Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

Installation Instructions

Installation Instructions

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS

Supplemental Installation Instructions -- August 2016

Installation Instructions

Installation Instructions

Supplemental Installation Instructions -- August 2016

Installation Instructions

Installation Instructions

Installation Instructions

Electrical Data Supplement

Electrical Data Supplement

INSTALLATION INSTRUCTIONS DNLOWAMB015A00, DNLOWAMB016A00

Installation Instructions

Electrical Data Supplement

Installation Instructions

- Wiring Brochure tekmarnet 4 Thermostat 545

Electrical Data Supplement

Installation Instructions

INSTALLATION INSTRUCTIONS APARTMENT FAN COIL UNIT FMC4X, FMC4Z

Wiring Diagrams (Including Accessories) (50/60 Hz)

Installation Instructions

Installation Instructions

WIRING DIAGRAMS FB4C FE4A/FE5A FH4C FV4C FX4D FY5B PF4MA PF4MB LABEL

CAUTION. SMALL ROOFTOP UNITS ACCESSORY ELECTRIC HEATER AND SINGLE POINT BOX ELECTRIC COOLING AND HEAT PUMP 3to15TONS TABLE OF CONTENTS !

Installation Instructions

DP13CM. Packaged Air Conditioner 3, 4, & 5 Tons / 13 SEER. Cooling Capacity: 36,000-56,000 BTU/h

Installation Instructions

DZ11S Commercial & 10-Ton, Three-Phase

DP14HM Commercial 3-5 TON THREE-PHASE PACKAGED HEAT PUMPS 14 SEER. Cooling Capacity: 34,400-58,000 BTU/h Heating Capacity: 33,200-57,000 BTU/h

Owner s Information Manual

Installation Instructions

GPC13M COMMERCIAL PRODUCT SPECIFICATIONS 13 SEER PACKAGED AIR CONDITIONER 3- TO 5-TON COOLING CAPACITY 35,000-56,000 BTU/H

Installation Instructions

This parts list is current as of the above revision date. See for the current revision.

Installation Instructions

ALWAYS SAVE THIS BOOK FOR FURE REFERENCE.

GPC13M R-410A, 13 SEER. Packaged Air Conditioner. 3, 4, & 5 Tons. Cooling Capacity: 36,000-56,000 BTU/h

DZ11TA Commercial. 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/ IEER /3.3 COP/R-410A

REPAIR PART INSTALLATION INSTRUCTIONS

Installation Instructions Part Numbers: CRLOWAMB018A00 THROUGH CRLOWAMB026A00

MPSH03CG-H05CG(D)

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls

Installation Instructions

INSTALLATION, START-UP AND SERVICE INSTRUCTIONS

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up

IMPORTANT ATTENTION INSTALLERS:

Installation Instructions

Installation Instructions

Wiring Diagrams DIAGRAM INDEX

Installation Instructions

INSTALLATION INSTRUCTIONS

FAST-STAT. Model 3000 Installation Instructions. Application. Troubleshooting not operating. Before Installing This Product. Sender Installation

Installation Instructions

Installation and Start-Up Instructions

Installation Instructions

Package Unit Modulating Economizer Installation Instructions

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

- Wiring Brochure Universal Reset Module 422

Installation Instructions

Installation Instructions

- Wiring Brochure Universal Reset Module 422e

Installation instructions for KIT15017, KIT15018, KIT15019, and KIT15020

INSTALLATION INSTRUCTIONS CMH-7A LOW AMBIENT CONTROL

LIGHT COMMERCIAL - 3 HP ECM MOTOR / CONTROLLER HIGH STATIC DRIVE KITS

INSTALLATION INSTRUCTION

TECHNICAL SUPPORT MANUAL Split System Air Conditioner H4A3, 3 Phase

Installation Instructions

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: AHP18 THRU 60 AND SHP48 THRU 60 FEATURES

