PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

Similar documents
Wind Power Inverter WINDY BOY 5000A/6000A

PV inverter SUNNY MINI CENTRAL 7000HV

System Description SMA FLEXIBLE STORAGE SYSTEM in the United Kingdom

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Multi-Function Interface MULTI-FUNCTION RELAY

Accessories for power generation plants in Italy SMA GRID GATE

PV Inverter SUNNY BOY 3300/3800

System description Multicluster Systems with Stand-Alone Grid or Increased Self-Consumption and Battery-Backup Function

System description Off-Grid Systems with SUNNY ISLAND 4.4M / 6.0H / 8.0H

System Monitoring SCHOOLMETERBOX AU

Installation - Quick Reference Guide Off-Grid Systems

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

PV Inverter SUNNY BOY 3300/3800

Wind power inverter WINDY BOY 5000-US/6000-US WINDY BOY 7000-US/8000-US. 1 Notes on this addendum. 1.1 Validity. 1.2 Target group

Operating Manual SUNNY ISLAND 3.0M / 4.4M / 6.0H / 8.0H SUNNY REMOTE CONTROL. SI30M-44M-60H-80H-BE-en-33 Version 3.3 SUNNY REMOTE CONTROL

Version: 1.0 Mat.-Nr.: DBUS-WB50-80US

Sunny Tripower. Can do everything that we can

Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT

PV inverter SUNNY BOY 2100TL

User Manual SMA FUEL SAVE CONTROLLER 2.0

User Manual SMA FUEL SAVE CONTROLLER 2.0

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6

Wind Power Inverter WINDY BOY 1100LV

Operating Manual SUNNY BOY 3600 / 5000 SMART ENERGY BATTERY PACK SMART ENERGY

Wind Power Inverter WINDY BOY 1200/1700

Charge controller SUNNY ISLAND CHARGER

Installation Manual SUNNY TRIPOWER 5000TL / 6000TL / 7000TL / 8000TL / 9000TL

Operating Manual NA-BOX 12

Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20

Planning Guidelines SMA SMART HOME The System Solution for Greater Independence

System Description SMA FLEXIBLE STORAGE SYSTEM with BatteryBackup Function

Operating Manual SUNNY TRIPOWER 15000TL / 20000TL / 25000TL

Service Manual for Installers SUNNY TRIPOWER 5000TL/6000TL/7000TL/8000TL/9000TL/ 10000TL/12000TL

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

Operating parameters WINDY BOY

Micro Inverter with Communication Unit SUNNY BOY 240-US SUNNY MULTIGATE-US

Wind Power Inverter WINDY BOY 3600TL / 5000TL

Installation Manual SUNNY CENTRAL 500CP XT/630CP XT/720CP XT/ 760CP XT/800CP XT/850CP XT/900CP XT/1000CP XT

Technical Information Control of the Active Power Feed-In at the Grid-Connection Point with the SMA CLUSTER CONTROLLER

Installation Manual SMA POWER CONTROL MODULE

Technical Information Temperature Derating for Sunny Boy and Sunny Tripower

Planning Guidelines SMA SMART HOME The System Solution for more Independence

Service manual SUNNY TRIPOWER 5000TL / 6000TL / 7000TL / 8000TL / 9000TL

SMA Export Control Solution

Service Manual SUNNY BOY 1300TL/1600TL/2100TL

System description SMA FLEXIBLE STORAGE SYSTEM

Operating Parameters SUNNY BOY / SUNNY MINI CENTRAL

Simple and secure monitoring

Certificate of Conformity self-generation unit

Installation Manual Retrofitting of the Option "Noise Reduction" SUNNY CENTRAL of the CP XT Series and SUNNY CENTRAL STORAGE

500 / 630 / 720 / 760 / 800 / 850 / 900

SUNNY BOY 2000HF / 2500HF / 3000HF

Sunny Mini Central 5000/6000 Central inverter for homogeneous PV-plants

Technical Information PV Inverters

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

Technical Information SUNNY BOY / SUNNY TRIPOWER Temperature Derating

SolarMax MT series The all-rounder for trade and industry

SolarMax S series (Australia) Maximising solar plant yields can be so easy.

