Installation Instructions for direct line voltage connection / Basic / SubstiTUBE Value Advanced ST8-HV / ST8-HB / ST8-HA

Similar documents
Application Note SubstiTUBE ST8-SD4

SubstiTUBE Advanced ST8-HA4

SubstiTUBE Value EM T8 (AUS Fighter Tube) ST8V-0.6M ST8V-1.2M ST8V-1.5M

Datasheet. OSRAM SubstiTUBE Trio 2

ST8V-EM 19 W/ mm EM

INOTube The LED conversion kit for INOTEC emergency exit luminaires

ST8V 21.5 W/ mm EM

LED T8 BP. GE Lighting. Tubular lamps DATA SHEET. Specification Features. Product information. Applications. IEC standards

ESLED4, ESLED5 Instructions

OSRAM DULUX L LUMILUX CFLni, with 4-pin 2G11 base for ECG/CCG operation

3NP1 Fuse Switch Disconnectors up to 630 A

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers:

Typ. CRI. SDCM Module P [W]

General notes. Operating conditions

ELEMENT. Product family datasheet. Constant Voltage Non dimmable

QTi DALI 1X36/ DIM

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Appendix: Safety and application notes for... 15

TECTONIC LED CORP. ISO

QTi 2X28/54/35/49 GII

LED light is a new dimension Discover the premium quality LED lamps by OSRAM for multifaceted applications

Instruction/Installation Manual

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

For Info: Phone: Fax:

Miniature Circuit-Breakers (MCBs)

1 Safety instructions

PrevaLED Linear HV Ideal alternative to linear fluorescent lamp source Basic description

PrevaLED Linear Slim 3

PrevaLED Linear Value 2

LED T8 glass tube 4ft 18W

PrevaLED Linear Slim 3

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

OSRAM DULUX L LUMILUX

LED T8 Full Glass Tube

Emergency lighting units PC COMBO

MINI MCR-SL-UI-UI(-SP)(-NC)

QTP-M 2X Product datasheet. QUICKTRONIC-M ECG for circular FL 16 mm

10 Load and Motor Switchgear

FLUDEX - thermal switching equipment. Operating instructions BA en 04/2012. FLENDER couplings

Thermal Overload Relays

Solid State T8 tube is the smart alternative to a

Installation manual portable distributors

DeltaSol AX * *

SEMITOP2,3,4 Press-Fit

LV Capacitor CLMD03 Power Module Instruction manual

SIMOBREAKER The New Substation with Rotary Disconnector Fully Assembled, Compact and with High Availability

3. Operating instructions: Minor 200

Safety Switches Series 8537

LED.Commercial 12W LED DD

LDLS Self-Ballasted Linear Detachable Light System User s Manual

POWERSTAR HQI -T W Metal halide lamps with quartz technology for enclosed luminaires

User Manual Rittal PMC UPS 6kVA

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. System Universal LED dimming insert Standard

NH-Fuse system Low voltage

KeContact P20. User manual

LED Recessed Troffer Retrofit Kit

Appendix: Safety and application notes for 19

Contents. 1 Introduction. 2. Advisory and Information Systems. 3. Supply. 3.1 Quality of Electric Supply. 3.2 Interference with other Customers

OPERATIONS MANUAL CR Thermoreactor

GTB Working Group Light Sources

Installation manual wall-mounted distributor

PIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution

ISO 91:2017 Consulting Paper. Guidance for QuantityWare BCP Implementations

1 Safety instructions. 2 Device components. Light Management LED touch dimmer insert. Art. No LEDDE. Operating instructions

Manual. Industrial Controls. Protection Devices. SIRIUS 3RV Motor Starter Protectors. Edition 12/2017. siemens.com

LUMILUX T5 HO CONSTANT

INDUSTRIAL POWER SUPPLIES SFL-SERIES

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

28W WORK LAMP Model: CTL28 Part No:

Emergency lighting units EM Inverter

MODVAR Low voltage reactive power compensation modules Installation manual

UL AND CODE COMPLIANCE

SCOPELITE TIMING LIGHT OPERATING MANUAL

Usage Instructions of Solar Control for 3Way-Ball Valve

Lampholders. Lampholders for halogen lamps - TECHNICAL CHARACTERISTICS. Conformity to Standards EN Standard

ASZ... Potentiometers. Building Technologies Division. ASZxx.3x

PrevaLED Cube G2. Product family datasheet. Spot-, Down- and Wallmount Light Engines and Modules

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

RENEWAL PARTS Supersedes: RP4 (1012) Form RP4 (813)

Miniature Circuit-Breakers (MCBs)

Implementation procedure for certification and continued airworthiness of Beriev Be-200E and Be-200ES-E

Isolating transformer DS0107. Three-phase isolating transformers for the supply of three-phase loads in medical locations

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

Operating manual UPS - System

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

Display and signal lamps for traffic light installation.

HyperFlex 12G.

