t EVAPORATOR PRESSURE REGULATING VALVES

Similar documents
April 2004 / BULLETIN for Supermarket Systems DDR-20 OLDR-15

Condensed Catalog 410A January 2008

611H Flo-Con Pressure Regulators & Valves

Crankcase Pressure Regulating Valves

Solenoid Valves. Installation and Servicing Instructions SD-15/ TYPES B6, B9, B10, B14, B19, B25 SERIES (Brass Connections) GENERAL

November 2015 / BULLETIN Solenoid Valves. Installation and Servicing Instructions ENGINEERING YOUR SUCCESS

Refrigeration Solenoid Valves & 3-Way Heat Reclaim Valves

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants.

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory)

Subcritical CO 2 Innovations

(S)PORT - (S)PORT-II Evaporator Pressure Regulators

Pulse Width Modulation Valves. Models SPW-0 thru -7

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

Refrigerating Specialties Division 1. BULLETIN DN23-05B Type A4A-DN, A4AK-DN, A4AE-DN, A4AR-DN. January 2007 Installation and Service Information

EVAPORATOR PRESSURE REGULATORS

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

Installation, Operation and Maintenance Manual

BULLETIN Type A4AM. March 2002 Installation, Service and Parts Instruction. Refrigerating Specialties Division Fig.

SOLENOID VALVES SOLDER CONNECTIONS

Steel Suction Line Accumulators

3-Way Valves. Installation and Servicing Instructions

B21 Series BASOTROL Gas Valve

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

I & M MK96 & MK96C. Ideal Installation. Start-Up. Maintenance PROTECT VALVES WITH LINE STRAINERS

Airsweep Installation & Maintenance Manual. Airsweep Models VA-06 VA-12 VA-51 SECTION THREE SOLENOID VALVES

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

Defrost Differential Pressure Regulating Valves Installation and Service Instructions

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

Instructions for Installation, Operation, Care and Maintenance

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Crankcase pressure regulator Type KVL

TECHNICAL DATA CAUTION

PRESSURE REDUCING VALVE

INSTRUCTIONS FOR INSTALLATION, START-UP, AND OPERATION

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Crankcase pressure regulator Type KVL

V46 and V47. Repair Parts and Service Instructions. Applications. Adjustments. Installation Guidelines

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )

Sporlan V-Series Ruby Seat Solenoid Valves

PRODUCT DATA HDF SERIES Solenoid Valve

Baumann Series Flexsleev Control Valve Instructions

Installation Instructions

SAFETY RELATED MANDATORY OUTRIGGER CYLINDER INSPECTION AND REPAIR

ADAPTOMODE INLET PRESSURE REGULATORS Types: A4AS, A4AB, A4AD, A4AZ

ANSI/AHRI Standard 760 (I-P) 2014 Standard for Performance Rating of Solenoid Valves for Use with Volatile Refrigerants

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

Solenoid valve for R410A and R744 Types EVR 2 - EVR 6 and EVRH 10 - EVRH 40

INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M

Crankcase pressure regulator Type KVL

Solenoid valves type EVR 2 40 NC / NO

Model Ton Hand Carry Axle Jack P/N: CJ67D0250-1

Farval. Dualine Installation System Start-Up. Bulletin DL300 BIJUR DELIMON INTERNATIONAL

Specifications, Applications, Service Instructions & Parts. Flanged and Weld-in 3/4" thru 4" Port (20 mm thru 100 mm) for Refrigerants

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Installation Instructions

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

Float Dynamic Steam Trap J10

Temperature Sensor Series

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

Electric expansion valve for R744 (CO 2 ) Type AKVH

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

PRESSURE REDUCING VALVE

REFRIGERATION STRAINERS

Series 111 Accumulator Product Information

Pilot operated main valves for regulating pressure and temperature, type PM

Baumann Sanitary Diaphragm Angle and Inline Control Valve

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

Specifications, Applications, Service Instructions & Parts. HCK1, HCK1W PISTON-TYPE CHECK VALVE ¾" thru 6" (20 thru 150 mm)

