Process Valve/Series VN

Similar documents
Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

Exclusively for air pressure system and air-hydro circuit control

Process Valve/Series VN

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

High Pressure Coolant Valve

Coolant Valve. Air Operated/External Pilot Solenoid

A variety of circuits in simple construction Intermediate and emergency stops with a large size cylinder

Proper selection of body and sealing materials permits application of a wide variety of fluids.

Coolant Valve. VNC Series. Cylinder actuation by pilot air

Rubber Seal VP300/500/700

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Series AV2000/3000/4000/5000

Soft Start-up Valve. AV2000/3000/4000/5000 Series

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

3 Port Solenoid Valve Direct Operated Poppet Type

2 Port Solenoid Valve For Dust Collector

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

Steam Valve. Series VND. 2 Port Valve for Steam. With indicator (Option) By adopting of PTFE seal, the valve is suited for steam.

Series VP3145/3165/3185

NAMUR Interface 5 Port Solenoid Valve

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication

VNA VNB SGC SGH VNC VNH VND VCC

Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type

3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application.

5 Port Solenoid Valve

Series VP3145/3165/3185

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

Series VXR21/22/23. Water Hammer Relief, Pilot Operated 2 Port Solenoid Valve. For Water and Oil

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Symbol. Single DS 2120 R2 P R1. How To Order. Body Type 2 : Body Ported Type. Body Option O : Standard

Pilot Operated 2 Port Solenoid Valve for Dry Air

Compact Proportional Solenoid Valve

2/3 Port Valve for Various Fluids Control

3 Port Solenoid Valve

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Rubber Seal 5 Port Pilot Type/Body Ported Type. Symbol. How to Order

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating,

Pilot Operated 2 Port Solenoid Valve for Dry Air

5 Port Pilot Solenoid Valve Metal Seal. Configuration Voltage Electrical entry Option. Standard. 100V AC50/60Hz 200V AC50/60Hz 24V DC.

Series VVXA21/22. Direct Air Operated 2 Port Valve/Manifold For Air, Gas, Vacuum and Oil VC VDW VQ VX2 VX VX3 VXA VN LVC LVA LVH LVD LVQ LQ LVN PA PAX

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

Pilot Operated/Zero Pressure Differential Operation

CVE2/CVSE2 CVE3/CVSE3

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. 3 (Closed center) 3/4, 1 3 (Exhaust center)

25% reduction in volume * PB1013A/Air-operated type without foot

Direct Air Operated 2 Port Valve/Manifold For Air, Gas, Vacuum and Oil

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Transmitters: Relay Valve VR4151/4152

5 Port Pilot Solenoid Valve Rubber Seal

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

1 1/4 (32A) to 2 (50A) added.

ISO Standard Solenoid Valve/SIZEq Rubber Seal Series VP7 6

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)

Series VQ Port Solenoid Valve

HN B G1/US B G2/US B G3

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

3 Port Solenoid Valve

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. Semi-standard

Transmitters: Relay Valve

Pilot operated 2 port solenoid valve (general purpose valve) AP11/AP12 Series. Air, water, kerosene, oil (50 mm 2 /s or less) -10 to to 60 B

Direct Operated 3 Port Solenoid Valve

Series VCHR. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

VX Z. Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve VXZ22/23. For Air, Water, Oil. New. Series

AV2000-A/3000-A/4000-A/5000-A

PD3/PDV3-20A/25A/40A Series

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

Standard Specifications. Fluid Standard specifications. VH600 Ambient and fluid temperature Operating angle Lubrication. Optional Specifications

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Transcription:

