FUEL PENETRATION COMPARED TO WATER PENETRATION INTO CONCRETE VERGLEICH DES EINDRINGVERHALTENS VON WASSER UND KRAFTSTOFFEN IN BETON

Similar documents
VDZ-Service portfolio Concrete and mortar

Assessment of the Effect of Specimens Dimensions on the Measured Transmissivity of Planar Tubular Drainage Geocomposites

Cristallo Extra. STRUCTURE Flexible PVC hose without reinforcement. WORKING TEMPERATURE From -20 C to +60 C

VWR FOR SIEVING. Test sieve shakers and accessories. Ultrasonic sieving systems. Sample splitters. Test sieves. Standards.

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill

SOUTH AFRICAN NATIONAL STANDARD

Nationellt förord. I avvaktan på fastställelse av EN 1008, vatten för betongtillverkning, gäller vad som anges i BBK 94, avsnitt

STRUKTUR Flexibler PVC-Schlauch mit Textilverstärkung. TEMPERATURBESTÄNDIGKEIT Von -20 C bis +60 C. Bursting Pressure bar *

mass flow: 9 kg/min; number of nozzles: 3; nozzle diameter: parameters 10 mm; nozzle distance: 150 mm; shots: StD-G3 (0,6) 700HV

TM BONOWI PROTECTIVE EQUIPMENT

English version. Bituminous mixtures - Test methods for hot mix asphalt - Part 34: Marshall test

Process Control of the Rheology of Self-Compacting Concrete Based on Cusum Control Charts

STUDY OF THE INFLUENCE OF THE TYPE OF FUEL USED IN INTERNAL COMBUSTION ENGINES OVER THE RHEOLOGICAL PROPERTIES OF LUBRICANTS

TECHNICAL SPECIFICATIONS

Guideline No.M-10(201510) M-10 Marine Diesel Engine Fuel Injection Pump

The Design Aspects of Metal- Polymer Bushings in Compressor Applications

Fordringar och provningsmetoder för skyddsskor, Iätta skyddsskor och yrkesskor för arbete

This document is a preview generated by EVS

This document is a preview generated by EVS

Design of Piston Ring Surface Treatment for Reducing Lubricating Oil Consumption

EXPERIMENTAL STUDY ON EFFECTIVENESS OF SHEAR STRENGTHENING OF RC BEAMS WITH CFRP SHEETS

Part 1: Specifications for pipes, fittings and the system English version of DIN EN

THE PRACTICE OF MANUFACTURING DURISOL NOISE BARRIER PANELS

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025: and the Directive 93/42/EEC 2 and 90/385/EEC 3

Effect of road surfaces on road traffic noise on the public roads of Japan. --An investigation based on tyre/road noise measurement--

Geoscience Testing laboratory (Al Ain)

Special edition paper

This document is a preview generated by EVS

DEUTSCHE NORM July 2004 DIN EN ISO 9038 { Test for sustained combustibility of liquids (ISO 9038 : 2002) English version of DIN EN ISO 9038

DEUTSCHE NORM October Structural steel equal and unequal leg angles Part 1: Dimensions English version of DIN EN

Some Information on Eurocode 4 part 1.2

FITTINGS MIT CHEMIESCHUTZSCHICHT FITTINGS WITH CHEMICAL PROTECTION LAYER FITTINGS AVEC BARRIÈRE ANTI- CORROSION ÉPAISSE

SOUTH AFRICAN NATIONAL STANDARD

EFFECT OF INJECTION ORIENTATION ON EXHAUST EMISSIONS IN A DI DIESEL ENGINE: THROUGH CFD SIMULATION

Railway Noise Reduction Technology Using a Damping Material

DEUTSCHE NORM DIN EN 10080

DEUTSCHE NORM October Steels Determination of depth of decarburization (ISO 3887 : 2003) English version of DIN EN ISO 3887

DEUTSCHE NORM February 2005 DIN EN ISO 1514 { Paints and varnishes Standard panels for testing (ISO 1514 : 2004) English version of DIN EN ISO 1514

Chemical indicators and test devices Benchmarking sterilisation processes.