CIRCLE SEAL CONTROLS

Stainless steel - the strong solution

Pressure Sensor No Series

Baumann Mikroseal Control Valve

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

ISO 9002 Hansen Technologies Corp. Burr Ridge, IL Cert. # Orlando, FL Cert. #

Introduction Maximum Inlet Pressures. Installation and Start-Up. Servicing and Adjustment CAUTION CAUTION CAUTION. General Notes

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

NECO Pumping Systems

GT-200 GATE VALVES PN16, Screwed end

Purging Air From Divider Block Lubrication Systems

P445 Series Electronic Lube Oil Control

PARKER SOLENOID VALVES GENERAL PURPOSE SOLENOID VALVE SOLENOID COILS FOR GENERAL PURPOSE VALVES PARKER GP SERIES

I & M Mark 708. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & 14M Actuator and Motor Valve

Solenoid valves. Solenoid valves, type PKVD Solenoid valves, type EVR NC / NO

Pathfinder Remote Evaporators

NOTE: Visit our website at for video repair procedures, under the Tools section.

TECHNICAL DATA. Q= C v P S

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

M-1115S Series Fuel Pump

Installation Instructions

DeZURIK DR 40B ROTARY DIAPHRAGM ACTUATOR

Sporlan Gas Cooler/ Flash Gas Bypass Valves

PRESSURE REDUCING CONTROL VALVE

Transcription:

CATALOG 201 Page 63 t EVAPORATOR PRESSURE REGULATING VALVES (S)ORIT-12, -15 and -20 Features n High side pilot for improved temperature control and low P operation n Adjustable n Optional solenoid stop feature to close valve during defrost n Normally open design allows system evacuation without manual operator These EPRs are pilot operated using high side pressure and require a pilot supply connection from the compressor discharge to operate. They are designed to be normally open providing an unparalleled ability to operate with virtually no suction line pressure drop. The pilot operated design does not require the allowable evaporator pressure change necessary with the direct acting models, and can be simply sized based on design evaporator temperature and available pressure drop across the valve at full load conditions. Specifications VALVE TYPE PORT SIZE Inches ADJUST- MENT RANGE psig and Certified STANDARD COIL RATINGS *MKC-1 VOLTS/CYCLES WATTS SORIT CONNEC- TIONS ODF SOLDER Inches (S)ORIT-12 25/32 24/50-60 1-1/8 (S)ORIT-15 1 0/100 120/50-60 208-240/50-60 10 1-3/8 (S)ORIT-20 1-5/16 120-208-240/50-60 1-5/8 *Available with junction box or conduit boss at no extra charge. For voltage other than listed consult Bulletin 30-10. Capacities Tons Capacities based on 60 F condensing temperature, 0 F superheat at the evaporator, and 25 F superheat at the valve. VALVE TYPE (S)ORIT-12 (S)ORIT-15 (S)ORIT-20 EVAPORATOR TEMPERATURE F REFRIGERANT 22 134a 404A 507 PRESSURE DROP ACROSS VALVE psi 0.5 2 5 10 0.5 2 5 10 0.5 2 5 10 0.5 2 5 10 40 2.30 4.56 7.13 9.89 1.83 3.62 5.59 7.62 2.22 4.42 6.92 9.61 2.15 4.28 6.70 9.32 20 1.88 3.74 5.80 7.97 1.45 2.85 4.35 5.80 1.79 3.55 5.53 7.62 1.74 3.45 5.37 7.41 0 1.52 3.00 4.62 6.23 1.12 2.19 3.27 4.20 1.41 2.79 4.32 5.87 1.38 2.72 4.21 5.74-20 1.20 2.35 3.56 4.67 1.09 2.15 3.27 4.34 1.07 2.10 3.20 4.27 40 3.86 7.67 12.0 16.6 3.07 6.07 9.38 12.7 3.73 7.43 11.6 16.1 3.61 7.19 11.3 15.6 20 3.17 6.27 9.74 13.3 2.43 4.78 7.29 9.68 3.00 5.96 9.27 12.8 2.92 5.79 9.01 12.4 0 2.55 5.03 7.73 10.4 1.88 3.67 5.47 6.97 2.37 4.69 7.24 9.81 2.31 4.57 7.06 9.59-20 2.01 3.94 5.95 7.77 1.83 3.60 5.48 7.24 1.79 3.52 5.36 7.11 40 8.33 16.5 25.7 35.5 6.63 13.1 20.1 27.0 8.06 16.0 25.0 34.5 7.80 15.5 24.2 33.5 20 6.83 13.5 20.9 28.4 5.24 10.3 15.5 20.3 6.49 12.8 19.9 27.2 6.30 12.5 19.4 26.5 0 5.50 10.8 16.5 22.0 4.06 7.85 11.6 14.4 5.12 10.1 15.5 20.8 4.99 9.84 15.1 20.4-20 4.34 8.45 12.6 16.2 3.96 7.74 11.7 15.2 3.86 7.56 11.4 15.0 Refrigerant Liquid Temperature Correction Factors LIQUID TEMPERATURE ENTERING VALVE F REFRIGERANT 0 10 20 30 40 50 60 70 80 90 100 CORRECTION FACTOR, CF LIQUID TEMPERATURE R-22 1.22 1.18 1.15 1.11 1.07 1.04 1.00 0.96 0.92 0.88 0.84 R-134a 1.26 1.22 1.18 1.14 1.09 1.05 1.00 0.95 0.90 0.86 0.81 R-404A 1.33 1.28 1.23 1.17 1.12 1.06 1.00 0.94 0.88 0.81 0.74 R-507 1.34 1.29 1.23 1.17 1.12 1.06 1.00 0.94 0.88 0.82 0.75 *ARI standard capacities are based on 100 F saturated liquid temperature. Use the correction factor for 100 F liquid temperature and the capacities at 40 F evaporator temperature to determine ARI standard capacity ratings. Example: The capacity of a (S)ORIT-12 using R-22, evaporator temperature of 20 F, 2 psi pressure drop across the valve and a liquid temperature of 50 F, is equal to (3.74 x 1.04) 3.9 tons. These factors correct for net refrigerating effect and are based on an average temperature of 0 F. However, they may be used for any evaporator temperature from -35 F to 40 F since the variation in the actual factors across this range is insignificant. Installation When installing these valves with solder connections, the internal parts should be protected from overheating by wrapping the valve with a wet cloth. Nomenclature/Ordering Instructions S ORI T 15 0/100 1-3/8 ODF 120/50-60 Solenoid Stop Feature Valve Type: Open on Rise of Inlet Pressure Pressure Tap on Inlet Connection Valve Size Adjustment Range psig* Connections ODF Solder Electrical Specifications for Solenoid Stop Feature * Other pressure ranges are available. For complete information see your Sporlan Wholesaler, our website at www.sporlan.com, or write Sporlan and request Bulletin 90-20.

