Replacement cartridge filter

Similar documents
Block mounting filter, lateral flange-mounting possible

Line filter. Features. RE 51400/01.09 Replaces: Types 40/100 LEN 0040 to 0400; 40/100 LE 0003, 0015, 0018

Breather filter. RE 51414/02.09 Replaces: Types BF 7 SL ; BS 7 SL ; BE 7 SL ; B 7 SL

Spin-on filter according to Bosch Rexroth standard. Type 7 SL ; 7 SLS Features. Contents. RE Edition: Replaces: 01.

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

Block mounting filter, for lateral flange-mounting

Inline filter with filter element according to DIN 24550

Inline filter with filter element according to DIN 24550

Line filter with filter element according to DIN 24550

Block mounting filter, for lateral flange-mounting

Block mounting filter, for vertical flange-mounting

High-pressure inline filter, flangeable

Inline filter with filter element according to DIN 24550

Block mounting filter, for sandwich plate mounting

Inline filter. Features RE 51401/ Types 40 FLEN 0160 to 1000; 40 FLE 0045, 0055, 0120 to 0270

Type 245LEN0040 to 0400; 245LE0130, 0150

Spin-on elements. Type 80, 81 and 82. Contents. Features. RE Edition:

Type 400LDN0040 to 1000; 400LD0130, 0150

Filter elements for installation in Pall filter housings. Type 16. filter elements. Contents. Features. RE Edition:

Inline filter with filter element according to Bosch Rexroth standard. Type 16 FE Features. Contents

Inline filter with filter element according to DIN Type 350LEN0040 to 1000; 350LE0130, 0150

Inline filter with filter element according to DIN Type 445LEN0040 to Features. Contents. RE Issue: Replaces: 09.

Type 10TEN0040 to 1000; 10TE2000 and 2500

Breathing and air bleed filter, water-absorbing. Type BFSK. Contents. Features. RE Edition: Replaces: 51412

Filter elements for microfiltration. Type 46. CELLUDISC filter elements. Features. Contents. RE Edition:

Vent and bleed filter, water-absorbing. Type BFSK 25 to 125. Contents. Features. RE Edition: Replaces: 05.13

Filter elements, two-stage for installation in wind turbines with Hydac filter housings. Type 65. Filter elements. Contents.

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Throttle and throttle check valve

Suction Filters S8-455 SE56-560

Low / Medium Pressure Duplex Filter Inline mounting. Type : 40/160-LD/LDN. Filters. Accumulators. Hydraulic Symbol. Technical Data

Type 10TDN0040 to 1000; 10TD2000 and 2500

Accumulator shut-off block. Type ABZSS. Contents. RE Edition: Replaces: 05.13

Filter elements for the installation into Hydac filter housings. Type 9. and 10. filter elements. Features. Contents

Duplex tank-mounted return line filter, with filter element in accordance with DIN 24550

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Filter cooler unit with inline filter according to DIN Type ABUKG. Contents. Features. RE Edition: Replaces: 50126

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Pressure reducing valve, pilot operated

Check valve, pilot operated

Supply pressure compensator, direct operated

Pressure reducing valve, direct operated

2-way flow control valve

Pressure reducing valve, direct operated

Accumulator shut-off block. Type 0532VAW. Contents. Features. RE Edition: Replaces: 07.10

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

Pressure reducing valve, direct operated

Proportional pressure reducing valve, pilot operated

Motor-pump group. Features. Table of contents RE 51171/ Type ABAPG and ABHPG

2/2 directional seat valve, direct operated with solenoid actuation

Check valve, pilot operated

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

3/2 and 4/2 directional seat valves with solenoid actuation

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

Proportional pressure reducing valve, pilot operated

3/2 directional spool valve, direct operated with solenoid actuation

Pressure relief valve, direct operated. Type DBD..K. Contents. Features. RE Edition:

Pressure relief valve, pilot operated

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

Pressure reducing valve, direct operated, with pressure monitoring

Radial piston pump, fixed displacement

Hydraulic inch power brake valve LT 31

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Reservoir oil filler/breather

6/2 ways/positions flow diverters L (VS151-VS152-VS155)

6/2 ways/positions flow diverters

Pressure relief and feed valve, pilot operated. Type MHDBN. Features. Contents. RE Edition: Replaces:

2-way flow control valve

Axial Piston Fixed Pump A2FO

3/2 ways/positions flow diverters L (VS91-VS92-VS95)

Pressure relief valve, pilot operated

Fixed displacement radial piston pump

Axial Piston Fixed Pump A17FNO Series 10

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Proportional flow control valve, 2-way version

Check valve, pilot operated

Check valve, pilot operated. Type SV and SL. Features. Contents. RE Edition: Replaces:

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Axial Piston Fixed Displacement Pump KFA

6 to14/2 ways/positions bankable flow diverters flangeable

6/2 ways/positions flow diverters L (VS120-VS125-VS129)

Radial piston pump PR4 Series 1X

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Check valve, pilot operated

Check valve, pilot operated

Twin throttle check valve

Radial piston pump PR4 series 1X

Flow sharing control block in mono block / sandwich plate design M6-15

Type 110LEN0040 to 0400; 110LE0130, 0150

Throttle and throttle check valve

Process Inline Filter Medium / High Pressure PFM / PFH

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

6 to 12/2 ways/positions bankable flow diverters flangeable

Bourdon tube pressure switch with infinitely variable switching pressure differential

Transcription:

Replacement cartridge filter RE 426/0. /2 Type 7 SL 0 to 260; 7 SLS 90 to 260; SL 0 to 80 D Size 7 SL: 0 to 260 7 SLS: 90 to 260 SL: 0 to 80 D Nominal pressure 7 and/or bar Port up to G /4, SAE /2 (000 psi), SAE 20 Operating temperature C to +0 C (shortly down to 0 C) filter_29_d Table of contents Content Page Application, features Structure, replacement cartridge, accessories, characteristic curves, quality and standardization 2 Ordering code, 4 Standard types Maintenance indicator 6 Characteristic curves 7, 8 Unit dimensions 9, Installation, commissioning, maintenance Application Filtration of mineral oils (hydraulic and lubricating oils). Direct installation into pipelines. Direct wear protection for downstream components and systems. Optimized design for use in mobile hydraulics. Features Filters for inline installation Optimized for mobile hydraulics Installation in suction, pressure and return lines possible 7 SLS version with return flow block, patented and environmentally friendly Flow-optimized version due to D computer-supported design Low pressure drop Special highly efficient filter media

2/2 Bosch Rexroth AG Hydraulics 7 SL 0 260; 7 SLS 90 260; SL 0 80 D RE 426/0. Structure Filter head with inlet and outlet as well as holder for one or two replacement cartridges. The filter element is firmly integrated into the tank of the replacement cartridge. 7 SLS: Patented version with integrated isolator valve in the filter head for a leakage-free replacement of the replacement cartridge. Replacement cartridge Replacement cartridge with filter element in pleated design with optimized pleat density and various filter media. The filter element is the most important component of the filter system in view of prolonged life and wear protection of the system. The required cleanliness of the operating medium, the initial pressure differential and the dirt holding capacity are the most important criteria for selection. For more information on the filter material please refer to our Filter Elements brochure. Accessories Maintenance indicators They serve the monitoring of the degree of contamination of the replacement cartridge and are available as optical and optical / electronic indicator, with one or two switching points. Bypass valve To protect the replacement cartridge during startup and exceedance of the pressure differential due to contamination. Characteristic curves Our software BRFilterSelect )makes it possible to optimise filter selection, see download area http://www.boschrexroth.com/filter. Quality and standardization The development, manufacture and assembly of Rexroth industrial filters and Rexroth filter elements is carried out within the framework of a certified quality management system in accordance with ISO 900:2000. The replacement cartridge filters for hydraulic applications according to RE 426 are pressure holding equipment according to article, section 2..4 of the pressure equipment directive 97/2/EC (PED). However, on the basis of the exception in article, section.6 of the PEG, hydraulic filters are exempt from the PED if they are not classified higher than category I (guideline /9). They do not receive a CE mark.