Installation and Start Up Instructions

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

TECHNICAL SUPPORT MANUAL Split System Heat Pump R2HM, R2H3, WCH3**2

INSTALLATION INSTRUCTIONS CMH-21 Low Ambient 460V Fan Speed Control

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS PARTS LIST INSTALLATION INSTRUCTIONS AIR CONTROL KIT (800A0168 OR 800A0169)

TECHNICAL SUPPORT MANUAL Fan Coils FSM4X6000AT

WIRING DIAGRAMS FA4C FY4A FC4D FX4C FH4C

TECHNICAL SUPPORT MANUAL Coils for Manufactured Housing EMA2X, EMA4X

Installation Instructions

Transcription:

PLOWAMB001A00 SMALL ROOFTOP UNITS GAS HEAT/ELETRI OOLING, ELETRI OOLING AND HEAT PUMP UNITS AESSORY MOTORMASTERR II HEAD PRESSURE ONTROLLER 60Hz 3to12---1/2tons Installation Instructions IMPORTANT: Read these instructions completely before attempting to install this accessory. PAKAGE ONTENTS ITEM QTY ONTENTS AL56AU216 4 Screws 10B--- 16 x ½ LG 50DK402769 1 onductive Grease AU27AS131 2 Lockwashers, #10 50HS500288 1 Bracket IIK --- PLOWAMB --- 06 1 Instructions SAFETY ONSIDERATIONS Installation, start -up and servicing of this equipment can be hazardous due to system pressures, electrical components and equipment location (roofs, elevated structures, etc.) Untrained personnel can perform the basic maintenance functions. All other operations should be performed by trained service personnel. When working on air-conditioning equipment, observe precautions in the literature, tags and labels attached to the unit, and other safety precautions that may apply. Follow all safety codes. Wear safety glasses and work gloves. Recognize safety information. This is the safety-alert symbol. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and AUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard which could result in personal injury or death. AUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.! WARNING ELETRIAL SHOK HAZARD Failure to follow this warning could cause personal injury or death. Before performing service or maintenance operations on unit, turn off main power switch to unit and install lockout tag. Ensure electrical service to rooftop unit agrees with voltage and amperage listed on the unit rating plate.! WARNING ELETRIAL SHOK HAZARD Failure to follow this warning could result in personal injury or death. Open all remote disconnects and install lockout tag(s) before servicing this equipment. INTRODUTION The Motormaster II head pressure controller is a cycle control device activated by a temperature sensor mounted on a header tube of the outdoor coil. (See Fig. 1.) It is designed to cycle the outdoor-fan motors on or off to maintain the saturated condensing temperature within normal operating limits of approximately 130_ to 110_F high, 70_ to 50_F low. The controller maintains working head pressure at low ambient temperatures down to 0_F. The controller is activated by a temperature sensor and is for use with 60 Hz units only. The controller can be used with both single-phase and 3-phase units. NOTE: This accessory requires Winter Start package. opyright 2011 A / BDP D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 12/11 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. atalog No:IIK---PLOWAMB---06 Replaces: IIK ---PLOWAMB ---04

Fig. 1 - Motormaster II ontroller 08282 1. Disconnect power to unit, install lockout tag. 2. Disconnect outdoor-fan motor (OFM) wires at the contactor. 3. Remove OFM wires from unit control box. 4. Mount Motormaster II controller on unit. Refer to Fig. 2. NOTE: The controller must be mounted vertically with the leads at the bottom. Using the template supplied on the last page in this book, drill mounting holes. To ensure electrical ground, insert star washers (supplied with the controller) under the heads of mounting screws. 5. Determine sensor location by referring to Fig. 3-12. Route sensor wire through bottom of Motormaster II controller (Fig. 13) to sensor location specified. Prior to installation, apply conductive grease supplied with accessory to contact surface of sensor.! AUTION EQUIPMENT DAMAGE HAZARD Failure to follow this caution may result in damage to equipment. Sensor assembly is delicate. Handle with care. 6. Attach sensor to top half of header tube as shown in Fig. 14. Installed sensor must be left uninsulated. 7. Power wiring must comply with all local and National Electrical ode (NE) requirements. Refer to Fig. 15-18 for power wiring connections. oil up all excess wire and secure it next to the controller. 8. The transformer is factory wired for 460-v operation. It must be rewired for 208/230-v use. Remove the black wire from L2 to 460-v black and connect red wire (208 v) or orange wire (230 v) to L2 for desired operation. Install wire nuts over wires not in use. NOTE: Refer to Fig. 19 for thermistor resistance vs temperature. 9. Wind baffles are required to prevent wind crosscurrents from causing abnormally low condensing temperatures. Wind baffle fabrication details are described in Fig. 20 and 21. 10. Reconnect power to the unit. The Motormaster II head pressure controller is equipped with an alternate operating mode. When this mode is selected, the controller shifts the fan cycle sequence to effectively raise the average condensing temperature approximately 20_F higher than the standard operating mode. In this alternate mode, the outdoor fan begins cycling at higher outdoor ambient temperatures. This mode should only be used if the evaporator coil shows signs of frosting at low outdoor ambient temperatures. To select the alternate operating mode, move the jumper wire on the Motormaster II control board from terminal T1 to terminal T2. 2