BULLETIN 90-20 / Page 11 PRODUCT FEATURES, SPECIFICATIONS, & NOMENCLATURE (S)ORIT-12, -15, and -20 and and Recognized. Features High side pilot for improved temperature control and low P operation Adjustable settings up to 150 psig Optional solenoid stop feature to close valve during system defrost Normally open design allows system evacuation without a manual operator E 1.56 Coil Removal Top View Specifications Maximum Rated Pressure = 450 psig Maximum Test Pressure = 450 psig MOPD = 300 psi (SORIT model only) Maximum Ambient Temperature = 120 F Maximum Fluid Temperature = 240 F Minimum Ambient/Fluid Temperature = -40 F Factory Setting = See table Agency Certifications: Agency Product Guide File Country UL SORIT-12, -15, -20 YIOZ MH4576 USA ULc SORIT-12, -15, -20 YIOZ7 MH4576 Canada UL ORIT-12, -15, -20 SFJQ SA5460 USA ULc ORIT-12, -15, -20 SFJQ7 SA5460 Canada D A C B B Optional Solenoid Stop Feature VALVE TYPE PORT SIZE ADJUSTMENT RANGE psig (Standard BOLD) STANDARD COIL RATINGS **MKC-1 CONNECTION ODF SOLDER Inches DIMENSIONS Inches WEIGHT Pounds with solenoid stop WEIGHT Pounds without solenoid stop Volts/Cycles Watts A B C D E NET SHIPPING NET SHIPPING (S)ORIT-12 25/32 0/100 24/50-60 7/8, 1-1/8, 1-3/8 4.99 4.25 0.72 6.50 3.46 4.00 4.75 3.50 4.25 (Factory set 30)* 120/50-60 (S)ORIT-15 1 10 1-3/8 4.91 5.53 0.88 6.42 3.46 5.75 7.00 5.25 6.50 75/150 208-240/50-60 (S)ORIT-20 1-5/16 (Factory set 120)* 120-208-240/50-60 1-5/8, 2-1/8 5.66 5.53 1.44 7.16 3.50 9.75 11.00 9.25 10.50 * Manufacturers can specify special settings. ** Available with junction box or conduit boss at no extra charge. For voltages other than listed consult Bulletin 30-10. Valve Nomenclature: S ORI T 15 0/100 1-3/8 ODF 120/50-60 Solenoid Stop feature Valve type: Open on Rise of Inlet pressure Pressure tap on inlet connection Valve size Adjustment range psig* Connections ODF Solder Electrical specifications for Solenoid Stop Feature * Other pressure ranges are available Omission of designation for an optional item indicates a request for a valve less that specific option. Example: ORIT-15-0/75-1-3/8 ODF; this indicates a valve less the solenoid stop feature. When ordering a valve with a solenoid stop feature, specify voltage and cycles. When ordering the solenoid coil assembly only, specify MKC-1 coil, voltage and cycles. Example: MKC-1-120 volts/50-60 cycles.