RE 426/0. 7 SL 0 260; 7 SLS 90 260; SL 0 80 D Hydraulics Bosch Rexroth AG /2 Ordering code of the filter Pressure 7 bar = 7 bar = Design Suction and pressure line filter = SL Suction and pressure line filter with isolator valve = SLS Size 7 SL = 0/20, 0/2, 4/20, 4/2, 60/20, 60/2, 90, 0, 80 ), 260 2) 7 SLS = 90, 0, 80 ), 260 2) SL = 0, 0 D, 4, 4 D, 60, 60 D, 80, 80 D Filter rating in µm nominal Paper, non-cleanable: P, P, P2 = P absolute (ISO 6889) Micro glass, non-cleanable: HXL, HXL, H6XL, HXL, H20XL = H XL Pressure differential max. admissible pressure differential of the filter element Standard bar, with version 7 SL(S), and 8 bar, with version SL = S Element model Standard adhesive T = 0 C = 0 Special adhesive T = 70 C = H Standard material = 0 Solenoid Without = 0 Order example: 7 SL 4/2 P-S00-00H,-R0M00 S 0 0 R0 = S0 = U0 = M = V = Amending information 0 = Without R = Check valve in outlet (only with 7 SLS without bypass valve) Z = Certificates (on request) Housing material 0 = Standard material according to dimension sheet Seal NBR FKM Port Pipe thread SAE flange UNF thread Maintenance indicator 0 = without A = Pressure gauge 0 6 bar C = Vacuum meter 0.6 bar F0,2 = Vacuum switch normally open contact G0,2 = Vacuum switch normally closed contact H, = Pressure switch normally open contact J, = Pressure switch normally closed contact L = Integr. maintenance indicator opt. (only for SL) Specify switching pressure M = Integr. maintenance indicator elecr. (only for SL) Specify switching pressure P, = Pressure differential indicator opt./ electr. with connector (only for 7 SL 90-260) Bypass valve 0 = without = 0. bar 2 = 0.8 bar =. bar 4 = 2.0 bar = 2. bar 6 =.0 bar Further versions (filter materials, ports, switching pressures, etc.) are available at request. ) The filter 7 SL(S) 80 contains two replacement cartridges of size 90 (see unit dimensions on page ). 2) The filter 7 SL(S) 260 contains two replacement cartridges of size 0 (see unit dimensions on page ).

4/2 Bosch Rexroth AG Hydraulics 7 SL 0 260; 7 SLS 90 260; SL 0 80 D RE 426/0. Ordering code of the replacement cartridge Design 7 SL 0/20-0 = 80. 7 SLS 90-0 = 8. SL 0-80 D = 82. Size 7 SL = 0/20, 0/2, 4/20, 4/2, 60/20, 60/2, 90, 0 7 SLS = 90, 0 SL = 0, 0 D, 4, 4 D, 60, 60 D, 80, 80 D Filter rating in µm nominal Paper, non-cleanable: P, P, P2 = P absolute (ISO 6889) Micro glass, non-cleanable: HXL, HXL, H6XL, HXL, H20XL = H XL Pressure differential max. admissible pressure differential of the filter element standard bar, with version 7 SL(S), and 8 bar, with version SL = S S M = V = Seal NBR FKM Bypass valve 0 = without = 0. bar 2 = 0.8 bar =. bar 4 = 2.0 bar = 2. bar Element model 0 = Standard adhesive T = 0 C H = Special adhesive T = 70 C 0 = Standard material Order example: 80.4/2 P-S00-0-M Please note that when ordering replacement cartridges for filters of size 80 or 260, two replacement cartridges of size 90 or 0 must be ordered per filter (see unit dimensions on page ).

