GE Measurement & Control

Similar documents
BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration

CO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure

BAPI-Stat 3 Room Sensor

VOC Duct and Rough Service Sensor

QUICK START GUIDE VAV CONTROLLERS & WALL SENSORS rue Charles, Suite 100, Mirabel, QC, J7J 1X9

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

Air Quality Solutions

Installation and Operation Instructions DLP Series

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions

EGQ 212: Duct transducer, CO 2 and temperature

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

Figure 1: WPR2 Dimensions and Hardware

Direct-Coupled ControlSet Actuators (120/180/320 in-lbs.) Installation Guide 2-7/16"

Compact Low Pressure Sensor

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

LF Series At A Glance

VOC Room Sensor in the BAPI-Stat 3 Enclosure with Differential Ground Configuration

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Carbon Monoxide Transmitter

Digital Room Thermostats with Touch Screen LCD

ECONOMIZERS. 5/2012 Supersedes

Introduction to Carrier sensors... 1 ZS Sensors... 3 Specifications... 5 CO2 sensor installation... 6 Rnet Configuration... 6

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

TS Temperature Sensor and Transducers. Product Bulletin. Wide range of mounting types and signal outputs

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

GS-AQ1000 VOC Indoor Air Quality Sensors

Accutrol, LLC Product Sheet. VTS Series. US Patents 6,991,177 & 7,543,759. Digital Airflow Measurement Station

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

ELECTRONIC THERMOSTAT: T901

MF /MS Series

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

Accutrol, LLC Product Sheet H-AVC5000. US Patents 6,991,177 & 7,543,759. Specially Made for Vivarium Cage Racks

LF Series Spring Return Direct Coupled Actuator

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

Table of Contents. Carrier Sensors

INTECH Micro 2300-RTD6

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

Output signal active humidity DC V 22DTH-51MB DC V, DC V DC V DC V DC V DC V

Acid Resistant AVC6000

M9216 Series Electric Spring Return Actuators

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Powers TM Controls EA 338 Electronic Actuator

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

RESISTIVITY MONITOR/CONTROLLERS

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

MF4E MF4E

2-Color Display High-Precision Digital Pressure Switch

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

1100 Series Piston Type Differential Pressure Gauges

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

MS Application. Features. Proportional Valve Actuator General Instructions

THC-2, THC-3, THCR-4, THCR-5. Enthalpy Control. General Instructions APPLICATION SPECIFICATIONS. ACCESSORIES None

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

SAX Electronic Valve Actuator

Minimum 18 in-lb Torque

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

Signet Pressure Transmitter

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers

Hour Meter Series HM36

Condensed Version of Operator s Manual For The VI/VP700 Series Flowmeter and VI800 Series Flowmeter

TEGAM HTRHSERIES. High Temperature, Relative Humidity/ Temperature Probe Transmitter

Laboratory Room Controller

Non-Spring Return EconoDrive Floating Actuator

YCCS TE-6800 Series Temperature Sensors

Versatile and Powerful

Versatile and Powerful

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

SERIES 700 ANALOG ELECTRONIC CONTROLS

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

MEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information

ABB Component Drives ACS150, 0.5 to 5 Hp

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Transcription:

GE Measurement & Control Telaire Ventostat 8000 Series CO 2 Sensor User Instructions Installing the Sensor!WARNING! Before performing service or maintenance operations on the systems, turn OFF main power switches to the unit. Electric shock can cause personal injury. Please read and follow the wiring instructions precisely; miswiring may cause permanent damage to the product. Basic Installation for Non-Display Units 1. Separate the case into its front and rear sections. 2. Secure the rear section of the case to the wall or junction box using the supplied screws, and make necessary wire connections. 3. Mount the Controller on the base by aligning the top clips and then securing to the bottom clips. Secure the Ventostat with the supplied set screw. A one-minute stabilization warmup will take place. Output Jumper Selections GE Measurement & Control 6860 Cortona Dr., Suite B Goleta, CA 93117 www.ge-mcs.com Basic Installation for Display Units 1. Separate the case into its front and rear sections. 2. Secure the rear section of the case to the wall or junction box using the supplied screws, and make necessary wire connections. 3. Mount the Controller on the base by aligning the top clips and then securing to the bottom clips. Secure the Ventostat with the supplied set screw. A one-minute stabilization warmup will take place. 4. When fitting the T8300 (pitot tube version), complete the installation by screwing the tube connectors to the input ports on the sensor. The tubing connectors can be attached to either input port. It will not affect the performance of the sensor. (See page 3 for further instructions.) Internal Label for Non-Display Units Output Jumper Selections (a) (b) 0-10V 0-5 V Jumper Settings for Non-Display (a) and Display (b) Units Note: Example b shows outputs of CO 2 4-20 ma and CO 2 0-10 V, humidity 4-20 ma, and active temperature 0-5 V. Internal Label for Display Units T63216-007 May 2013 Page 1 of 4

Ventostat Wiring Diagrams The Ventostat family of products has two basic configurations. One configuration provides three active outputs (CO 2, RH and temperature) and an independent thermistor. It has an output terminal block with pins #1, 2 and 3. The other configuration provides only CO 2 outputs and an independent thermistor and has no terminal block with pins 1, 2, and 3 installed. For electrical wiring and power supply requirements, these two configurations are identical; please follow the specific instructions for wiring. The recommended wire gauge is 18-22 AWG (1.0 to 0.75 metric).!warning! Ventostat products have three terminal pins that are connected inside the sensor to a common/ground: pin #2, 5 and 7 on the I/O terminal blocks and pin #2 on the power block. Do NOT connect positive (hot) 24 VAC power line to terminal number 2 of the terminal block. Figure 2: Display Unit Wiring for 4-Wire System, AC Power Caution! The T8100 Ventostats are either 3-wire or 4-wire type configurations, powered by either AC or DC voltage. They are not 2-wire or loop-powered devices. Wiring the units as 2-wire or loop-powered devices will irreparably damage the sensors and void the warranty. Note: For temperature measurements, Ventostat models contain a passive thermistor (terminal pins #4 and 5), which is electrically isolated from the other circuitry and should be wired independently from active CO2/RH/temperature outputs. The thermistor has no connection to the Ventostat common ground and/or power. The active temperature output has the same common (ground) as CO 2 and RH outputs. Figure 3: Non-Display Unit Wiring for 3-Wire System, AC Power Figure 4: Non-Display Unit Wiring for 4-Wire System, AC Power Figure 1: Display Unit Wiring for 3-Wire System, AC Power Figure 5: Wiring CO 2 Sensor Voltage Output to Honeywell M7415 Damper Actuator with W7459 Logic Module Page 2 Telaire Ventostat 8000 Series