Dr. Bernd Engel. Frank Greizer Joachim Laschinski Dr. Mike Meinhardt Dr. Matthias Victor. 20 th European PV Conference Barcelona 2005

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

Installation Manual 485 Data Module Type B

Planning Guidelines SMA FLEXIBLE STORAGE SYSTEM WITH BATTERY-BACKUP FUNCTION

Installation Manual 485 Data Module Type B

Integrated Plant Control and Q on Demand 24/7 SUNNY TRIPOWER

Installation Manual AUTOMATIC BACKUP UNIT

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

Installation Guide SUNNY TRIPOWER 60

SMA COMMERCIAL PRODUCTS SUNNY TRIPOWER CORE1. Stands on its own. Up to 60 % faster installation for commercial PV systems

SIZING OF SOLAR GENERATOR

Sunny Tripower CORE1.

Operating manual UPS - System

PV Inverter SUNNY BOY 2000HF-US / 2500HF-US / 3000HF-US

Price list - Inverter

SolarMax S series (United Kingdom) Maximising solar plant yields can be so easy.

Operating Manual SUNNY BOY STORAGE 2.5

Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English

SolarMax 50TS/80TS/100TS/300TS. Ready for the future.

SUNNY BACKUP System. Solar Power Even in the Event of Grid Failure

SUNNY TRIPOWER 12000TL-US / 15000TL-US / 20000TL-US / 24000TL-US / 30000TL-US

Operating Parameters SUNNY BOY/SUNNY MINI CENTRAL/WINDY BOY

System Monitoring SUNNY SENSORBOX

SMA Utility Power System

Installation manual AUTOMATIC BACKUP UNIT

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

KeContact P20. User manual

[RENEX] [İstanbul, Ekim 2011]

Planning Guidelines SMA SMART HOME

SOLAR4SAVINGS SYSTEMS

SolarMax MT series. The power pack for maximum yields.

USER MANUAL MPS 1-5KW SERIES

BlinkerBeam SL80 Controller User Guide

Operating Instructions

MICRO-INVERTER OMNIKSOL M-300

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable

Total number of PV modules: 42 Energy usability factor: 99.9 % Number of PV inverters: 1

Transcription:

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control User Manual SMC9-11TLRP-BA-en-30 TBEN-SMCTLRP Version 3.0 EN

SMA Solar Technology AG Table of Contents Table of Contents 1 Information on this Document....................... 5 2 Safety.......................................... 7 2.1 Intended Use........................................ 7 2.2 Safety Precautions.................................... 8 3 Product Description............................... 9 3.1 Sunny Mini Central 9000TL / 10000TL / 11000TL with Reactive Power Control................................ 9 3.2 Type Label........................................ 11 3.3 Electronic Solar Switch (ESS).......................... 13 3.4 Display and LEDs................................... 14 3.5 Communication..................................... 15 4 Display........................................ 16 4.1 Operating the Display............................... 16 4.2 Display Messages during the Start-Up Phase.............. 16 4.3 Display Messages during Operation.................... 17 4.4 Display Messages during a Fault....................... 17 4.5 DC Overvoltage.................................... 17 5 LED Signals..................................... 18 6 Cleaning the Inverter............................. 19 7 Glossary....................................... 20 8 Contact........................................ 21 User Manual SMC9-11TLRP-BA-en-30 3

Table of Contents SMA Solar Technology AG 4 SMC9-11TLRP-BA-en-30 User Manual

SMA Solar Technology AG 1 Information on this Document 1 Information on this Document Validity This document is valid for the following device types: SMC 9000TLRP-10 SMC 10000TLRP-10 SMC 11000TLRP-10 Target Group This document is intended for end users. Additional Information Links to additional information can be found at www.sma-solar.com: Document title Operating parameters Document type Technical description Symbols Symbol Explanation Indicates a hazardous situation which, if not avoided, will result in death or serious injury Indicates a hazardous situation which, if not avoided, could result in death or serious injury Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury Indicates a situation which, if not avoided, could result in property damage Information that is important for a specific topic or goal, but is not safety-relevant Indicates an essential requirement for achieving a specific goal Desired result A problem that might occur User Manual SMC9-11TLRP-BA-en-30 5