ONDENSER OIL MOTORMASTER II BULKHEAD OMPRESSORS MOTORMASTER II ONTROLLER SINGLE POINT BOX 50T04-07; RAS036-072; 558J04-07 10715 50T08-12; RAS090-121; 558J08-12 10716 UNITS WITHOUT SINGLE POINT BOX UNITS WITH SINGLE POINT BOX MOTORMASTER II II MOTORMASTER II 48T04-07; RGS036-072; 580J04-07 UNITS WITHOUT SINGLE POINT BOX 10718 50T04-07; RAS036-072; 558J04-07 UNITS WITH SINGLE POINT BOX 10717 ONDENSER OIL MOTORMASTER II ONTROLLER BULKHEAD MOTORMASTER II OMPRESSORS 10719 50T08-12; RAS090-121; 558J08-12 UNITS WITHOUT SINGLE POINT BOX 10720 48T08-12; RGS090-121; 580J08-12 UNITS WITH SINGLE POINT BOX Fig. 2 - Motormaster II ontroller Location 3

48/50T04; RGS/RAS036; 580J/558J04 08615 Fig. 3 - MotormasterR II Sensor Locations - 3 Ton ooling Units 48/50T05 and 06; RGS/RAS048 and 060; 580J/558J05 and 06 08260 Fig. 4 - MotormasterR II Sensor Locations - 4 and 5 Ton ooling Units 4

48/50T07; RGS/RAS072; 580J/558J07 08261 Fig. 5 - MotormasterR II Sensor Locations - 6 Ton ooling Units 48/50T08; RGS/RAS090, 091; 580J/558J08 08616 Fig. 6 - MotormasterR II Sensor Locations - 7-1/2 Ton ooling Units 5

48/50T09 and 12; RGS/RAS101, 102, 120, 121; 580J/558J09 and 12 08617 Fig. 7 - MotormasterR II Sensor Locations - 8-1/2 and 10 Ton ooling Units Sensor Location 09493 50TQ04; RHS036; 548J04 Fig. 8 - MotormasterR II Sensor Locations - 3 Ton Heat Pump Units 6

Sensor Location 50TQ05; RHS048; 548J05 09494 Fig. 9 - MotormasterR II Sensor Locations - 4 Ton Heat Pump Units Sensor Location 09495 50TQ06; RHS060; 548J06 Fig. 10 - MotormasterR II Sensor Locations - 5 Ton Heat Pump Units 7

Sensor Location 50TQ07; RHS072; 548J07 09496 Fig. 11 - MotormasterR II Sensor Locations - 6 Ton Heat Pump Units Sensor Location 50TQ08 and 09; RHS090, 102; 548J08 and 09 09497 Fig. 12 - MotormasterR II Sensor Locations - 7-1/2 and 8-1/2 Ton Heat Pump Units 8

