References. Infrared Array Sensor Grid-EYE Unit Type AMGU Part Name : Infrared Array Sensor Grid-EYE Unit Type. 2. Part No.

Similar documents
Analog Output Terminal

Analog Input Terminal

Series 905-IV16(E) CAN/CANopen Input Modules Installation and Operating Manual

ZT-USB Series User Manual

ALM-Inline. Accurate Lambda Meter V1.1.2 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED.

X11CA-IM MASTER MODULE

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW

Barrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind)

Stepping Motor and Driver Package. High-Efficiency AR Series. DC Power-Supply Input. Built-in Controller Type Pulse Input Type

UNIT 8 OTHER SENSORS

Safety Precautions Product Contents Product PIN Diagram LED indicators Product Dimensions Installation of Panel with Casing Wire Legend Power Wiring

PCT200 Powercast High-Function RFID Sensor Datalogger

3. Packages 3.1 Characteristics Model number S4 (Package) Sensing element type Target gas VH Heater Voltage Electrical characteristics PH Powe

AIR VOLUME TRANSMITTER / CONTROLLER IML

LT2 Sport Lambda Measurement Device. Quick Start Manual

EV Display V4 User Guide

SRT1000 Series THERMAL FLOWMETER

MagFlux Q 8200 Series

Speed Dome 66 Installation Manual

USERS MANUAL MCD REMOTE OPERATOR

1 EASY COMMISSIONING GUIDE FRONIUS PV-SYSTEM CONTROLLER

F485 Communications Converter

Ventilation in balance

D R C- 4 0 s e r i e s

Model TUR-200D Turbine Flowmeter

Harris IRT Enterprises Digital Resistance Tester Model XP

Technical Specifications

Features and Benefits. Certifications

KAM OID OPTICAL INTERFACE DETECTOR PTB 08 ATEX User Manual OIDMANUAL An ISO 9001 certified company

Encoder WDGA 58V CAN SAE J1939

Turbidity and Suspended Solids Transmitter

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

INTECH Micro 2300-RTD6

HX-P420 SERIES 4 to 20 ma OUTPUT

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18

2100 Turbine Flow Sensor

OMC-116 Installation manual

Sabertooth 2x50 User s Guide

Communications. Auxiliary. Functions. output. functions. Transistor. Heating or cooling control is selectable (See note 2.

OVERVIEW OF CONTROLS

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

Version 2016 / 07 Stator All-In-One

Interactive Whiteboard. User Guide. Before operating the unit, please read this manual thoroughly, and retain it for future reference

SMART MAGNET BOARD USER MANUAL E0 SMAG 000B

Growatt PV Inverter Modbus RS485 RTU Protocol

The wide variety of systems for controlling and adjusting light brings great advantages:

PowerCommand. ModLon II Gateway. Specifications. ModBus LON Converter

RS485 MODBUS Card. User Manual. Before you start to install this card, please read this User Manual carefully

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

TOWA SEIDEN INDUSTRIAL CO., LTD.

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

User Guide. Panel Mount Digital Tachometer. Model Washington Street Melrose, MA Phone Toll Free

PSK203/PSK223/PSK233. Digital Thermostats for Low Temperature Refrigerating Units 1 GETTING STARTED PSK203 PSK223 PSK233

BG45 BG65S BG75 Axial Parallel Axial Parallel Axial Parallel CASM-32 (LS/BS/BN) X X CASM-40 (LS/BS/BN) X X X X CASM-63 (LS/BN/BF) X X

GTFM V. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5026 Revised: 09/11/2013

Operation angle Return angle Output rating Operating voltage Model 40 to to VDC 2.4 to 3.6 VDC D6BN-1P

RS232. CAN. Integration with Tachograph Continental VDO DTCO

Intercomp. PT300 Users Manual. Manual #: E

Pressure Relief Device Comem PRD Order sheet

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation

Automated Precision Weighing

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

Drive Electronics \ Drive Automation \ System integration \ Services MOVITRAC LTP. Catalog. Edition 03/ / EN

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

No-load power 50mW or less (17mW TYP) Rated input voltage. Ripple noise 300mVp-p or less Rated output current

English. Instruction and operation manual S 430. Pitot tube flow sensor

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

Manual Balanza dosificadora PCE-ABZ 200C

Operations Manual R3. Model C1 V2.0 Electric Chemical Injection System MCI Solutions. All rights reserved

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

MUCM Modbus CCM. Installation and Programming Manual

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Clamp-Type Ultrasonic Flow Meter. Specifications. Archive Date Author. Rev / 07 / 30 M.Shiraishi Rev / 11 / 5 M.