1 Information on this Document SMA Solar Technology AG Typography Typography Usage Example bold Display messages Nomenclature In this document, the Sunny Mini Central is also referred to as "inverter" or "product". Abbreviations Elements of a user interface Parameters Connections Elements to be selected Elements to be entered Abbreviation Designation Explanation AC Alternating Current DC Direct Current EC European Community LED Light-Emitting Diode MPP Maximum Power Point PV Photovoltaics RP Reactive Power Select the Fan test parameter and set to 1. 6 SMC9-11TLRP-BA-en-30 User Manual

SMA Solar Technology AG 2 Safety 2 Safety 2.1 Intended Use The Sunny Mini Central is a transformerless PV inverter, which converts the direct current of the PV array to grid-compliant alternating current and feeds it into the electricity grid. Figure 1: Operating principle of a PV plant with Sunny Mini Central The Sunny Mini Central is suitable for indoor and outdoor use. For safety reasons, it is not permitted to modify the product or install components that are not explicitly recommended or distributed by SMA Solar Technology AG. The Sunny Mini Central may only be used in countries for which it is approved or released by SMA Solar Technology AG and the network operators. The enclosed documentation is an integral part of this product. Read and follow the documentation to make proper and optimum use of the Sunny Mini Central. Keep the documentation in a convenient place for future reference. User Manual SMC9-11TLRP-BA-en-30 7

2 Safety SMA Solar Technology AG 2.2 Safety Precautions Electric Shock High voltages that can cause fatal electric shocks are present in the live components of the inverter. The following work must be carried out by an electrically skilled person only: Electrical installation Repairs Modifications Burn Hazards Some parts of the enclosure can become hot during operation. During operation, touch the inverter on the enclosure lid only. Inverter Damage Overvoltage can destroy the inverter. If the yellow LED flashes four times and the inverter shows the display message!pv-overvoltage! -!DISCONNECT DC!, inform the installer IMMEDIATELY. 8 SMC9-11TLRP-BA-en-30 User Manual

SMA Solar Technology AG 3 Product Description 3 Product Description 3.1 Sunny Mini Central 9000TL / 10000TL / 11000TL with Reactive Power Control The Sunny Mini Central is a transformerless PV inverter, which converts the direct current of the PV array to grid-compliant alternating current and feeds it into the electricity grid. Figure 2: Design of the Sunny Mini Central Item A B C D E F G Designation Ventilation grid Type label Electronic Solar Switch (ESS) LEDs Display Enclosure lid Enclosure lid screws User Manual SMC9-11TLRP-BA-en-30 9

3 Product Description SMA Solar Technology AG Symbols on the Inverter Symbol Designation Explanation Tapping You can operate the display by tapping it: Tapping once: Switches on display backlight or switches to the next display message. Tapping twice in quick succession: The inverter shows the display messages from the start-up phase. After two minutes, the backlight switches off automatically. Inverter This symbol defines the function of the green LED. The green LED indicates the operating state of the inverter. Earth fault This symbol defines the function of the red LED. The red LED indicates an earth fault, a defective varistor or a defective string fuse. Inform your installer. Observe the documentation. QR Code This symbol defines the function of the yellow LED which indicates a fault or disturbance. Inform your installer. The QR Code refers to the SMA bonus programme (for further information, please see www.sma-bonus.com). 10 SMC9-11TLRP-BA-en-30 User Manual

SMA Solar Technology AG 3 Product Description 3.2 Type Label The type label uniquely identifies the inverter. The type label is located on the right-hand side of the enclosure. Figure 3: Design of the type label Item Designation Explanation A Model Inverter device type B Serial No. Inverter serial number C Device-specific characteristics - D Additional information Field for additional information, e.g. details of standards E Date Inverter manufacture date (year-month-day) You will need the information on the type label to ensure safe use of the inverter and when seeking customer support from the SMA Service Line. The type label must be permanently attached to the inverter. User Manual SMC9-11TLRP-BA-en-30 11