SENSOR INTEGRAL WIRE TIE 3/8 HEADER TUBE ONDUTIVE GREASE NOTE: INSTALLED SENSOR MUST BE LEFT UNINSULATED. Fig. 14 - Sensor onnection Details 09559 Fig. 13 - MotormasterR II ontroller Interior 00102 OUTDOOR-FAN MOTOR 1 PHASE UNITS 3 PHASE UNITS UNIT ONTROL BOX 11 21 23 23 UNIT ONTROL BOX 11 21 13 23 BLU AP1 WHT ONTATOR ONTATOR BLU THESE WIRES RELOATED FROM BASE UNIT MOTORMASTER II ONTROL BOX SEE NOTE ORG RED 460 230 200 L2 T2 L1 T1 TRAN A 24 RED GRN- R LOGI BOARD W1 1 ORG 2 LEGEND - ompressor ontactor - Outdoor Fan ontactor TRAN - Transformer NOTE: Motomaster II trasnformer is wired for 460-v supply. It must be rewired 208/230-v application. Be sure to insulate unused tap. Refer to color code. T2 T1 S2 S1 RELOATE JUMPER TO TERMINAL T2 FOR ALTERNATE OPERATION ONTROL THERMISTOR Fig. 15 - Wiring Schematic, 3 to 6 Ton Electric ooling Units (48/50T04-07; RGS/RAS036-072; 580J/558J04-07) 10547 9

3 PHASE UNITS DEFROST BOARD DF2 OF 13 23 AP1 OUTDOOR-FAN MOTOR 1 PHASE UNITS DEFROST BOARD DF2 OF 23 23 ONTATOR BLU BLU THESE WIRES RELOATED FROM BASE UNIT ONTATOR MOTORMASTER II ONTROL BOX SEE NOTE ORG RED 460 230 200 L2 T2 L1 T1 TRAN A 24 RED GRN- 1 2 W1 R LOGI BOARD ORG OM W1 T2 T1 RELOATE JUMPER TO TERMINAL T2 FOR ALTERNATE OPERATION S2 S1 HEAT PUMP RELAY FIELD SUPPLIED (HN61KJ250 ONTROL THERMISTOR UNIT LOW VOLTAGE THERMOSTAT ONNETION BOARD LEGEND - ompressor ontactor - Outdoor Fan ontactor TRAN - Transformer NOTE: Motomaster II trasnformer is wired for 460-v supply. It must be rewired 208/230-v application. Be sure to insulate unused tap. Refer to color code. Fig. 16 - Wiring Schematic, 3 to 6 Ton Heat Pump Units 10548 10

Legacy UNIT ONTROL BOX 1 3 4 5 BLU MOTOR 1 MOTOR 2 MOTORMASTER II ONTROL BOX SEE NOTE ORG RED 460 230 200 L2 T2 L1 T1 F DUAL APAITOR H TRAN A 24 RED GRN- 1 2 R LOGI BOARD ORG W1 T2 T1 S2 S1 RELOATE JUMPER TO TERMINAL T2 FOR ALTERNATE OPERATION ONTROL THERMISTOR LEGEND - ompressor ontactor - Outdoor Fan ontactor TRAN - Transformer NOTE: Motomaster II trasnformer is wired for 460-v supply. It must be rewired for either 208 or 230-v application. Be sure to insulate unused tap. Refer to color code. Fig. 17 - Wiring Schematic, Dual Fan Motor, 7-1/2 to 12-1/2 Ton Electric ooling Units (48/50T08-12; RGS090-121; 580J/558J08-12) 10549 11

4 4 2 5 MOTOR 1 MOTOR 2 HEAT PUMP MOTORMASTER II ONTROL BOX SEE NOTE ORG RED 460 230 200 L2 T2 L1 T1 F DUAL APAITOR H TRAN A 24 RED GRN- 1 2 R W1 R LOGI BOARD ORG OM W1 T2 T1 RELOATE JUMPER TO TERMINAL T2 FOR ALTERNATE OPERATION S2 S1 HEAT PUMP RELAY FIELD SUPPLIED (HN61KJ250 ONTROL THERMISTOR UNIT LOW VOLTAGE THERMOSTAT ONNETION BOARD LEGEND - ompressor ontactor - Outdoor Fan ontactor TRAN - Transformer NOTE: Motomaster II trasnformer is wired for 460-v supply. It must be rewired for either 208 or 230-v application. Be sure to insulate unused tap. Refer to color code. Fig. 18 - Wiring Schematic, 7-1/2 to 8-1/2 Ton Heat Pump Units 10550 12

