Oncor Placard Guideline (rev 01/03/2012)

Similar documents
10 Commercial, Industrial, Agricultural Services

Instructions for Completing Oncor s Interconnection Application For Solar PV Projects

Oncor Application for Interconnection of Distributed Generation

Solar Power Installation Application

City of Manhattan Beach Community Development

INTERCONNECTION REQUIREMENTS INVERTER-BASED DISTRIBUTED GENERATION SOURCES FOR SINGLE-PHASE CUSTOMER SERVICES

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power

Metering and Service Installation:

FLORIDA DEPARTMENT OF TRANSPORTATION

34.00 METERING GENERAL LABELING MULTIPLE METER ENCLOSURES ON A SINGLE PREMISE

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

S T A F F R E P O R T

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS

Document Requirements for Engineering Review PV Systems v1.0 6/9/2017

15-kV Live Terminal Primary Metering Station Pad-Mounted Outdoor

ThermoLite 110W-330W Solar Panel Installation Instructions

Existing 400A Circuit Breaker For B Secondary Chill Water Pump. Existing Single 2.5 Conduit. Reuse As Much As Practical

The Green Meter Adapter (GMA) program will become effective on January 15, Customers may start applying for a GMA on January 15, 2018.

2016 Photovoltaic Solar System Plan Review List

Electric & Gas Service Requirements (Greenbook) Overview

Commercial Electric Policy

Louisville Gas and Electric Company

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

INSTALLATION INSTRUCTIONS FOR FACTORY MUTUAL APPROVED INSTRUMENTS

Plan Check Policies and Guidelines

Transformer Protection

Installation, Maintenance, and Operation Manual

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016

Northeastern Rural Electric Membership Corporation Columbia City, Indiana

Solar*Rewards Community Engineering Frequently Asked Questions For Garden Operators Minnesota

SALEM CITY POWER ELECTRICAL REQUIREMENTS & STANDARDS MANUAL

Document Requirements for Engineering Review- PV Systems v1.1 12/6/2018

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards

SPRINGVILLE CITY ELECTRICAL REQUIREMENTS & STANDARDS MANUAL

AP-3 Electrical Termination & Mounting Configurations of UltraVolt HVPSs

Section 6 Electric Metering: Residential

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

City of Manhattan Beach Community Development

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

33'-10"± ROOF #1 (2) SUNPOWER SPR E C-AC MICROINVERTER MODULES ROOF #2 (13) SUNPOWER SPR E C-AC MICROINVERTER MODULES 78'-9"± 25'-5"

ENGINEERING SPECIFICATION

SPECIFICATIONS FOR COMMERCIAL CONSTRUCTION

Plan Check Policies and Guidelines

City of Banning Electric Utility - Residential Self Generating Facility Program (Photovoltaic Systems <48kW)

March Commercial Distributed Generation with Optional Energy Storage Systems

UNDERGROUND SERVICES - SECONDARY

Northeastern Rural Electric Membership Corporation Schedule DG-2 Columbia City, Indiana Page 1 of 5

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

PDX and PX Retrofit Series

AMENDMENT ELECTRIC SERVICE MANUAL 2014

STOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Rear EU Number Plate Sensor System User Manual SS-NP2

Interconnection Process for Generation Systems

10. METERING General Requirements

BID SPECIFICATIONS FOR (1) 300kW STANDBY GENERATOR

Service Bulletin No.: DA C , Rev.0 Date Issued: October 8, 1998 Title: Type II Fuel System/Pump Retrofit Page: 1 of 13

Noble County Rural Electric Membership Corporation

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Customer Requirements Downtown Secondary Network Service

ELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016

HARDWARE KIT INSTALLATION GLOVES

UL AND CODE COMPLIANCE

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

3.1 Overview of ATCO Electric s URD System Design

Busway Construction. Bus Bars

DISTRIBUTED RESOURCE GENERATION Feed-In-Tariff Single Phase

INSTALLATION AND OPERATING INSTRUCTIONS

Installation Instructions X-Force UTV Lift (000 Series) Capacity 2,275 lbs (1,035 kg)

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS

M100F Incremental Motor Actuator R81F Interface Board

Whether it s a harsh outdoor environment or an indoor desktop, PowerFilm has an optimal solution for your application.

REQUIREMENTS FOR PARALLEL OPERATION FOR CUSTOMERS WITH GENERATION NOT EXCEEDING 50 kw

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

For Conduit Inspections

BGE Service Application Guidelines Residential Single Projects

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

Solar PV Standard Electrical Plan

IN2 Enclosed Switches and Circuit Breakers

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility

Definitions. Scope. Customer Generation Interconnection Requirements

INTELLICHLOR SALT CHLORINATOR COMMERCIAL SYSTEM COMSYS-8 (P/N )

PRODUCT DATASHEET Laura series last update 17/9/2012

E.V.READY Specification for Installer Training Content

MILLIGAN SOLAR PROJECT

SECTION 7 VEHICLE MAINTENANCE AND CARE. Maintenance requirements General maintenance Does your vehicle need repairing?...

