OMEGA. HH63KF-MV Temperature Transducer

Similar documents
OMEGA. CL3512 Digital Thermometer & Calibrator

User s Guide. FLSC790-ND-P Pulse Output Module. omega.com.

OMEGA. RH62F-MV Humidity Temperature Transducer

OMEGA. HH501AJ Digital Thermometer

User s Guide WT Shop online at. Benchtop Closed Loop Wind Tunnel with Controller

User s Guide. FLSC790-P Pulse Output Module For use with FTB790 Series Turbine Meters with Display Electronics. omega.com

User s Guide WT Shop online at. Unique Open Loop Wind Tunnel. omega.com For latest product manuals: omegamanual.

User s Guide WT Shop online at. Research Quality Benchtop Wind Tunnel

OMEGA. HHM598T Digital Trms Clamp-On Meter

User s Guide LV860. Level Sensor. Shop online at.

User s Guide WT Shop online at. Customized Research Quality Wind Tunnel

OMEGA. OS641C-MV Infrared Temperature Transducer

User s Guide. Model PX750 Smart Kit. PX750 Smart Kit

User s Guide. Series DPG701. Room Pressure Monitor. omega.com.

OMEGA. HHM19C Digital Multimeter

User s Guide. OM-EL-WiFi-ALERT. Shop online at omega.com. Windows 7, 8, Vista and XP Configuration Software Installation with Operations Guide

User s Guide PSW-850 SERIES. Pressure Switches. Shop on line at.

User s Guide. TQ513 Series Rotating Torque Sensors Shaft-to-Shaft Configuration. Shop online at omega.com

PX140 Series. Pressure Transducers

User s Guide HH42A. Thermometer. Shop online at omega.com sm HH42A. For latest product manuals:

User s Guide. CRFC, CRWS, CRRS and CRFP Series Vacuum Formed Ceramic Fiber Radiant Heaters. Shop online at

User s Guide CDCE-90-X SERIES. Conductivity Sensors. Shop online at omega.com SM

PRG 350 Series Stainless Steel Regulators

User s Guide CDE-600/610. Conductivity Cells. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide. LD340 Series AC Miniature LVDT Displacement Transducers. Shop online at. Series 956. Series 956

PRG 350 Series Stainless Steel Regulators

User s Guide FP-5060 SERIES. Micro-Flow Sensors. Shop online at omega.com SM For latest product manuals:

User s Guide PSW12 SERIES. Pressure Switches. Shop online at CERTIFIED DUAL SEAL

User s Guide XXXXXX. Xxxxx Xxxxxxxx. Shop online at. omega.com For latest product manuals: omegamanual.info

FTB500 Series Low Flowrate Meters

User s Guide. LVU-19 Series. Battery Powered Level Transmitter & Display

User s Guide. LVU-90 Series. Ultrasonic Level Transmitter. Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course!

User s Guide FP-319. Flow Wet-Tap Assembly. Shop online at omega.com SM For latest product manuals:

User s Guide TL-WELD. Thermocouple and Fine Wire Welder. Shop online at omega.com

User s Guide WTM Laboratory Grade, Bench Top Mini Wind Tunnel. Shop online at omega.com

User s Guide. MTC Series. Multi-Pin Thermocouple Connectors. Shop online at omega.com

User s Guide. LD320, LD620, LD621, LD630 Series LD650, LD660, LD661, LD680 Series. Shop online at DISPLACEMENT TRANSDUCERS

User s Guide. BB-2A Blackbody Calibration Source. Shop online at omega.com. For latest product manuals:

User s Guide FP7001A. Paddlewheel Flowsensors. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide Shop online at omega.com SM For latest product manuals: CDE-285X SERIES Conductivity Sensors

User s Guide FTB4800 SERIES. S tainless Single- J et Mete r. Shop online at

DPU90-WM, FP90UM, FP90IM, PHTX-27G, PHTX-275G, FPM-5000-LTCK, FPM-5000-MB

CL552 Portable Temperature Calibrator

User s Guide PH-2720-PA. Preamplifier. Shop online at.

User s Guide FTB8000A SERIES. Pulse Mete r. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide. FP-8500A/FP5600 Series. Flow Sensors.

User s Guide. FW1000 Series Differential Pressure Flowmeters

User's Guide FPR300/310 SERIES. Shop online at. Low-Flow Meter. omega.com For latest product manuals: omegamanual.

CNi-CB120/240 SERIES. Industrial Controller Panels. Shop online at omega.com. For latest product manuals:

User s Guide FMG80A SERIES. Low-Flow Magmeter. Shop online at omega.com SM. For latest product manuals:

Servicing North America:

User s Guide. High Pressure Solenoid Valve. svh-141, 142, 143, 144, 145. Shop online at omega.com

User s Guide EP510, IP510, EP511, IP511 SERIES. Electroneumatic Converters. Shop online at

User s Guide WT4401-S & WT4401-D. Benchtop Wind Tunnels. Shop online at. WT4401-D shown

User s Guide. FMG 2550 Series Insertion Magmeter. Shop online at.