RE 426/0. 7 SL 0 260; 7 SLS 90 260; SL 0 80 D Hydraulics Bosch Rexroth AG /2 Standard types Bypass valve, cracking pressure 2.0 bar No Yes No Yes Pressure gauge, version M0, 0 6 bar No No Yes Yes Related type code characteristics ** = 00 ** = 40 ** = 0A ** = 4A Replacement cartridge filter, nominal pressure 7 bar, filter material and rating micro glass μm Type Flow in l/min Material no. 7 SL 4/2 HXL-S0-0 ** R0M00 40 R92802829 R92809208 R92802829 R928028294 7 SL 90 HXL-S0-0 ** R0M00 40 R928028290 R92809206 R92802829 R92802782 7 SL 0 HXL-S0-0 ** R0M00 R928028287 R928092 R928028298 R928028 7 SL 80 HXL-S0-0 ** R0M00 240 R928028288 R9280998 R928028299 R9280280 7 SL 260 HXL-S0-0 ** R0M00 260 R928028289 R928028292 R92802800 R92802802 Replacement cartridge filter, nominal pressure 7 bar, filter material and rating paper, μm Type Flow in l/min Material no. 7 SL 4/2 P-S0-0 ** R0M00 4 R9280976 R9280280 R92802806 R92802807 7 SL 90 P-S0-0 ** R0M00 8 R92809769 R92802808 R92802809 R928028 7 SL 0 P-S0-0 ** R0M00 90 R9280280 R928028 R9280282 R928028 7 SL 80 P-S0-0 ** R0M00 00 R92809774 R9280284 R928028 R9280286 7 SL 260 P-S0-0 ** R0M00 00 R92802804 R9280287 R9280288 R9280289 Replacement cartridge filter with return flow block, nominal pressure 7 bar, filter material and rating micro glass, μm Type Flow in l/min Material no. 7 SLS 90 HXL-S0-0 ** R0M00 R92802820 R9280282 R92802822 R9280282 7 SLS 0 HXL-S0-0 ** R0M00 R92802824 R9280288 R9280289 R92802840 Replacement cartridge filter with return flow block, nominal pressure 7 bar, filter material and rating paper, μm Type Flow in l/min Material no. 7 SLS 90 P-S0-0 ** R0M00 8 R9280284 R92802842 R9280284 R92802844 7 SLS 0 P-S0-0 ** R0M00 90 R9280284 R92802846 R92802847 R92802848 Replacement cartridge filter, nominal pressure bar, filter material and rating micro glass, μm Type Flow in l/min Material no. SL 0D HXL-S0-0 ** R0M00 2 R92802849 R928028 R928028 R9280282 SL 4D HXL-S0-0 ** R0M00 40 R928028 R9280284 R928028 R9280286 SL 60D HXL-S0-0 ** R0M00 90 R9280287 R9280288 R9280289 R92802860 SL 80D HXL-S0-0 ** R0M00 0 R9280286 R92802862 R9280286 R92802864 Replacement cartridge filter, nominal pressure bar, filter material and rating paper, μm Type Flow in l/min Material no. SL 0D P-S0-0 ** R0M00 0 R9280286 R92802866 R92802867 R92802868 SL 4D P-S0-0 ** R0M00 4 R92802869 R92802870 R9280287 R92802872 SL 60D P-S0-0 ** R0M00 R9280287 R92802874 R9280287 R92802876 SL 80D P-S0-0 ** R0M00 20 R92802877 R92802878 R92802879 R92802880

