JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

Similar documents
JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

JUMO safetym TB/TW Temperature limiter, temperature monitor according DIN EN

INTERNATIONAL METAL ENGINEERING

Process controller. for pneumatic and electric actuators. Process controller V. Process controller

Analog input module. Brief description. Page 1/8. Data Sheet

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

JUMO ecotrans Lf 01/02

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

Screw-in resistance thermometers with plug connector

Industrial furnaces. Innovative solutions for your success

Ucontrol. 1 Data sheet. Multipurpose controllers for variable voltage 3 ~ fans PXDM Examples of application. 1.2 Equipment / Function

Industrial Furnace Construction

Dear Reader, For industrial furnace construction JUMO offers you a range of innovative solutions for different applications.

is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft

Safety technology/equipment

JUMO dtrans p20 DELTA

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Head form B Head form J Cable socket, angle type KOMBITEMP TEMPERATURE SENSOR WITH LOCAL DISPLAY. Including products with:

Thermocouples TE Measuring Insert. rigid Model TC 001 flexible Model TC 002. Electronic Temperature Measurement

JUMO MIDAS S05 Pressure transmitter Type

Differential Pressure Sensors

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Differential Pressure Sensors

HUMIDITY / TEMPERATURE TRANSMITTER

Plastics and Packaging Technology. Innovative solutions for your success

Flash Point Process Analyzer

Portable pressure calibrator, Wally Box III Model CPH7600

J1000. Compact Inverter Series.

BLU SERIES Battery Load Units

Thermocouple Model TC10-E, for additional thermowell

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Series 7000 Torque Sensor for PTO-shafts

KombiTemp. Head form B / Head form J Cable socket, angle type Diesel engine dial thermometers. Temperature Sensors with local display

Screw-in melt thermocouples

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Series 7000 Torque Sensor for PTO-shafts

Sensors and Accessories

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

See «Overview of types»

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

2271A Industrial Pressure Calibrator Extended specifications

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

TECHNICAL DESCRIPTION

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

EMERSON CLIMATE TECHNOLOGIES-EX

For reliable control of small, large or multi-system-type lubrication systems

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Time Electronics. Calibration, Test and Measurement. Portable Process and Pressure Calibration Instruments

Dawson DDM190D. Digital Multimeter User s Manual

Thermocouples Model TC10-E, for Additional Thermowell

Recording. Innovative solutions for the highest requirements

LMC 301 controller. For reliable control of small, large or multi-system-type lubrication systems

EPS/ELA-Series User Manual EPS/ELA 250W

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

J1000 D E F I 1000 J1000 J1000 J1000 J1000

DPI 620 Genii. Advanced Modular Calibrator and HART / Foundation Fieldbus Communicator. GE Measurement & Control

Thermocouples Model TC10-B, for Additional Thermowell

7526A Precision Process Calibrator. Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument

Callisto 100. Cold Filter Plugging Point Tester

JUMO MIDAS Pressure transmitter

KEPCO Will Point You In The Right Direction!

Moving Coil Indicators with direct temperature sensor input

Ground Resistance Tester Model 3620 & 3620 Kits

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Pressure transmitter for elevated media temperatures

AVL Particle Measurement System Aviation

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

DLRO10HDX 10 Amp Digital Low Resistance

The New Entris. Monolithic weigh cell for long-term high accuracy. Built-in applications and function keys for convenient operation

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

BLU SERIES Battery Load Units

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Operating Instructions Overcurrent Protection - Tester

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

TESTO 350 Upgrades / Accessories / Spare Parts. Replacement Sensors

Declaration of Conformity

Pressure Transmitter JUMO dtrans p30 Type

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

Model Number Structure

Operating Instructions (Translation)

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

KINAX SR 709 Transmitter for Position Feedback

High Voltage Safe Measurement Systems. CSM GmbH, Dr. Jürgen Braunstein. CSM GmbH Computer-Systeme-Messtechnik

Transcription:

Page 1/8 JUMO thermocor Portable measuring system for AMS2750 and CQI-9 Brief description The JUMO thermocor is a high-precision documenting test device with 12 analog inputs for thermocouples. The use of a specifically-designed integrated cold junction allows the device to meet the accuracy requirements of AMS2750 and CQI-9. It also has four universal analog inputs for connecting additional sensors such as RTD temperature probes. The JUMO thermocor's main benefits are the wide range of application possibilities and ease of operation. This is achieved by a large color touchscreen. The technology, housed in a robust case, makes JUMO thermocor the ideal test device. In addition, the JUMO thermocor communicates with the JUMO PCC/ PCA3000 software, thus enabling paperless documentation of the calibration processes and integration with calibration management. JUMO thermocor / Type 987050 Block diagram Special features 12 analog inputs for thermocouples (for AMS2750 and CQI-9) 4 universal analog inputs JUMO thermocor USB (host) (for retrieving data to a USB flash drive) Ethernet (LAN) (for connecting to a PC) 12 thermocouple inputs (for AMS2750 and CQI-9) Four universal analog inputs Easy operation via touchscreen Customer-specific configuration possible USB host interface for data export Ethernet interface for connecting to a local network (direct connection to PC also possible) System bus connection for additional measuring points Tamper-proof recording using TÜV certified JUMO PCC/PCA3000 software Voltage supply Bus Out (system bus) (for additional measuring points)

Page 2/8 Technical data Analog inputs Thermocouples (inputs 1 to 12 for AMS2750 and CQI-9) Designation Type Standard Measuring range Measuring accuracy Fe-CuNi "J" DIN EN 60584-200 to +1200 C ±0.6 K or ±0.1 % a, from 0 C NiCr-Ni "K" DIN EN 60584-200 to +1372 C ±0.6 K or ±0.1 % a, from 0 C NiCrSi-NiSi "N" DIN EN 60584-100 to +1300 C ±0.6 K or ±0.1 % a, from 0 C Pt10Rh-Pt "S" DIN EN 60584-50 to +1768 C ±0.6 K or ±0.1 % a, from 50 C Pt13Rh-Pt "R" DIN EN 60584-50 to +1768 C ±0.6 K or ±0.1 % a, from 100 C Pt30Rh-Pt6Rh "B" DIN EN 60584 0 to 1820 C ±0.6 K or ±0.1 % a, from 500 C a The percentages stated are relative to the temperature displayed. The larger of the two values applies. Ambient temperature influence 1-year measurement uncertainty (15 to 35 C) 300 ppm/k ±0.15 K RTD temperature probe (inputs 13 to 16) Designation Standard Measuring range Connection type Measuring accuracy a Pt100 DIN EN 60751-200 to +850 C 3/4 wire 0.05 % a The accuracy values refer to the maximum measuring range. Smaller measuring spans reduce the linearization accuracy. Ambient temperature influence Sensor line resistance Measuring current Lead compensation 50 ppm/k Max. 30 Ω per line Approx. 250 μa; not constant Not required Standard signals (inputs 13 to 16) Designation Measuring range Measuring accuracy a Input resistance or burden voltage Voltage DC 0(2) to 10 V 0.05 % > 500 kω DC 0 to 1 V 0.05 % > 100 kω Current DC 0(4) to 20 ma 0.05 % 2 V a The accuracy values refer to the maximum measuring range. Smaller measuring ranges lead to reduced linearization accuracy. Ambient temperature influence 100 ppm/k

Page 3/8 Measuring circuit monitoring In the event of a malfunction, the digitalized outputs assume defined states. Measuring probe Interfaces Display Electrical data Measuring range underflow Measuring range overflow Short-circuit (probe/ line) RTD temperature probe ++ ++ ++ ++ Thermocouple ++ ++ --- ++ Current 0 to 20 ma ++ ++ --- --- Current 4 to 20 ma ++ ++ ++ ++ Voltage 0 to 1 V ++ ++ --- --- Voltage 0 to 10 V ++ ++ --- --- Voltage 2 to 10 V ++ ++ ++ ++ ++ = is detected --- = is not detected Break (probe/line) USB host Connection USB (socket type A) Usage Exclusively for connecting a USB flash drive max.current 100 ma Ethernet Connection LAN (RJ45 socket) Usage For connecting the measuring system to a local network (for data archiving on a PC using PCC/ PCA3000 software); direct connection to PC also possible Protocols Transfer rate System bus Connection Usage Connecting cable Cable length TCP/IP, DHCP 10 Mbit/s, 100 Mbit/s Type Touchscreen TFT color screen Size 21.3 cm (8.4") Resolution 640 x 480 pixels Number of colors 256 Frame rate > 150 Hz Brightness Can be set Screen saver (shut-down) Configurable waiting period Voltage supply Power consumption Device fuse Bus out (RJ45 socket) For connecting a further measuring system (slave) Network cable (patch or crossover cable), at least CAT5 (S/FTP) Up to 100 m AC 100 to 240 V +10/-15 %, 48 to 63 Hz 39.4 W Fine wire fuse 2 5 A / 230 V slow Electrical safety Acc. to EN 61010-1 Overvoltage category II, pollution degree 2 Protection rating I

