/5J can be used only with 100 VC 50/60 z or 00 VC 50/60 z. *14: For voltages other than above, consult with CK. *15: The lead wire is available in the standard 300 mm length, and 500 mm, 1000 mm, 000 mm and 3000 mm lengths. Contact CK for more information. 169 Other G.P. systems P/F/ PJ CV/ CVS CP/ CP Medical analysis Custom order General purpose valve irect acting 3 port solenoid valve

G3141 Series Internal structure and parts list G31/41 Series NO 1 3 4 COM NC 5 6 7 8 9 No. Parts name Material 1 Socket Coil C3604 (SUS303) rass (stainless steel) 3 4 Core assembly SUS405 or equivalent, 316L, 403 *1 Shading coil Cu (g for stainless steel body) Stainless steel Copper (silver for stainless steel body) 5 Plunger SUS405 or equivalent Stainless steel NR: Nitrile rubber 6 Sealant NR (FKM, PM, PTF) FKM: Fluoro rubber NR (FKM, PM, PTF) PM: thylene propylene diene rubber 7 O ring (S568/019) PTF: Tetrafluoroethylene resin 8 Plunger spring SUS304 Stainless steel 9 ody C3771 (SUS303) rass (stainless steel) *1: When the body/sealant combination symbol is other than blank or, the material is SUS405 or equivalent, 316L, 430. *: ( ) shows option. imensions: G31 Series Grommet lead wire type G31-01/0-1 to 0 7 34 <Reference> s the JIS symbol flow shows, pressure can be applied from any of the three piping ports. Generally, two orifices (TOP, OY) have the same values and rated pressure. When de-energized: COM NO or NO COM When energized: COM NC or NC COM Note 1: The dimensions are the same for the G or NPT thread port size 11 63 94 36 -M5 depth 8 8 Rc1/8 (01) Rc1/4 (0) CK * Lead wire length 300 mm 170

G3141 Series Optional dimensions: G31 Series IN terminal box G31-01/0-1 to -* G C 7.5 * Refer to the grommet lead wire type dimensions on the left page for common dimensions. Open frame type G31-01/0-1 to -* 3 4 5 4 38 38 N/G US/G F/G FG/G 39 (41) 39.5 3.6 94 FV FW/G 50.5 F Voltage C C imensions shown in ( ) are for G1/. C 0 6 50.5 (50) 1 63.5 5 (51.5) FL G Open frame type + P terminal box G31-01/0-1 to -* 3 M 4M 5 N 4N I J 99 68 45 Open frame type + conduit G31-01/0-1 to -* 3 G 4 5 53 (56) CTC19 (G1/) imensions shown in ( ) are for G1/. P/ PK/ K For dry air xplosion proof V/ VL S/ SV NP/NP/ NVP C/G Stainless steel body G31-01/0-1 to - //F/R/W/L/M/N ø37.5 11 63 94 Manual override (locking) G31-01/0-1 to -*** Figure shows the brass body. COM Manual override NC 19.5 36 (ø37.5) 38 imensions shown in ( ) are for stainless steel body. MX/G Other G.P. systems P/F/ PJ CV/ CVS CP/ CP Medical analysis Custom order Mounting plate G31-01/0-1 to -*** 30 6 4-ø5.5 50 -ø6 8 General purpose valve irect acting 3 port solenoid valve 58 Mounting plate No. 1 G-100106 171

G3141 Series imensions: G41 Series Grommet lead wire type G41-0/03-1 to 3.5 30.5 38 <Reference> s the JIS symbol flow shows, pressure can be applied from any of the three piping ports. Generally, two orifices (TOP, OY) have the same values and rated pressure. When de-energized: COM NO or NO COM When energized: COM NC or NC COM Note 1: The dimensions are the same for the G or NPT thread port size. C -M5 depth 8 Rc1/4 (0) Rc3/8 (03) CK * Lead wire length 300 mm G41-0-1 to G41-03-1 to C 36 40 8 11 8 1 68 71 99.5 106 17

G3141 Series Optional dimensions: G41 Series IN terminal box G41-0/03-1 to -* G F G 7.5 * Refer to the grommet lead wire type dimensions on the left page for common dimensions. Open frame lead wire type G41-0/03-1 to -* 3 4 5 8 4 46 N/G US/G F/G 39 (41) 40.5 <44> 38.5 FG/G FV FW/G imensions shown in < > are for Rc3/8. imensions shown in ( ) are for G1/. Voltage F G C C 3.5 3.5 65.5 66 54 (53.5) 54.5 (54) G41-0-1 to -** G41-03-1 to -** 5 55 99.5 106 F FL Open frame type + P terminal box G41-0/03-1 to -* 3 M 4M 5 N 4N I 103 J 7 Open frame type + conduit G41-0/03-1 to -* 3 G 4 5 57 (60) G P/ PK/ K For dry air xplosion proof 45 58 Stainless steel body G41-0/03-1 to 7- //F/R/W/L/M/N imensions shown in ( ) are for G1/. Manual override (locking) G41-0/03-1 to *** Figure shows the brass body. CTC19 (G1/) V/ VL S/ SV NP/NP/ NVP C/G MX/G C C G41-0-1 to -* ø37.5 11 68 99.5 G41-03-1 to -* ø45 1 71 106 COM Manual override NC K K G41-0-1 to -*** 36 (ø37.5) G41-03-1 to -*** 40 (ø45.0) 38 40 19.5.5 imensions shown in ( ) are for stainless steel body. Other G.P. systems P/F/ PJ CV/ CVS CP/ CP Medical analysis Custom order Mounting plate G41-0/03-1 to -*** 30 8 6 (70) 4-ø5.5 50 (58) () -ø6 imensions shown in ( ) are for mounting plate No.. Code Mounting plate No. 1 G-100106 Mounting plate No. G-100159 pplicable model G41-0/03-1 to Series Stainless steel body G41-0-1 to - //F/L/M/N/R/W Stainless steel body G41-03-1 to - //F/L/M/N/R/W General purpose valve irect acting 3 port solenoid valve 173