For General Purpose /3 Port Valve Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero. Wide variations Series VNA For controlling pneumatic systems or air-hydro circuits. A balance poppet that enables air to flow forward or backward. Series VNB For controlling various fluids Can operate with a wide range of fluids, such as air, water, oil, gas, vacuum, etc., by selecting the body material and the seal material. VX VN VQ VDW Series VNC For controlling the cutting oils and coolants used in machine tools. Metal seals are used for preventing foreign matter such as cutting chips from entering. Maximum operating pressure: 0.5MPa, MPa VC LV PA Series VNH For controlling the high pressure cutting oils and coolants used in machine tools. Maximum operating pressure: 3.5MPa, 7MPa Series VND For steam control PTFE seal adopted With indicator (Option) 4.-

Series VN Process Valve zseries Valve Style Process valve Series VNA N.C. N.O. C.O. Process valve Series VNB Coolant valve Series VNC Coolant valve for high pressure Series VNH Steam valve Series VND N.C. N.O. C.O. N.C. N.O. N.C. N.C. N.O. Applicable fluid Water Air Oil Low vacuum ( Torr) Coolant Steam 8 3 4 Page P.4.-3 to P.4.-0 P.4.- to P.4.-8 P.4.-9 to P.4.-6 P.4.-7 to P.4.-3 P.4.-33 to P.4.-40 4.-

Compressed Air Port Valve for Comressed Air and Air-hydro Circuit Control Process Valve Series VNA Universal Port Valve Exclusively for air pressure system and air-hydro circuit control The cylinder operation by external pilot air The balance poppet permits normal and reverse flow. Air pressure circuit: Application examples Operation from 0 MPa is possible Wide variations N.C., N.O., C.O., are available. Screw-in styles, 6A to 50A, are standardized. Actuator stop valve Emergency stop, intermediate stop, inching Actuator skip valve Terminal deceleration, intermediate deceleration, accelerative start Actuator exhaust valve High speed operation, highspeed exhaust VX Air-hydro Operation capacity when used in air-hydro units This series can supplement the capacity of conventional air-hydro valve units. They are suited to operate large bore cylinders as well as to simultaneously operate mutliple cylinders and suspend their operation. Thus they can be used in the same as the convetional air-hydro units. Condition Supply Pressure Hydraulic fluid Load Piping length Piping dia. Air motor driving valve Air blow valve Line stop valve Residual line pressure exhaust valve Air-hydro circuit: Application example Basic circuit 0.49MPa ISO VG3 No load m VNAA 3/8B(9 mm) CCVSO VNAA / B(3 mm) CCVSO VNA3A 3/4B(9 mm) VNA4A B(5 mm) Refer to Best Pneumatics for further information on air-hydro. Caution When speed controller is mounted Connect a speed controller (Series AS etc.) to A port (cast in body A)of VNA (in order to protect the speed control valve from surges when cylinder operation is suspended, thus improving stopping accuracy) Caution Skip valve function Combination of or more valves of Series VNA provides a skip valve function. Connect the skip valve to the A port side of a stop valve as in the case of the speed control valve. 4.-3 VN VQ VDW VC LV PA

How to Order A B C Seal material NBR seal FPM seal EPR seal Refer to Table q for application. Bracket Without bracket B With bracket Only valve size,, 3, 4. Air operated VNA 0 A 5A External pilot solenoid VNA A 5A D Q Manual override Non-locking push style Valve size Orifice Symbol size (mm) 3 4 5 6 7 ø0 ø5 ø0 ø5 ø3 ø40 ø50 Note) Only air operated type. Valve style Symbol 3 Note) N.C. N.O. C.O. Symbol 6A 8A 0A 0A 5A 0A 5A 3A 40A 50A Port size RC(PT) 8 Rated voltage 00V AC 50/60Hz 3 4 00V AC 50/60Hz 3 0V AC 50/60Hz 4 0V AC 50/60Hz 5 4V DC 6 V DC 7 40V AC 50/60Hz 9 Less than 50 VAC and 50 VDC Electrical entry/indicator light and surge voltage suppressor D DIN connector DL DIN connector with indicator light and surge suppressor Order Made Contact SMC for other voltages (9) Protective class class I (Mark: )... DIN terminal type Table q Applicable fluids Model VNA A VNA B VNA C (Valve material: NBR seal) (Valve material: FPM seal) (Valve material: EPR seal) Applicable fluids Air(standard dry) CO (0.7 MPa Max.) Nitrogen gas(n) Freon, 3, 4, Turbine oil(40 to 00 cst), Hydraulic fluid Argon, Helium, Turbine oil, Hydraulic fluid (99 C) CO (0.7 MPa max.) Caution Contact SMC on other fluids, operating conditions, etc. 4.-4