Sensing Duct CO2 Concentrations Duct-Mounting the Enclosures Ventostat products can be installed inside the return air ductwork, if needed. As an alternative, please consider the T8031 unit. When mounting these products inside the ductwork, seal the hole around the wires and leave the duct insulation in place to prevent condensation which may damage the sensor. Pitot Tube Installation for T8300 and T8300-D Install the mounting bracket, then install the pitot tube assembly as follows: Note: The length of the Tygon tubing is 6 ft. (1.8 m) with the optional T62892 pitot kit for the T8300. In order to maintain optimum accuracy, the tubing should not be lengthened. If the sensor is mounted closer than 3 ft. (0.9 m) the excess tubing should be shortened to avoid interference with mechanical or moving devices. Accessory Enclosures Model T1508 Duct Mount Enclosure (Aspiration Box) The T8100/T8200/T8300 units can be installed inside a Model 1508 Duct Mount Enclosure. Model T1552 Outside Air Measurement Enclosure This NEMA-3R weatherproof enclosure includes thermostat and allows installing the sensor in environments with temperatures down to -40 F. Model T1505 Harsh Environment Enclosure For extreme environments where the sensor might be subjected to condensation or water spray such as those found in greenhouses or breweries- NEMA-3R rated. Ventostat Specifications 1. To mount the pitot tube, drill one 7/8 hole through the duct. 2. Insert the pitot tube and mark the two remaining holes for the mounting screws. 3. Punch or drill the two marked holes. 4. Note the direction of airflow in the duct. 5. Note the marking on the pitot tube flange and insert so that it is properly aligned with the airflow. 6. To ensure an air tight seal, make sure the mounting surface of the duct is clear of dirt or obstructions. Then, attach the pitot tube to the duct with sheet metal screws or rivets. 7. Check the length of the tubing before attaching to the sensor. The tubing should connect without stretching or pulling. If the length is long enough to create a loop or bind in the tubing, it should be shortened. 8. To shorten the tubing, remove the connectors that attach to the sensor and cut the tubing to length. 9. Replace the tubing connectors by using a twisting or screwing motion. Verify the connection is secure. Note: If the tubing length has been shortened, be sure the in-line filter is replaced on the pitot tube connector marked with an H. Sensing Method Non-dispersive infrared (NDIR) absorption Gold-plated optics Patented ABC Logic self calibration algorithm CO 2 Measurement Range T8100/T8200/T8300 0 to 2000 ppm (0 ppm = 0 V, 4 ma; 2000 ppm = 10/5V, 20 ma) T8100/T8200/T8300-5P models 0 to 5000 ppm (0 ppm = 0 V, 4 ma; 5000 ppm = 10/5V, 20 ma) CO 2 Accuracy ±30 ppm or 3% of reading, whichever is higher* Power Supply Requirements 18-30 VAC RMS, 50/60 Hz, or 18 to 42 VDC, polarity protected *CO 2 accuracy statement excludes standard gas used for calibration that has an accuracy of 2%. In addition, there is a potential digital to analog error of up to 1%. Telaire Ventostat 8000 Series Page 3

Power Consumption Typical 0.7 W at nominal voltage of 24V AC RMS Temperature Dependence 0.2% FS per C (±0.11% per F) Stability T8100/T8300 - Single Channel <2% of FS over life of sensor (15 years) T8200 - Dual Channel <5% of FS or <10% reading annual over life of sensor (10 years) Pressure Dependence 0.135% of reading per mm Hg Certifications CE and RoHS compliant Signal Update Every 5 seconds CO 2 Warm-up Time < 2 minutes (operational) 10 minutes (maximum accuracy) Operating Conditions 32 F to 122 F (0 C to 50 C) 0 to 95% RH, non-condensing Storage Conditions -40 F to 158 F (-40 C to 70 C) Flammability Classification UL94 5VA Thermistor Type NTC 10 K thermistor Thermistor Accuracy ±1 C (15 to 35 C) Page 4 RH Sensing Element Capacitive polymer sensor RH Range 0% to 99% RH (non-condensing) RH Accuracy (25 C) ±2.5% RH (20 to 80% RH) ±3.5% RH (<20% and >80% RH) Active Temperature Accuracy ±0.8 C @ 22 C Active Temperature Range 0 to 50 C ABC Logic Self Calibration System ABC Logic (Automatic Background Calibration) self calibration allows the sensor to continually recalibrate itself when the indoor concentrations drop to outside levels while the building is unoccupied. Generally a building must be regularly unoccupied for 4 hours or more for this self-calibration system to operate properly. Under these conditions, ABC Logic should maintain sensor calibration over the lifetime of the sensor. The ABC Logic should be turned OFF where a building is continuously occupied 24 hours per day, or where there could be significant sources of non-occupant related CO 2 such as greenhouses, breweries and other industrial and food processing applications. Output Analog 0 to 5 V, (100 output impedance) 0 to 10 V (100 output impedance) and 4 to 20mA (R L maximum 500 ) available simultaneously for CO 2 output Digital to analog error ±1% Warranty/Other Warranty 18 months parts and labor This product is covered by one or more of the following patents: 5,650,624 / 5,721,430 / 5,444,249 / 5,747,808 / 5,834,777 / 5,163,332 / 5,340,986 / 5,502,308 / 6,344,798 / 6,023,069 / 5,370,114 / 5,601,079 / 5,691,704 / 5,767,776 / 5,966,077 / 6,107,925 / 5,798,700 / 5,945,924 / 5,592,147 / 6,255,653 / 6,250,133 / 6,285,290 Warranty Repairs GE Sensing will repair Telaire product that fails to meet the terms provided for in the Return and Warranty Policy Statement (See, http:// www.ge-mcs.com/en/services-and-support.html).warranty period shall start from date of manufacture and be based on product category and Telaire Ventostat 8000 Series