6/2 Bosch Rexroth AG Hydraulics 7 SL 0 260; 7 SLS 90 260; SL 0 80 D RE 426/0. Maintenance indicator Maintenance indicators serve the monitoring of the degree of contamination of the replacement cartridge. They are available as optical, electronic or optical / electronic indicators. Technical data see Maintenance indicator brochure Ø Ø 4 2 SW9 G/4 conical G/8 conical G/4 Backpressure gauge M 0 Vacuum gauge M 070 Opt.-mech. indicator P, Material number: R92809224 Material number: R92802266 Material number: R9280922 in the type code: A in the type code: C in the type code: D A B A B A B Protective cap Protective cap 70 PG9 42 PG9 SW24 SW24 ~ Pressure switch Normally open contact H, HS 2 00M* Normally closed contact H, HA 2 00M* Material number: R9280929 (normally open contact) R9280628 (normally closed contact) in the type code: Normally open contact: H, Normally closed contact: J, P 4 Vacuum switch Normally open contact I0,2 HS 2 00M* Normally closed contact I0,2 HA 2 00M* Material number: R928089 (normally open contact) R928047 (normally closed contact) in the type code: Normally open contact: F0,2 Normally closed contact: G0,2 H: Normally open contact F: Normally open contact J: Normally closed contact G: Normally closed contact P 4 72 For 7 SL(S): Pressure differential indicator optical/electric with connector F, GW 02 00M* Material number: R928096 in the type code: P, For SL: Pressure differential indicator electric with connector W... GW 02 00M* Material number: Various, depending on the switching pressure in the type code: M... (Specify switching pressure) 2 4 4 P P A B A B A B * M = NBR seal, alternatively V = FKM seal

Hydraulics Bosch Rexroth AG RE 426/0. 7 SL 0 260; 7 SLS 90 260; SL 0 80 D Characteristic curves Specific weight: < 0.9 kg/dm Oil viscosity 0 mm2/s Dp Q characteristic curves for complete filters HXL 7 SL 0 0, HXL 7 SL 4 0, 2 20 0 2 7 SL 60 0, 7 SL(S) 90 0, 2 20 0 20 0 200 7 SL(S) 0 0, 7 SL(S) 80 20 0 P recommended initial Dp for design = 0. bar recommended max. flow velocity = m/s 0, 20 0 200 20 0 0 200 00 7/2

8/2 Bosch Rexroth AG Hydraulics 7 SL 0 260; 7 SLS 90 260; SL 0 80 D RE 426/0. Characteristic curves Specific weight: < 0.9 kg/dm Oil viscosity 0 mm2/s Dp Q characteristic curves for complete filters HXL HXL P 7 SL(S) 260 recommended initial Dp for design = 0. bar recommended max. flow velocity = m/s 0, 20 0 0 200 00 0 SL 0 0, 2 20 0 0, 2 20 0 0 SL 80 SL 60 0, SL 4 0, 2 20 0 200 20 0 200

RE 426/0. 7 SL 0 260; 7 SLS 90 260; SL 0 80 D Hydraulics Bosch Rexroth AG 9/2 Unit dimensions: 7 SL 0/20 0, 7 SLS 90 0, SL 0 80 D (dimensions in mm) 7 SL 0/20 0 7 SLS 90 0 D C SL 0 80 D B D B2 A B A A A4 A4 A2 C A2 C A C2 B B Port for: B + D = Pressure gauge or pressure switch A + C = Vacuum meter or vacuum switch A B4 C2 C4 B B2 C D(not with sizes 90 and 0) Frame size Replacement cartridge port 7 SL 0/20 SAE 8 (UNF /4-6) 7 SL 0/2 G/4 7 SL 4/20 SAE 8 (UNF /4-6) 7 SL 4/2 G/4 7 SL 60/20 UNF -2 7 SL 60/2 G/4 Volume in l Weight in kg ) 0. 0.8 9 0. 0.9 46.2. 20 7 SL 90 2.0.6 8 G /4 7 SL 0 2.7.9 2 7 SLS 90 2.0.8 8 M 42 x 2 7 SLS 0 2.7 2. 2 SL 0 UNF -2 SL 0 D SL 4 D SL 4 SL 60 SL 60 D SL 80 D UNF /8-2 UNF -2 UNF /8-2 SL 80 UNF -2 0.6. 0.9. 49..4 2.. 240 A A2 A 2) A4 B B2 B B4 C C2 C D 4 R0 S0 U0 20 9 22 8 22 G/4 Ø 92 40 28 SAE 20 69 40 48 G /4 ( /8-2 UN) Ø 28 20 9 27 M 8 6 60 2 0 47 44 8 ) Weight including standard replacement cartridge and maintenance indicator 2) Servicing height for replacement cartridge G/4 G SAE (7/8-4 UNF) Ø 92

