Results of annual simulation

Similar documents
Example printout. Building project. SDC Example. Dyfi Eco Park SY20 8AX Machynlleth UK. Mr C. Laughton Phone:

Yield Reduction Due to Shading:

Yield Reduction Due to Shading:

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow

Energy Produced by PV Array (AC):

NE (SE) Beam

Sunrise: 05:48 N (S) Beam

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

SOLAR ENERGY ASSESSMENT REPORT. For 115 kwp. Meteorological Data Source Meteonorm. Date 18 October, Name of Place California.

W (W) Beam

Company name: Created by: Phone:

DIN W.-Nr AISI 304

Solargis Report. Solar Resource Overview. Plataforma Solar de Almeria, Spain. 03 August Solargis s.r.o.

Meter Insights for Downtown Store

Modeling and Comparison of Dynamics of AC and DC Coupled Remote Hybrid Power Systems

Daily output in average month 77 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

100kW GROUND MOUNTED SOLAR PHOTOVOLTIC POWER PLANT DETAILED PROJECT REPORT AERO SPACE MATERIALS PVT LTD

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Solargis Report. Solar Resource Overview. Plataforma Solar de Almeria, Spain. 03 August Solargis s.r.o.

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Design Criteria Data

Daily output in May 32 m³

Design Criteria Data

Design Criteria Data

Large scale solar power plant in Nordic conditions. Antti Kosonen, Jero Ahola, Christian Breyer, Albert Albó

Application of HOMER Software in Wind and Solar Resources Integration

SunSwitch setting in PumpScanner. Daily output in average month 219 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

ANCR CRU Statistics February 2007 to December 2007

Design Criteria Data

Design Criteria Data

Daily output in April 193 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Design Criteria Data

Design Criteria Data

Design Criteria Data

The impact of electric vehicle development on peak demand and the load curve under different scenarios of EV integration and recharging options

4TCH Submersible Pumps. Installation and Operating Manual

Master Class on PVsyst Solar Project Designing Tool 7 th June 2013

Todae Solar s 1.22 MWp Rooftop Solar Photovoltaic Installation for Stockland Shellharbour, NSW.

Graph #1. Micro-Generation Generating Units in Alberta 20

A 3-Year Case Study of a Residential Photovoltaic System with Microinverters

Sun Sensor setting in PumpScanner Daily output in average month 52 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

4HS MultiPower Submersible Pumps. Installation and Operating Manual.

Report energy requirements Ljusdal

4HS MultiPower Submersible Pumps. Installation and Operating Manual. M u l t i P o w e r. man4hs_mp_11_eng

SunSwitch setting requirements min. 15 % Daily output in average month 154 m³

Past Due. Account Charges. Contract Charges Security Deposit Due - Jun 09, , Customer Service. Jun 19, PAST DUE $1,693.

PDR Energy Baseline Alternative. Proposal for Discussion October 27, 2015

Smart community clustering for sharing local green energy. Yoshiki Yamagata, Hajime Seya and Sho Kuroda

Balance from your previous bill $0.00 Meter # Basic Charge: 17 $ /day 3.23* Energy charge:¹ 2

Optimization and Modeling of PV/ FC/Battery Hybrid Power Plant for Standalone Application

OFF GRID PV POWER SYSTEMS SYSTEM DESIGN GUIDELINES FOR THE PACIFIC ISLANDS

Up and Down Months of the Stock Market

Total Production by Month (Acre Feet)

SOLAR PV CAROUSEL TRACKERS FOR BUILDING FLAT ROOFTOPS: THREE CASE STUDIES

Energy use in potato stores

Fact Sheet Sky CPC 58

NJ Solar Market Update As of 6/30/15

Climatography of the United States No

ANCR CRU Statistics Februa.. to December 2007

Climatography of the United States No

2012 DFW Solar Home Tour October 6, 2012 Reference Solar PV

Vunivau, Bua Province Vanua Levu, Fiji Solar Home System Design. Luis A. Vega, Ph.D.

Construction Sector Indices

University of Michigan Eco-Driving Index (EDI) Latest data: October 2017

This presentation was given as part of a workshop on November 14, Presenters were:

GAIA Energy Co., Ltd. Always with Human, Nature and Happiness

STATISTICS BOTSWANA ELECTRICITY GENERATION & DISTRIBUTION 2016/2 STATS BRIEF, FIRST QUARTER Copyrights Statistics Botswana 2016

WIM #37 was operational for the entire month of September Volume was computed using all monthly data.