type of equipment as specified in Table 1: Product Warranty Periods. For all warranty repairs, GE Sensing will bear all product repair parts, labor, and standard ground shipping charges. Telaire Ventostat 8000 Series Page 5

GE Measurement & Control Installing the Sensor Telaire Ventostat T8100 NS and NSP Series CO 2 Sensor User Instructions!WARNING! Before performing service or maintenance operations on the systems, turn OFF main power switches to the unit. Electric shock can cause personal injury. Please read and follow the wiring instructions precisely; miswiring may cause permanent damage to the product. Basic Installation for T8100-NS and NSP 1. Separate the case into its front and rear sections. 2. Secure the rear section of the case to the wall or junction box using the supplied screws, and make necessary wire connections. 3. Mount the Controller on the base by aligning the top clips and then securing to the bottom clips. Secure the Ventostat with the supplied set screw. A one-minute stabilization warmup will take place. GE Measurement & Control 6860 Cortona Dr., Suite B Goleta, CA 93117 www.ge-mcs.com Internal Label T63351-002 May 2013 Page 1 of 4

T8100-NS/NSP Wiring Diagrams The Ventostat T8100-NS and T8100-NSP family of products has two basic configurations. T8100-NS provides simultaneous voltage and current outputs for CO 2, an independent thermistor with Night Setback Override Button. The button shorts the thermistor when depressed. Thermistor 10 KΩ Type II and Night Setback Button Slide potentiometer T8100-NSP only Left 0 KΩ Right 100 KΩ (+) ( - common) ( - common) (+) 18-30 VAC RMS L2 L1 T8100-NSP provides simultaneous voltage and current outputs for CO 2, an independent thermistor with Night Setback Override Button and slide Potentiometer that can be used to control thermostat set point. The slide potentiometer has 0 KOhm value in the left position and 100 KOhm value in the right position; the middle position corresponds to 50 KOhm value. CO2 4-20 ma out Use either or both CO2 outputs CO2 0-10/5 V out Jumper selectable 8 7 6 3 2 1 2 1 _ + The functional block diagram of T8100-NSP is presented in Figure 1. The electrical circuits of thermistor, Night Setback Overage Button and potentiometer have common signal between each other as shown in Figure 1. The electrical circuits of the CO 2 sensor power supply and outputs, from one side and thermistor, Night Setback Override Button and Potentiometer from the other, are electrically isolated from each other. For electrical wiring and power supply requirements, these two configurations are identical. The recommended wire gauge is 18-22 AWG (1.0 to 0.75 metric).!warning! Ventostat T8100-NS/NSP products have two terminal pins that are connected inside the sensor to a common/ground: pin #7 on the I/O terminal blocks and pin #2 on the power block. Do NOT connect positive (hot) 24 VAC power line to terminal number 2 of the terminal block. Figure 2: T8100-NS/NSP Wiring for 3-Wire System, AC Power Thermistor 10 KΩ Type II and Night Setback Button Slide potentiometer T8100-NSP only Left 0 KΩ; Right 100 KΩ CO2 4-20 ma out Use either or both CO2 outputs Common (ground) CO2 0-10/5 V out Jumper selectable (+) ( - common) ( - common) (+) 8 7 6 Figure 3: T8100-NS/NSP Wiring for 4-Wire System, AC Power 3 2 1 18-30 VAC RMS 2 1 _ + L2 L1 Caution! The T8100 Ventostats are either 3-wire or 4-wire type configurations, powered by either AC or DC voltage. They are not 2-wire or loop-powered devices. Wiring the units as 2-wire or loop-powered devices will irreparably damage the sensors and void the warranty. NS button Thermistor 1 2 AC+/DC+ AC-/DC-/GND CO2 sensor 4-20 ma current source 0-10/ 0 5V voltage source 7 6 3 2 1 8 THERM COM POT (T8100 NSP only) I CO2 GND V CO2 Figure 1: T8100-NS/NSP Functional Block Diagram Page 2 Telaire Ventostat T8100 NS and NSP Series