February 2008 / BULLETIN 90-21-1 Installation & Service Instructions (S)ORIT-12, (S)ORIT-15, (S)ORIT-20 (S)ORIT ORIT INSTALLATION INSTRUCTIONS To insure optimum performance, evaporator pressure regulating valves must be selected and applied correctly. This is covered thoroughly in Bulletin 90-20-1. However, proper installation procedures are equally important. All of the information in the Application Section should be reviewed before installing (S)ORIT valves. VALVE LOCATION The (S)ORIT-12, -15 and -20 must be installed upstream of any other suction line controls or accessories. They may be installed in the horizontal or vertical position (Do not install upside down.) whichever best suits the application and permits easy adjustment and accessibility. However, consideration should be given to locating these valves so they don t act as an oil trap, or so solder cannot run into the internal parts during brazing in the suction line. Reverse flow is not recommended. Therefore, a high side to low side hot gas defrost line must be connected upstream of the (S)ORIT-12, -15 and -20. INSTALLATION and BRAZING PROCEDURES It is not necessary to disassemble the valve when soldering to the connecting lines. Any of the commonly used types of solder (such as 50-50, 95-5, Easy-Flo, Phos-Copper or equivalents) are satisfactory. It is important regardless of the solder used to direct the flame away from the valve body and avoid excessive heat on the diaphragm of the pilot valve. As an extra precaution, a damp cloth should be wrapped around the diaphragm during the soldering operation. IMPORTANT: The pilot valve high pressure source is the primary valve port closing force, so this connection must be made for proper performance. There are several precautions to observe when making this connection. 1. Generally the high pressure connection is made either to the discharge line or the top of the receiver. If hot discharge gas is used for defrost, the (S)ORIT pilot supply line must originate from the same location as that of the hot gas defrost line. However, equipment manufacturers sometime select other locations that are compatible with their specific design requirements. Precautions should always be taken so this line does not serve as an oil trap. The pilot supply line should be kept as short as possible to minimize condensing. Alternate feeding of gas and liquid to the pilot supply may cause the valve to operate erratically. 2. It is also recommended that a hand valve or solenoid valve (Sporlan A3/E3) be installed in this line so the pilot can be isolated should servicing become necessary. The hand valve or solenoid valve is mandatory if it is necessary to pump out an evaporator for service or for a pump-down system. Closing the hand valve or solenoid valve will cause the main piston to shift to the full open position for rapid evacuation of the evaporator. The positive closure of the pilot supply line is also necessary on pump-down systems to eliminate the high side to low side equalization path. FOR USE ON REFRIGERATION and/or AIR CONDITIONING SYSTEMS ONLY Bulletin 90-21-1, February 2008, supersedes Bulletin 90-21-1, dated November 1999, and all prior publications.