External pilot solenoid valve Symbol Style Valve Air operated P Air operated valve N.C. N.O. C.O. Normally closed Normally open Double acting VNA 0 VNA 0 VNA 03 P P Model Fluid Model Port Size VNA -6A 8 VNA -8A VNA -0A VNA -0A VNA -5A VNA3-0A 3 4 VNA4-5A VNA5-3A VNA6-40A VNA7-50A Valve Specifications Fluid temperature VNA A VNA B/ C Ambient temperature Proof pressure Operating pressure range Pressure range External pilot air Lubrication Temperature Orifice size ø (mm) 0 5 0 5 3 40 50 Flow rate Weight (kg) Effective area Nl/min Air operated Solenoid (mm ) 687.05 75.95 963.00 379.70 4907.50 785.00 778.00 7667.00 748.00 404.00 3 3 35 70 90 40 0 30 500 770 0. 0.3 0.5 0.8.3. 3. 0. 0.4 0.6 0.9.4. 3. Refer to table q on page 4.-4. 5 to 60 C () 5 to 99 C () (Only air operated) 5 to 50 C (Air operated: 60 C) ().5MPa 0 tompa 0. to 0.7MPa Not required (Use turbine oil No. (ISO VG3) if lubricated) () 5 C to 50 C(Air operated: 60 C) Note ) No freezing Note ) Lubrication is not allowed in case of seal material EPR. External pilot solenoid A B VNA P A B A B VNA P A B A B P Pilot Solenoid Valve Specifications Pilot solenoid valve Electrical entry Coil rated voltage(v) Allowable voltage Coil insulation Temperature rise Apparent power Power consumption Manual override 6A to 5A 3A to 50A SF4- -3 VO30-00 DIN connector DIN connector AC(50/60Hz) 00V, 00V Others(Option) DC 4V, Others(Option) 5% to +0%(rated voltage) o Class B or equivalent (30 C) AC Inrush Holding DC 35 C (Application of rated voltage) 70 C (Application of rated voltage) 5.6VA(50Hz), 5.0VA(60Hz) VA(50Hz), 0.5VA(60Hz) 3.4VA(50Hz),.3VA(60Hz) 7.5VA(50Hz), 6VA(60Hz).8W 4.8W Non-locking push style Others (Option) Non-locking push style VX VN VQ VDW VC LV PA 4.-5

Flow Characteristics Air How to Read The Graph In the sonic flow region: For a flow of 6000 (l/min) VNA4mmm(Orificeø5)...P 0.4MPa VNA4mmm(Orificeø0)...P 0.8MPa VNA4mmm(Orificeø5)...P 0.5MPa How to Calculate Flow <Air and other gases> qequation in the domain of subsonic flow Calculation by Cv factor P(P+0.03) 73 Q=4080 Cv G 73+θ l /min (ANR) Calculation by effective area P(P+0.03) 73 Q=6 S G 73+θ l /min (ANR) wequation in the domain of sonic flow Calculation by Cv factor 73 Q=040 Cv (P+0.03) G 73+θ l /min (ANR) Calculation by effective area 73 Q=3 S (P+0.03) G 73+θ l /min (ANR) Turbine oil (ISO VG3) How to Read The Graph In case of a flow of oil 00 l/min: VNA4 (Orificeø4)... P 0.035MPa VNA4 (Orificeø0)... P 0.08MPa VNA4 (Orificeø5)... P 0.MPa How to Calculate Flow Calculation by Cv factor Q=4. Cv 0. P G...l/min Calculation by effective area 0. P Q=0.8 S...l/min G Note) Calculation error of fluid with viscosity of 50 cst or less will be very small. Symbol Q : Flow rate (Air and other gases l/min (ANR)) (Water and other liquids l/min) P: Pressure differential (P-P) P : Upstream pressure (MPa) P : Downstream pressure (MPa) θ : Temperature of air and other gases ( C) S : Effective area (mm ) S 7667. Nl/min Cv : Cv factor ( / ) G : Specific gravity ( / ) Air/Water= 4.-6