Maximum input voltage 420V or less Including peak value

Pendulum control & isolation valve with RS485 interface with valve cluster functionality

Installation Manual. ACL3200 Flare Stack / Incinerator Ignition Systems

Liquid Turbine Flow Meter OwnerÊs Manual

Rotel RSP-1570 RS232 HEX Protocol

Density Solution. TDF Series. Direct Insertion Density Meter. Characteristics

Precision-I Laboratory System Universal Digital Monitor

UltraGauge MX V1.3. UltraGauge MX 1.3, April 9,

Power System Measurements. Made in U.S.A. Power SeriesP lus. Digital Switchboard Meters.

MATRIX LLC LEVEL CONTROL PANEL

Power Switching Devices

Rotel RSX-1065 RS232 HEX Protocol

SP4 DOCUMENTATION. 1. SP4 Reference manual SP4 console.

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

PMF4000 Series DESCRIPTION FEATURES APPLICATIONS MAXIMUM RATINGS MASS AIR FLOW SENSOR

better measurement Simply a question of

MME/MOE Intelligent Electric Actuators About Ontrac

Silver Series Thermal Dispersion Airflow Measurement Technology

English. Instruction and Operation Manual S 430. Pitot Tube Flow Sensor

Photovoltaics. MPI Hybrid Series

Transcription:

Infrared Array Sensor Grid-EYE Unit Type AMGU44 9-. : Infrared Array Sensor Grid-EYE Unit Type. : AMGU44. Characteristics - Ratings Item unit Specification Min. Typ. Max. Remarks Power supply voltage VDC.6 4 6.4 - Current Consumption ma - 5 5 - Contact capacity - - - DC4V.A Photo MOS Relay Person detectable surrounding temperature (spec. guaranteed temp.) Operating temperature (at power-on) Storage temperature (at power-off) degc + to +9 no condensation degc to +5 no freezing and condensation degc - to +7 no freezing and condensation

Infrared Array Sensor Grid-EYE Unit Type AMGU44 9- - Basic specifications Item Unit Specification Min. Typ. Max. Remarks Installation height m.7 *4 Detection range m.6x.6 At.6m distance from ceiling Moving velocity of target m/s.7 * *4 Location accuracy Target heat source: 4mmx4mm heater (Difference temp.: 4degC) Target heat Source: Human mm +/- - *4 mm +/-5 - *4 Area resolution - Division into 6(4x4) - Indicator light - Red (when detected human) - *4 Address setting range - to 6 sets up by DIPSW Wiring length(max) m 5 * *4 Applicable electric wire - Power, Contact output line : ϕ.65 to.9 RS485 communication line : ϕ.65 to.9 (CPEV) * External Dimensions mm ϕx6.5 - Weight g About 9 Installation hole size mm ϕ +5/- - Ceiling thickness mm - *. The sensor would not be able to detect human who walks faster than.7m/s. *. Shall be tested/evaluated the performance of customer s system which incorporates Grid- EYE unit, and also checked the specification of the controller device to be connected. *. Shall be used CPEV cable with shield for RS485 communication line. *4. Condition: detective temperature range to 9 degc

Infrared Array Sensor Grid-EYE Unit Type AMGU44 9- Detection range (image) Coordinates (image) ceiling X.6m.7m Y floor Indicator light.6m square - Communication specification item unit specification electric specifications - Follow RS-485 Protocol - MODBUS (RTU) Baud rate bps 84 Data length Bit 8 Start bit Bit Stop bit Bit Parity check Bit Parity - Odd Flow control - none -Grid-EYE unit works as a Slave. (Controller: Master) -Shall be checked communication with the controller device to be connected.

Infrared Array Sensor Grid-EYE Unit Type AMGU44 9-4 -4 Communication format -4- Master (controller) to Slave (Grid-EYE unit) The master can request all the data to the sensor using this format. Slave Address byte -4- Slave (Grid-EYE unit) to Master (controller) Slave Address Function Data Address code (starting address) x Hi Lo No. of Registers CRC check byte byte byte byte Function code x Byte Count Hi Data Hi Lo Lo CRC check byte byte byte byte byte byte Hi Data Lo -4- Data address and corresponded data data address contents kind of data data range: hexadecimal Number of person Unsigned 6bits H to 8H Human coordinates Unsigned bits H to FFFFFFFFH Exist/absence data Unsigned 6bits H to FFFFH 4 5 Moving directions Unsigned bits H to FFFFFFFFH 6 Temperature data Signed 6bits H to FFFFH -5 Contents of communication data Grid-EYE unit sends the data of below )-5) requested by Master (controller). ) Number of person; to 8 "x" & "xf" are sent until human detection operation starts after power-on. 7 6 5 4 n n n n bytes