Page 2 / BULLETIN 90-21-1 The (S)ORIT-12, -15 and -20 are normally open and by closing off the pilot supply pressure (closing pressure), the (S)ORIT main piston will shift to the full open position. For dual temperature applications, closing of the solenoid valve located in the pilot supply line will allow the evaporator to operate at the lower suction pressure/ temperature. Note: The solenoid valve must be open at all times during defrost no matter the application. 3. To insure proper performance, the high pressure source supplied to the inlet of the pilot valve must be at least 50 psi above the outlet suction pressure of the (S)ORIT evaporator pressure regulator. TEST PRESSURES and DEHYDRATION TEMPERA- TURES For better leak detection, an inert dry gas, such as nitrogen or CO 2, may be added to an idle system. CAUTION: Inert gases must be added to the system carefully through a pressure regulator. Unregulated gas pressure can seriously damage the system and endanger human life. Never use oxygen or explosive gases. Excessive pressure can shorten the life of the pilot regulator valve diaphragm. The maximum low side test pressure that can safely be applied is 450 psig. This maximum pressure is well above the minimum field leak test pressures for low side listed in the ANSI/ASHRAE Standard 15-1994. The maximum dehydration temperature the valve body can be subjected without danger is 240 F. VALVE SETTING and ADJUSTMENT The standard factory setting for the 0/100 psig range is 30 psig. The main function of an (S)ORIT valve is to keep the evaporator pressure above some given point at minimum load conditions. Therefore, even though the valves are selected on the basis of pressure drop at full load conditions, they should be adjusted to maintain the minimum allowable evaporator pressure under the actual minimum load conditions. When adjusting both evaporator pressure regulating valves and thermostatic expansion valves, the following procedure is recommended. With the expansion valve at the Sporlan factory setting, or at a manufacturer s predetermined setpoint, and under the actual minimum load condition, the evaporator pressure regulating valve should be adjusted to the desired setting. If necessary, the thermostatic expansion valve or valves can be adjusted to the desired superheat setting while under the normal operating load condition. Finally, if superheat adjustments were made to the thermostatic expansion valve then the evaporator pressure regulator set point should be confirmed at minimum load conditions. When an evaporator pressure regulating valve has been operating for a period of time at a given setting and an increase in the setting is required, as much as 30 minutes may be required for the new balance to take place after an adjustment is made. If the valve is being adjusted to a lower setting an immediate response to an adjustment should be observed. To adjust the (S)ORIT valves, turn the adjustment screw with a 3/8 hex wrench. A clockwise rotation increases the valve setting, while a counterclockwise rotation decreases the setting. To obtain the desired setting, a pressure gauge should be utilized on the inlet side of the valve so the effects of any adjustments can be observed. When (S)ORITs are installed in parallel, each should be adjusted the same amount to obtain optimum performance. If one valve has been adjusted more than the other, both valves should be adjusted all the way in before resetting them an equal amount. SERVICE INSTRUCTIONS The (S)ORIT-12, -15 and -20 can be easily disassembled for inspection and cleaning, or for replacement of the pilot assembly. The pilot assembly is available with (Kit number K-Y1005) or without (Kit number K-Y1010) the solenoid stop valve. The solenoid stop valve is not available separately and should not be removed from the pilot regulator, nor should a standard solenoid valve be added to the pilot assembly to achieve the stop feature. The pilot port is critically sized with an orifice in the outlet of the pilot assembly. See page 4 for pilot kit components. CAUTION: The pilot assembly should be isolated from the high pressure power source before removal, and the main valve body should be isolated from inlet and outlet pressures. The (S)ORIT-12, -15 and -20 are normally open and by closing off the pilot supply pressure (closing pressure), the (S)ORIT main piston will shift to the full open position. PILOT REPLACEMENT INSTRUCTIONS 1. Disconnect the three connections of the pilot valve. They are: inlet pilot tube outlet pilot tube high pressure source 2. With the locknut or body flange still intact, place a wrench on the bottom fitting of the pilot valve. Turn counterclockwise and remove the pilot assembly from the adaptor. 3. Install the new pilot assembly. (At this point the flange is still securely bolted to the valve body.) Again place a wrench on the bottom connection of the pilot valve. Turn clockwise until the pilot assembly is firmly in place. Do not attempt to align the three pilot valve connections at this time. 4. Remove the locknut or cap screws and replace the gasket under the adaptor. Two gaskets are supplied with each pilot assembly kit. The correct gasket for the (S)ORIT-12 and -15 is the tetraseal. The (S)ORIT-20 uses the composition gasket. See Figure 2 for actual dimensions of the tetraseal and the gasket. 5. Reassemble the valve. Allen head cap screws must be replaced with the hex head screws included with the pilot assembly kit. Before completely tightening the locknut or cap screws, rotate the pilot valve to properly align the inlet, outlet and external equalizer connections. Join these connections and tighten the locknut of the (S)ORIT-12 to 30 ft-lbf. The torque value for the cap screws on the SORIT-15 should be 110 in-lbf and 180 inlbf for the SORIT-20. Uniformity of compression from the four cap screws is important. Screw the flange down evenly and firmly. The pilot replacement is now complete.