Macroeconomic Outlook. Presented by Dr. Bruce A. Scherr Chairman of the Board Chief Executive Officer Emeritus

FY2/18 2Q(March 2017~August 2018)

DRAFT. Total Month Average Point (MAP) A Massage 4/30/2014 8/1/2015 A CENTER E

Date Event or Holiday :Sun, 2:Mon North Orchard Delong Preschool North Orchard Delong Preschool

Techno-Economic Design of 432 KW P Grid Interactive Rooftop SPV Power Plant at Delhi Technological University (DTU)

Facilities Energy Report Fiscal Year 2016 Third Quarter

Field Application of Fuel Cells Increasing Energy Security. Jon Rice, Ultra Electronics

Transcription:

2 x Vitosol 100-FM SVKF Total gross surface area:4,46 m² Azimuth: 0 Incl.: 30 160 Liters/Day 50 C Gas-fired boiler 26 kw Vitocell 100-B Vol : 250 l Results of annual simulation Installed collector power: 3,12 kw Installed solar surface area (gross): 4,46 m² Irradiation on collector surface (active): 4.636,04 kwh 1.153,24 kwh/m² Energy delivered by collectors: 1.840,47 kwh 457,83 kwh/m² Energy delivered by collector loop: 1.588,90 kwh 395,25 kwh/m² DHW heating energy supply: Solar energy contribution to DHW: Energy from auxiliary heating: 2.632,04 kwh 1.454,06 kwh 1.452,4 kwh Natural gas (H) savings: 211,1 m³ CO2 emissions avoided: 446,33 kg DHW solar fraction: 50,0 % Relative savings of supplementary energy (DIN EN 12977): 53,0 % System efficiency: 31,4 % Page 2 from 12

Site Data Climate data Location: BRUSSELS NATIONAL Climate data record: BRUSSELS NATIONAL Total annual global irradiation: 1014,311 kwh/m² Latitude: 50,9 Longitude: -4,53 Domestic hot water Average daily consumption: 0,16 m³ Desired temperature: 50 C Consumption profile: Detached house (evening max) Cold water temperature: February: 9 C August: 13 C Circulation: no Page 3 from 12

System Collector loop Manufacturer: Viessmann Werke GmbH & Co Type: Vitosol 100-FM SVKF Number: 2,00 Total gross surface area: 4,46 m² Total active solar surface area: 4,02 m² Inclination (Tilt Angle): 30 Orientation: 180 Azimuth: 0 Dual coil indirect hot water tank Manufacturer: Viessmann(141 FM) Type: Vitocell 100-B Volume: 0,25 m³ Auxiliary heating Manufacturer: Type: Nominal output: Standard Gas-fired boiler 26 kw Legend With test report Solar Keymark Page 4 from 12

Solar energy consumption as percentage of total consumption [ kwh ] per week 70 65 60 55 50 45 40 35 30 25 20 15 10 5 feb mrt apr mei jun jul aug sep okt nov dec Solar contribution 1.454 kwh Total energy consumption 2.906 kwh Daily maximum collector temperature [ C ] 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 jan feb mrt apr mei jun jul aug sep okt nov dec These calculations were carried out by - the simulation program for solar thermal heating systems The results are determined by a mathematical model calculation with variable time steps of up to 6 minutes. Actual yields can deviate from these values due to fluctuations in climate, consumption and other factors. The system schematic diagram above does not represent and cannot replace a full technical drawing of the solar system. Page 5 from 12

Energy balance schematic Legend 1 Irradiation on collector surface (active) 4.636 kwh 1.1 Optical collector losses 1.289 kwh 1.2 Thermal collector losses 1.507 kwh 2 Energy from collector array 1.840 kwh 2.1 Solar energy to storage tank 1.589 kwh 2.5 Internal piping losses 210 kwh 2.6 External piping losses 41 kwh 3.1 Tank losses 409 kwh 6 Final energy 1.862 kwh 6.1 Supplementary energy to tank 1.452 kwh 9 DHW energy from tank 2.632 kwh Page 6 from 12