SKU: DR4306. Fixed Orifice Double Regulating Valve

Stability Analysis of 6MW Wind Turbine High Speed Coupling using the Finite Element Method

Chapter 3 Grouting Equipment and Methods

Center for By-Products Utilization

SVENSK STANDARD SS-EN 14263:2004. Derivat från kolpyrolys Tjära och beckbaserade bindemedel och relaterade produkter: Kolbindningsbeck

NORDAC 2014 Topic and no NORDAC

DEUTSCHE NORM DIN Passverzahnungen mit Evolventenflanken und Bezugsdurchmesser Teil 2: Nennmaße und Prüfmaße

INVESTIGATION OF THE FUEL PROPERTY INFLUENCE ON NUMBER OF EMITTED PARTICLES AND THEIR SIZE DISTRIBUTION IN A GASOLINE ENGINE WITH DIRECT INJECTION

Vibration Analysis of Gear Transmission System in Electric Vehicle

OVERSIZED DERAILLEUR PULLEY EFFICIENCY TEST

Gummi- eller plastbelagda tyger - Bestämning av vattentäthet Meted med lågt tryck

COMPUTER AIDED DESIGN OF LOADER WORK ATTACHMENT FOR CONSTRUCTION MACHINES

Additives for Rapeseed Oil Fuel

Kraftfahrt-Bundesamt DE Flensburg

Center for By-Products Utilization

Evidence of performance Reduction of impact sound pressure level by floor coverings

M-11 MARINE DIESEL ENGINE FUEL INJECTOR

TABLES & CONVERSIONS. Linear Conversions. Mass Conversions. Area Conversions. Mass per Area Conversions. Area per Volume Conversions

SOUTH AFRICAN NATIONAL STANDARD

Bituminous mixtures Test methods for hot mix asphalt Part 21: Indentation using plate specimens

Module 2:Genesis and Mechanism of Formation of Engine Emissions Lecture 9:Mechanisms of HC Formation in SI Engines... contd.

Relevance of head injuries in side collisions in Germany Comparison with the analyses and proposals of the WG13

Prediction of Physical Properties and Cetane Number of Diesel Fuels and the Effect of Aromatic Hydrocarbons on These Entities

INFLUENCE OF CROSS FORCES AND BENDING MOMENTS ON REFERENCE TORQUE SENSORS FOR TORQUE WRENCH CALIBRATION

DEFECT DISTRIBUTION IN WELDS OF INCOLOY 908

Effect of Shot Peening Treatment on Forging Die Life

[Rao, 4(7): July, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

High Pressure Spray Characterization of Vegetable Oils

DEUTSCHE NORM March Hexagon head bolts Product grade C (ISO 4016 : 1999) English version of DIN EN ISO 4016

Internal Combustion Engines

Availability Analysis For Optimizing A Vehicle A/C System

MODULAR WATER CHARGE AIR COOLING FOR COMBUSTION ENGINES

Power Arc Testing on Insulator Sets

Järnvägar Spår Provningsmetoder för befästningssystem Del 5: Bestämning av elektriskt motstånd

This document is a preview generated by EVS

WP4.D3 / REPORT ON PROPERTIES AND STANDARD TESTS OF SOLAR FLUIDS FINAL DRAFT

C h e m i c a l a g i n g o f c a t a l y t i c c o n v e r t e r s w i t h r e g a r d t o m e t h a n e c o n v e r s i o n

SVENSK STANDARD SS-EN Vägmaterial Asfaltmassor Provningsmetoder för varmblandad asfalt Del 15: Bestämning av separationskänslighet

DEUTSCHE NORM February 2003

European Regulations for Formaldehyde

Types of Oil and their Properties

Annex to the accreditation certificate D-PL in accordance with DIN EN ISO/IEC 17025:2005

FRm ENGINEERING I:ABORATORY LIBRARY

Performance Characterisation of Catalytic Combustion with Liquid Hydrocarbons based on Temperature Measurements and Emission Analysis

This document is a preview generated by EVS

Continuous Stribeck Curve Measurement Using Pin-on-Disk Tribometer

Test Report No

ScienceDirect A NEW EXPERIMENTAL APPROACH TO TEST OPEN GEARS FOR WINCH DRUMS

This document is a preview generated by EVS

Simulation of Performance Parameters of Spark Ignition Engine for Various Ignition Timings

EME2 Pavement and mix design. Laszlo Petho, Pavements Manager Fulton Hogan.