(S)ORIT-12: PISTON REPLACEMENT 1. Remove the pilot assembly from the adaptor as described in Steps 1 and 2 of the pilot replacement instructions. 2. Remove the locknut and replace the adaptor, tetraseal, piston assembly and bottom spring. Reassemble the valve and tighten the locknut to 30 ft. lbs. 3. Reinstall the pilot assembly. Place a wrench on the bottom connection of the pilot valve and turn clockwise until the pilot assembly is firmly in place. Do not attempt to align the three pilot valve connections at this time. 4. Loosen the locknut and rotate the pilot valve to properly align the inlet, outlet and external equalizer connections. BULLETIN 90-21-1 / Page 3 Join these connections and tighten the locknut to 30 ft. lbs. (S)ORIT-15 & 20: 1. Disconnect the three connections of the pilot valve and remove the four cap screws. The complete pilot assembly adaptor and body flange can now be lifted off the main valve body. 2. Replace the piston assembly, body sleeve and bottom spring. 3. Install a new gasket and reassemble the valve. Before completely tightening the cap screws, rotate the pilot valve to properly align the inlet, outlet and external equalizer connections. Join these connections and tighten the cap screws. A torque value for the cap screws is not recommended but uniformity of compression from the four cap screws is important. Screw the flange down evenly and firmly. FIGURE 1 3 ORIT PILOT ASSEMBLY (without solenoid stop valve) OR 5 COIL SCREW 5 VALVE NAMEPLATE 5 ELEMENT 3 SORIT PILOT ASSEMBLY (with solenoid stop valve) 4 BODY FLANGE 5 CAP SCREW BOTTOM CAP 5 COPPER GASKET 5 STRAINER 4 ADAPTOR 1 ADAPTOR 4 LOCKNUT 5 ELEMENT 7 GASKET /TETRASEAL 5 STRAINER 2 PISTON OBSOLETE ADAPTOR 2 ADAPTOR (O-RING Groove) 2 BODY SLEEVE 7 GASKET 6 O-RING 2 PISTON 2 SPRING 2 SPRING 1 BODY 1 BODY (S)ORIT-12 (S)ORIT-15 & -20 1 Replacement part not available. 2 Part is not available separately, but is included with the Internal Parts Kit(s). 3 Part is not available separately, but is included with the Pilot Assembly Kit(s). 4 Part is available separately. 5 Part is available separately, and is also included with the Pilot Assembly Kit(s). 6 Part is available separately, and is also included with the Internal Parts Kit(s). 7 Part is available separately, and is also included with the Pilot Assembly Kit(s) and the Internal Parts Kit(s).