Glossary 1 Irradiation on collector surface (active) Solar energy irradiated onto tilted collector area (active surface area) 1.1 Optical collector losses Reflection and other losses 1.2 Thermal collector losses Heat conduction and other losses 2 Energy from collector array Energy output at collector array outlet (i.e. before piping) 2.1 Solar energy to storage tank Energy from collector loop to storage tank (minus piping losses) 2.5 Internal piping losses Internal piping losses 2.6 External piping losses External piping losses 3.1 Tank losses Heat losses via surface area 6 Final energy Final energy supply to system. This can be supplied from natural gas, oil or electricity (not including solar energy) and takes efficiency into account. 6.1 Supplementary energy to tank Supplementary energy (e.g. boiler) to tank 9 DHW energy from tank Heat from tank (exluding circulation) for DHW consumption Page 7 from 12

Results of annual simulation Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec DHW system Savings Natural gas (H) in m³ 211,1 5,6 7,6 14,1 20,2 26,1 29,9 29,1 31,8 21,8 15,7 6,4 2,8 CO2 emissions avoided in kg 446,3 11,8 16,2 29,9 42,7 55,1 63,2 61,4 67,3 46,2 33,2 13,5 5,9 DHW solar fraction in % 50,0 18,2 26,8 49,1 65,2 72,5 83,6 80,1 79,2 66,2 49,5 22,2 9,2 System efficiency in % 31,4 31,5 32,4 32,7 32,1 30,1 30,3 28,4 32,6 32,1 35,6 32,5 25,5 Solar energy contribution to DHW in kwh 1.454 50 68 125 165 176 182 167 182 140 119 57 25 E - Solar loop to tank in kwh 1.589 54 72 134 178 192 200 188 199 154 128 61 28 Energy: Aux. heating in kwh 1.452 222 185 130 88 67 36 42 48 71 121 199 245 Climate Outside temperature in C 11,0 4,0 4,7 7,0 10,2 14,1 16,7 18,4 18,2 15,2 11,7 7,8 4,0 Global radiation - horizontal in kwh/m² 1.014 24 37 74 114 144 153 148 129 91 58 26 16 Position of sun - altitude in 12,7 4,0 6,6 11,0 16,4 21,1 23,3 22,3 18,3 12,9 8,0 4,6 3,3 Position of sun - azimuth in -5,6-6,7-7,2-6,8-5,6-5,2-5,7-6,3-6,2-5,1-3,8-3,7-5,1 Wind speed in m/s 3,9 5,0 4,6 4,3 3,5 3,6 3,2 3,4 3,1 3,2 3,8 4,4 4,3 Page 8 from 12

Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Hot water consumption DHW heating energy supply in kwh 2.632 259 237 238 226 202 193 174 193 190 220 243 258 DHW heating energy requirement in kwh 2.632 259 237 238 226 202 193 174 193 190 220 243 258 Circulation losses in kwh 0 0 0 0 0 0 0 0 0 0 0 0 0 Cold water temperature in C 11,0 9,2 9,0 9,3 10,1 11,1 12,1 12,8 13,0 12,7 11,9 10,9 9,9 DHW temperature in C 49,9 49,9 49,9 49,7 49,9 49,9 50,0 49,9 49,8 49,9 49,8 49,9 49,9 Preset DHW consumption in m³ 58,0 5,5 5,0 5,0 4,9 4,5 4,4 4,0 4,5 4,4 5,0 5,4 5,5 DHW - consumption in m³ 53,4 5,3 4,8 4,8 4,4 3,9 3,8 3,4 4,0 3,9 4,7 5,1 5,3 Solar loop Max collector temperature in C 33,2 18,2 21,6 30,3 38,5 42,7 45,5 46,8 45,1 40,2 32,1 22,0 14,4 Collector loop Energy from collector loop (CL 1) in kwh 1.589 54 72 134 178 192 200 188 199 154 128 61 28 Collector loop efficiency (CL 1) in % 34,3 34,0 34,6 35,2 34,7 32,9 33,3 31,9 35,6 35,4 38,4 35,3 28,4 Collector loop reference temperature (CL 1) in C 23,2 13,0 14,0 18,0 24,3 30,2 33,9 37,7 30,7 27,7 19,7 15,3 12,7 T Coll out (CL 1) in C 43,0 28,3 31,5 36,1 45,0 48,6 49,7 49,9 47,6 44,1 35,7 33,8 24,7 Page 9 from 12

Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Volume flow (CL 1) in m³ 363,9 14,9 18,1 31,1 37,9 42,6 44,8 43,7 42,0 35,2 30,3 13,9 9,4 Control factor (CL 1) in % 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 Collector array spec. DNI (CL 1) in kwh/m² 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 G opt. loss deduct. (CL 1) in kwh/m² 832,7 28,2 37,4 68,9 92,9 105,1 107,8 105,2 100,7 78,2 59,9 31,3 17,2 Specific global radiation onto inclined surface area (CL 1) in kwh/m² 1.153,2 39,1 52,0 95,0 127,7 145,4 149,7 146,5 139,1 108,2 83,0 43,3 24,1 Spec. global radiation onto inclined, shaded surface (CL 1) in kwh/m² 1.153,2 39,1 52,0 95,0 127,7 145,4 149,7 146,5 139,1 108,2 83,0 43,3 24,1 Irradiation on gross surface area -unshaded- (CL 1) in kwh 5.143 175 232 424 570 649 668 653 620 483 370 193 107 Irradiation on gross surface area (CL 1) in kwh 5.143 175 232 424 570 649 668 653 620 483 370 193 107 Irradiation on active solar surface area -unshaded- (CL 1) in kwh 4.636 157 209 382 513 585 602 589 559 435 334 174 97 Irradiation on active surface area (CL 1) in kwh 4.636 157 209 382 513 585 602 589 559 435 334 174 97 Optical losses (CL 1) in kwh 1.289 44 59 105 140 162 168 166 154 121 93 48 28 Losses - external piping (CL 1) in kwh 41 2 2 4 5 5 5 5 5 4 3 2 1 Losses - internal piping (CL 1) in kwh 210 2 4 12 22 30 33 36 32 22 12 5 1 Thermal collector losses (CL 1) in kwh 1.507 56 72 127 169 195 195 194 170 135 98 58 39 Page 10 from 12

Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Collector outlet temperature (CL 1) in C 21,3 8,6 11,2 17,1 24,0 29,5 32,6 33,7 31,9 26,4 19,7 12,7 7,3 Collector temperature (CL 1) in C 20,7 8,4 10,9 16,6 23,2 28,7 31,8 32,9 31,1 25,8 19,2 12,4 7,2 Max collector temperature (CL 1) in C 31,1 16,9 20,0 27,6 35,7 40,5 43,2 44,3 42,5 37,5 29,9 20,7 13,9 Pump energy (CL 1) in kwh 91 4 5 8 9 11 11 11 11 9 8 3 2 Dual coil indirect hot water tank Tank losses in kwh 409 17 17 29 40 47 50 55 48 42 31 19 14 Change in internal energy in kwh 0 0 3-3 1 9-7 1 6-7 -2-2 0 Average temperature in C 36,8 28,2 29,0 34,1 39,9 42,9 45,0 46,7 43,1 41,0 34,7 29,3 27,1 Sensor: collector loop reference temperature in C 23,1 13,0 14,0 18,0 24,3 30,1 33,8 37,7 30,7 27,7 19,7 15,3 12,7 Sensor: collector loop switch-off temperature in C 53,8 51,9 51,8 51,8 55,1 56,2 56,6 57,5 54,6 54,8 51,8 51,8 51,8 Auxiliary heating sensor on in C 53,3 51,0 51,0 51,4 54,8 56,0 56,3 57,3 54,5 54,3 51,4 51,0 50,8 Sensor: auxiliary heating off in C 53,3 51,0 51,0 51,4 54,8 56,0 56,3 57,3 54,5 54,3 51,4 51,0 50,8 E-Electric heater rod in kwh 0 0 0 0 0 0 0 0 0 0 0 0 0 Consumption Natural gas (H) in m³ 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 Desired temperature auxiliary heating in C 50,0 50,0 50,0 50,0 50,0 50,0 50,0 50,0 50,0 50,0 50,0 50,0 50,0 Page 11 from 12

Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec solar tank losses in kwh 135 4 4 9 13 16 18 21 17 15 10 5 3 Gas-fired boiler Energy from boiler in kwh 1.452 222 185 130 88 67 36 42 48 71 121 199 245 Primary energy equivalent in kwh 1.862 262 218 152 112 96 61 75 87 118 160 233 288 Consumption Natural gas (H) in m³ 178,7 25,1 20,9 14,6 10,8 9,2 5,8 7,2 8,3 11,4 15,4 22,4 27,6 Return temperature in C 56,2 55,6 55,9 56,5 56,7 57,2 57,8 57,3 57,6 57,2 56,7 55,8 55,3 Supply temperature in C 63,0 63,0 63,0 63,0 63,0 63,0 63,0 63,0 63,0 63,0 63,0 63,0 63,0 Page 12 from 12