Fig. 19 - Thermistor Resistance vs Temperature 10551 13

B A G H E F D 9/32 DRILL (BOTH SIDES OF BAFFLE) 10 MIN (254) 1 MIN (26) SIDE BAFFLE FRONT BAFFLE Fig. 20 - Wind Baffles - 3 to 6 Ton Units 48/50T, RGS, RHS, 580/558J, 50TQ, 548J 08601 UNIT 48/50T RGS/RAS 580J 558J SIZE 04, 036 05, 048 06, 060 07, 072 25 (635.0) 28 5 /8 (727.1) 28 5/ 8 (727.1) 28 5 / 8 (727.1) DIMENSIONS FRONT BAFFLE INHES (mm) A B D E F G H J 25 1/ 2 26 27 1/4 4 1/4 N/A (647.7) (660.4) 29 1/8 (739.8) 29 1/8 (739.8) 29 1/8 (739.8) 29 5/8 (752.5) 29 5/8 (752.5) 29 5/8 (752.5) 27 1/4 27 1/4 35 3/8 (904.9) 4 1/4 4 1/4 4 1/4 N/A N/A 32 1/4 (819.2) UNIT 48/50T RGS/RAS 580J 558J SIZE 04, 036 05, 048 06, 060 07, 072 SIDE BAFFLE INHES (mm) A B D E F G H J 21 3/8 21 7/8 27 1/4 4 1/4 N/A (549.3) (555.6) 20 7/8 (530.2) 20 7/8 (530.2) 20 7/8 (530.2) 20 7/8 (530.2) 21 3/8 (549.3) 21 3/8 (549.3) 21 3/8 (549.3) 21 7/8 (555.6) 21 7/8 (555.6) 21 7/8 (555.6) 27 1/4 27 1/4 35 3/8 (904.9) 4 1/4 4 1/4 4 1/4 N/A N/A 32 1/4 (819.2) BAK BAFFLE INHES (mm) UNIT SIZE A B D E F G H J K 04, 036 N/A N/A N/A N/A N/A N/A N/A N/A 05, 048 N/A N/A N/A N/A N/A N/A N/A N/A 06, 060 N/A N/A N/A N/A N/A N/A N/A N/A 50TQ RHS 548J 07, 072 20 7/8 (530.2) 21 3/8 (549.3) 21 7/8 (555.6) 35 3/8 (904.9) 41/4 LEFT BAFFLE (mm) UNIT SIZE A B D E F G H J K 25 25 1/2 26 27 1/4 41/4 04, 036 (635.0) (647.7) (660.4) (692.2) 28 5/8 29 1/8 29 5/8 27 1/4 41/4 50TQ 05, 048 (727.1) (739.8) (752.5) (692.2) RHS 25 25 1/2 26 35 3/8 41/4 32 1/4 548J 06, 060 (635.0) (647.7) (660.4) (904.9) (819.2) 28 5/8 29 1/8 29 5/8 35 3/8 41/4 32 1/4 07,072 (727.1) (739.8) (752.5) (904.9) (819.2) Table 1 Wind Baffle Details - 3 to 6 Ton Unit 14