3 Product Description SMA Solar Technology AG Symbols on the Type Label Symbol Designation Explanation Danger to life due to high voltages The inverter operates at high voltages. All work on the inverter must be carried out by skilled persons only. Risk of burns due to hot surfaces The inverter can get hot during operation. Avoid contact during operation. Observe the documentation. Observe all documentation that is supplied with the inverter. Without transformer The inverter does not have a transformer. DC Direct current AC Alternating current Degree of protection Outdoor The inverter is protected against dust intrusion and water jets from all angles. The inverter is suitable for outdoor installation. Proper disposal Do not dispose of the inverter together with the household waste. CE marking RAL quality mark for solar products Australian mark of conformity The inverter complies with the requirements of the applicable EC directives. The inverter complies with the requirements of the German Institute for Quality Assurance and Labelling. The inverter complies with the requirements of the applicable Australian guidelines. 12 SMC9-11TLRP-BA-en-30 User Manual

SMA Solar Technology AG 3 Product Description Symbol Designation Explanation Korean mark of conformity The inverter complies with the requirements of the applicable Korean guidelines. Chinese mark of conformity The inverter complies with the requirements of the applicable Chinese guidelines. 3.3 Electronic Solar Switch (ESS) The Electronic Solar Switch is part of the DC disconnection unit of the inverter. The Electronic Solar Switch must be securely plugged in at the bottom of the inverter and may only be removed by an electrically skilled person. User Manual SMC9-11TLRP-BA-en-30 13

3 Product Description SMA Solar Technology AG 3.4 Display and LEDs The display and the LEDs of the inverter are located on the enclosure lid and indicate the operating state of the inverter. Figure 4: Design of the display Item Designation Explanation A Display Two--line LC text display for displaying operating data B Tap symbol You can operate the display by tapping it (see Section 4.1 "Operating the Display", page 16). C Green LED Indicates the operating state of the inverter. D Red LED Indicates an earth fault, a defective varistor or a defective string fuse E Yellow LED Indicates a fault or disturbance. Read the manual to remedy the fault or disturbance The display shows the current operating data of the inverter (e.g. status, power, input voltage) and faults or disturbances. The LEDs indicate the operating state of the inverter, and clarify the messages in the display using different blink codes (see Section 5 "LED Signals", page 18). 14 SMC9-11TLRP-BA-en-30 User Manual

SMA Solar Technology AG 3 Product Description 3.5 Communication The inverter is equipped with a slot for connecting an SMA communication interface (e.g., RS485 or Bluetooth Wireless Technology). By means of the communication interface, the inverter can communicate with special SMA communication products (e.g. data logger, software) or other SMA inverters. The inverter parameters can only be set via SMA communication products. If you have ordered an inverter with a communication interface, it will be delivered with the communication interface built in. Depending on the type of communication, RS485 or Bluetooth, the parameters and messages will be displayed differently in the communication products. Example: Display of parameter for fan test When using RS485 communication: parameter Fan-Test When using Bluetooth communication: parameter Fan test In the inverter display, the parameters and messages are depicted independently of the connected communication interface and may also differ. User Manual SMC9-11TLRP-BA-en-30 15

4 Display SMA Solar Technology AG 4 Display 4.1 Operating the Display You can operate the display by tapping the enclosure lid. To switch on the backlight, tap once. To switch to the next display message, tap once. To display the messages from the start-up phase again, tap twice. 4.2 Display Messages during the Start-Up Phase To view the display messages of the start-up phase again during regular operation, see Section 4.1 "Operating the Display", page 16. Display message Description Inverter device type Firmware version of the internal processors Configured country data set (example: VDE-AR-N4105-MP) Configuration of the SMA Power Balancer (example: PowerGuard) 16 SMC9-11TLRP-BA-en-30 User Manual