Requirements for Secondary Voltage Revenue Metering (750 V and less)

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Transcription:

(rev 01/03/2012) Background Information Oncor requires caution or warning placards on all distributed generation projects to alert company employees of a potential alternate source of power. Oncor placard specifications are not intended to replace any requirements in the National Electric Code (NEC). Oncor s interconnection requirements specify a manual disconnect device. This disconnect must have a visual break that is appropriate to the voltage level, be accessible to utility personnel, and capable of being locked in the open position. Oncor requests that this visible AC disconnect be located on an exterior wall and close to the Oncor meter. Placards materials are to be UV resistant and follow the same material standards as utilized in the NEC. Placards are requested to be located on the visible AC disconnect and not on the Oncor meter. Class 1 - Basic Visible AC Disconnect - Located within 10 feet of Oncor meter Examples: ON-SITE SOLAR/WIND AC SYSTEM DISCONNECT Caution Alternate Power Supply AC System Disconnect Page 1 of 5

Class 2 Visible AC Disconnect - Greater than 10 feet from Oncor meter Oncor requests the visible lockable AC disconnect be located near the Oncor meter and only under exception should it be located elsewhere. Normally the distributed generator is fed from a sub-breaker under a main breaker (located near Oncor meter). This sub-breaker can stub back out to an outside wall into a visible lockable AC disconnect by the Oncor meter and then proceed to an alternate location. Only in unusual circumstances should the visible, lockable AC disconnect be located remotely from the Oncor meter. Oncor requests proofs of placards for review with the application. Example: If Oncor meter is located on the east side of the property and the visible AC disconnect is located on the west side, then customer should provide a placard at the Oncor meter location and additionally on the AC disconnect on the west wall. ON-SITE SOLAR DISCONNECT LOCATED ON WEST WALL OF THIS STRUCTURE Page 2 of 5

Class 3 Facilities Fed from Oncor Pad Mounted Transformers Or High Voltage Delivery Facility with Remote Distributed Generation System In certain cases, distributed generation systems are installed in distant locations from the Oncor meter. This could be the case when Oncor provides a pad mounted transformer and metering at the point of common coupling (point of delivery) or where Oncor provides a high voltage point of delivery and metering. The general process for this type of installation is for two placards to be utilized. Following is an example: Solar System Disconnection Means Customer Main AC Disconnect General Layout North h Oncor Meter And Equipment Address: street address, City ON-SITE PHOTOVOTAIC SEE MAP FOR LOCATION OF MAIN AC DISCONNECT Page 3 of 5

Class 3 (Continued) Site Map Details The basic elements of the site map should include the following: 1) Location of the Oncor meter and Oncor delivery equipment, 2) Location of the generators main AC disconnect, 3) Facility address, 4) North indicator and basic street and building layout, 5) Map title example, Solar System Disconnecting Means. Process Information Location of Placards The intent of this process is to provide a warning to the Oncor operations group of a potential alternate source of power and give individuals the opportunity to clear or open any disconnects when work is being done at the Oncor or customer delivery equipment. Oncor requests that identical placards be installed on the customer s main equipment to provide additional recognition. In most cases on high voltage installations, safety precautions utilizing visual opens and grounding will be implemented. Placard solutions for this class of installation are unique and alternate solutions can be proposed and coordinated with Oncor. For this type of installation Oncor requests: 1) Oncor requests proofs of placards for review with the application, 2) Upon approval, three sets of the Site Map and Caution placard are requested; one for installation on existing Oncor equipment, another for future use should Oncor equipment be replaced, and the a third set to be installed on the customers main equipment, 3) Oncor requests that the contractor furnish Oncor the placards and adhesive tape, 4) Oncor s operations group will want to mount the placards on the Oncor equipment, 5) Oncor s operation group will need to approve and communicate the acceptance of the placard installation to the Oncor Distribution Specialist after a site visit to the facility. Page 4 of 5

Class 3 (Continued) Installations Utilizing Oncor Pad Mounted Transformers In addition to the above requirements, Oncor also requests an additional placard. This placard is a caution placard with two pre-drilled holes to attach to the secondary cables inside the Oncor transformer (or Oncor point of delivery equipment). The thought here is if the transformer is ever removed and replaced this placard would remain and provide a warning to Oncor personnel. Drilled holes ON-SITE PHOTOVOTAIC Placard Materials Customers may use color cast acrylic placards. Oncor also accepts placards on sticker type material if outdoor-rated and of similar specifications as required in the National Electric Code (NEC). Both must have an UV inhibitor rated for exterior use. If color cast acrylic is utilized, customer must also provide to the operating technician adhesive tape. A preferred brand is 3M Scotch, VHB FAMILY, found on page 3 of the 3M VHB Tapes Svc Bulletin- Foam tapes 4956, 4941, 4936 or 4926. This VHB tape should be minimum 1 inch wide, be double sided adhesive tape with VHB (Very High Bond) adhesive for exterior applications. Page 5 of 5