B A K D J H G F E 9/32 DRILL (BOTH SIDES OF BAFFLE) SIDE BAFFLE FRONT BAFFLE 10 MIN (254) 1 MIN (26) Fig. 21 - Wind Baffles - 7.5 to 12.5 Ton Units 48/50T, RGS, RHS, 580/558J, 50TQ, 548J 08602 UNIT 48/50T RGS/RAS 580J 558J SIZE 08, 090, 091 09, 101, 102 12, 120, 121 FRONT BAFFLE INHES (mm) A B D E F G H J K 41 1/8 41 5/8 35 3/8 1 1/4 9 1/4 17 1/4 33 1/4 N/A (1044.6) (1057.3) (904.9) (31.8) (235.0) (438.2) (844.6) 40 5/8 (1031.9) 28 5/8 (727.1) 40 5/8 (1031.9) 29 1/8 (739.8) 41 1/8 (1044.6) 29 5/8 (752.5) 41 5/8 (1057.3) 43 3/8 (1108.1) 43 3/8 (1108.1) 1 1/4 (31.8) 1 1/4 (31.8) 9 1/4 (235.0) 9 1/4 (235.0) 17 1/4 (438.2) 17 1/4 (438.2) 33 1/4 (844.6) 33 1/4 (844.6) 41 1/4 (1047.8) 41 1/4 (1047.8) UNIT 48/50T RGS/RAS 580J 558J SIZE 08,090, 091 09, 101, 102 12, 120, 121 SIDE BAFFLE INHES (mm) A B D E F G H J K 41 3/8 41 7/8 35 3/8 4 1/4 32 1/4 N/A (1057.3) (1063.6) (904.9) (819.2) 40 7/8 (1038.2) 40 7/8 (1038.2) 40 7/8 (1038.2) 41 3/8 (1057.3) 41 3/8 (1057.3) 41 7/8 (1063.6) 41 7/8 (1063.6) 43 3/8 (1108.1) 43 3/8 (1108.1) 4 1/4 4 1/4 32 1/4 (819.2) 32 1/4 (819.2) 39 3/16 (995.4) 39 3/16 (995.4) BAK BAFFLE INHES (mm) UNIT SIZE A B D E F G H J K 08,090, 40 7/8 41 3/8 41 7/8 43 3/8 41/4 32 1/4 091 (1038.2) (1057.3) (1063.6) (1108.1) (819.2) 50TQ RHS 548J 09, 101, 102 12, 120, 121 40 7/8 (1038.2) 40 7/8 (1038.2) 41 3/8 (1057.3) 41 3/8 (1057.3) 41 7/8 (1063.6) 41 7/8 (1063.6) 43 3/8 (1108.1) 43 3/8 (1108.1) 41/4 41/4 32 1/4 (819.2) 32 1/4 (819.2) 39 3/16 (995.4) 39 3/16 (995.4) 39 3/16 (995.4) LEFT BAFFLE INHES (mm) UNIT SIZE A B D E F G H J K 08, 090, 40 5/8 41 1/8 41 5/8 43 3/8 11/4 91/4 17 1/4 33 1/4 41 1/4 091 (1031.9) (1044.6) (1057.3) (1108.1) (31.8) (235.0) (438.2) (844.6) (1047.8) 50TQ 09, 101, 40 5/8 41 1/8 41 5/8 43 3/8 11/4 91/4 17 1/4 33 1/4 41 1/4 RHS 102 (1031.9) (1044.6) (1057.3) (1108.1) (31.8) (235.0) (438.2) (844.6) (1047.8) 548J 12, 120, 121 40 5/8 (1031.9) 41 1/8 (1044.6) 41 5/8 (1057.3) 43 3/8 (1108.1) 11/4 (31.8) 91/4 (235.0) 17 1/4 (438.2) 33 1/4 (844.6) 41 1/4 (1047.8) Table 3 Wind Baffle Details - 7.5 to 12.5 Ton Units (ontinued) 15

MOUNTING TEMPLATE 5-3/8-in. REF [136.5] DRILL 9/64-in. [3.6] DIAMETER HOLE TOP UT ALONG SOLID BORDER LINES TO REMOVE TEMPLATE TEMPLATE FOR MOTORMASTER II 9-in. REF [228.6] NOTE: Dimensions in [ ] are in millimeters NOTE: Verify before using. Drawing may not be to scale. 5-in. [127] DRILL 9/64-in. [3.6] DIAMETER HOLE 2-3/8-in. REF [60.3] 1-1/8-in. REF [28.6] A11576 16