BETA Switching Switching Devices

Emergency lighting units PC COMBO

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle


Reliability with the most essential intellect. Philips HF-Essential Electronic ballasts for TL5 lamps

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Transcription:

www.osram.com/substitube Installation Instructions for retrofitting a and direct line voltage connection Value Advanced ST8-HV / ST8-HB / ST8-HA / Basic /

1. Installation options 1. Installation options Which configuration fits to what kind of? Which setup leads to which advantages and disadvantages? Described below are the possible options. Please refer to the following chapters for more details, product related details and technical datasheets can be downloaded at www.osram.com/substitube 1.1 Overview Retrofitting a accord. IEC 62776 Draft - Very easy and safe installation of - The can still be used for fluorescent lamps when the normal starter is reinstalled. The certification of the remains valid. - Losses of are significantly reduced to usually ~1W Direct wiring - Rewiring of necessary! In stallation must be done by qualified Electricians only and all security precautions described herein must be followed - Responsibility of technical and safety consequences of the converted is shifted to the party carrying out the conversion. - Conformity with all applicable legal requirements must be assured for the rewired and compliance with all relevant safety requirements and other technical standards (e.g. acc. to DIN VDE 0701-0702) must be established - The converted must be given a new type plate. - The converted must not be ope erated with fluorescent lamps after rewiring. - The installer becomes the legal responsible for the converted. Please refer to chapter 3.1 Direct wiring for more details. ECG Retrofitting a Direct wiring Overview of possible installations Installation Instructions 15.03.2014 Page 2

2. Retrofitting 2. Retrofitting in a Exchanging the starter and replacing the lamp is all what needs to be done to upgrade an existing with conventional control gear to newest OSRAM LED-technology. The fluorescent lamp has to be exchanged with and the starter being replaced by Start. The built-in can be used as it is and existing certifications remain valid. Its losses are reduced to ohmic losses of usually about 1W. If the starter has not been changed to Start the will start blinking. Please switch off immediately and change the starter, because can be damaged. can be used in s with changeable starter only. Existing power factor compensation capacitors worsen the power factor, but may remain within the. Furthermore, it should be taken into consideration the maximum amount of SubstiTUBE connected to one circuit breaker according technical datasheet. In case a conventional fluorescent lamp is being inserted when the SubstiTUBE Start is in place, the lamp ends will gleam, but the lamp will not be destroyed. Start p.f. corretion capacitor Circuit diagram of a retrofitted Retrofitting for common lamp holders Installation Instructions Make sure that the supply voltage is disconnected Remove the conventional lamp Replace the old starter with Start Insert into lamp holders and check the light distribution angle Start (with fuse 250V, T2A) necessary for operation and safety Duo circuit double lamp s can be refitted analogue to single lamp s. p.f. corretion capacitor Start Start Circuit diagram of a retrofitted double lamp Installation Instructions 15.03.2014 Page 3

3. Direct Wiring 3. Direct line voltage connection If an ECG is retrofitted or the losses of s should be eliminated, the must be rewired, as described below in 3.1 Direct wiring. Analogue proceeding is recommended for new s. Luminaires may only be adapted to accept conversion lamps by appropriately trained personnel. Conversion of the shifts the responsibility for the technical and the safety consequences of the conversion to the party carrying out the conversion; this person becomes the legal responsible for the new product. 3.1 Direct wiring It is recommended to rewire a on both sides as shown below. Thus can be inserted in any direction with standardized IEC compliant G13 lamp holders. All wires need to be approved for the existing voltages and appliance class. Usually solid wires with single isolation can be used for class I, double insulation wires could be used for class II. The maximum wire cross- section for lamp holders and starters is typically 0.5mm 2. Built-in control gears must not remain connected after rewiring. Start or fuse Direct wiring circuit diagram of a retrofitted Installation instructions Rework by qualified electricians only Make sure that the supply voltage is disconnected Remove the conventional lamp Remove power factor correction capacitor (if installed) to improve power factor Rewire the as shown in the circuit diagram above Use Start or a fuse (250V, T2A) Insert SubstiTUBE into lamp holders and check the light distribution angle Assure that the rewired conforms with all applicable legal requirements and establish that it complies with all relevant safety requirements and other technical standards (e.g. acc. to DIN VDE 0701-0702) Mark rewired with new type plate Start or fuse (250V, T2A) is necessary for installation protection Do not insert fluorescent lamps, as the y would be destroyed Double lamp s can be refitted analogue to single lamp s. The s are to be wired as shown below. Start or fuse Direct wiring circuit diagram of a retrofitted double lamp Installation Instructions 15.03.2014 Page 4

3 Direct Wiring 3. 3.1.1 Sample Direct wiring of a for SubstiTUBE E (control gear removed). installation direct wiring G13 lamp holder L, N connection to terminal SubstiTUBE Start Make sure to modify the wiring completely, y, otherwise e.g. short circuits could lead to damage. Installation Instructions SubstiTUBE 15.03.2014 Page 5