User s Guide FP7002/FP7002A. Flow/Temperature Transmitter. Shop online at omega.com

User s Guide FMA-900 SERIES. Air Velocity Transducers. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide. FDT100 Series Ultrasonic Flow Meters. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide LVD-800 SERIES. Dry Material Rotary Paddle Level Switches. Shop online at

User s Guide PX5200 M5091/0817. Shop online at omega.com SM. For latest product manuals:

PHCN-370/380 Series. ph Controllers/Recorders. Operator s Manual

User s Guide CL1201. Dry-Block Calibrator. omega.com For latest product manuals: omegamanual.info MADE IN UNITED KINGDOM

Mechanical Spiral Sensor

User s Guide. Shop online at. Omega.com For latest product manuals: Omegamanual.info

Shop online at omega.com For latest product manuals: omegamanual.info

operating manual DL7 101 DIGITAL THERMOMETER

Operator s Manual TC-253A. Temperature Converter

User s Guide FP-2540/FP Flow Sensors. Shop online at omega.com SM For latest product manuals:

FMK-2536, FP-5100, FP-5300,FP-5600, FP-8500, FP-8500A

User s Guide CL900 AND CL950 TRCIII. hot point Calibrators and. ice point Reference Cell. Shop online at

Power Supply. Model PS-200

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

User s Guide. FMG-3000 SERIES Blind Version. Magmeter. Shop online at ISO 9001 ISO 9002

User's Guide. FTB700-Series. Shop online at. Inline Turbine Meters. Carbon Steel PVC

User s Guide. Shop online at. Omega.com For latest product manuals: Omegamanual.info FPUDVS2000 SERIES

What are RTD Sensors? Why Use Them? How Do They Work?

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

IEC CONTACTORS AND OVERLOAD RELAYS

Installation Manual Model 3800/3810

Analog Durometer Model AD-100

Electropneumatic Transducer

Phase Sequence Tester

LINEAR THRUSTER SLIDES

Installation Instructions Model Geobeam


Infrared Thermocouple Probe

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

SPEED POSITIVE DISPLACEMENT INJECTOR PUMP OPERATING MANUAL

User s Guide FHG FLOW METERS. Shop online at. omega.com For latest product manuals: omegamanual.info

Universal Battery Holder Operator s Manual

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

User s Guide. FPD2000 Series. Shop online at omega.com. Positive Displacement Flow Meters

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

TABLE OF CONTENTS NOTES. 1.0 Operating principle... 02

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

1.0 Introduction Mounting Procedure Verifying Calibration Accuracy Specifications Tension Ranges...

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Power Distribution Units

80PK-2A Type K Immersion Probe

Transcription:

OMEGA HH63KF-MV Temperature Transducer

omega.com TM OMEGAnet SM On-Line Service http://www.omega.com Internet e-mail info@omega.com Servicing North America: USA: ISO 9001 Certified Canada: One Omega Drive, Box 4047 976 Bergar Stamford, CT 06907-0047 Laval (Quebec) H7L5A1 Tel: (203) 359-1660 Tel: (514) 856-6928 FAX: (203)359-7700 FAX: (514) 856-6886 e-mail: info@omega.com e-mail: info@omega.com Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands Tel: (31) 20 6418405 FAX: (31) 20 6434643 Toll Free in Benelux: 06 0993344 e-mail: nl@omega.com Czech Republic: ul. Rude armady 1868, 733 01 Karvina- Hranice, Czech Repubic Tel: 420 (69) 6311627 FAX: 420 (69) 6311114 e-mail: czech@omega.com For immediate technical or application assistance: USA and Canada: Mexico and Latin America: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA SM Tel: (95) 800-TC-OMEGA SM Customer Service: 1-800-622-2378 / 1-800-622-BEST SM FAX: (95) 203-359-7807 Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN SM En Español: (203) 359-7803 TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA e-mail: espanol@omega.com Servicing Europe: France: 9, rue Denis Papin, 78190 Trappes Tel: (33) 130-621-400 FAX: (33)130-699-120 Toll Free in France: 0800-4-06342 e-mail: france@omega.com Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel: 49 (07056) 3017 FAX: 49 (07056) 8540 Toll Free in Germany: 0800 82 66342 e-mail: germany@omega.com United Kingdom: ISO 9002 Certified One Omega Drive Riverbend Technology Centre Northbank, Irlam, Manchester, M44 5EX, England Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622 Toll Free in England: 0800-488-488 e-mail: sales@omega.com.uk

INTRODUCTION This instrument is a portable compact-sized temperature transducer designed to use external K-type thermocouple and a digital Multimetrer(DMM). The temperature transducer accepts the output of any K-type thermocouple and converts it to 1 millivolt per degree Celsius. Temperature indication follows Reference Temperature/Voltage Tables N.I.S.T. Monograph 175 Revised to ITS-90 for K-type thermocouples. One K-type thermocouple is supplied with the thermometer. SAFETY INFORMATION It is recommended that you read the safety and operation instructions before using the temperature transducer. WARNING To avoid electrical shock, do not use this instrument when voltages at the measurement surface exceed 24V AC or DC. 1