Infrared Array Sensor Grid-EYE Unit Type AMGU44 9-5 ) human's coordinates (8 persons) Grid-EYE unit outputs human's detected position with XY coordinates, and sequenti ally outputs the coordinates for the detected number of person in clause ) from (Xad, Yad) in order. Undetected data position is set to (, ). Data (, ) to be determined/judged at system side whether undetected data (, ) or detected data of coordinates (, ), based on the data for detected number of p erson in clause ); 7 6 5 4 Yad [:] Xad [:] Yad [:] Xad [:] Yad4 [:] Yad6 [:] Xad4 [:] Xad6 [:] Yad [:] Yad5 [:] Xad [:] Xad5 [:] 4bytes Yad8 [:] Xad8 [:] Yad7 [:] Xad7 [:] X Y ) exist/absence data Grid-EYE unit outputs the person exist/absence data in the divided 6 area. : absence, : exist 7 6 5 4 d8 d6 d7 d5 d6 d4 d5 d d4 d d d d d d d9 bytes X Y d d d d4 d5 d6 d7 d8 d9 d d d d d4 d5 d6

Infrared Array Sensor Grid-EYE Unit Type AMGU44 9-6 4) Moving direction Grid-EYE outputs person moving direction with total 9 codes, 8 directions surr ounding current position and staying current position. 7 6 5 4 Yvc [:] Xvc [:] Yvc [:] Xvc [:] Yvc4 [:] Yvc6 [:] Xvc4 [:] Xvc6 [:] Yvc [:] Yvc5 [:] Xvc [:] Xvc5 [:] 4bytes Yvc8 [:] Xvc8 [:] Yvc7 [:] Xvc7 [:] Y d5 d4 d6 d7 d8 d d d d9 Current position Moving direction: (Xvc,Yvc) *decimal number d (, ) d (, ) d (-, ) d4 (-, ) d5 (-,- ) d6 (,- ) d7 (,- ) d8 (, ) d9 (, ) *signed binary number d (, ) d (, ) d (, ) d4 (, ) d5 (, ) d6 (, ) d7 (, ) d8 (, ) d9 (, ) When the data undetected of Moving direction: *decimal number ( -, - ) *signed binary number (, ) 5) Temperature data Average data of whole detection area to be outputted. Measurement temperature range: to 5 degc *two s complement data in case of temperature below zero. (Not guaranteed data due to out of temp. spec. range) 7 6 5 4 +/- 6 5 4 bytes - - - -4-5 -6-7 -8

Infrared Array Sensor Grid-EYE Unit Type AMGU44 9-7 -6 Wiring diagram Grid-EYE Unit Type 4VDC GND RS485+ RS485- contact output contact output Power Contoroller -6- Terminal Arrangement DC4V GND DC4V GND power power contact output RS485 ( 入力 ) ( 送り ) -6- Wiring to RS485 communication line ( 入力 ) -Be sure to use a twisted-pair cable with a shield. -Be sure to ground a shield one side. + - + - E E RS485 ( 送り ) Be sure to be exclusive D-class grounding with ground resistance of ohm or less. -Be sure to make wiring into cascade connection. (Don't make wiring into star connection.) termination -Be sure to be short-circuit between the send terminal(+,-) and the termination terminal(e,e) of a sensor connected to the end of the wiring. Input Send Termination Input Send Termination + - + - E E + - + - E E RS485-6- Address setup grounding To be set up in 6-bit DIPSW ( to 6). grounding Short-circuit with an electric wire in the case of a termination 5 6 Hi Low Example)address: 5 6 Example)address:8 5 6

Infrared Array Sensor Grid-EYE Unit Type AMGU44 9-8 -6-4 Area mask setup The mask of the detection area can be set by 4-bit DIPSW. (Shading area can not be detected) setteing Mask area setteing Mask area setteing Mask area

Infrared Array Sensor Grid-EYE Unit Type AMGU44 9-9 4. Figure Indicator light (turn red light on when detected human) cover furniture Common Dimension (mm) Difference (mm) Under +/-.6 to 5 +/-. 5 to +/-.6 Over +/-. Unit: mm

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Panasonic: AMGU44