Modeling the Lithium-Ion Battery

CHEMICAL DISINFECTANTS - QUANTITATIVE SUSPENSION TEST FOR THE EVALUATION OF VIRUCIDAL ACTIVITY AGAINST BACTERIOPHAGES OF

What s going on with European Specifications?

Engine Cycles. T Alrayyes

This document is a preview generated by EVS

Performance of DC Motor Supplied From Single Phase AC-DC Rectifier

Minimum quantity lubrication system MDE for external lubrication. Operation manual

Annex to the accreditation certificate D-PL according to DIN EN ISO/IEC 17025: and council directives 90/385/EWG 2 and 93/42/EWG 3

Plan de présentation CSITC RT

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Transcription:

FUEL PENETRATION COMPARED TO WATER PENETRATION INTO CONCRETE VERGLEICH DES EINDRINGVERHALTENS VON WASSER UND KRAFTSTOFFEN IN BETON COMPARAISON DE LA PÉNÉTRATION D EAU ET CARBURANTS DANS LE BÉTON HansWolf Reinhardt, Arno Pfingstner SUMMARY Two concretes with a watercement ratio of 0.50 and a waterbinder ratio of 0.29 have been tested with respect to the water penetration according to DIN 1048 and ISO 7031 as well as to the absorption of diesel and gasoline according to the german guideline Concrete structures for the handling of water contaminating substances. The test series are described and the results are discussed. ZUSAMMENFASSUNG Zwei Betone mit einem Wasserzementwert von 0,50 und einem Wasserbindemittelwert von 0,29 wurden der Wassereindringprüfung nach DIN 1048 und ISO 7031 unterworfen und auch der Eindringprüfung von Diesel und Ottokraftstoff nach der Richtlinie Betonbau beim Umgang mit wassergefährdenden Stoffen. Die Versuchsserien werden beschrieben und die Ergebnisse werden interpretiert. RESUME Deux bétons avec un rapport eauciment de 0,50 et un rapport eauliant de 0,29 ont été soumis à des essais de pénétration d eau selon les normes DIN 1048 et ISO 7031, ainsi qu à des essais de pénétration de diesel et d essence selon la directive allemande Structures en béton pour le maniement de substances 9 OttoGrafJournal Vol. 9, 1998

H.W. REINHARDT, A. PFINGSTNER contaminantes pour l eau. Les séries d essais sont décrites et les résultats sont discutés. KEYWORDS: Fuel penetration, concrete 1. INTRODUCTION The water penetration test according to DIN 1048 and ISO 7031 are standard tests whereas the penetration test for organic liquids according to [DEUTSCHER AUSSCHUSS FÜR STAHLBETON 1996] is a rather specialised test which requires for special equipment. To check whether the results of both testing methods are similar, tests on two concrete mixtures were performed with water and with diesel and gasoline. 2. TEST METHODS 2.1 Water Tests were performed on plates 200 mm x 200 mm x 120 mm with water penetration in the casting direction. ISO [ISO/DIS 7031, 1963] stipulates a pressure sequence of 0.1 MPa during 2 days, 0.3 MPa another day and 0.7 MPa one more day. DIN [DIN 1048 TEIL 5, 06.91] prescribes a constant pressure of 0.5 MPa for 3 days. A series of specimens was kept under water for 27 days after demoulding and tested. Another series was demoulded after one day, wrapped in plastic sheet during 6 days and stored at 20 C/65% RH during 49 days. 2.2 Diesel and gasoline Diesel and gasoline penetrations were tested according to [DEUTSCHER AUSSCHUSS FÜR STAHLBETON, 1996]. The cylindrical specimen ( 100, h=150 10

Fuel penetration compared to water penetration into concrete mm) were cored from cubes which were demoulded after 1 day, wrapped in plastic sheet during 6 days, and stored at 20 C/65% RH during 49 days. The cylinders were sealed on the perimeter with epoxy resin. A glass funnel was glued on top of the cylinder and connected to a glass tube in order to allow an almost constant fluid head of 500 mm. After this whole procedure the specimen were70dold. 3. CONCRETE A limited series of tests comprised two concretes the composition of which is given in Table 1. Table 1: Composition of two concretes tested, amount/m 3 Component Unit Amount Concrete I Concrete II CEM I 32,5 R CEM I 42,5 R Water 1) Aggregate 0/1 mm 1/2 mm 2/4 mm 4/8 mm 8/16 mm Silica fume 2) Superplasticizer Retarder l l l 320 160 387 221 249 356 690 2,3 465 138 289 238 262 305 625 46,5 24,0 1,5 1) Water of slurry included 2) Dry mass of slurry 11 OttoGrafJournal Vol. 9, 1998