WARNING To avoid damage or burns, do not make temperature measurement in microwave ovens. CAUTION Repeated sharp flexing can break the thermocouple leads. To prolong lead life, avoid sharp bends in the leads, especially near the connector. The symbol on the instrument indicates that the operator must refer to an explanation in this manual. 2

SPECIFICATIONS ELECTRICAL Temperature Scale: Fahrenheit. Measurement Range: -58 F to 2372 F. Output: 1mV/1 F. Accuracy: Accuracy is specified for operating temperatures over the range of 64 F to 82 F, for 1 year, not including thermocouple error. ±(0.3%rdg + 2 F) -58 F to 1832 F ±(0.5%rdg + 2 F) 1832 F to 2372 F Temperature Coefficient: 0.1 times the applicable accuracy specification per F from 32 F to 64 F and 82 F to 122 F. Input Protection: 24V dc or 24V ac rms maximum input voltage on any combination of input pins. Input Connector: Accepts standard miniature thermocouple connectors. 3

ENVIRONMENTAL Ambient Operating Ranges: 32 F to 122 F <80% R.H. Storage Temperature: -4 F to 140 F <70% R.H. GENERAL Battery: 4 pcs 1.5V (AAA size). Battery Life: 200 hours typical. Dimensions: 170mm(H) x 44mm(W) x 40mm(D). Weight: 140g. 4

OPERATING INSTRUCTIONS 1. Plug the temperature transducer test leads into the dc volts input of the Multimeter. Observe polarity. 2. Set the multimeter to the 200mV range. 3. Use the 2V range for higher temperatures. Ignore the decimal point. 4. Plug the K-type thermocouple into the temperature transducer thermocouple input connector. 5. Turn on the temperature transducer and the multimeter. Temperature transducer Green LED Lighted. 6. Read the temperature on the multimeter. 5

OPERATOR MAINTENANCE WARNING To avoid possible electrical shock, disconnect the thermocouple connectors from the thermometer before removing the cover. Battery Replacement Power is supplied by four 1.5V (AAA size) batteries. The red LED Lighted when replacement is needed. To replace the batteries, remove the screw from the back of the meter and lift off the battery cover. Remove the batteries from battery contacts. 6

WARRANTY OMEGA warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA's customers receive maximum coverage on each product. If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA's Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. However, this WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA's control. Components which wear or which are damaged by misuse are not warranted. This includes contact points, fuses, and triacs. OMEGA is glad to offer suggestions on the of use of its various products. Nevertheless, OMEGA only warrants that the parts manufactured by it will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. Every precaution for accuracy has been taken in the preparation of this manual; however, OMEGA ENGINEERING, INC. neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages that result from the use of the products in accordance with the information contained in the manual. SPECIAL CONDITION: Should this equipment be used in or with any nuclear installation or activity, purchaser will indemnity OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the equipment in such a manner.

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient connected application. RETURN REQUESTS / INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA'S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. P.O. number under which the product was PURCHASED. 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. P.O. number to cover the COST of the repair. 2. Model and serial number of product, and 3. Repair instructions and/or specific problems relative to the product. OMEGA's policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. Copyright 1999 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable from, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! HEATERS þ Heating Cable þ Cartridge & Strip Heaters þ Immersion & Band Heaters þ Flexible Heaters þ Laboratory Heaters PRESSURE/STRAIN AND FORCE þ Transducers & Strain Gauges þ Load Cells & Pressure Gauges þ Displacement Transducers þ Instrumentation & Accessories FLOW/LEVEL þ Rotameters, Gas Mass Flowmeters & Flow Computers þ Air Velocity Indicators þ Turbine/Paddlewheel Systems þ Totalizers & Batch Controllers M-2873/0799 TEMPERATURE þ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies þ Wire: Thermocouple, RTD & Thermistor þ Calibrators & Ice Point References þ Recorders, Controllers & Process Monitors þ Infrared Pyrometers ENVIRONMENTAL MONITORING AND CONTROL þ Metering & Control Instrumentation þ Refractometers þ Pumps & Tubing þ Air, Soil & Water Monitors þ Industrial Water & Wastewater Treatment þ ph, Conductivity & Dissolved Oxygen Instruments ph/conductivity þ ph Electrodes, Testers & Accessories þ Benchtop/Laboratory Meters þ Controllers, Calibrators, Simulators & Pumps þ Industrial ph & Conductivity Equipment DATA ACQUISITION þ Data Acquisition & Engineering Software þ Communications-Based Acquisition Systems þ Plug-in Cards for Apple, IBM & Compatibles þ Datalogging Systems þ Recorders, Printers & Plotters