/2 Bosch Rexroth AG Hydraulics 7 SL 0 260; 7 SLS 90 260; SL 0 80 D RE 426/0. Unit dimensions: 7 SL 80 260, 7 SLS 80 260 (dimensions in mm) D C B2 C A A A4 A2 A C2 B Port for: A = Vacuum meter or vacuum switch B = Pressure gauge or pressure switch A C C D B B Frame size Replacement cartridge port Volume in l Weight in kg ) 7 SL 80 2.0.0 8 G /4 7 SL 260 2.7.2 2 7 SLS 80 2.0. 8 M 42 x 2 7 SLS 260 2.7. 2 A A2 A 2) A4 A B B2 B C C2 C D 90 20 4 8 40.7 69.9 60 G /2 R0 S0 U0 SAE /2 000 psi Ø 28 M 2 ) Weight including standard replacement cartridge and maintenance indicator 2) Servicing height for replacement cartridge

RE 426/0. 7 SL 0 260; 7 SLS 90 260; SL 0 80 D Hydraulics Bosch Rexroth AG /2 Installation, commissioning and maintenance Filter installation Verify operating pressure with nameplate information. Screw the filter head (item ) to the fastening devices, considering flow direction (direction arrows) and servicing height of the replacement cartridge. Remove dust protection plugs from filter inlet and outlet, screw filter in pipeline without tension stress. Connection of the electronic maintenance indicator Establish the connection using a three-wire cable, observe the switching power on the nameplate of the maintenance indicator. Connection versions:. Normally open contact: (sw) + (bl) 2. Normally closed contact: (sw) + 2 (br). Changeover contact: (sw) + 2 (br) + (bl) Warning! Assemble and disassemble filter only when system is depressurized! Tank is under pressure! Do not replace the maintenance indicator while the filter is under pressure! Functional and safety warranty only applicable when using genuine Rexroth spare parts! Service filter only by trained personal! Commissioning Switch on system pump. Maintenance If the red indicator pin reaches out of the maintenance indicator and/or if the switching process in the electronic display is triggered, the maintenance indicator has reached the pressure value and the replacement cartridge has to be renewed. Exchange of the replacement cartridge Switch of the operating pump. Screw off the replacement cartridge and replace it with a new cartridge. When doing so, use the seal / seal ring of the new cartridge. Manually tighten the cartridges of pressure rating 7 bar (7 SL, / 7 SLS ). For assembling the cartridge of pressure rating bar ( SL...), an assembly line can be used. In this connection, do not overtighten the cartridge as there is the risk of damaging the sheet tank. Perform the commissioning as described above. Technical modifications reserved!

2/2 Bosch Rexroth AG Hydraulics 7 SL 0 260; 7 SLS 90 260; SL 0 80 D RE 426/0. Notes Bosch Rexroth Filtration Systems GmbH Hardtwaldstraße 4, 6877 Ketsch, Germany POB 20, 68768 Ketsch, Germany Phone +49 (0) 62 02 / 6 0-0 Fax +49 (0) 62 02 / 6 0-99 brfs-support@boschrexroth.de www.eppensteiner.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.