H.W. REINHARDT, A. PFINGSTNER Concrete I is a socalled liquid tight concrete according to [DEUTSCHER AUSSCHUSS FÜR STAHLBETON, 1996], while concrete II is a high performance concrete with watercement ratio of 0.32. The 28 days cube strength measured on 150 mm cubes amounted to 52.1 MPa and 78.9 MPa for concrete I and II. 4. PENETRATION OF LIQUIDS INTO CONCRETE 4.1 Water The tests were performed after 28 and 56 days as mentioned above. The values in Table 2 are maximum values measured on the specimen after splitting. Table 2: Penetration of water in mm Concrete I Concrete II DIN ISO DIN ISO Individual tests after 28 d 15 12 14 13 18 15 14 15 14 14 13 14 15 Mean 13.8 15.3 14.7 13.7 Individual tests after 56 d 23 23 30 23 23 18 27 17 25 16 19 22 Mean 23.8 22.7 20.7 20.5 4.2 Organic liquids 12

Fuel penetration compared to water penetration into concrete Thetwoliquidsdieselandgasoline("Super")areratherdifferentwith respect to their physical properties which govern penetration into a porous medium. The viscosity η of diesel is about five times higher than that of gasoline, while the surface tension σ of both is similar. The relevant parameter (σ/η) 1/2 of diesel is about 0.44 times the one of gasoline, i.e. diesel should penetrate only half as much as gasoline does. Table 3 shows the absorbed volume after 72 h. Table 3: Absorbed volume [l/m 2 ] after 72 h Individual tests 0.56 0.56 0.56 0.50 0.52 Concrete I Concrete II Diesel Gasoline Diesel Gasoline 1.48 1.29 1.41 1.65 0.15 0.22 0.32 0.34 0.32 0.73 0.52 0.80 0.85 0.78 Mean 0.54 1.46 0.27 0.74 The relation between absorbed volume and time is given in Figs. 1 and 2. 13 OttoGrafJournal Vol. 9, 1998

H.W. REINHARDT, A. PFINGSTNER Concrete I 1,8 Absorbed volume [l/m 2 ] 1,6 1,4 1,2 1,0 0,8 0,6 DI/1 DI/2 DI/3 DI/4 DI/5 SI/1 SI/2 SI/3 SI/4 SI/5 S I/3 D I/2 D I/1 D I/3 D I/5 D I/4 SI/5 S I/1 SI/4 S I/2 0,4 0,2 0,0 0 1 2 3 4 5 6 7 8 9 Square root of time [h 1/2 ] Fig. 1: Absorbed volume vs. time for individual tests, concrete I, D = diesel, S = Super Absorbed volume [l/m 2 ] 1,8 1,6 1,4 1,2 1,0 0,8 0,6 0,4 0,2 Concrete II DII/1 DII/2 DII/3 DII/4 DII/5 SII/1 SII/2 SII/3 SII/4 SII/5 SII/4 SII/3 S II/5 S II/1 S II/2 D II/4 D II/5 II/3 D II/2 D II/1 0,0 0 1 2 3 4 5 6 7 8 9 Square root of time [h 1/2 ] Fig. 2: Absorbed volume vs. time for individual tests, concrete II, D = diesel, S = super The penetration depth could only be measured after the specimen was split after 72 h. Diesel had an average penetrated 14.4 mm into concrete I and 14