SMA Solar Technology AG 4 Display 4.3 Display Messages during Operation When the inverter is in operation, the following messages alternate on the display. Each display message appears for five seconds, then the cycle starts again. Display message Description Current feed-in power and voltage of the PV array Current values for reactive power Qac and displacement power factor cos φ (PF) Energy produced so far and total number of hours in feed-in operation Energy generated on the current day and MPP status message 4.4 Display Messages during a Fault Display message Description Energy generated on the current day (example: 0Wh) and status message (example: Disturbance) Operating state (example: disturbance) and error message (example: Vac-Bfr) * This display message only appears if a measured value is responsible for the fault. If an error message is displayed, contact your installer. 4.5 DC Overvoltage Measured value at the time of the disturbance (example: 261 V) and current measured value (example: 245 V)* Display message Description The DC input voltage into the inverter is too high. Contact your installer immediately. User Manual SMC9-11TLRP-BA-en-30 17

5 LED Signals SMA Solar Technology AG 5 LED Signals Designation Status Cause and corrective measures All LEDs glowing The inverter is initialising. flashing The start-up phase is beginning. If the DC voltage is very low in the start-up phase, all three LEDs go out and the start-up phase recommences. If irradiation is very low, all three LEDs flash. This flashing indicates a normal operating state. It does not mean that a fault has occurred. off The ESS is not plugged in or the irradiation level is zero. Plug in the ESS securely. Green LED glowing Indicates the operating state of the inverter. The specific status message is shown in the display. flashing The DC input voltage is still too low. Once the DC input voltage is sufficiently high, the inverter goes into operation. Red LED glowing Earth fault The specific error or fault message is shown in the display. Contact your installer. flashing Varistor or string fuse defective The specific error or fault message is shown in the display. Contact your installer. Yellow LED glowing Probably a fault or warning has been issued. The specific error or fault message is shown in the display. Contact your installer. flashing Probably a fault or warning has been issued. The specific error or fault message is shown in the display. Contact your installer. 18 SMC9-11TLRP-BA-en-30 User Manual

SMA Solar Technology AG 6 Cleaning the Inverter 6 Cleaning the Inverter If the inverter is dirty, clean the enclosure lid, the display and the LEDs using only clear water and a cloth. User Manual SMC9-11TLRP-BA-en-30 19

7 Glossary SMA Solar Technology AG 7 Glossary Derating A controlled reduction in performance, usually dependent on component temperatures SMA Power Balancer The SMA Power Balancer is a serial feature of the Sunny Mini Central. The SMA Power Balancer prevents the formation of an excessive unbalanced load during three-phase feed-in. This is enabled by connecting three Sunny Mini Centrals to a three-phase feed-in unit via a control cable. Unbalanced Load The unbalanced load is the difference between the power being fed into the grid by the individual line conductors. This depends on the configured country data set and may be between 4.6 kva and 6 kva. Varistor The varistors protect the electronics in the inverter from atmospherically coupled energy peaks, such as those which can occur e.g. when lightning strikes nearby. 20 SMC9-11TLRP-BA-en-30 User Manual

SMA Solar Technology AG 8 Contact 8 Contact If you encounter technical problems, first contact your installer. The following information is required in order to provide you with the necessary assistance: Inverter device type Inverter serial number Type and number of the PV modules connected LED signal, error or fault of the inverter Optional equipment, e.g. communication products SMA Solar Technology AG Sonnenallee 1 34266 Niestetal, Germany www.sma.de SMA Service Line Inverters: +49 561 9522 1499 Communication: +49 561 9522 2499 Fax: +49 561 9522 4699 E Mail: ServiceLine@SMA.de User Manual SMC9-11TLRP-BA-en-30 21

SMA Solar Technology AG Legal Provisions Legal Provisions The information contained in this document is the property of SMA Solar Technology AG. Publishing its content, either partially or in full, requires the written permission of SMA Solar Technology AG. Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission. SMA Factory Warranty The current warranty conditions come enclosed with your device. These are also available online at www.sma-solar.com and can be downloaded and are available on paper from the usual sales channels if required. Trademarks All trademarks are recognized even if these are not marked separately. Missing designations do not mean that a product or brand is not a registered trademark. The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by SMA Solar Technology AG is under licence. QR Code is a registered trademark of DENSO WAVE INCORPORATED. SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel. +49 561 9522-0 Fax +49 561 9522-100 www.sma.de E-Mail: info@sma.de 2004 to 2012 SMA Solar Technology AG. All rights reserved User Manual SMC9-11TLRP-BA-en-30 23