Page 4/8 Environmental influences Ambient temperature range Storage -20 to +60 C Operation -10 to +45 C Resistance to climatic conditions Relative humidity 90 % annual average without condensation (climate class 3K3 acc. to DIN EN 60721-3 with extended temperature and humidity range) Site altitude Max. 2000 m above sea level Mechanical environmental influences Classification acc. to DIN EN 60721-3-3, table 6, class 3M2 Electromagnetic compatibility (EMC) According to DIN EN 61326-1 Interference emission Class A only for industrial use Interference immunity Industrial requirements Ambient temperature range Storage -20 to +60 C Operation -10 to +45 C Resistance to climatic conditions Relative humidity 90 % annual average without condensation (climate class 3K3 acc. to DIN EN 60721-3 with extended temperature and humidity range) Site altitude Max. 2000 m above sea level Electromagnetic compatibility (EMC) According to DIN EN 61326-1 Interference emission Class A only for industrial use Interference immunity Industrial requirements Case Case type Operating position Protection type Dimensions Without trolley With trolley (handle retracted) Weight Case with removable lid (for indoor use) Any Acc. to DIN EN 60529, IP40 Approx. 467 mm x 520 mm x 225 mm Approx. 467 mm x 520 mm x 346 mm 20.5 kg

Page 5/8 Dimensions Case with removable trolley ~ 225 ~ 520 ~ 467 ~ 346 Trolley with handle extended 125 ~ 1000

Page 6/8 Galvanic isolation AC 30 V DC 50 V Analog input 1 (thermocouple) to Analog input 12 (t hermocouple) Analog input 13 (universal) to Analog input 16 (universal) AC 30 V DC 50 V AC 30 V DC 50 V AC 30 V DC 50 V AC 1500 V AC 1500 V USB (host) LAN (Ethernet) Bus Out (system bus) AC 2000 V Voltage supply (L, N) Display, operating, and connection elements (8) (7) (6) (5) (1) (2) (3) (4) (1) LAN interface (Ethernet) (2) Bus Out (system bus) (3) USB host interface (4) Mains connector incl. switch and fuse (5) Cable passage for thermal cables (6) Connecting panel (thermocouple inputs 1 to 12) 1 (7) Sockets for connecting further sensors (universal analog inputs 13 to 16) (8) Multifunction panel screen (TFT touchscreen) 1 The cover must be closed during operation.

Page 7/8 Connection diagram The connection diagram in the data sheet provides preliminary information about the connection options. For the electrical connection only use the operating manual. Knowledge of and correct technical compliance with the safety information and warnings contained in these documents are preconditions for the electrical connection, and startup as well as for safety during operation. Analog inputs Inputs 1 to 12 Only thermocouples can be connected to inputs 1 to 12. Thermocouple Symbol and terminal designation Types: See technical data + Inputs 13 to 16 RTD temperature probes (Pt100) and standard signals can be connected to inputs 13 to 16. RTD temperature probe Symbol and terminal designation - Standard signal Symbol and terminal designation Pt100, three-wire circuit B Voltage DC 0(2) to 10 V + A Ux C - B D Voltage DC 0 to 1 V + B Ux Pt100, four-wire circuit A - C B Current DC 0(4) to 20 ma + C Ix C - D D

Page 8/8 Order details (1) Basic type 987050 1 measuring system with 12 thermocouple inputs, 4 universal analog inputs, USB host interface, LAN interface, system bus interface (2) Version 8 Standard with default settings 9 Customer-specific configuration (specifications in plain text) (3) National language 1 German (default setting) 2 English (default setting) (4) Voltage supply 33 AC100to240V +10/-15%, 48to63Hz (1) (2) (3) (4) Order code / - Order example 987050 / 8 1-33 Scope of delivery 1 measuring system in the ordered version 1 operating manual 1 mains connection cable, length 3 m 1 trolley Accessories Description Part no. PCA3000/PCC JUMO software package (for evaluation of the measuring values and for creating test reports) 00431884 USB 2.0 flash drive (2 GB) a 00505592 a The USB flash drive indicated has been tested and is designed for industrial applications. No liability is assumed for other brands.