6A, 8A, 0A VX VN Model VNA -6A VNA -8A VNA -0A Main Port 8 DZ: 9mm longer VQ VDW VC LV PA 4.-7

0A, 5A, 0A, 5A DZ: 9mm longer Model VNA -0A VNA -5A VNA3-0A VNA4-5A Main Port 3 4 A 63 80 90 B 4 50 60 C 8 35 40 D 4 7.5 0 E 7.5 84 00 F 80.5 9 08 I 8.5 9.5 97.5 L 4.5 54 70 M 5 6 7 N 6 3 36 P 4.5 5.5 6.5 Q 4.3 8.3 33.3 R.3.3.3 S 5 30 35 T 34 43 49 U 55 60.5 73 3A, 40A, 50A Model VNA5-3A VNA6-40A VNA7-50A Main Port Pilot port 8 A 05 0 40 B 77 96 3 C 53 60 74 D 6.5 30 37 E 0.5 37 60 F 0 4 4 G 9.5 47 70 J 9.5 37 60 M 55 63 74 4.-8

Construction Component Parts No. Description Material Note q Body Aluminium alloy Platinum silver painted w Cover assembly Aluminium alloy Platinum silver painted e () Plate assembly Aluminium alloy Valve material(nbr, FPM, EPR) r () Valve element Aluminium alloy Valve material(nbr, FPM, EPR) t Piston assembly Aluminium alloy y Travel spring Stainless steel u Return spring Piano wire i Pilot solenoid valve Note ) Parts e, r are for selection of valve composition. Operation Principles VNA 0, (N.C.) When the pilot solenoid valve is not energized (or when air is exhausted from the P port of the air operated style),the valve element linked to the piston is closed by the return spring. When valve element opens When the pilot solenoid valve is energized (or when pressuried air enters through the P port of the air operated style), the pilot air that has entered under the piston moves it upward to open the valve element. When valve element opens When the power to the pilot solenoid valve is turned off (or when air is exhausted from the P port of the air operated style), the pilot air under the piston is exhausted, and the return spring closes the valve element. VNA 0, (N.O.) In contrast with the N.C., when the power to the pilot solenoid valve is turned off (or when air is exhausted from the P port of the air operated style), the valve is held open by the return spring. When the pilot solenoid valve is energized (or when pressurized air enters through the P port of the air operated style), the valve element closes. VNA 03 (C.O.) The valve element of the C.O. type, which has no return spring, is in an arbitary position when air is exhausted through the P and P ports. When pressurized air enters the P port (exhaust from the P port), the valve element opens, and it closes when pressurized air enters the P port (exhaust from the P port). VX VN VQ VDW VC LV PA Replacement Parts No. e r i Plate assembly Description Valve disc (Valve disc a'ssy for 5A-50A) Pilot solenoid valve Valve material Valve material NBR FPM EPR NBR FPM EPR VNA A -6A, 8A, 0A VN-A3AA VN-A3AB VN-A3AC VN-4AA VN-4AB VN-4AC VNA -0A, 5A VN-A3AA VN-A3AB VN-A3AC VN-4AA VN-4AB VN-4AC VNA3-0A VN3-A3AA VN3-A3AB VN3-A3AC VN3-4AA VN3-4AB VN3-4AC SF4- -3 (Refer to p.4.-0 for details) Part No. VNA4-5A VN4-A3AA VN4-A3AB VN4-A3AC VN4-A4AA VN4-A4AB VN4-A4AC VNA5-3A VN5-A3AA VN5-A3AB VN5-A3AC VN5-A4AA VN5-A4AB VN5-A4AC VNA6-40A VN6-A3AA VN6-A3AB VN6-A3AC VN6-A4AA VN6-A4AB VN6-A4AC VNA7-50A VN7-A3AA VN7-A3AB VN7-A3AC VN7-A4AA VN7-A4AB VN7-A4AC VO30-00 (Refer to p.4.-0 for details) 4.-9