Ventostat Specifications Sensing Method Non-dispersive infrared (NDIR) absorption Gold-plated optics Patented ABC Logic self calibration algorithm CO 2 Measurement Range T8100 0 to 2000 ppm (0 ppm = 0 V, 4 ma; 2000 ppm = 10/5V, 20 ma) CO 2 Accuracy ±30 ppm or 3% of reading, whichever is higher* Power Supply Requirements 18-30 VAC RMS, 50/60 Hz, or 18 to 42 VDC, polarity protected Power Consumption Typical 0.7 W at nominal voltage of 24V AC RMS Storage Conditions -40 F to 158 F (-40 C to 70 C) Flammability Classification UL94 5VA Thermistor Type NTC 10 K thermistor Thermistor Accuracy ±1 C (15 to 35 C) Night Setback Override Button (NS and NSP) Shorts the thermistor output when depressed Slide Potentiometer (NSP Only) Left (stop) 0k Ohms (±5k ) Center 50k Ohms (±7.5k ) Right (stop) 100k Ohms (±15 ) Temperature Dependence 0.2% FS per C (±0.11% per F) Stability <2% of FS over life of sensor (15 years) Pressure Dependence 0.135% of reading per mm Hg Certifications CE and RoHS compliant Signal Update Every 5 seconds CO 2 Warm-up Time ABC Logic Self Calibration System ABC Logic (Automatic Background Calibration) self calibration allows the sensor to continually recalibrate itself when the indoor concentrations drop to outside levels while the building is unoccupied. Generally a building must be regularly unoccupied for 4 hours or more for this self-calibration system to operate properly. Under these conditions, ABC Logic should maintain sensor calibration over the lifetime of the sensor. The ABC Logic should be turned OFF where a building is continuously occupied 24 hours per day, or where there could be significant sources of non-occupant related CO 2 such as greenhouses, breweries and other industrial and food processing applications. Output Analog 0 to 5 V, (100 output impedance) 0 to 10 V (100 output impedance) and 4 to 20mA (R L maximum 500 ) available simultaneously for CO 2 output Digital to analog error ±1% < 2 minutes (operational) 10 minutes (maximum accuracy) Operating Conditions 32 F to 122 F (0 C to 50 C) 0 to 95% RH, non-condensing *CO 2 accuracy statement excludes standard gas used for calibration that has an accuracy of 2%. In addition, there is a potential digital to analog error of up to 1%. Telaire Ventostat T8100 NS and NSP Series Page 3

Warranty/Other Warranty 18 months parts and labor This product is covered by one or more of the following patents: 5,650,624 / 5,721,430 / 5,444,249 / 5,747,808 / 5,834,777 / 5,163,332 / 5,340,986 / 5,502,308 / 6,344,798 / 6,023,069 / 5,370,114 / 5,601,079 / 5,691,704 / 5,767,776 / 5,966,077 / 6,107,925 / 5,798,700 / 5,945,924 / 5,592,147 / 6,255,653 / 6,250,133 / 6,285,290 Warranty Repairs GE Sensing will repair Telaire product that fails to meet the terms provided for in the Return and Warranty Policy Statement (See, http:// www.ge-mcs.com/en/services-and-support.html).warranty period shall start from date of manufacture and be based on product category and type of equipment as specified in Table 1: Product Warranty Periods. For all warranty repairs, GE Sensing will bear all product repair parts, labor, and standard ground shipping charges. Page 4 Telaire Ventostat T8100 NS and NSP Series