Page 4 / BULLETIN 90-21-1 FIGURE 2 T-Seal for (S)ORIT-12, 15 ID = 1.53 OD = 1.71 Gasket for (S)ORIT-20 ID = 1.85 OD = 2.23 PART NUMBER REPLACEMENT PARTS AND PARTS KITS DESCRIPTION REPLACEMENT PARTS SOLD SEPARATELY VALVE TYPE AND SIZE ORIT SORIT 12 15 20 12 15 20 QUANTITY REQUIRED 2421-000 ADAPTOR 1 1 2422-000 ADAPTOR 1 1 2420-002 BODY FLANGE 1 1 2423-002 BODY FLANGE 1 1 2625-001 CAP SCREW 4 4 2625-002 CAP SCREW 4 4 1390-000 COIL SCREW 2539-000 GASKET 1 1 2645-000 GASKET/TETRASEAL 1 6041-000 LOCKNUT 1 1 0621-028 O-RING 1 4508-031 O-RING 1 1 GASKET (Enclosing Tube Locknut 4323-000 Style from Date Code 3998 to Present) Not Shown 621-016 O-RING (Enclosing Tube Locknut Style Through Date Code 3898) Not Shown 621-014 O-RING (Enclosing Tube 4 Screw Style ONLY) Not Shown 2445-000 STRAINER 0532-001 0532-002 VALVE NAMEPLATE 0532-003 JP-543-002 COPPER FLARE GASKET 2 REPLACEMENT PILOT VALVE PARTS KITS 1 A-4-0/100 ELEMENT K-Y1005-1 All Kits Include: Pilot Assembly, K-Y1010 Strainer, Cap Screws, Nameplates, Gaskets and Tetraseals. K-Y1005-1 also includes a coil screw. REPLACEMENT INTERNAL PARTS KITS KS-ORI-12 3 KS-ORI/ CDA-15 KS-ORI/ CDA-20 All Kits include: Gasket(s), Piston and Spring. The KS-ORI-12 also includes the Adaptor. The KS-ORI/ CDA-15 and KS-ORI/CDA-20 includes a Body Sleeve and O-Ring. 1 1 1 1 1 1 1 The pilot valve is available with or without the solenoid stop valve. The solenoid stop valve is not available separately and should not be removed from the pilot regulator. 2 This part may be necessary to adapt a new pilot to some obsolete valves. 3 Replacement (S)ORIT-12 internal parts are only compatible with the Y1005 and Y1010 pilot valves. When using these parts with obsolete pilot valves, the pilot valve must also be replaced. SERVICE TIPS MALFUNCTION CAUSE REMEDY Failure to open 1. Dirt or foreign material holding pilot port open. 1. Disassemble and clean pilot port. Does not regulate or regulates sluggishly Failure to close for defrost 2. Pilot solenoid valve coil failure. If applicable. 2. Replace solenoid valve coil. Use the MKC-1 coil with the proper voltage. 1. The high pressure source supplied to the inlet of the pilot valve must be 1. Re-locate pilot valve power source. at least 50 psi above the outlet suction pressure of the (S)ORIT. 2. If the pilot supply line is of considerable distance, condensing may occur. 2. Insulate pilot supply line or if supply line originates from the top of the receiver move it to the top of the discharge line. 1. High pressure supply line pinched shut or plugged. 1. Replace or clean high pressure supply line. 2. T-seal or gasket between adaptor and valve body does not seal. If this occurs, pressure can bleed out of the chamber faster than can be supplied by the pilot valve. 3. Dirt or foreign material either lodged between piston and sleeve causing hang-up or excessive scoring in the sleeve or the piston allowing the high pressure to bleed out of the chamber above the piston. 4. Inlet strainer to pilot plugged with foreign material. 5. Refrigerant flow through pilot is restricted by oil in the pilot supply line either due to a trapped supply line or too much oil in the system. 6. Pilot supply pressure originates from a lower pressure source than is used for defrost. 2. Replace T-seal or gasket. These should be replaced any time the pilot assembly is removed from the valve body. 3. 4. 5. 6. Clean or if necessary replace the piston and the sleeve. Clean or replace strainer. Check the pilot supply line to be sure that it is open, and that it does not serve as an oil trap. If the pilot pressure source originates from the top of the receiver, and the valve is not closing for defrost, move the pilot supply pressure source to the discharge line. Printed in U.S. of A. Co p y r i g h t 2008 By Sp o r l a n Division - Pa r k e r Ha n n i f i n, Wa s h i n g t o n, Mi s s o u r i 0208