How to Order Pilot Solenoid Valve Valve size,, 3, 4 SF4 DZ 3 Coil rated voltage 00V AC 50/60Hz 00V AC 50/60Hz 3 0V AC 50/60Hz 4 0V AC 50/60Hz 5 4V DC 6 V DC 7 40V AC 50/60Hz 9 Less than 50 VAC and 50 VDC Order Made Contact SMC for other voltages (9) Protective class class I (Mark: )... DIN terminal type Q Manual override/classification Non-locking push style Electrical entry/indicator light and surge voltage suppressor. D DIN connector DIN connector with indicator DZ light and surge voltage suppressor VO30-00 Coil rated voltage 00V AC 50/60Hz 00V AC 50/60Hz 3 0V AC 50/60Hz 4 0V AC 50/60Hz 5 4V DC 6 V DC 7 40V AC 50/60Hz 9 Other less than 50VAC and 50 VDC Option Valve size 5, 6, 7 D DL Surge voltage suppressor None S Surge voltage suppressor (Except for DL) Electrical entry Option Q DIN connector DIN connector with indicator light Note ) When the electrical entry is D, the pilot solenoid valve parts are as follows: VO30-00 D -X30 Indicator light and surge voltage suppressor Coil rated voltage Precautions Be sure to read before handling. Refer to p.0-33 for Safety Instructions and p.0-37 to 0-40 for common precautions. External Pilot Caution Pilot port piping Please arrange P and P piping as follows according to the model. Port P P VNA 0 External pilot Bleed port VNA 0 VNA 03 VNA Bleed port External pilot External pilot External pilot Pilot exhaust Pilot exhaust It is recommended to mount a silencer in the EXH port and the bleed port for noise reduction and dust entry prevention. Piping Caution To use the piping with a high temperature fluid, use heat resistant fittings and tubes. (Self-align fittings, Teflon tube copper pipe, etc.) Teflon is a registered trademark of Dupont. Use with Air-hydro Unit Warning.Piping When operation is suspended, surge pressure will be generated between the cylinder and VNA A. To directly thread in the cylinder, use durable fittings (SUS square nipples etc,) instead of ductile iron fittings (JIS B 30) or steel pipe fittings (JIS B 30). When VNA A is to be installed away from the cylinder, use a high-pressure rubber hose (JIS B 6349) instead of steel pipe as much as possible. Caution.Air bleeding Valves of Series VNA have no air bleeding port. Bleed air from the middle piping. Bleeding by a vaccum pump is more effective..hydraulic fluid Turbine oil, Grade, ISO VG3, with petroleum hydraulic fluid is recommended. 3.Speed control valve The combination shown in the following table is recommended to bring the best of Series VNA. (Piping: JIS K 6349 high pressure hose) Combination of Series VNA and flow control valve (Series AS) 0A 5A 0A 5A 3A 40A 50A VNA 3 4 5 6 7 AS 40-03 40-04 500-06 600-0 800-900-4 900-0 Piping (I.D.) B(ø9.5) B(ø.7) 3 4 B(ø9.) B(ø5.4) B(ø3.8) B(ø38.) B(ø50.8) 4.-0