Fuel penetration compared to water penetration into concrete 14.8 mm into concrete II. Gasoline evaporated too quickly and did not permit a reading. 5. DISCUSSION OF RESULTS 5.1 Time function of penetration Theory predicts that absorption should be proportional to the square root of time. Figs. 1 and 2 support this relation approximately. This allows extrapolation of testing results to larger durations. 5.2 Comparison of diesel and gasoline If one compares the mean absorbed volume of diesel and gasoline one finds a ratio of 0.37 for concrete I and 0.36 for concrete II. These values are close to 0.44 as given in chapter 4.2 since one has to consider that diesel and gasoline are not pure liquids but that they are rather a mixture of about 200 individual components. The theoretical value of 0.44 is only valid if the accessible pore space were the same for both liquids. However, the concretes tested contain a certain amount of water which fills the smallest pores and which may act on the two liquids differently. 5.3 Concrete composition The main difference between concrete I and II is the watercement ratio or even more pronounced the waterbinder ratio. The watercement ratios are 0.50 and 0.32 the waterbinder ratios 0.50 and 0.29 if silica fume is supported to have the same reactivity as cement. This means that the porosity and the pore sizes are different for both concretes. Although not measured the total porosity can be assessed by assuming that cement and silica fume have hydrated to a degree of hydration of 90% of the possible maximum value. The capillary porosity which is responsible for the transport of fluids would then be [HANSEN, T.C., 1986] 15 OttoGrafJournal Vol. 9, 1998

H.W. REINHARDT, A. PFINGSTNER Vcap = ( w/ c 036α. ) mass of binder. (1) The degree of hydration of concrete I is 0.90, and only 0.62 for concrete II because the maximum would be 0.29/0.42. Concrete I has 56.3 l capillary pores per m 3 concrete and concrete II 34.1 l/m 3. A lower waterbinder ratio not only reduces pore space but also the size of the pores. Since the absorption speed is greater with larger pores concrete I should take up the liquid quicker which has been demonstrated by Fig. 1 compared to Fig. 2. On the other hand the penetration depth of diesel is almost the same for concrete I and II. This is also acceptable because absorbed volume per area V and penetration depth e are related via porosity ε V = ε e (2) From eq. (2) the effective porosity can be calculated, i. e. the porosity whichisreachedbydiesel: ε eff = V / e (3) From the mean values of V from Figs. 1 and 2 which are about 0.54 l/m 2 for concrete I and 0.27 l/m 2 for concrete II after 72 h and mean values of e which are 14.4 and 14.8 mm (see chapter 4.2) it follows that ε eff is equal to 3.8% and 1.8% for concrete I and II. This means that the effective porosity is less than the above assessed porosity, i.e. ε eff /ε ass = 38/56.3 = 0.67 and 18/34.1 = 0.53. The result is at least not in contradiction to what has been stated in chapter 5.2. 5.4 Comparison between water and organic liquids Table 2 has shown that water penetrates more into concrete which has dried for a certain period of time. The differences between concrete I and II are rather small and also the type of testing, either according to DIN of ISO, does not create a significant effect. If one compares the water penetration into a wet 16

Fuel penetration compared to water penetration into concrete specimen after 28 d with the penetration of diesel into a specimen which was 70 days old at testing one can state an almost identical penetration depth. That this happened may be by chance but it has been found at least for two dense concretes which are suitable for pavings of filling stations or similar barriers for environmental protection. 6. CONCLUSION Concrete is a useful material for environmental protection structures since it retains organic liquids in spite of its porosity. Testing of the penetration of organic liquids is rather specialized while water penetration testing follows a standard procedure. A limited series of testing has shown that diesel penetrates into a dense partly dried concrete after 72 h as much as water does in a wet concrete. Further testing is recommended in order to prove whether this result is valid for other concretes. 7. ACKNOWLEDGEMENT The authors would like to thank Dr.Ing. Abebe Dinku for his valuable contribution. REFERENCES DEUTSCHER AUSSCHUSS FÜR STAHLBETON: Richtlinie "Betonbau beim Umgang mit wassergefährdenden Stoffen", Teil 1 bis 6, Beuth, Berlin, 1996 DIN 1048 Teil 5: Prüfverfahren für Beton; Festbeton, gesondert hergestellte Probekörper, 1991 HANSEN, T. C.: Physical structure of hardened cement paste. A classical approach. Materials and Structures 19, no. 114, 1986, p. 423436 17 OttoGrafJournal Vol. 9, 1998

H.W. REINHARDT, A. PFINGSTNER ISO/DIS 7031: Festbeton; Bestimmung der Eindringtiefe von Wasser unter Druck, 1963 18